AllSync Plus Clock Specifications

AllSync Plus

®

Surface and Double Dial

Molded Case

®

AllSync Plus Clock Installation

& Operation Manual

FEATURES

5 Year Warranty

• UL Listed - 12" surface mount only

• Microprocessor controlled movement

• 15 minutes of backup power (no batteries required)

• Accuracy to within ±1 second of a master clock

• Reduced power consumption

• Attractive modern design

• Impact-resistant black plastic case

• Shatter-resistant polycarbonate crystal

• Diagnostic LED

General Operation

DESCRIPTION

The

american time

AllSync Plus clocks are provided in round only high impact black plastic cases with clear polycarbonate crystals and bold, black numerals and minute markers on a non-yellowing white dial. Stylish hour and minute hands are aluminum with a black finish and a red sweep hand. Other bezel colors available. Consult factory.

The

american time

AllSync Plus clock is designed to work with multiple master clocks and correction signals. This unit is programmed to identify the signal it receives from the master and operate as that style of clock. Changing clock operation from one style to another is as easy as unplugging the clock from one system and plugging it into another. If needed, changing the placement of 2 small jumpers on the circuit board can change the voltage required to run this clock from

120vac to 24vac or 24vac to 120vac. This clock provides 15 minutes of backup run power without the use of batteries. If a power outage should last longer than 15 minutes, the clock will synchronize to the master clock at the hourly and 12 hour correction cycles.

Correction Signals

Works on:

• Hourly correction: 7-9 seconds starting at the 57th minute and 54th second. 12 hour correction: 13-18 seconds starting at

5:57:54 (am and pm).

• Hourly correction: 24-28.5 seconds starting at the 0 minute and 0 second. 12 hour correction: 24-32 minutes starting at

6:00:00 (am and pm).

*Hourly correction: 54-56 seconds starting at the 58th minute and 5th second. 12 hour correction: 10 pulses of 94-96 seconds starting at 5:05:00 (am and pm) and repeating every 2 minutes.

• Hourly correction: 24-26 seconds starting at 0 minute and 0 second. 12 hour correction: 25 pulses of 24-26 seconds starting at 6:00:00 (am and pm) and repeating every 60 seconds.

• Hourly correction: 63-67 seconds starting at the 58th minute and 0 second. 12 hour correction: 14 pulses of 63-67 seconds starting at 5:06:00 (am and pm) and repeating every 2 minutes.

*Hourly correction: 54-56 seconds starting at the 58th minute and 5th second. 12 hour correction: 12 pulses of 63-67 seconds starting at 5:05:00 (am and pm) repeating every 90 seconds.

*Note:

When switching between these correction protocols, you must use a different correction protocol to complete the transition.

The AllSync Plus clock needs to distinguish between hourly corrections before it can change correction protocols internally.

30

140 3rd St. S, PO Box 707, Dassel, MN 55325

800-328-8996american-time.com

Page 1 of 2 PS03059 Rev D

© American Time

AllSync Plus Clock Installation

& Operation Manual

AllSync Plus Clock Specifications

SPECIFICATIONS

• 24vac/60 Hz or 120vac/60 Hz

• Current draw: Single dial:

24vac, 1 watt, .043 amps

120vac, 3 watts, .028 amps

Double dial:

24vac, 2 watts, .086 amps

120vac, 6 watts, .056 amps

Maximum operating voltage: 24vac setting = 40vac

120vac setting = 150vac

Minimum operating voltage: 24vac setting = 15vac

120vac setting = 50vac

GENERAL

Types of secondary clocks compatible with AllSync Plus:

Cincinnati

Dukane

Edwards

Faraday

Honeywell

Lathem

National Time

WS*, *D-8, *D-10, *D-12 Series

24SS* Series, 240* Series

*010 & *012 Series

2315*, 2316*, 2335*, 2336*, 2370*, 2372*, 2380*, 2382*, 2311*, 2320*, 2331*, 2314*,

1310 through 1431 Series and 2420* through 2431* Series

ST402A* Series

Type SS* Series

*EX-HH and *EX-LL Series

Simplex

®

& IBM 77* Series, 82* Series, 2310 – 92* Series, 6310 – 92* Series

*Indicates more numbers before or after.

ORDERING INFORMATION

Part # Description

U44BAAA904 10" Rd Surface 120vac

U44BABA904 10" Rd Surface 24vac

Part # Description

U64BAAA304 15" Rd Surface 120vac

U64BABA304 15" Rd Surface 24vac

U54BAAA304 12" Rd Surface 120vac

U54BABA304 12" Rd Surface 24vac

U53BAAA204 12" Rd Double dial wall 120vac

U53BABA204 12" Rd Double dial wall 24vac

U52BAAA204 12" Rd Double dial ceiling 120vac

U52BABA204 12" Rd Double dial ceiling 24vac

U63BAAA204 15" Rd Double dial wall 120vac

U63BABA204 15" Rd Double dial wall 24vac

U62BAAA204 15" Rd Double dial ceiling 120vac

U62BABA204 15" Rd Double dial ceiling 24vac

Note:

Double dial mounting requires a 4" square electrical box in the wall or ceiling.

Surface clocks have a molded in hanger double dial

Flush mount plastic

Surface mount plastic

OUTSIDE DIMENSIONS

Surface

SIZE A B C

10" 10

3

8

" 2

1

2

" N/A

12" 13

1

4

" 2

1

2

" N/A

15" 16" 2

1

2

" N/A

Double Dial (12" & 15" only)

12" 13

1

4

" 15" 8

5

8

"

15" 16" 19

1

/

4

" 8

5

8

"

Wall mount plastic double dial

B

Ceiling mount plastic double dial

A

Note: 12" surface mount clocks include security bracket.

Plastic double dial profile

A

A

A

B

A

B

B

B

A

C

At American Time, we continually strive to improve our products to meet our customers’ needs and to provide the best possible value. The above specifications are believed to be correct, are subject to change without notice and may otherwise vary from the above. Please call if you need verification of any specifications or the suitability of a particular product for a particular application.

Plastic double dial profile

© American Time

Page 2 of 2 PS03059 Rev D

31

C

Appendix B - LED Indication

AllSync Plus Clock Installation

& Operation Manual

Note: LED indicator can be found on the back of the AllSync Plus clock on the side of the dust cover as indicated by the decal, or refer to picture on page 19.

Normal Operation:

Flashing Green (0.5 sec. ON – 0.5 sec OFF) = Microprocessor is sending an update to the movement.

Note: The movement requests the time from the circuit board after startup and at 2am, 8am, 2pm and 8pm as seen on the clock. During this request the circuit board will send the time to the movement. Each request will last approximately 3 minutes.

Flashing Red (0.5 sec. ON – 0.5 sec OFF) = Incorrect DIP switch settings or clock error.

General Operation

Note: If the LED is flashing red settings in the clock may be incorrect. Contact American Time Technical support for assistance at

800-328-8996.

Alternating Red and Green (0.5 sec Red – 0.5 sec. Green) = AllSync Plus circuit board receiving correction signal from master.

Both colors OFF 1 sec. = At the top of each minute the AllSync Plus clock LED will turn off at the 00 sec. and continue with normal operation at 01 sec.

Note: After the clock has had sufficient time to synchronize (the LED will remain green and the movement has crossed 8:00 or 2:00 on its face) this LED flashing off should match the second hand on the clock passing the top of the minute.

Continuous Red = Power is on and the AllSync Plus circuit board has not received a 12 hour correction in last 15 hours.

Note: If the AllSync Plus clock is installed in a clock system running a correction protocol different than 01

(factory) or its previously recognized protocol, it may require more than one 12 hour correction to adjust its internal clock. In this case the LED will remain red after one 12 hour correction.

Continuous Green = Power is on and the AllSync Plus circuit board has received at least one 12 hour correction in the last 15 hours.

32

© American Time

AllSync Plus Clock Installation

& Operation Manual

Startup diagnostics routine

1. 5 sec. – solid red only

2. 1 sec. – OFF

3. 1 sec. – Green (DIP Switch 1 ON) or Red (DIP Switch 1 OFF)

Or

4. 1 sec. – OFF

5. 1 sec. – Green (DIP Switch 2 ON) or Red (DIP Switch 2 OFF)

Or

6. 1 sec. – OFF

Appendix B - LED Indication

7. 1 sec. – Green (DIP Switch 3 ON) or Red (DIP Switch 3 OFF)

Or

8. 1 sec. – OFF

9. 1 sec. – Green (DIP Switch 4 ON) or Red (DIP Switch 4 OFF)

Or

10. 2 sec. – OFF

11. Continue with normal operation

Note: For normal operation all DIP switches should be on or green during the startup diagnostics.

Note: If the circuit board has not received power for over 30 minutes it may cycle through the startup diagnostics several times while the power cell is charging.

© American Time

33

Glossary

AllSync Plus Clock Installation

& Operation Manual

General Operation

Clock Protocol - A specific time and duration of a set of correction pulses sent from a master clock to synchronize a clock system. Through the development of clock systems many different clock system manufacturers designed their own clock protocols. For this reason clocks cannot generally move from one system to another unless the system has the same clock protocol. The AllSync Plus clock is designed to recognize many different clock protocols.

Cold Start - AllSync Plus operational state in which power is applied for the first time or after the clock has not had power for a sufficient amount of time to drain it to the point it resets its internal processor.

LED - Light Emitting Diode - Indicator light on the back of the AllSync Plus clock.

Master Clock - In a clock system, a device that acts as the source of time. The master clock transmits the time to any number of secondary (or slave) clocks.

Movement - The inner mechanism of an analog clock that moves the clock’s hands.

Secondary Clock - Also known as a slave clock, this is a clock that synchronizes its timekeeping to that of a connected master clock.

Synchronization - The process of bringing two clocks or time sources into phase so their difference is zero. In the case of a timekeeping system, time synchronization takes place between the master clock and all secondary clocks.

34

© American Time