SPECIFICATIONS. JRC JCY-1800 -
Show HTML Add to My manuals197 Pages
JRC JCY-1800 is a top-of-the-line VDR (Voyage Data Recorder) that provides comprehensive recording and storage of essential data for voyage analysis, troubleshooting, and incident reconstruction. It is designed to meet the latest IMO and IEC 61996-1/2 standards, ensuring compliance with international regulations.
advertisement
![SPECIFICATIONS. JRC JCY-1800 - | Manualzz SPECIFICATIONS. JRC JCY-1800 - | Manualzz](http://s3.manualzz.com/store/data/034605456_1-60ccb6cb110d86b0e10727ad4d3e5c24-360x466.png)
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1. SPECIFICATIONS
1.1. Outline of the Equipment
This equipment let the helps to detect the causes of marine accidents to prevent the recurrence in the future.
The equipment records voyage data, as required by the International Standard, during the navigation and the hull data of the vessel.
1.2. Feature of new VDR/S-VDR
1.2.1. Common features in VDR/S-VDR
1) Black Box
▪ The operation panel on the door of RCU is removed.
▪ The external Operation Panel Unit is added to a standard equipment.
2) Radar image (option for S-VDR)
▪ 2 input ports for radar image
Selectable recording is normal function.
Recording Radar image from both of channels is optional function.
Refer to the 1.2.6 clause for details.
3) New Playback software
▪ Playback software for users is attached standard.
CF card adapter is attached standard.
Real time monitor and prolonged backup into HDD can be active.
▪ Replay software for accident investigators is attached standard.
The recorded data on capsule can be downloaded.
1) Reception of serial data (NMEA)
▪ Serial reception function is combined to RCU unit. (Combine DAU function)
▪ 32 input channels standard
2) Fixed capsule
▪ Using new VDR capsule produced by L-3
3) Diagnosis of JRC equipment by remote maintenance
▪ Remote maintenance function of JRC equipment is preinstalled.
Acquire maintenance data out put from JRC equipment
The acquired data can be downloaded.
1
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1) Reception of serial data (NMEA)
▪ Serial reception function is combined to RCU unit. (Combine DAU function)
▪ 16 input channels standard
2) Radar image
▪ Prepare option kit (cable and BNC connector) for FGB connection
Extends on ship
3) NSK board
▪ NMEA conversion board of synchrony or step signal (for ship’s heading) and pulse signal (for ship’s speed) is preinstalled.
4) Fixed capsule
▪ Using new VDR capsule produced by L-3
5) Correspondence of Float-free capsule
▪ Only fixed capsule
▪ The L-3 float-capsule in future
1)New digital signal converter
▪ 64 contacts type (NCT-72) or 16 contacts type (NCT-63) can be selected.
▪ Option board for A/D conversion (8 CH) can be added.
2)New Radar Interface Unit
New model is a NWP-46.
It is same as NWP-42 (current model).
1.2.5. Points of Instruction
1) Backup media
Backup media is changed into CF card from ATA card.
Adapter of CF card is a standard accessory.
2) Initial setting of ship’s heading
When connecting a heading data by a Synchro or Pulse signal, alarm is outputted at the startup of VDR. Input the initial value of the heading by the Operation Panel unit.
3) Operation Panel unit
Operation Panel unit indicates the error cause by the error codes.
The table of error code is described on the Instruction Manual.
2
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.2.6. Operation of inputting two Radar images
1) General description of operation
FGB creates PNG files from RGB signals of radar and transmits PNG files via Ethernet.
FGB have two input ports for connecting to radar.
FGB selects a recording channel from both channels.
CH1
FGB
INPUT PORTS for RGB signals
A/D
PNG file
LAN
CH2
2) Timing chart
CH1
CH2
15s
7.5s
7.5s
15s
CH1
Recording CH select
CH2
Recording PNG file
FGB creates PNG files from both channels usually and FGB selects the one PNG file for recording.
3) Operation mode
▪ Connecting the only main radar, recording the main radar image (Standard)
▪ Connecting both main radar and sub radar, recording activated radar image (Standard)
▪ Connecting both main radar and sub radar, recording both radar image (Option)
In this case, the storage capacity of a capsule and CF card is changed into 4GB.
4) Real time monitor data
In spite of not recording, the Radar image of both channels is captured in a cycle of 15 seconds.
All captured image data is outputted to a real-time monitor.
The image which is not recorded is also outputted to the real-time monitor.
The real-time monitor receives an image in a cycle of 7.5 seconds.
3
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.3. Difference between VDR and S-VDR
Capsule
NDH-316 (New capsule is made by
L-3.)
Main Unit
Recording Control Unit (RCU)
Function of DAU is Included into the
RCU
Serial Data recording Including serial interface into the RCU
Audio recording
Video recording
Operation Panel of
RCU
External Operation
Panel Unit
Backup Media
UPS
NSK Interface
Dry Contact signal
Input channel: 32 ports for
IEC61162-1/-2
Input CH: 9 sets for microphone unit
(Recording channel are 3)
3 sets for VHF radio
(Recording channel is 1)
Compressing format: G726
Input CH: 2CH for analog RGB
(selectable recording)
Compressing format: PNG
No operation panel in the RCU
Standard
Compact Flash Card
Capacity: 2GB
Backup voltage is DC24V (5Ah)
Including NSK interface (option)
NDH-317 (New capsule is made by
L-3.)
Same as VDR (JCY-1800)
Only fixed capsule
Unification of RCU and DAU
Including serial interface into the
RCU
Input channel: 16 ports for
IEC61162-1/-2
Same as VDR (JCY-1800)
Option
(remove the FGB, cable and BNC) connector)
Same as VDR (JCY-1800)
Same as VDR (JCY-1800)
Same as VDR (JCY-1800)
RMB is not installed to the NDV-1850
Including Video selector
RCU is the Black Box
With CF card adapter
Same as VDR (JCY-1800) New type small battery
Including NSK interface (standard) for synchro , step and pulse signal
Same as VDR (JCY-1800) Selectable 64ch or
16ch
Analog signal
Option Unit: NCT-72
Input channel: 64 ports for dry contact signal
Option Unit: NCT-63
Input channel: 16 ports for dry contact signal
Option board for NCT-72 / 63
Input channel: 8 ports for analog signal
Same as VDR (JCY-1800) Built in the NCT-72 /
63
1) Standard system
No. Unit
1
2
Protective Capsule Unit
Recording Control Unit
VDR
NDH-316
NDV-1800
S-VDR
NCG-169
NVT-161
NDH-317 (Fixed type)
NDV-1850
NQE-3163
4
DOC No. 7ZPJD0387C
2) Option system
No. Unit
1
2
Waterproof Microphone Unit
NSK interface board
3
Frame Grabber Board Kit
4
5
6
7
FGB CH2 Kit
Digital Signal Converter
(64CH)
Digital Signal Converter
(16CH)
Analog signal Converting Board
VDR
NVT-162
CHM-378
(Standard)
(Standard)
NCT-72
NCT-63
CEF-60
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
S-VDR
NVT-162
Remark
7ZZJD0052
( FGB: CKA-137 ,RGB
Cable, LAN Cable, BNC
Connector (5 pieces))
7ZZJD0055
RCU
Only CH 1 is connectable.
Additional CH 2 is connectable.
(Connectable)
(Connectable)
NCT-72 / 63
No.
1
3
4
6
7
9
3-1
3-2
10
1) Standard configuration of the equipment
Name of Component
Protective Capsule Unit
Recording Control Unit
Data Processor Unit
Audio Junction Board
Operation Panel Unit
Spare Parts for RCU
CF Card adaptor
Playback software
Playback Software /
Real Time Monitor
Type Name
NDH-316
NQE-3163
NDV-1800
NDL-46
CQD-2041
NBL-327
NCG-169
NVT-161
Qty Function
1 y Records data on the recording medium in the recovery Protective Capsule. y At the time of sinking, the underwater acoustic beacon helps the searchers to detect the position of the Protective Capsule Unit.
1 y Connects the Protective Capsule Unit and the
Recording Control Unit with a power supply
1 cable and a LAN cable. y Outputs the recorded data to the Protective
Capsule Unit and the CF CARD. y Inputs radar images, audio data and
IEC61162-1/-2 data. y Monitors and controls the conditions of the
1
1 system. y Frame Grabber Board (FGB) for recording
Radar images is optional board. FGB is not a standard component. y Main control processing part with a built-in backup CF CARD. y Audio I/F to relay the MIC and VHF signals.
1 y Power supply equipped with a secondary battery and a charging circuit.
1 y Displays the status of S-VDR.
ALARM BUZZER, an ALARM ACK SWITCH, and LEDs are equipped.
3 y
Records the conversation in the bridge and outputs into the Recording Control Unit.
Accessories
7ZXJD0080 1 y Spares for the NDV-1800 y Fans, Fuse y for record data playback
SLCFADU 1
KB-10T5-03LBK 1 y 3m
CYC-315 1 y Only for the use by the Investigation Authorities.
y Attached inside the NDV-1800. y For the User. y Attached inside the NDV-1800.
5
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
2) Options configuration of the equipment
No. Name of Optional Component
2
3
4
5
6
7
8
9
Waterproof Microphone Unit
NSK interface board
Digital Signal Converter
(64CH)
Digital Signal Converter
(16CH)
Analog signal Converting
Board
Radar Interface Unit
Spare Parts for the DSC
Spare Parts for the RIF
Type Name
NVT-161
NVT-162
CHM-378
NCT-72
NCT-63
Function y To use an “Exposed” type, remove the flange of “Built in the ceiling” one. y Maximum nine sets of microphones can be installed, inclusive of standard configuration. y Records the conversation in the wing and outputs into the
Recording Control Unit. y Maximum nine sets of microphones can be installed, inclusive of standard configuration and NVT-161 type. y Optional interface board for heading in synchro or step signal and ship’s speed by pulse. y Installed in the NDV-1800. y Outputs IEC61162-1 data converted from 64 dry contacts. y Outputs IEC61162-1 data converted from 8 analog signals by adding the optional CEF-60. y Outputs IEC61162-1 data converted from 16 dry contacts.
y Outputs IEC61162-1 data converted from 8 analog signals by adding the optional CEF-60. y Converts eight analog signals to IEC61162-1 data. y Installed in the NCT-72/63 y Required when connecting the radar of UXGA display.
CEF-60
NWP-46
7ZXJD0092
7ZXJD0093
Accessories y Spares for the NCT-72/63 y Fuse y Spares for the NWP-46 y Fan, Fuse
No.
1
3
4
3-1
3-2
1) Standard configuration of the equipment
Name of Component
Protective Capsule Unit
Recording Control Unit
Data Processor Unit
Audio Junction Board
Type Name
NDH-317
NQE-3163
NDV-1850 interface CHM-378
Operation Panel Unit
NDL-46
CQD-2041
NBL-327
NCG-169
Qty Function
1 y Records data on the recording medium in the recovery Protective Capsule. y At the time of sinking, the underwater acoustic beacon operates to detect the position of the
Protective Capsule Unit.
1 y Connects the Protective Capsule Unit and the
Recording Control Unit with a power supply
1 cable and a LAN cable. y Outputs the recorded data to the Protective
Capsule Unit and the CF CARD. y Inputs radar images, audio data and
IEC61162-1/-2 data. y Monitors and controls the conditions of the system. y Frame Grabber Board (FGB) for recording
Radar images is an option, FGB is not a standard component.
1
1 y Main control processing part with a built-in backup CF CARD. y Audio I/F to relay the MIC and VHF signals.
1 y Power supply equipped with a secondary battery and a charging circuit.
1 y Interface board for heading in synchro or step
1 signal and ship’s speed by pulse. y Displays the status of S-VDR.
ALARM BUZZER, an ALARM ACK SWITCH, and LEDs are equipped.
6
DOC No. 7ZPJD0387C
6
7
Spare Parts for RCU
CF Card adaptor
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
NVT-161
Accessories
3 y
Records the conversation in the bridge and outputs into the Recording Control Unit.
7ZXJD0080 1 y Spares for the NDV-1850 y Fans, Fuse y for record data playback
SLCFADU 1
KB-10T5-03LBK 1 y 3m
CYC-315
CYC-316
1
1 y Only for the use by the Investigation Authorities.
y Attached inside the NDV-1850. y For the User. y Attached inside the NDV-1850.
10 Playback Software /
Real Time Monitor
2
3
4
5
2) Options configuration of the equipment
No. Name of Optional Component
Waterproof Microphone Unit
Frame Grabber Board Kit
Second Video Channel Kit
Radar Interface Unit
Type Name
NVT-161
NVT-162
7ZZJD0052
7ZZJD0055
NWP-46
Function y To use an “Exposed” type, remove the flange of “Built in the ceiling” one. y Maximum nine sets of microphones can be installed, inclusive of standard configuration. y Records the conversation in the wing and outputs into the
Recording Control Unit. y Maximum nine sets of microphones can be installed, inclusive of standard configuration and NVT-161 type. y Kit for recording RADAR image. y Consists of; CKA-137(FGB), BNC-Dsub15 cable (1pc.),
LAN cable, BNC-JJ (5pc.), BNC connector for 3C-2V
(5pc.) y Installed in the NDV-1850. y Kit for second RADAR video channel. y Consists of; BNC-JJ (5pcs.) BNC-Dsub15 cable (1pc.),
BNC connector for 3C-2V (5pc.) y Installed in the NDV-1850. y Required when connecting the radar of UXGA display.
Accessories
6 Spare Parts for the RIF 7ZXJD0093 y Spares for the NWP-46 y Fan, Fuse z When radar images cannot be recorded, the output data of AIS must be recorded instead.
7
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.6. Present and New model Comparison table
1.6.1. VDR
Capsule
Main Unit
NDH-288A/B (made by L-3)
Beacon
Beacon Cover: Yes
Water Pressure Sensor: No
Water Switch: Dual Pins
Recording Control Unit (RCU)
Data Acquisition Unit (DAU)
Serial Data recording DAU:
Input channel: 16 ports for IEC61162
4 ports for analog signal (op.)
Audio recording Input CH: 9 sets for microphone unit
(Recording channel are 3)
3 sets for VHF radio
(Recording channel is 1)
Compressing format: G726
Video recording
Operation Panel of
RCU
External Operation
Panel Unit
Backup Media
UPS
NSK Interface
Dry Contact signal
Analog signal Option board for DAU
Input channel: 4 ports for analog signal
Option unit: NQA-4091A
Input channel: 8 ports for analog signal
Input CH: 9 sets for microphone unit
(Recording channel are 3)
3 sets for VHF radio
(Recording channel is 1)
Compressing format: G726
IEC61162-2 for
AIS
Input CH: 1ch for analog RGB
Compressing format: PNG
Input CH: 2CH for analog RGB
(selectable recording)
Compressing format: PNG
Including Video selector
Including into the door of RCU No operation panel in the RCU RCU is the Black
Box
Option Standard
PC Card (ATA type)
Capacity: 2GB
Backup voltage is DC24V (8Ah)
Option unit: NCT-27B
Option Unit : NCT-57
Input channel: 64 ports for dry contact signal
NDH-316 (New capsule is made by
L-3.)
Beacon
Beacon Cover: No
Water Pressure Sensor: Yes
Water Switch: Single Pin
Recording Control Unit (RCU)
Function of DAU is Included into the
RCU
Including serial interface into the RCU
Input channel: 32 ports for
IEC61162-1/-2
Compact Flash Card
Capacity: 2GB
Backup voltage is DC24V (5Ah)
Including NSK interface (option)
Option Unit: NCT-72
Input channel: 64 ports for dry contact signal
Option Unit: NCT-63
Input channel: 16 ports for dry contact signal
Option board for NCT-72 / 63
Input channel: 8 ports for analog signal
Only fixed capsule
Unification of
RCU and DAU
With CF card adapter
New type small battery for synchro , step and pulse signal
Selectable 64ch or
16ch
Built in the
NCT-72 / 63
8
DOC No. 7ZPJD0387C
Audio recording
Video recording
Operation Panel of
RCU
External Operation
Panel Unit
Backup Media
UPS
NSK Interface
Dry Contact signal
Analog signal
Same as VDR (JCY-1700)
Option
(remove the FGB)
Same as VDR (JCY-1700)
Same as VDR (JCY-1700)
Same as VDR (JCY-1700)
Same as VDR (JCY-1700)
Same as VDR (JCY-1700)
Same as VDR (JCY-1700)
Same as VDR (JCY-1700)
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.6.2. S-VDR
Capsule
NDH-317 (New capsule is made by
L-3.)
Beacon
Beacon Cover: No
Water Pressure Sensor: Yes
Water Switch: Single Pin
Main Unit
Same as VDR (JCY-1700)
Serial Data recording Same as VDR (JCY-1700)
NDH-317 (New capsule is made by
L-3.)
Beacon
Beacon Cover: No
Water Pressure Sensor: Yes
Water Switch: Single Pin
Same as VDR (JCY-1800)
Including serial interface into the RCU
Input channel: 16 ports for
IEC61162-1/-2
Same as VDR (JCY-1800)
Option
(remove the FGB, cable and BNC) connector)
Same as VDR (JCY-1800)
New fixed type capsule
IEC61162-2 for
AIS
Refer to a VDR comparison table for details.
Same as VDR (JCY-1800)
Same as VDR (JCY-1800)
Same as VDR (JCY-1800)
Including NSK interface (standard)
Same as VDR (JCY-1800)
Same as VDR (JCY-1800) for synchro , step and pulse signal
9
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.7. JCY-1800 System Diagram
.) .P
7(W MIC
MIC8(W.P.)
5 MIC
MIC4
MIC2
MIC1 phone No.2
phone No.1
ele ele
F T
F T
VH
VH
7 Mic-
Mic-8
Mic-
Mic-
5
4
Mic-
Mic-
2
1
B
G
R
H synch
V synch
-1Q CS
CS-1Q
S-1Q CY
CYS-1Q
*TTY
*TTY
*TTY
*TTY
*TTY
*TTY
*3C-2V
*3C-2V
*3C-2V
*3C-2V
*3C-2V
CS-1Q *TTY
* TTYCS-1
CS-1Q
* TTYCS-1
CS-1Q
* MPYC-2
* MPYC-7
* MPYC-4
phase 0Hz 1
*DPYC-2.5
220V 6 AC
) ro]
) e]
)
(Yard
Puls
(Yard
(Yard ss [STEP] ss [Synch d Log [
Compa
Spee
Compa
Gyro
Gyro or ribut ist C D From A
S-x YC * TT g
(Yard)
Analo x C-x * MPY
(Yard) ontact Dry C or ribut ist C D From A
S-x YC * TT
(Yard)
Analog
Q
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
-1Q
-1Q
-1Q CS
S-1 YC
CS
CS
* TTY
* TTY
* TTY
* TT
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
* TTYC
AIS r
(Yard) aph em
(Yard)
Othe er ar
(JRC) r r Othe
Othe r r cato ilot
(Yard)
(Yard)
(Yard)
(Yard)
(Yard)
(Yard)
(Yard)
(Yard) egr d Rad l Syst
Sounde
(Yard)
Compass og
(Yard)
(Yard)
DGPS
Auto P
Speed L tro n Tel gle Indi
Anemomet
Echo
X-Ban
Gyro
Con
Engi x C-x
Remote
Rudder An
* MPY
(Yard) t
Figure 1: System Diagram
Dry Contac
10
DOC No. 7ZPJD0387C
1.8. JCY-1850 System Diagram
2
1
No.
No.
.P.)
.P.) (W
7(W MIC
MIC8
2
1 MIC
MIC
5
4 MIC
MIC lephone lephone
8 Mic-
Mic-7
4 Mic-
Mic-5
2
1 Mic-
Mic-
VHF Te
VHF Te
B
G
R
V synch
H synch
Q
Q
Q S-1
CS-1
1Q
-1Q YS
CYS-
Q
Q S-1
S-1
-1
-1
CS-1
*TTYC
*TTY
*TTYC
*TTYC
*TTY
*TTYC
*TTY
* TTYCS
* TTYCS
*3C-2V
*3C-2V
*3C-2V
*3C-2V
*3C-2V
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
hase
5 z 1 p 0H
C-2.
0V 6
*DPY
AC22
-2 YC * MP
-7 YC * MP
-4 YC * MP
]
(Yard) ulse [P
(Yard) ro] ynch
(Yard)
TEP] ss [S ss [S d Log
Compa
Spee
Compa
Gyro
Gyro
YC
YC
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
YC
YC
YC
YC
YC
YC
YC
YC
YC
YC
S-1Q
S-1Q
* TT
* TT
* TT
* TT
* TT
* TT
* TT
* TT
* TT
* TT
* TT
* TT
* TTYC
* TTYC d) d)
(Yar dicat
(Yar
Pilo unde
(Yar
(Yar rap
(Yar omet
(Yar pas
(Yar d Log
(Yar
AIS
(Yar
DGPS d) s d) t d) d) or d) r d) er d) h d) m d) r
C) ar d) r r d)
Othe
Othe
(JR
(Yar
Othe
(Yar
(Yar
(Yar l Syste nd Rad n Teleg
Spee
Com o So e In
Auto
Ech ngl
Anem
Gyro
X-Ba
Contro
Engi er A ote Rem
Rudd
Figure 2: System Diagram
11
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.9. Functions of electrical circuit board
Main electrical circuit table of NDV-1800 (VDR)
Unit
PSU
NBL-327
Data Processor
Unit
NDL-46
Circuit name
Power supply board (PSB)
Thermo sensor board
Main Control
Board (MCB)
Audio Recording
Board (ARB)
Frame Grabber
Board (FGB)
Model Function
CBM-168 Battery backup for 2 hours
S-VDR Remark same
CHG-213 Temperature monitoring of a battery same
CDJ-2304 Main control
HUB unit: 1port + 4ports
16ports for IEC61162-1 / 2
Internal operation panel
CHA-387 Input CH: 9 sets for microphone unit (Recording channel are 3)
3 sets for VHF radio
(Recording channel is 1)
Compressing format: G726
CKA-137 Input CH: 2CH for analog RGB
(selectable)
Compressing format: PNG
CDK-287 16ports for IEC61162-1 / 2 same same
Option
Option Board
Remote
Maintenance
Board (RMB)
NSK Interface
Board (NIB)
CHM-378
(Option)
To record gyro compass signal
(Synchro / Step) and/or Ship’s speed log signal as IEC61162-1 sentence formatter
Not installed Main Control
Board for Remote
Maintenance
System
Standard
DOC No. 7ZPJD0387C
12
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
RCU: NDV-1800/1850
PSU: NBL-327
MCB: CDJ-2304
(ARB: CHA-387)
CF Cars
FGB: CKA-137
RMB: CDK-287
Mother Board
NIB: CHM-378
OPU: NCG-169
BNC connector for RGB
Battery
AC Input terminal
AC Output terminal
Display:
Error Code display
Software version
Heading value in case of Synchro or Step signal connecting
13
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10. Specifications of each unit
1.10.1. Protective Capsule Unit: PCU (NDH-316)
(1) Function:
The protective capsule unit (PCU) records navigation data, hull data, conversation in the bridge, conversation over VHF radio, and radar image data to the recording medium in the PCU.
When submerged, the Underwater Acoustic Beacon with PCU, which is a battery-powered, transmits a pulsed acoustic signal for capsule searchers.
(2) Performance: a) Interface:
1) Standard:
2) Protocol: b) Recording duration and capacity:
IEEE802.3 (10Base-T/ 100Base-TX)
TCP/IP
12 hours
2.0GB (flash memory)
1) Duration:
2) Capacity: c) Data Recording Interval:
1) Sensor Data:
2) Audio Data:
3) Image Data: d) Acoustic underwater beacon:
1) Operating frequency:
2) Operating time:
3) Detectable range: depends on the input from the sensors (normally 1 second) continuous (1 audio file / minute)
1 image per 15 second (Option)
37.5kHz ±1kHz minimum 30 days after submerged in the water
1800m - 3600m
(depends on surrounding environment) maximum 5-years 4) Battery life:
(3) Environmental condition
There shall be neither the damage of the final record media nor the loss of recorded data under the conditions shown below. a) Shock: b) Penetration: c) Fire:
A half sine-wave pulse of 50G, with an interval of 11msec
A mass of 250 kg with a pin of 100mm diameter, dropped from 3m
10 hours with 260 °C fire
1 hour with 1100 °C fire d) Deep-sea water pressure: 60 Mpa
(equivalent to 6000m of depth)
General environmental condition e) Operating temperature: f) Storage temperature g)Vibration:
-25°C to +55°C (IEC 60945 exposed type)
-55°C to +70°C (IEC 60945 exposed type)
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
(4) General specification a) Input voltage range: b) Power consumption: c) Size: d) Mass: e) Color:
19.5 - 36.5VDC
3W
182.4(W) x 206.5(D) x 218.3(H) mm
8.7kg fluorescent orange
14
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.2. Protective Capsule Unit: PCU (NDH-317)
(1) Function:
The Protective Capsule Unit (PCU) is not a float-free type but a fixed type. The PCU records navigation data, hull data, conversation in the bridge, conversation over VHF radio, and radar image data to the recording medium in the PCU.
When submerged, the Underwater Acoustic Beacon with PCU, which is a battery-powered, transmits a pulsed acoustic signal for capsule searchers.
(2) Performance: a) Interface:
1) Standard:
2) Protocol: b) Recording duration and capacity:
1) Duration:
2) Capacity: c) Data Recording Interval:
1) Sensor Data:
2) Audio Data:
3) Image Data: d) Acoustic underwater beacon:
1) Operating frequency:
IEEE802.3 (10Base-T/ 100Base-TX)
TCP/IP
12 hours
2.0GB (flash memory) depends on the input from the sensors (normally 1 second) continuous (1 audio file / minute)
1 image per 15 second (Option)
2) Operating time:
3) Detectable range:
4) Battery life:
(3) Environmental condition
37.5kHz ±1kHz minimum 30 days after submerged in the water
1800m - 3600m
(depends on surrounding environment) maximum 5-years
There shall be neither the damage of the final record media nor the loss of recorded data under the conditions shown below. a) Shock: b) Fire:
A half sine-wave pulse of 50G, with an interval of 11msec
10 hours with 260 °C fire c) Deep-sea water pressure:
1 hour with 1100 °C fire
60 Mpa
(equivalent to 6000m of depth)
General environmental condition a) Operating temperature: b) Storage temperature c)Vibration:
-25°C to +55°C (IEC 60945 exposed type)
-55°C to +70°C (IEC 60945 exposed type)
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
(4) General specification a) Input voltage range: b) Power consumption: c) Size: d) Mass: e) Color:
19.5 - 36.5VDC
3W
182(W) x 206.5(D) x 215(H) mm
8.1kg fluorescent orange
15
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.3. Recording Control Unit: RCU (NDV-1800/1850)
1.10.3.1. Operation Panel (Internal)
(1) Performance: a) Button operation:
1) Recording stop:
2) Recording restart:
3) Card recording stop: b) LED Indication:
1) Recording status
2) CF card status
3) CF card Media error
Stop to record data to PCU
Restart to record data to PCU
Stop to record data to CF card. (enables to take out CF card from RCU)
Recording / Recording stop
Recording / Recording stop (enables to take out CF card)
Access error to CF card
1.10.3.2. Data Processor Unit
(1) Function: a) Control of recording navigation and hull data to PCU. b) Collects data of navigation and hull condition according to IEC61162-1/2.
The data collected are as follows according to the IEC61996-2
1) Date and Time (UTC)
2) Ship’s position measured by the electronic position fixing system
3) Ship’s speed (over ground/water)
4) Ship’s heading with a gyrocompass or magnetic compass
5) Under keel clearance
6) Main alarms (indicated in the bridge)
7) Rudder order and response data
8) Engine order and response data
9) Hull opening status
(for RO-RO passenger ships and ferry ships only)
10) Watertight door / Fire door status
11) Bow acceleration and hull stress data
(only for the ships mandatorily having hull stress indicator)
12) Wind direction / wind speed data
(only when the vessel is equipped with anemometer)
13) AIS data (S-VDR)
When radar images cannot be recorded, the output data of AIS must be recorded as a substitute.
However, JCY-1800/1850 can also record both AIS data and radar images.
In case of S-VDR:
If the sensor outputs no data by IEC61162, items 5)-12) are not recorded. c) Capturing, encoding and recording of conversation audio on the bridge, VHF communications audio and radar image shown on the display. d) Copying the recording data to the CF card. e) Monitoring and control of the system. a) Communication to PCU:
1) Standard:
2) Protocol: b) Sensor data input :
1) Input channel:
IEEE802.3 (10Base-T/ 100Base-TX )
TCP/IP
NDV-1800 (VDR): up to 32 (channels)
NDV-1850 (S-VDR): up to 16 (channels)
16
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
2) Data input interface:
3) Recording interval: c) Bridge audio input:
1) Input channel:
IEC61162-1/-2 (RS-422) depends on the input from the sensors (normally 1 second)
2) Input sensitivity:
3) Recording interval: up to 9 (channels)
6kHz continuous (1 audio file / minute) d) VHF communications input (audio):
1) Input channel:
2) Input sensitivity:
3) Input level:
4) Recording interval: up to 3 (channels)
3.5kHz
0 dBm 600-ohm balance continuous (1 audio file / minute) e) Radar image data input (input of No1. X band radar is recommended):
1) Input channel: 2 (channels)
Auto selection of a radar image from both channels
2) Input interface:
- RGB:
- Hs:
- Vs:
3) Resolution:
4) Refresh rate:
(If the radar is of JRC make, automatic selection of on-operation radar is possible.) analog RGB/Hs/Vs
0.7Vp-p (video signal)
TTL
TTL
640 x 350 – 1600 x 1200 pixel (conforms to VESA DMTS)
60 - 85 Hz (conforms to VESA DMTS)
5) Recording interval: f) Recording data backup:
1) Media:
2) Storage capacity: g) Blackout processing:
1) Recording duration:
2) Restoration time required: h) GPS select signal input:
1) Interface:
(Resolution 1600 x 1200 pixel 60Hz only)
1 image every 15 seconds
CF card
(Adapter for PCMCIA type-2 is attached to the RCU.)
2.0GB
2 hours while blackout
(during the blackout, only the conversation in the bridge is recorded) less than 1 minute
(Recovery time from blackout operation to normal operation on restoration of ship’s generator.)
2) Operation: i) RADAR select signal input:
1) Interface of JRC radar:
2) Operation of JRC radar:
3) Interface of other radar:
Dry (voltage free) contact closure
(Commonly used with External Contact Input )
Recording GPS selection (active open/close)
(Only JMA-9900, JMA-900M, JMA-5300
IEC61162-1 (RS-422)
Active radar selection by JRC original sentence
Dry (voltage free) contact closure
(Commonly used with External Contact Input )
Recording RADAR selection by dry contact closure (active open/close) 4) Operation of other radar: j) External Contact Input (dry contact):
1) Number of input: maximum 3 dry contacts (voltage free)
(Commonly used with the input signals which select RADAR or GPS.)
Registers sentences at the time of their making and opening 2) Output sentences:
17
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.3.3. Power Supply Unit
(1) Function: a) Power supply to RCU and PCU in normal operation b) Power supply to RCU and PCU for 2 hours on blackout.
(2) Performance: a) Input voltage range: b) Output voltage: c) Maximum power output: d) Battery capacity: e) Expectant battery age:
100 - 120VAC +/- 10% 1-phase 50/60Hz +/-5%
200 - 240VAC +/- 10% 1-phase 50/60Hz +/-5%
(Auto switching)
5VDC, 12VDC, 24VDC
140VA
24VDC 5Ah max 4-years
(Depending on circumstance. This age is based on ambient operating temperature: 25 deg., load 70%)
1.10.3.4. External Interface a) External alarm lamp output:
1) Interface:
2) Operation:
3) Current: b) External alarm buzzer output:
1) Interface:
2) Operation:
3) Current:
Dry (voltage free) contact closure
System down (normal-close or open)
1A or less at 24VDC / 0.5A or less at 125VAC
Dry (voltage free) contact closure
System down (normal-close or open)
1A or less at 24VDC / 0.5A or less at 125VAC
1.10.3.5. Environmental condition
(1) Operating temperature:
(2) Temperature and humidity:
(3) Vibration:
-15
°C to +55°C (IEC 60945 protected type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
1.10.3.6. General specification
(1) Power voltage: 100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
(2) Power consumption:
(including capsule unit & operation panel unit & microphone phantom power)
90VA in UPS battery charge
50VA in normal operation
(3) Size:
(4) Mass:
(5) Color:
419.5(w) x 250(d) x 480(h) mm
23.0kg (NDV-1800), 21.0kg (NDV-1850)
N7 semi-gloss texture
18
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.3.7. NSK interface (VDR: option, S-VDR: standard)
(1) Function:
(2) Performance: a) Signal input: b) Recoding data:
Records gyro compass signal (Synchro / Step) and/or Ship’s speed log signal as IEC61162-1 sentence formatter
Synchro signal for Gyro compass
Ratio: 360X, 180X, 90X, 36X, 1X
Primary voltage: AC50 – 115V, 50/60Hz
Secondary voltage: AC20 – 90V, 50/60Hz
Step signal for Gyro compass
Ratio: 360X, 180X, 90X, 36X, 1X
Voltage: DC24V / 35V / 50V / 70V
Pulse signal for speed log
Pulse number: 200P / 400P / 100P / 160P (per NM)
Interface: Opto-Isolation / dry contact signal
Data type: IEC61162-1
Heading Sentence formatter: HDT
Sip speed Sentence formatter: VBW
1.10.3.8. Radar switching recording function
Specification of radar switching recording function when connecting two radars is as follows:
(1) Function: a) The radar screen in operation is automatically identified and recorded.
Automatic identification can be performed by monitoring the operation conditions of the scanners, which can be judged by the original sentences conforming to IEC61162 outputted from JRC radars. b)Switching recording function is only available when JRC radars are connected.
The radars corresponding to this switching recording function are the current models or newer (JMA-5300,
JMA-9900, JMA-900M). The older models do not correspond.
(2) Performance:
Radar switching recording function supports for connecting two non-JRC radars (refer to 2 and 3 below).
However, for non-JRC radars, we do not recommend using switching recording function because automatic identification of the working radar is not functional under the normal operation conditions.
For using switching recording function in the case of non-JRC radars, read the following specification for proper recording of the working radar images. a) Current JRC radars (JMA-5300, JMA-9900, JMA-900M)
Operation conditions of scanners are monitored by the sentences conforming to IEC61162 outputted from
X-band radars. When the scanner of X-band radar is in operation, the radar image connecting to CH1 will be recorded. When the scanner of X-band radar is not in operation, the radar image connecting to CH2 will be recorded. b) Switching SW connection
Recording modes can be selected by connecting the switching SW of the following specification to the dry contact input (PI_1 and PI_2 of TB406) of Recording Control Unit (RCU).
¾
AUTO mode: Images of CH to which the synchronized signals are outputted are automatically selected and recorded. If the synchronized signals are outputted from both CH1 and CH2, CH1 has the priority to be selected.
19
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
¾ CH1 recording mode: Images of CH1 are forced to be recorded.
If no images are inputted to CH1, the image data will not be recorded.
¾ CH2 recording mode: Images of CH2 are forced to be recorded.
If no images are inputted to CH2, the image data will not be recorded.
PI_1(TB406) PI_ 2(TB406) RADAR Recording Mode
OPEN OPEN AUTO
CLOSE OPEN CH2
When in operation by AUTO mode, the objective radar images will be recorded if the power of nonoperational radar is turned off. If the nonoperational radar is set standby, outputting radar images is not stopped and therefore, only the X-band radar screen without any echoes will be recorded. c) Continuous AUTO mode
When the switching SW is not connected and two radars are connected, images will be recorded continuously by AUTO mode.
1.10.4. Operation Panel Unit: OPU (NCG-169)
(1) Function:
(2) Performance: a) Type: b) Power supply: c) Indication: d) Operation:
(3) NSK operation:
a) Operation
b) Indication
(4) Environmental condition: a) Operating temperature: b) Temperature and humidity: c) Vibration:
(5) General specification: a) Size: b) Mass: c) Color:
Visible indication and audible alarm for VDR system alarm in the Wheelhouse
Display of the cause of an error
Input of Heading initial value
Flush mount type or Wall mount type
Supplied from the Recording Control Unit NDV-1800/1850
LED lighting for alarm indication
4 digit LED for error code indication
Buzzer (mutable by ACK switch)
Alarm acknowledgement
Dimmer of LED
(When the NSK interface board is added.)
Entry of the initial value of heading
Heading value indication
-15
°C to +55°C (IEC 60945 protected type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
145(w) x 50(d) x 165(h) mm
0.3kg
N4 semi-gloss texture
20
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.5. Microphone Unit (NVT-161)
(1) Function:
(2) Performance: a) Type: b) Device: c) Directivity: d) Receiving range: e) Power supply: f) Test device:
(3) Environmental condition: a) Operating temperature: b) Temperature and humidity: c) Vibration:
(4) General specification a) Size: b) Mass: c) Color:
Acquisition of W/H conversation, Alarms and sounds etc. in W/H
Ceiling mount type, wall mount type
Electoret condenser microphone
Hemispherical and omnidirectional
2.5m of radius
Phantom powered by 12VDC
Built-in speaker for audio acquisition test
-15
°C to +55°C (IEC 60945 protected type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
110(w) x 44.5(d) x 160(h) mm
0.2kg
N4 semi-gloss texture
1.10.6. Waterproof Microphone Unit (NVT-162) -Option-
(1) Function:
(2) Performance: a) Type: b) Device: c) Directivity: d) Receiving range: e) Power supply: f) Test device:
(3) Environmental condition: a) Operating temperature: b) Temperature and humidity: c) Vibration: d) Waterproof grade:
(4) General specification a) Size: b) Mass: c) Color:
Acquisition of wing conversation etc.
Wall mount type
Electoret condenser microphone
Hemispherical and omnidirectional
2.5m of radius
Phantom powered by 12VDC
Built-in speaker for audio acquisition test
-25
°C to +55°C (IEC 60945 exposed type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
IPx6
126(w) x 93(d) x 110(h) mm
1.2kg
N7 semi-gloss
21
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.7. Digital Signal Converter (NCT-72) 64CH -Option-
(1) Function:
(2) Performance: a) Dry contact Input port: b) Contact closure interface:
1) Driving power supply:
2) Status: c) Communication port d) Data output interface
(3) Optional Analog interface: a) Analog signal Input port: b) Signal input:
1) Voltage:
2) Current: c) Communication port d) Data output interface
(4) Environmental condition: a) Operating temperature: b) Temperature and humidity: c) Vibration:
(5) General specification a) Power voltage: b) Power consumption: c) Size: d) Mass:
The Digital signal converter should acquire alarms or status condition via dry contact closure.
Dry (voltage free) contact closure
Max. 64 port
+12VDC
Normal Close / Normal open
To the NDV-1800 RCU
Data type: IEC61162-1
(When the optional Analog signal converting board CEF-60 is added.)
Max. 8 port
+/-500mV, +/-5V, +/-10V
+/-20mA
Same port as dry contact signals
Data type: IEC61162-1
Analog Sentence formatter: XDR
-15
°C to +55°C (IEC 60945 protected type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
25VA
300(w) x 130(d) x 420(h) mm
5kg e) Color: N7 semi-gloss
1.10.8. Digital Signal Converter (NCT-63) 16CH -Option-
(1) Function:
(2) Performance: a) Dry contact Input port: b) Contact closure interface:
1) Driving power supply:
2) Status: c) Communication port d) Data output interface
(3) Optional Analog interface: a) Analog signal Input port: b) Signal input:
1) Voltage:
The Digital signal converter should acquire alarms or status condition via dry contact closure.
Dry (voltage free) contact closure
Max. 16 port
+12VDC
Normal Close / Normal open
To the NDV-1800 RCU
Data type: IEC61162-1
(When the optional Analog signal converting board CEF-60 is added.)
Max. 8 port
+/-500mV +/-5V +/-10V
22
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
2) Current: c) Communication port d) Data output interface
(4) Environmental condition: a) Operating temperature: b) Temperature and humidity: c) Vibration:
(5) General specification a) Power voltage: b) Power consumption: c) Size: d) Mass:
+/-20mA
Same port as dry contact signals
Data type: IEC61162-1
Analog Sentence formatter: XDR
-15
°C to +55°C (IEC 60945 protected type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
25VA
300(w) x 130(d) x 230(h) mm
2.9kg e) Color: N7 semi-gloss
1.10.9. Radar Interface Unit (NWP-46) -Option-
(1) Function:
The NWP-46 is required when a high resolution (UXGA) radar display is connected to the VDR/S-VDR.
The NWP-46 is an option unit in order to install a FGB near the radar, because high resolution RGB signals can not be extended to the VDR/S-VDR,
The Frame Grabber Board (FGB) in the NWP-46 is moved from the Recording
Control Unit.
(2) Performance: a) Basic performance: b) Communication port
(3) Environmental condition: a) Operating temperature: b) Temperature and humidity: c) Vibration:
(4) General specification a) Power voltage: b) Power consumption: c) Size: d) Mass: e) Color:
It is the same as the Radar image input specification of the Recording Control
Unit.
To the NDV-1800/1850 RCU via Ethernet
-15
°C to +55°C (IEC 60945 protected type)
+40
°C, 93%
2Hz to 13.2Hz
±1.0mm
13.2Hz to 100Hz 0.7G
100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
10VA
255(w) x 160(d) x 72(h) mm
1.5kg
N4 semi-gloss
23
DOC No. 7ZPJD0387C
1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
This page is intentionally left blank
DOC No. 7ZPJD0387C
24
advertisement
Key Features
- Records navigation, communication, and other critical data for voyage analysis
- Provides high-capacity storage for extended recording durations
- Complies with IMO and IEC 61996-1/2 standards for regulatory compliance
- Features an intuitive user interface for ease of operation
- Supports remote maintenance and diagnostics for efficient troubleshooting
- Offers GPS synchronization for accurate timekeeping
Questions & Answers
S S B
What does alarm code 31 indicate?
Related manuals
Frequently Answers and Questions
What types of data does the JRC JCY-1800 record?
How long can the JRC JCY-1800 record data for?
Does the JRC JCY-1800 comply with international regulations?
advertisement
Table of contents
- 11 SPECIFICATIONS
- 11 Outline of the Equipment
- 11 Feature of new VDR/S-VDR
- 11 Common features in VDR/S-VDR
- 11 VDR (JCY-1800)
- 12 S-VDR (JCY-1850)
- 12 Option Unit
- 12 Points of Instruction
- 13 Operation of inputting two Radar images
- 14 Difference between VDR and S-VDR
- 14 Main Specifications
- 14 System components
- 15 JCY-1800 Configuration
- 16 JCY-1850 Configuration
- 18 Present and New model Comparison table
- 18 VDR
- 19 S-VDR
- 20 JCY-1800 System Diagram
- 21 JCY-1850 System Diagram
- 22 Functions of electrical circuit board
- 24 Specifications of each unit
- 24 Protective Capsule Unit: PCU (NDH-316)
- 25 Protective Capsule Unit: PCU (NDH-317)
- 26 Recording Control Unit: RCU (NDV-1800/1850)
- 26 Operation Panel (Internal)
- 26 Data Processor Unit
- 28 Power Supply Unit
- 28 External Interface
- 28 Environmental condition
- 28 General specification
- 29 NSK interface (VDR: option, S-VDR: standard)
- 29 Radar switching recording function
- 30 Operation Panel Unit: OPU (NCG-169)
- 31 Microphone Unit (NVT-161)
- 31 Waterproof Microphone Unit (NVT-162) -Option-
- 32 Digital Signal Converter (NCT-72) 64CH -Option-
- 32 Digital Signal Converter (NCT-63) 16CH -Option-
- 33 Radar Interface Unit (NWP-46) -Option-
- 35 INSTALLATION PROCEDURES
- 35 General Installation Procedures
- 36 Points of installation
- 36 Capsule
- 36 Operation panel unit
- 36 Microphone unit
- 36 Radar Image
- 37 Serial data(NMEA)
- 37 Option unit
- 38 Switching Radar
- 39 GPS selection
- 39 Radar Interface Unit NWP-46
- 41 FGB Kit (7ZZJD0052) Installation Procedure
- 41 Components
- 41 Installation procedure
- 44 Setup procedure
- 44 Check a Radar image
- 45 MECHANICAL INSTALLATION
- 45 Protective Capsule: NDH-316/317
- 45 Selecting the Location
- 45 Installing the Capsule
- 45 Mounting the Capsule
- 47 Fastening the Capsule
- 48 Vicinity clearance of the Capsule: NDH-316 / NDH-317
- 49 Connection Box: NQE-3163
- 49 Selecting the Location
- 49 Mounting the Connection Box
- 50 Mounting the Connection Box of VDR (JCY-1800)
- 51 Mounting the Connection Box of S-VDR (JCY-1850)
- 52 Recording Control Unit: NDV-1800 / NDV-1850
- 52 Selecting the Location
- 52 Fastening the Recording Control Unit
- 52 Connecting Cables
- 52 Vicinity Clearance of the Recording Control Unit
- 52 Fastening the Recording Control Unit
- 55 Operation Panel Unit: NCG-169
- 55 Selecting the Location
- 55 Recommended Location
- 55 Note on selection
- 55 Fastening the Operation Panel Unit
- 57 Microphone Unit: NVT-161
- 57 Selecting the Location
- 57 Recommended Location
- 57 Notes on selection
- 57 Fastening a Microphone Unit
- 59 Waterproof Microphone Unit: NVT-162 (Option)
- 59 Selection of mounting location
- 59 Recommended Location
- 59 Note on selection
- 59 Fastening a Waterproof Microphone Unit
- 61 Digital Signal Converter: NCT-72 - 64ch - (VDR Option)
- 61 Selecting the Location
- 61 Fastening the Digital Signal Converter
- 61 Connecting Cables
- 61 Vicinity Clearance of a Digital Signal Converter
- 61 Fastening a Digital Signal Converter
- 63 Digital Signal Converter: NCT-63 - 16ch - (VDR Option)
- 63 Selecting the Location
- 63 Fastening the Digital Signal Converter
- 63 Connecting Cables
- 63 Vicinity Clearance of a Digital Signal Converter
- 63 Fastening a Digital Signal Converter
- 65 Radar Interface Unit: NWP-46 (Option)
- 65 Selecting the Location
- 65 Fastening the Radar Interface Unit
- 65 Connecting Cables
- 65 Fastening a Radar Interface Unit
- 67 Connection to the JMA-900 Chart Radar Unit
- 67 Fastening the Radar Interface Unit on the JMA-900 Chart Rada
- 69 Edit a setup file of a Chart Radar (JMA-900M series) to outp
- 69 Check the function
- 71 CABLING
- 71 Cabling of the Protective Capsule NDH-316/317
- 71 Protective Capsule NDH-316/317 – Connection Box NQE-3163
- 72 Cabling of the Recording Control Unit NDV-1800/1850
- 72 Recording Control Unit NDV-1800/1850 –Connection Box NQE-316
- 73 Recording Control Unit NDV-1800/1850 – Operation Panel Unit
- 73 Recording Control Unit NDV-1800/1850 – Microphone Unit NVT-1
- 74 Recording Control Unit NDV-1800/1850 – Waterproof Microphone
- 74 Recording Control Unit NDV-1800/1850 – VHF Radio telephone e
- 74 Recording Control Unit NDV-1800/1850 – RADAR video
- 75 Signal format of RADAR video
- 76 Monitor Timing of the RADAR Video
- 77 Connectability of JRC RADAR Series
- 80 Recording Control Unit NDV-1800/1850 – Sensor NMEA data
- 81 Recording Control Unit NDV-1800/1850 – Digital Signal Conver
- 82 Recording Control Unit NDV-1800/1850 – Gyro output the Synch
- 83 Recording Control Unit NDV-1800/1850 – Speed log output the
- 83 Recording Control Unit NDV-1800/1850 – Emergency Power Distr
- 84 Recording Control Unit NDV-1800/1850 – External Alarm Lamp
- 84 Recording Control Unit NDV-1800/1850 – External Alarm Buzzer
- 85 Recording Control Unit NDV-1800/1850 – GPS Switch/RADAR Swit
- 86 Cabling of the Digital Signal Converter NCT-72 / 63 (VDR opt
- 86 Digital Signal Converter NCT-72/63 – Dry contacts output Equ
- 87 Digital Signal Converter NCT-72/63 – Analog output Sensors (
- 88 Digital Signal Converter NCT-72/63 – Recording Control Unit
- 89 Cabling of the Radar Interface Unit NWP-46 (VDR option)
- 89 Radar Interface Unit NWP-46 – Radar Unit (UXGA resolution)
- 90 Radar Interface Unit NWP-46 – Recording Control Unit NDV-180
- 91 Assembling an Ethernet Connector (RJ-45 type)
- 91 Assemble outside sheath of an Ethernet cable
- 91 How to assemble an Ethernet connector
- 97 INSTRUCTION
- 97 Recording Control Unit (NDV-1800 / 1850)
- 97 Names of Parts of the Recording Control Unit (NDV-1800 / 185
- 99 Power Supply Unit
- 99 Names and functions of each part of the Power Supply Unit
- 99 How to operate the Power Supply Unit
- 101 Data Processor Unit
- 101 Names of each part of the Data processor Unit
- 103 How to operate the Data Processor Unit
- 104 Operation Panel Unit (NCG-169)
- 104 Names and functions of each part of the External Operation B
- 105 How to operate the Operation Panel Unit (Normal mode)
- 107 How to operate the Operation Panel Unit (on NSK mode)
- 109 SETTING
- 109 Recording Control Unit (NDV-1800/1850) setup
- 109 Digital Signal Converter (NCT-72/63) setup
- 110 Analog Signal Converting Board (CEF-60) setup
- 111 Main Control Board (CDJ-2304) /(RMB: CDK-287) DIP-SW setting
- 112 Frame Grabber Board (CKA-129) Strap and DIP-SW setting
- 113 ERROR DISPLAY
- 113 Recording Control Unit (NDV-1800/1850)
- 113 Power Supply Unit
- 113 Data Processor Unit
- 113 Operation Panel Unit (NCG-169)
- 117 TROUBLESHOOTING
- 117 The Recording Control Unit (NDV-1800/1850)
- 117 Symptom Table for The Power Supply Unit (NBL-327)
- 118 Symptom Table for The Data Processor Unit (NDL-46)
- 119 The Operation Panel Unit (NCG-169)
- 123 LED Display of LAN Connector
- 123 Recording Control Unit NDV-1800/1850
- 125 MAINTENANCE
- 125 Parts list for Maintenance
- 126 How to replace the fans
- 127 How to replace the battery
- 129 Checking a Connection cable in the RCU
- 129 Cable list
- 129 Signals of Each cables
- 131 Connection table of each Terminals
- 135 CONNECTION BLOCK DIAGRAMS
- 135 System Diagram
- 135 VDR JCY-1800
- 136 S-VDR JCY-1850
- 137 Interconnection Wiring Diagrams
- 137 NDV-1800/1850 Recording Control Unit – Page 1 -
- 141 NQE-3163 Connection Box
- 142 NVT-161 / NVT-162 Microphone Unit / Waterproof Microphone un
- 143 VHF Line Connection
- 144 NCG-169 Operation Panel Unit
- 145 NCT-72 Digital Signal Converter – Page 1 -
- 148 NCT-63 Digital Signal Converter – Page 1 -
- 150 NWP-46 Radar Interface Unit
- 151 SCHEMATIC DIAGRAMS (CIRCUIT DIAGRAMS)
- 151 NDV-1800 Recording Control Unit of VDR
- 152 NDV-1850 Recording Control Unit of S-VDR
- 153 NCG-169 Operation Panel Unit
- 154 NVT-161 Microphone Unit
- 155 NVT-162 Waterproof Microphone Unit (Option)
- 156 NCT-72 Digital Signal Converter 64CH (Option)
- 157 NCT-72 Digital Signal Converter 64CH + A/D Option Board (Opt
- 158 NCT-63 Digital Signal Converter 16CH (Option)
- 159 NCT-63 Digital Signal Converter 16CH + A/D Option Board (Opt
- 160 NWP-46 Radar Interface Unit (Option)
- 161 CONFIGURATION OF CONNECTION INTERFACE
- 161 Ship Identification Information
- 161 Ship Specification Information (for reference to installatio
- 161 Other Ships’ Information
- 162 List of Equipment and Connection interface
- 162 IEC61162-1/2 Connection Interface
- 163 Connection Interface for Audio Signal equipment
- 163 Bridge Audio
- 163 VHF Communication audio
- 164 RADAR Signal Contact Interface
- 164 Dry Contact Signal Connection Interface (For NCT-72(64CH)/63
- 165 Recording Data
- 165 Timing of Data Acquisition
- 165 Recording Capacity
- 166 Memory Assignment of Each Data Format
- 167 SPARE PARTS
- 167 Spare Parts List for the Recording Control Unit NDV-1800/185
- 168 Spare Parts List for the Digital Signal Converter NCT-72/63
- 169 Spare Parts List for the Radar Interface Unit NWP-46
- 171 MAINTENANCE CHECK LIST FOR VDR/S-VDR
- 185 ANNUAL INSPECTION
- 185 Declaration on completion of annual inspection for VDR
- 186 Declaration on completion of annual inspection for S-VDR
- 187 Annual Inspection Procedures
- 193 INSPECTION CHEC LIST FOR VDR/S-VDR