WPIM Cable Specifications
WPIM-SY
This section provides the Cabletron Systems part number and connector specifications for the
WPIM-SY interface cables.
Table 29 provides the cable and interface types, electrical types, and part numbers for the
WPIM-SY.
Table 29 WPIM-SY Interface Cables
Cable and Interface Type
RS449
V.35
RS232
X.21
RS530
RS530 ALT A
RS530A
RS530A ALT A
Electrical Type
RS422
V.35
RS232
X.21
RS422
RS422
RS422
RS422
Part Number
9380120
9380121
9380122
9380123
9380124
9380125
9380126
9380127
CSX200 Family User’s Guide 215
WPIM Cable Specifications
EIA-449
Table 30 shows the connector number, cable assembly description, and connector type.
Table 30 EIA-449 Interface
Connector Number Cable Assembly Description Connector Type
1
2
EIA-530A ALT A to EIA-449
Sub DB 26-pin male connector
DB-37 pin male connector
Table 31 provides pin assignments for the EIA-449 interface cable.
Table 31 EIA-449 Interface Cable Pin Assignment
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
DB
DD
DA
DCE
DTE
DCE
DTE
DCE
PIN
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B
Clear to Send A
Clear to Send B
Request to Send A
Request to Send B
Transmit Signal Timing A 15
Transmit Signal Timing B 12
Receive Signal Timing A 17
Receive Signal Timing B 9
Transmit Signal Timing A 24
Transmit Signal Timing B 11
5
13
4
19
2
14
3
16
PAIR
A
B
C
D
E
F
G
PIN
Connector 2 EIA-449
NAME
4
22
Send Data A
Send Data B
6 Receive Data A
24 Receive Data B
9 Clear to Send A
27 Clear to Send B
7 Request to Send A
25 Request to Send B
5 Send Timing A
23 Send Timing B
8 Receive Timing A
26 Receive Timing B
17 Terminal Timing A
35 Terminal Timing B
DIRECT
TO
MNEMONIC
DCE
DTE
DCE
DTE
DCE
SD
RD
CS
RS
ST
RT
TT
216 CSX200 Family User’s Guide
WPIM Cable Specifications
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
CE
TM
CC
CD
AC
DTE
DCE
Ring Indicator
Test Mode
DCE Ready
DTE Ready
SHIELD
Signal Common
AB
Table 31 EIA-449 Interface Cable Pin Assignment (Continued)
Signal Common
PIN
22
25
6
20
1
23
7
PAIR
PIN
Connector 2 EIA-449
NAME
DIRECT
TO
MNEMONIC
15
18
Incoming Call
Test Mode
11 Data Mode
12 Terminal Ready
20 Receive Common
19
30
37
Send Common
Terminal Ready B
Signal Ground
DTE
DCE
IC
TM
DM
TR
RC
SG
TR_B
SC
V.35
Table 32 shows the connector number, cable assembly description, and connector type.
Table 32 V.35 Interface
Connector Number Cable Assembly Description
1
2
EIA-530A ALT A to V.35
Connector Type
Sub DB 26-pin male
M Series 34-pin male
Table 33 provides pin assignments for the V.35 interface cable.
Table 33 V.35 Interface Cable Pin Assignment
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
PIN
DCE
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B DTE
Clear to Send A 5
DCE Request to Send A 4
2
14
3
16
PAIR
A
B
PIN
Connector 2 V.35
NAME
P Transmit Data A
S Transmit Data B
R Receive Data A
T Receive Data B
DIRECT
TO
MNEMONIC
DCE
DTE
C D Ready to Send A
D C Request to Send A DCE
103
104
106
105
CSX200 Family User’s Guide 217
WPIM Cable Specifications
Table 33 V.35 Interface Cable Pin Assignment (Continued)
RL
LL
AC
AB
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
DB
DD
DA
CE
TM
CC
CD
DTE
DCE
DTE
DCE
NAME
Transmit Signal
Timing A
Transmit Signal
Timing B
Receive Signal
Timing A
Receive Signal
Timing B
Transmit Signal
Timing A
Transmit Signal
Timing B
Ring Indicator
Test Mode
DCE Ready
DTE Ready
Remote Loopback
Local Loopback
SHIELD
Signal Common
Signal Common
PIN
PAIR
15
12
17
9
24
11
22
25
6
20
21
18
1
23
7
E
F
G
PIN
Connector 2 V.35
NAME
DIRECT
TO
MNEMONIC
Y
AA
V
X
Transmitter Signal
Timing A
Transmitter Signal
Timing B
Receiver Signal
Timing A
Receiver Signal
Timing B
U
W
Transmitter Signal
Timing A
Transmitter Signal
Timing B
J Calling Indicator
NN Test Indicator
E Data Set Ready
H
N
Data Terminal
Ready
Loopback
Maintenance
L Local Loopback
DRAIN
B Signal Common
B Signal Common
DTE
DCE
DTE
DCE
114
115
113
125
142
107
108
140
141
102
102
218 CSX200 Family User’s Guide
WPIM Cable Specifications
EIA-232
Table 34 shows the connector number, cable assembly description, and connector type.
Table 34 EIA-232 Interface
Connector Number Cable Assembly Description
1
2
EIA-530A ALT A to EIA-232
Connector Type
Sub DB 26-pin male
DB-25 pin male
Table 35 provides pin assignments for the EIA-232 interface cable.
Table 35 EIA-232 Interface Cable Pin Assignment
BA
BB
CB
CA
DB
DD
DA
CE
RL
LL
TM
CC
CD
AC
AB
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME PIN PIN
Connector 2 EIA-232
NAME
DIRECT
TO
MNEMONIC
DCE DCE
DTE
DCE
DTE
DCE
DTE
DCE
Transmit Data
Receive Data
Clear to Send
Request to Send
Transmit Signal Timing
Receive Signal Timing
2 2
3 3
Transmit Data
Receive Data
5 5 Clear to Send
4 4 Request to Send
15
17
15
17
Transmitter Signal
Timing
Receiver Signal
Timing
Transmit Signal Timing
Ring Indicator
Remote Loopback
24
22
21
24
22
21
Transmitter Signal
Timing
Ring Indicator
Loopback
Maintenance
DTE
DCE
Local Loopback
Test Mode
DCE Ready
DTE Ready
SHIELD
Signal Common
Signal Common
18 18 Local Loopback
25 25 Test Indicator
6 6
20 20
DCE Ready
DTE Ready
1
23 7 Signal Common
7 7 Signal Common
DTE
DCE
DTE
DCE
DTE
DCE
DTE
DCE
BA
BB
CB
CA
DB
DD
DA
CE
RL
LL
TM
CC
CD
AB
AB
CSX200 Family User’s Guide 219
WPIM Cable Specifications
X.21
Table 36 shows the connector number, cable assembly description, and connector type.
Table 36 X.21 Interface
Connector Number Cable Assembly Description Connector Type
1
2
EIA-530A ALT A to X.21
Sub DB 26-pin male
DB-15 pin male
Table 37 provides pin assignments for the X.21 interface cable.
Table 37 X.21 Interface Cable Pin Assignment
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
DB
AC
AB
DCE
DTE
DTE
DCE
DTE
PIN
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B
Clear to Send A
Clear to Send B
Request to Send A
Request to Send B
Transmit Signal Timing A
Receive Signal Timing A
Transmit Signal Timing B
Receive Signal Timing B
SHIELD
DTE Common
DCE Common
1
7
23
5
13
4
19
17
15
9
12
2
14
3
16
PAIR
A
B
C
D
E
PIN
6
13
8
5
12
3
10
2
9
4
11
Signal Ground
Connector 2 X.21
NAME
DIRECT
TO
MNEMONIC
Transmit A
Transmit B
Receive A
Receive B
Indication A
Indication B
Control A
Control B
DCE
DTE
DTE
DCE
Signal Element
Timing A
DTE
Signal Element
Timing B
DRAIN
T
R
I
C
S
G
220 CSX200 Family User’s Guide
WPIM Cable Specifications
EIA-530, EIA-530 ALT A, EIA-530 A, and EIA-530 A ALT A
Table 38 shows the connector number, cable assembly description, and connector type for the
EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A, interface cables.
Table 38 EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A Interfaces
Connector Number Cable Assembly Description Connector Type
1
2
1
2
1
2
1
2
EIA-530A ALT A to EIA-530
EIA-530A ALT A to EIA-530 ALT A
EIA-530A ALT A to EIA-530A
EIA-530A ALT A to EIA -530A ALT A
Sub DB 26-pin male
DB 25-pin male
Sub DB 26-pin male
Sub DB26-pin male
Sub DB 26-pin male
DB 25-pin male
Sub DB 26-pin male
Sub DB 26-pin male
Table 39 provides the cable pin assignments for the EIA-530, EIA-530 ALT A, EIA-530A, and
EIA-530A ALT A, interface cables.
Table 39 EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A Interface Cable Pin Assignments
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
DCE
DTE
DCE
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B
Clear to Send A
Clear to Send B
Request to Send A
Request to Send B
PIN
2
14
3
16
5
13
4
19
PAIR
A
B
C
D
PIN
Connector 2 EIA-530
NAME
DIRECT
TO
MNEMONIC
2 Transmit Data A
14 Transmit Data B
3 Receive Data A
16 Receive Data B
5 Clear to Send A
13 Clear to Send B
4 Request to Send A
19 Request to Send B
DCE
DTE
DCE
BA
BB
CB
CA
CSX200 Family User’s Guide 221
WPIM Cable Specifications
Table 39 EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A Interface Cable Pin Assignments a b
DB
DD
DA
RL
LL
TM
CC
CD
AC
AC
AB
CE
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
DTE
DCE
DTE
DCE
DTE
NAME
Transmit Signal Timing A 15
Transmit Signal Timing B 12
Receive Signal Timing A 17
Receive Signal Timing B
Remote Loopback
SHIELD
Local Loopback
Test Mode
DCE Ready
DTE Ready
Signal Common
Signal Common
Signal Common
Ring Indicator
PIN
PAIR
9
Transmit Signal Timing A 24
Transmit Signal Timing B 11
21
18
25
6
20
1
23
23
7
22
E
F
G
PIN
Connector 2 EIA-530
NAME
DIRECT
TO
MNEMONIC
15
12
17
9
Transmit Signal
Timing A
Transmit Signal
Timing B
Receive Signal
Timing A
Receive Signal
Timing B
7 Signal Common
23 Signal Common
7 Signal Common
22 Ring Indicator
DTE
24
11
Transmit Signal
Timing A
Transmit Signal
Timing B
DCE
21 Remote Loopback
18 Local Loopback
25
6
20
Test Mode
DCE Ready
DTE Ready
DRAIN
DTE
DCE
DTE
DB
DD
DA
RL
LL
TM
CC
CD
AC
AC
AB
CE a. This pin assignment only applies to the EIA-530A ALT A interface cable.
b. This pin assignment only applies to the EIA-530A and EIA-530A ALT A interface cables.
222 CSX200 Family User’s Guide
advertisement
Related manuals
advertisement
Table of contents
- 15 Related Documentation
- 15 How to Use This Guide
- 17 Document Conventions
- 18 Getting Help
- 19 CSX200 Hardware
- 19 WAN Connection
- 21 Ethernet LAN Connection
- 22 Remote Management Capabilities
- 22 Optional Features
- 22 CSX200 Firmware Support
- 23 IEEE 802.3 Ethernet
- 23 WAN Protocols
- 24 Firmware Data Compression
- 24 HDLC
- 24 DHCP and NAT
- 25 Point-to-Point Protocol (PPP)
- 25 PAP and CHAP Security
- 26 LQM
- 26 HDSL
- 27 Bridging and Routing
- 29 Bridging and Routing Protocol Filtering
- 30 System Passwords
- 30 Simple Network Management Protocol (SNMP)
- 31 SNMP MIB Support
- 31 Enterasys Enterprise MIBs
- 32 SNMP Trap Support
- 34 Software and Firmware Upgrades
- 35 Network Requirements
- 35 10BASE-T Twisted Pair Network
- 36 Port Descriptions
- 36 10BASE-T LAN Configuration
- 37 Connecting UTP Cables to Ports 1 Through 12
- 39 Unpacking the CSX200
- 39 Guidelines for Installations
- 40 Installing Interface Modules
- 40 Removing the CSX200 Cover
- 42 Installing the WAN Port Interface Module (WPIM)
- 43 CSX200-COMP/ENCR Installation
- 45 Installing the CSX200
- 45 Tabletop and Shelf Installations
- 46 CSX200 Rackmount Installation
- 46 Tools Required
- 46 Materials Required
- 47 Attaching the Strain-Relief Bracket
- 48 Attaching the Rackmount Brackets
- 48 Installing the CSX200 in a 19-Inch Rack
- 49 Connecting the CSX200 to the Power Source
- 54 Ethernet Configuration
- 54 Ethernet Configuration Window
- 58 Wide Area Configuration
- 59 Wide Area T1 Configuration Window
- 62 Wide Area E1 Configuration Window
- 64 Wide Area DI Configuration Window
- 67 Wide Area Synchronous Configuration Window
- 70 Wide Area DDS Configuration Window
- 72 Wide Area HDSL Configuration Window
- 74 Wide Area Frame Relay Time Slot Configuration Wind...
- 75 Wide Area PPP Time Slot Configuration Window
- 77 Wide Area HDSL Time Slot Configuration Window
- 78 Bridging and Routing Configuration
- 78 Bridging and Routing Configuration Window
- 79 The Firewall Configuration Window
- 84 Bridging and Routing (WAN Frame Type) Configuratio...
- 86 Routing Configuration Window
- 87 IP Routing Configuration
- 87 IPX Routing Configuration
- 88 Host Map Window
- 90 Advanced Routing Configuration Window
- 91 Advanced IP Routing Settings
- 91 Advanced IP Routing Options
- 91 Redirector Window
- 92 DHCP Settings Configuration Window
- 94 NAT Settings Configuration Window
- 96 QuickSET Pull-Down Menus
- 96 File Menu
- 98 Firmware Upgrade Menu
- 100 Advanced Configuration Menu
- 101 Compression & Congestion Window
- 103 Chapter Organization
- 104 Local Management Overview
- 104 Management Agent
- 104 Local vs. Remote Management
- 105 Local Management Screen Elements
- 107 Local Management Keyboard Conventions
- 108 Navigating Within Local Management Screens
- 108 Establishing a TELNET Connection
- 109 Hierarchy and Organization of Local Management Scr...
- 109 Selecting Local Management Menu Screen Items
- 109 Exiting Local Management Screens
- 110 Exiting the Local Management Session
- 111 Accessing Local Management
- 111 Using the Menu Screens
- 112 Main Menu Screen
- 113 Setup Menu Screen
- 115 System Level Screen
- 117 Setting the System Date
- 117 Setting the System Time
- 118 Setting the Host IP Address
- 118 Setting the Default Gateway
- 119 Setting the Subnet Mask
- 119 Setting the Default Interface
- 120 SNMP Community Names Screen
- 120 Community Name Access Policy
- 121 Setting SNMP Community Names
- 122 SNMP Traps Screen
- 122 Trap Table Screen Fields
- 123 Setting the SNMP Trap Destination
- 124 Flash Download Screen
- 125 Selecting a Flash Download Method
- 126 RUNTIME Download
- 126 BOOTPROM Download
- 127 Bridge Setup Screen
- 128 Bridge Setup Screen Fields
- 128 Selecting a Spanning Tree Protocol
- 128 Selecting the Bridge Port Administrative Status
- 129 Selecting the Bridge Port Pair Administrative Stat...
- 130 Router Setup Screen
- 130 Router Setup Fields
- 131 IP Configuration Screen
- 131 IP Configuration Screen Fields
- 132 IP General Config Screen
- 132 IP General Configuration Status Fields
- 133 IP General Configuration Fields
- 134 Selecting a Port for Configuration
- 134 Entering the IP Address and Subnet Mask
- 134 Selecting the Frame Type for a Port
- 135 Setting the Maximum Transmission Unit (MTU)
- 135 Enabling IP Routing Services on a Port
- 135 Enabling IP Forwarding on a Port
- 136 Configuring the UDP Broadcast Redirector
- 137 Enabling Proxy ARP on a Port
- 138 Configuring the Network Broadcast Type on a Port
- 138 Enabling the RIP Routing Protocol on a Port
- 140 IPX Configuration Screen
- 140 IPX Configuration Fields
- 141 IPX General Configuration Screen
- 141 IPX General Configuration Status Fields
- 142 IPX General Configuration Fields
- 142 Selecting a Port for Configuration
- 143 Entering the IPX Address
- 143 Selecting the Frame Type for a Port
- 143 Setting the Maximum Transmission Unit (MTU)
- 144 Enabling IPX Routing Services on a Port
- 144 Enabling IPX Forwarding on a Port
- 145 IPX Routing over Frame Relay
- 145 Enabling the IPX SAP Routing Protocol on a Port
- 147 Enabling RIP on a Port
- 149 Chapter Organization
- 150 T1 Physical Configuration
- 150 WAN Physical Configuration Screen Fields
- 151 T1 Configuration Fields
- 152 Time Slot Configuration Table
- 154 T1 Interface Configuration
- 154 T1 WAN Interface Configuration Screen Fields
- 156 Full T1 Configuration Using PPP
- 157 Full T1 Physical Configuration
- 158 Interface Configuration
- 159 Fractional T1 Configuration Using PPP
- 160 Fractional T1 Physical Configuration
- 161 Fractional T1 Interface Configuration
- 162 Frame Relay Configuration
- 163 Frame Relay Physical Configuration
- 164 Frame Relay Interface Configuration
- 165 Synchronous Physical Configuration
- 166 WAN Physical Configuration Screen Fields
- 166 Synchronous Configuration Fields
- 167 Synchronous Interface Configuration
- 168 WAN Interface Configuration Screen Fields
- 170 PPP Configuration
- 170 PPP Physical Configuration
- 171 PPP Interface Configuration
- 172 Frame Relay Configuration
- 172 Frame Relay Physical Configuration
- 173 Frame Relay Interface Configuration
- 174 DDS Physical Configuration
- 174 WAN Physical Configuration Screen Fields
- 175 WPIM-DDS Configuration Fields
- 176 DDS Interface Configuration
- 177 WAN Interface Configuration Screen Fields
- 179 DDS Configuration
- 180 DDS Physical Configuration
- 180 DDS Interface Configuration
- 182 HDSL Physical Configuration
- 183 WAN Physical Configuration Screen Fields
- 183 WPIM-HDSL Configuration Fields
- 184 HDSL Interface Configuration
- 184 WAN Interface Configuration Screen Fields
- 187 Chapter Organization
- 188 MIB Navigator Screen
- 188 Managing Device MIBs
- 189 MIB Navigator Command Set Overview
- 190 Conventions for MIB Navigator Commands
- 191 Navigation Commands
- 201 Other Commands
- 213 Special Commands
- 218 Troubleshooting CSX200 Hardware
- 218 Power (PWR) LED is OFF
- 218 Processor (CPU) LED is OFF
- 218 Processor (CPU) LED is RED
- 218 Troubleshooting the LAN
- 218 Collision (CLN) LED is RED
- 218 Link (LNK) LED is OFF
- 219 Troubleshooting the WAN
- 219 Link (LNK) LED is OFF
- 219 Link (LNK) LED is RED
- 219 Link (LNK) LED is AMBER
- 219 Status 1 (STS1) LED is OFF
- 219 WPIM-T1, WPIM-E1, WPIM-DI, or WPIM-DDS Installed i...
- 220 WPIM-SYNC Installed in CSX200
- 220 WPIM-HDSL Installed in CSX200
- 220 Status 1 (STS1) LED is RED
- 220 WPIM-T1, WPIM-E1, or WPIM-DI Installed in CSX200 i...
- 221 WPIM-HDSL Installed in CSX200
- 221 Status 1 (STS1) LED is AMBER
- 221 WPIM-DDS Installed in CSX200
- 221 Status 1 (STS1) LED is GREEN
- 221 WPIM-SYNC Installed in CSX200
- 222 WPIM-HDSL is installed in CSX200
- 222 Status 2 (STS2) LED is OFF
- 222 WPIM-T1, WPIM-E1, WPIM-DI, or WPIM-DDS Installed i...
- 222 WPIM-SYNC Installed in CSX200
- 222 WPIM-HDSL Installed in CSX200
- 222 Status 2 (STS 2) LED is RED WPIM-HDSL Installed in...
- 223 Status 2 (STS2) LED is AMBER
- 223 WPIM-T1, WPIM-E1, or WPIM-DI Installed in CSX200
- 223 Status 2 (STS2) LED is GREEN
- 223 WPIM-SYNC Installed in CSX200
- 223 WPIM-HDSL Installed in CSX200
- 224 Test (TST) LED is AMBER (blinking)
- 224 Investigating Software Configuration Problems
- 224 Connection to Device Fails During Software Configu...
- 224 User Cannot Communicate with Remote Network Statio...
- 224 If Bridging,
- 225 If TCP/IP Routing,
- 227 WPIM-T1
- 229 WPIM-SY
- 230 EIA-449
- 231 V.35
- 233 EIA-232
- 234 X.21
- 235 EIA-530, EIA-530 ALT A, EIA-530 A, and EIA-530 A A...
- 237 WPIM-DDS
- 238 WPIM-E1
- 240 WPIM-DI
- 241 WPIM-HDSL
- 244 CSX200 Regulatory Compliance
- 244 Individual WPIM Regulatory Compliance
- 244 WPIM-T1
- 245 WPIM-SY
- 245 WPIM-DDS
- 246 WPIM-E1
- 246 WPIM-DI
- 246 WPIM-HDSL
- 257 Numerics
- 257 B
- 257 C
- 257 D
- 257 E
- 257 F
- 257 G
- 257 H
- 257 I
- 258 K
- 258 L
- 258 M
- 258 N
- 258 P
- 258 R
- 259 S
- 259 T
- 259 U
- 259 W