AllSync Plus Clock Installation & Operation Guide


Add to my manuals
34 Pages

advertisement

AllSync Plus Clock Installation & Operation Guide | Manualzz

AllSync Plus Clock Specifications

AllSync Plus

®

Flush Metal Case

®

AllSync Plus Clock Installation

& Operation Manual

FEATURES

5 Year Warranty

• Microprocessor controlled movement

• 15 minutes of backup power (no batteries required)

• Accuracy to within ±1 second of a master clock

• Reduced power consumption

• Attractive modern design

• Heavy-duty construction

• All metal case

• Diagnostic LED

General Operation DESCRIPTION

The

american time

AllSync Plus clocks are provided in round or square metal cases with glass crystals and bold, black numerals and minute markers on a non-yellowing white dial. Stylish hour and minute hands are aluminum with a black finish and a red sweep second hand.

AllSync Plus clocks are designed to work with multiple master clocks and correction signals. This unit is programmed to identify the signal it receives from the master and operate as that style of clock. Changing clock operation from one style to another is as easy as unplugging the clock from one system and plugging it into another. If needed, changing the placement of 2 small jumpers on the circuit board can change the voltage required to run this clock from 120vac to 24vac or 24vac to 120vac. This clock provides 15 minutes of backup run power without the use of batteries. If a power outage should last longer than 15 minutes, the clock will synchronize to the master clock at the hourly and 12 hour correction cycles.

Correction Signals

Works on:

• Hourly correction: 7-9 seconds starting at the 57th minute and 54th second. 12 hour correction: 13-18 seconds starting at

5:57:54 (am and pm).

• Hourly correction: 24-28.5 seconds starting at the 0 minute and 0 second. 12 hour correction: 24-32 minutes starting at

6:00:00 (am and pm).

*Hourly correction: 54-56 seconds starting at the 58th minute and 5th second. 12 hour correction: 10 pulses of 94-96 seconds starting at 5:05:00 (am and pm) and repeating every 2 minutes.

• Hourly correction: 24-26 seconds starting at 0 minute and 0 second. 12 hour correction: 25 pulses of 24-26 seconds starting at 6:00:00 (am and pm) and repeating every 60 seconds.

• Hourly correction: 63-67 seconds starting at the 58th minute and 0 second. 12 hour correction: 14 pulses of 63-67 seconds starting at 5:06:00 (am and pm) and repeating every 2 minutes.

*Hourly correction: 54-56 seconds starting at the 58th minute and 5th second. 12 hour correction: 12 pulses of 63-67 seconds starting at 5:05:00 (am and pm) repeating every 90 seconds.

*Note:

When switching between these correction protocols, you must use a different correction protocol to complete the transition.

The AllSync Plus clock needs to distinguish between hourly corrections before it can change correction protocols internally.

20

140 3rd St. S, PO Box 707, Dassel, MN 55325

800-328-8996american-time.com

Page 1 of 2 PS03010 Rev H

© American Time

AllSync Plus Clock Installation

& Operation Manual

AllSync Plus Clock Specifications

SPECIFICATIONS

• 24vac/60 Hz or 120vac/60 Hz

• Current draw: 24vac, 1 watt, .043 amps

120vac, 3 watts, .028 amps

Maximum operating voltage: 24vac setting = 40vac

120vac setting = 150vac

Minimum operating voltage: 24vac setting = 15vac

120vac setting = 50vac

GENERAL

Types of secondary clocks compatible with AllSync Plus:

Cincinnati

Dukane

Edwards

Faraday

WS*, *D-8, *D-10, *D-12 Series

24SS* Series, 240* Series

Honeywell

Lathem

National Time

Simplex

®

& IBM

*010 & *012 Series

2315*, 2316*, 2335*, 2336*, 2380*, 2382*, 2310*, 2320*, 2330*, 2313*, 2314*, 2333*,

1310 through 1431 Series and 2420* through 2431* Series

ST402A* Series

Type SS* Series

*EX-HH and *EX-LL Series

77* Series, 82* Series, 2310 – 92* Series, 6310 – 92* Series

*Indicates more numbers before or after.

ORDERING INFORMATION

Part # Description

U45BHAA?04 10" Rd Flush, Black Sand 120vac

U45BHBA?04 10" Rd Flush, Black Sand 24vac

U55BHAA?04 12" Rd Flush, Black Sand 120vac

U55GHAA?04 12" Rd Flush, Steel Gray 120vac

U55BHBA?04 12" Rd Flush, Black Sand 24vac

U55GHBA?04 12" Rd Flush, Steel Gray 24vac

U58BHAA?04 12" Sq Flush, Black Sand 120vac

U58BHBA?04 12" Sq Flush, Black Sand 24vac

U65BHAA?04 15" Rd Flush, Black Sand 120vac

U65BHBA?04 15" Rd Flush, Black Sand 24vac

BEZEL FINISHES

Black Sand=BH

Matte finish

Steel Gray=GH

Smooth satin finish 12" round only

Note:

Replace the ? in the part number with the number from the list below that will correspond with the system you’re replacing.

New flush mount installations require backboxes.

0 = Faraday

7 = 2-hook

1 = National

8 = Setco

5 = Simplex

®

9 = R&H (keyhole)

6 = Cincinnati/Edwards

For a plexiglass crystal, replace the BH or GH in the part number with BG or GG.

Steel flush mount

A

B

Steel

OUTSIDE DIMENSIONS

Round

“A” Dimensions:

11

1

4

" for 10" clocks

13

1

4

" for 12" clocks

16" for 15" clocks

“B” Dimensions:

1

5

8

" for 10", 12" & 15" clocks

B

Flush mount steel square

A

B

Surface mount steel square

OUTSIDE DIMENSIONS

Square (12" only)

“A” Dimensions:

12

5

8

" for 12" clocks

A

“B” Dimensions:

1

1

4

" for 12" clocks

B

At American Time, we continually strive to improve our products to meet our customers’ needs and to provide the best possible value. The above specifications are believed to be correct, are subject to change without notice and may otherwise vary from the above. Please call if you need verification of any specifications or the suitability of a particular product for a particular application.

© American Time

Page 2 of 2 PS03010 Rev H

21