advertisement
APPENDIX A: Troubleshooting
A.4 Upgrading the Series II Modem’s Firmware
The Series II Modem has a Flash PROM which contains firmware code for the hardware and DSP code for the digital signal processor chips. At various times, we may add enhancements and/or fixes to the firmware.
The flash technology used in the Series II Modem lets you load these upgrades into the PROM or DSP chips through the modem's serial port. If a Black Box Tech Support technician tells you that you need to upgrade your firmware, do so, taking these steps:
1.
Follow the technician’s instructions for downloading
FLASHPRO.ZIP and a new .HEX file from Black Box.
2. Unzip the FLASHPRO.ZIP file. Place this unzipped file and the
.HEX file in the same directory.
3. Run FlashPro by typing FLASHPRO, a space, -M and hitting
ENTER at the DOS prompt.
4. Highlight the "Configure" option in the MAIN MENU and hit
ENTER. Highlight "Active Port" and select the COM port to which you have your modem attached. Highlight "Baud Rate" and select the rate you want to program at. Hit ESC when finished.
5. Highlight the "Select File to Program" option in the MAIN MENU.
Highlight the .HEX file. Hit ESC when finished.
6. Highlight "Program Firmware" option in the MAIN MENU. When you are prompted to confirm the file to program, press "Y".
7. If you need more assistance programming FLASHPRO, then contact our tech support department again.
149
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 8 Introduction
- 8 How To Use This Manual
- 11 What is in Your Modem Package?
- 11 Modem Features
- 12 Fax Features
- 13 Technical Specifications
- 17 Power
- 17 Modem LED Indicators
- 19 Controls on PC Board
- 20 Safety Warnings
- 21 Installation
- 24 Is Your Series II Modem Ready for Use?
- 25 Operating Your Series II Modem
- 26 Simple Operations
- 26 The Answer/Originate - Voice/Data Toggle Switch
- 27 Introduction
- 27 Serial Port Limitations
- 28 How Can You Identify Your UART Type?
- 29 The 16550 UART and Windows
- 30 Configuring Your Software
- 30 Configuring Software for Your Modem
- 31 PC Initialization Strings
- 31 Changing Default Parameters
- 32 Other Parameters
- 32 Macintosh Initialization
- 33 Configuring Software for Your Computer
- 33 Configuring Software for the Remote System
- 34 Terminal Emulation
- 34 File Transfer Protocols
- 34 When to Disable Data Compression
- 35 Disabling Error Correction
- 36 Introduction
- 36 Dialing/On-Line/Answering
- 38 Auto. Leased Line Restoral Operation (336+ Only)
- 38 Manual Dial Backup Call Termination (336+ Only)
- 38 Dial Backup and Leased Line Restoral (336+ Only)
- 40 Dial-Up Operation (336+ Only)
- 40 Manual Call Origination
- 41 Automatic Answering
- 42 Manual Answering
- 42 Handshaking Details
- 43 Call Termination
- 45 Introduction
- 45 AT Command Editing
- 46 Functional Modes
- 47 Summary of AT Commands
- 51 Result Codes
- 53 Dialing Commands
- 53 Dialing Action Commands
- 55 Dial Modifier Commands
- 59 Phone Number Memory Commands
- 61 Configuration and Default Storage Commands
- 64 Command Response (Result Code) Commands
- 67 Phone Line Conditioning Commands
- 69 RS232C Interface Control Commands
- 71 Error Correction Commands
- 76 Flow Control Commands
- 82 Pass-Through and Pacing Commands
- 83 Speed Conversion Commands
- 86 Immediate Action Commands
- 91 Line Probe Commands
- 93 Introduction
- 103 Reading and Assigning S-Register Values
- 103 Examples of Assigning Values
- 104 Examples of Reading Values
- 104 AT Command and S-Register Summary
- 105 Introduction
- 105 Callback Feature Description
- 106 Remote Configuration Description
- 106 Configuration
- 112 Remote Configuration Procedures
- 113 Commands
- 115 Remote Configuration/Callback Security S-Registers
- 117 Introduction
- 118 Local Analog Loopback Test/V.54 Loop
- 119 Digital Loopback Test/V.54 Loop 2 (Local/Manual)
- 121 Digital Loopback Test/V.54 Loop 2 (Remote/Auto.)
- 122 Back-to-Back Test
- 124 Synchronous Mode Testing
- 124 Local Analog Loopback Test (Synchronous Mode)
- 125 Digital Loopback Test (Local/Manual) (Sync Mode)
- 126 Digital Loopback Test (Remote/Auto.) (Sync Mode)
- 128 Introduction
- 129 DIP-Switch Option Settings
- 137 Speaker Volume Control
- 138 Recording Option Configurations
- 140 Possible Causes and Solutions
- 148 Contacting Black Box
- 148 Recording Modem Information
- 149 Making the Call
- 149 Shipping and Packaging
- 150 Upgrading the Series II Modem’s Firmware
- 151 Appendix B - Dial Pulse and Tone-Dial Frequencies
- 152 Appendix C - Command Summary
- 165 Appendix D - DIP-Switch Summary
- 168 Appendix E - S-Register Summary
- 172 Appendix F - Result Code Summary
- 175 Appendix G - V.25bis Operation
- 188 Appendix H - Series II Modem Cables
- 190 Appendix I - RS232C Interface Specifications
- 196 Appendix J - Regulatory Information