READING FEATURES

7

7.1.2 Advanced Code Reconstruction Reading Conditions

 ANSI Grade B minimum scans/sec

 three codes enabled simultaneously background

The following tables describe the minimum code height requirements (in mm) for standard

ACR4™ applications depending on the code symbology.

Minimum Code Height for ACR4 Reading (mm)

45° max 30° max

Speed 0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

2/5 Interleaved

Code Resolution

(mm)

0.25

12 15 18 21 23 26 8 11 13 15 17 19

0.30

14 16 19 22 25 28 9 11 14 16 18 20

0.33

15 17 20 23 26 29 10 12 14 16 19 21

0.38

16 19 22 24 27 30 11 13 15 17 20 22

0.50

20 22 25 28 31 34 13 15 17 19 22 24

0.72

26 29 32 35 37 40 17 19 21 23 25 28

1.00

35 37 40 43 46 49 21 24 26 28 30 33

Ratio 3:1

Table 1

Minimum Code Height for ACR4 Reading (mm)

45° max 30° max

Speed 0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

Code 39

Code Resolution

(mm)

0.25

11 14 16 19 22 25 8 10 12 14 16 19

0.30

12 15 18 20 23 26 8 10 13 15 17 19

0.33

13 16 18 21 24 27 9 11 13 15 18 20

0.38

14 17 20 22 25 28 9 12 14 16 18 21

0.50

17 20 22 25 28 31 11 13 16 18 20 22

0.72

22 25 28 31 33 36 14 16 19 21 23 25

1.00

29 32 35 37 40 43 18 20 23 25 27 29

Ratio 3:1; Interdigit = Module Size

Table 2

Minimum Code Height for ACR4 Reading (mm)

45° max 30° max

Speed 0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

Code 128 – EAN 128

Code Resolution

(mm)

0.25

9 12 15 18 21 23 7 9 11 13 16 18

0.30

10 13 16 19 22 24 7 9 12 14 16 18

0.33

11 14 16 19 22 25 8 10 12 14 17 19

0.38

12 15 17 20 23 26 8 10 13 15 17 19

0.50

14 17 20 22 25 28 9 12 14 16 18 21

0.72

18 21 24 27 29 32 12 14 16 19 21 23

1.00

24 26 29 32 35 38 15 17 19 22 24 26

Table 3

87

7

DS4800 REFERENCE MANUAL

Minimum Code Height for ACR4 Reading (mm)

45° max 30° max

Speed 0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

Codabar

Code Resolution

(mm)

0.25

10 12 15 18 21 24 7 9 11 14 16 18

0.30

11 13 16 19 22 25 7 10 12 14 16 19

0.33

11 14 17 20 22 26 8 10 12 14 17 19

0.38

12 15 18 21 23 26 8 11 13 15 17 20

0.50

15 17 20 23 26 29 10 12 14 16 19 21

0.72

19 22 25 27 30 33 12 15 17 19 21 24

1.00

25 27 30 33 36 39 16 18 20 22 25 27

Ratio 3:1; Interdigit = Module Size

Table 4

Minimum Code Height for ACR4 Reading (mm)

45° max 30° max

Speed 0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

EAN 8-13, UPC-A

Code Resolution

(mm)

0.25

9 12 15 18 21 23 7 9 11 13 16 18

0.30

10 13 16 19 22 24 7 9 12 14 16 18

0.33

11 14 16 19 22 25 8 10 12 14 17 19

0.38

12 15 17 20 23 26 8 10 13 15 17 19

0.50

14 17 20 22 25 28 9 12 14 16 18 21

0.72

18 21 24 27 29 32 12 14 16 19 21 23

1.00

24 26 29 32 35 38 15 17 19 22 24 26

Table 5

NOTE

To maximize scanner performance in Advanced Code Reconstruction

Reading applications, enable only the code symbologies that will actually be used in the application and disable any code symbologies that will not be used in the application.