Through Flexible and Various Options,
To be Built up the Suitable Functions.
Electronic Trip Relay
Main setting module
1
WS1
WS2
WS3
General use
WM1
WM2
WM3
Generator protection use
WB1
WB2
WB3
Special use
1
2
3
LTD + STD + INST / MCR LTD + STD + INST / MCR INST / MCR only
Note : *For optimum protective coordination with upstream and/or downstream protective devices such as fuses and OCRs, WF relay (WF1/WF2/WF3) are provided.
As for the details about WF relay, please make inquiries.
Optional setting module
2
With optional setting modules, GFR, ER etc are added easily.
G1 E1 AP N5
Ground fault protection (GFR)
Earth leakage (ER)
(1)
2nd Additional Pre-alarm
Neutral pole
(2)
50% protection
Note (1) : combination with ZCT
(2) : With "N5" optional module, Neutral pole protection will be changed from 100% (standard) to 50%.
Power supply
3
It is neccessary for Display and
LEDs. (see page 19, 20.)
P1 100-240V AC•DC
P2 24-60V DC
P3 100-240V AC / 100-125V DC with output contact
P4
P5
24-60V DC with output contact
100-240V DC with output contact (SSR)
Additional function
EX1 Extension module DP1 Display TAL Temperature alarm
The TAL is operated by an unusual temperature of the breaker contacts.
Module for display and communication
Current,Voltage,Power,
Harmonics,Trip current,etc.
Note : The VT unit is required to display the measured data except the load current.
MCR-SW MCR switch
Making current release is possible with MCR switch.
■ Secure protection by actual effective value detection
For spread of electronic devices such as inverter, the actual effective value detection method is adopted, which is strong against deformed waveform and is detected from each phase independently .
Distorted current
Effective value conversion
Sin wave current
With interchangeable & add-on modules, flexible functions built up.
Network
Personal
Computer
MELSECNET/10
Interface card
PLC
By using various application software for PLC, users can also connect to the network
SCADA system.
MELSECNET/10
CC-Link ® / PROFIBUS-DP / MODBUS ®
Interface
Unit
I/O Unit
AE-SW
MDU
Eco Monitor Pro ME110NSR
Note : Some device types are excluded.
Interface unit
CC-Link
®
PROFIBUS-DP MODBUS
®
(RS-485)
BIF-CC BIF-PR BIF-MD
Communication items
Current, Voltage, Power, Harmonics, etc
Measurement / alarm Tripping cause/current
Alarm (PAL,TAL,Self diagnosis)
Breaker ON,OFF
Breaker control
Spring charge
ON/OFF
Breaker status
Drawout position
Note : The VT unit is required to display the measured data except the load current.
I/O unit
BIF-CON
ON, OFF, Spring charge, Digital input
Option to interface unit
I/O unit enables to turn ON/OFF the breaker and the spring charge via network.
And by addition of the drawout position switch, it is possible to transmit the breaker drawout position.
Display unit for Panel board
DP2
It has the same function as the breaker display unit.
In the case where the breaker is installed in the panel, it becomes possible to view the measurement information from the outside of the panel board.
Note : The VT unit is required to display the measured data except the load current.
VT unit
VT
VT unit enables to measure voltages, electric powers, harmonics and etc.
Electronic Trip Relay type code
●
Main setting module
WS1, WB1, WM1 AE630–1600-SW,
AE2000–3200-SW,
AE4000-SW
WS2, WB2, WM2 AE2000-SWA,
AE4000-SWA,
AE5000-SW
WS3,WB3,WM3 AE6300-SW
●
Optional setting module
G1: Ground fault protection
N5: Neutral pole 50% protection
E1: Earth leakage protection
AP: 2nd Additional Pre-alarm
NA: Without optional setting
●
Power supply
P1: AC
•
DC100-240V
P2: DC24-60V
P5: DC100-240V with output contact (SSR)
WS : General use
WM : Generator protection use
WB : INST/MCR only
P3: AC100-240V / DC100-125V with output contact
P4: DC24-60V with output contact
Additional function
Extension module(EX1)
Display(DP1)
Display onto panel board(DP2)
VT unit(VT)
Network
BIF-CC
BIF-PR
BIF-MD
Temperature alarm(TAL)
MCR switch(MCR-SW)
The safety of valuable circuits can be securely maintained.
Higher short circuit protection performance by improving breaking capacity
In case of 690V AC, Icu = Ics improved from 50 kA to 65 kA for AE630-SW~AE2000-SWA from 50 kA to 75 kA for AE2000-SW~AE4000-SWA from 50 kA to 85 kA for AE4000-SW~AE6300-SW
Wider choice coordination range by improving rated short-time withstand current
Icw (1s) improved from 65 kA to 75 kA for AE2000-SW~AE4000-SWA from 85 kA to 100 kA for AE4000-SW~AE6300-SW
(Former model) (New model)
(AE630-SW~AE2000-SWA)
(Former model) (New model)
(AE2000-SW~AE4000-SWA)
(Former model) (New model)
(AE4000-SW~AE6300-SW)
(Former model) (New model)
(AE2000-SW~AE4000-SWA)
(Former model) (New model)
(AE4000-SW~AE6300-SW)
AE630-SW
AE1000-SW
690V AC
AE1250-SW
AE1600-SW
600V AC
AE2000-SWA
~ 500V AC
AE2000-SW
AE2500-SW
AE3200-SW
AE4000-SWA
690V AC
600V AC
~ 500V AC
65
65
65
75
75
85
690V AC 85
AE4000-SW
AE5000-SW
AE6300-SW
600V AC 85
~ 500V AC 130
0 20 40 60 80 100 120 140
(kA)
Icu=Ics
Higher safety by improving insulation performance
Rated impulse withstand voltage (Uimp) for the main circuit is improved from 8 kV to 12 kV.
AE630-SW
AE1000-SW
AE1250-SW
AE1600-SW
AE2000-SWA
1s
2s
3s
AE2000-SW
AE2500-SW
AE3200-SW
AE4000-SWA
1s
2s
3s
AE4000-SW
AE5000-SW
AE6300-SW
1s
2s
3s
0
(Former model)
20 40
50
60
65
60
65
75
75
100
80
85
85
100
(kA)
Icw
(New model)
Higher reliability by High operating durability
■ Mechanical
The new models are sharply improved in mechanical durability compared to the former model.
Former model
New model
10000
AE630-SW AE1000-SW
AE1250-SW AE1600-SW
25000
25000
AE2000-SWA
AE2000-SW AE2500-SW
AE3200-SW
AE4000-SWA
AE4000-SW AE5000-SW
AE6300-SW
2000
0
5000
5000
10000
10000
(3-Pole)
10000 15000
20000
20000
20000 25000
(times)
■ Electrical
The new models (V2
✽
) are sharply improved in electrical durability compared to the former model.
✽ V2:High durability models
Former model
New model (V2)
5000
AE630-SW AE1000-SW
AE1250-SW AE1600-SW
AE2000-SWA
1500 (3200A: 1000)
AE2000-SW AE2500-SW
AE3200-SW
AE4000-SWA
500
5000
6000
0 2000 4000 6000
8000
8000
12000
10000 12000
(times/500V AC)
For convenience
3 sizes
Size1
AE630
-SW
AE1000
-SW
AE1250
-SW
AE1600
-SW
AE2000
-SWA
Size2
AE2000
-SW
AE2500
-SW
AE3200
-SW
AE4000
-SWA
Size3
AE4000
-SW
AE5000
-SW
AE6300
-SW
Compact size AE2000-SWA!
■
The compact AE2000-SWA can reduce the panel size.
Volume and weight
AE2000-SS
(Former)
AE2000-SWA
(New)
The former model (AE-SS) can be retrofitted.
■
It is same as the former model (AE-SS) in installation dimension and outline dimension, and the former model can be replaced with the new one.
■
ACB main body with drawout frame can be replaced.
■
It can be installed to the existing connection bus bar without any special connection kit.
(Except AE2000-SWA, AE4000-SWA)
Interchangeable
Bus bar
Zero arc space
Arc exhaust to the outside of the breaker is drastically reduced for safer operation.
(AE630-SW~AE4000-SWA models
≤ 600V AC)
(refer to page 54 : Insulation distance)
Former model New model
Reverse connection available
Line and Load is not defined on the Main circuit terminals.
Therefore, reverse connection is available without any limitation.
Fixed type
AE-SW Series
3
9
4
6
8
2
7
AE1600-SW 3P
1
5
1 Arc extinguishing chamber
2 Control circuit terminal block
3 Electronic trip relay
4 OFF button
5 ON button
6 Padlock hook
7 Charging indicator
8 ON/OFF indicator
9 Manual reset button(Optional)
In case of the fixed type,Lifting hooks (HP) are attached.
9
Drawout type
AE-SW Series
3
4
7
8
5
AE1600-SW 3P
2
6
1
1 Cradle
2 Control circuit terminal block
3 Lifting hole
4 Charging handle
5 Drawout position indicator
6 Extension rail
7 Position lock
8 Aperture for the drawout handle
9 Drawout handle
In case of the drawout type, Drawout handle is attached.
Skeleton
10
7
9
8
3 4 5 6
28
31
30
29
1 2
12 11
26 27
13
24 25
14
15
21
22 23
16
18
17
20
19
Product introduction
1 2
Type Standard
AE630-SW
AE1000-SW
AE1250-SW
AE1600-SW
AE2000-SWA
AE2000-SW
AE2500-SW
AE3200-SW
AE4000-SWA
AE4000-SW
AE5000-SW
AE6300-SW
6
Mechanical accessories
Push button cover
Counter
Cylinder lock
Terminal cover
Door frame
Dust cover
Interphase barrier
Mechanical interlock
Door interlock
IEC 60947-2
EN 60947-2(CE)
VDE
JIS C 8201-2-1
GB 14048.2(CCC)
(Shipping Approvals)
LR
GL
BV
DNV
ABS
CCS
NK
7
Electronic trip relay
General use
WS type
Generator protection use
WM type
Special use
WB type
Optional
G1:Ground fault protection
E1:Earth leakage protection
AP:2nd Additional Pre-alarm
N5:Neutral pole 50% protection
3
Connection
Drawout type
Horizontal terminal
Vertical terminal
Front terminal
Fixed type
8
Relay accessories
Extension module
Display
Temperature alarm
MCR switch
Neutral CT
External ZCT
VT unit
1 Air circuit breaker
2 Cradle
3 CC-Link ® Interface unit
4 PROFIBUS-DP Interface unit
5 MODBUS ® Interface unit
6 I/O unit
7 Extension module
8 ETR unit
9 Main setting module
10 Optional setting module
11 Door frame (DF)
12 Dust cover (DUC)
13 Push button cover (BC-L)
14 Auxiliary switch standard (AX)
15 Auxiliary switch high capacity type (HAX)
16 Shunt trip device (SHT)
17 Closing coil (CC)
18 Under voltage trip device (UVT)
19 UVT-controller (U-CON)
20 Condenser trip device (COT)
21 Motor charging device (MD)
22 Counter (CNT)
23 Cylinder lock (CYL)
24 Door interlock (DI)
25 Mechanical interlock (MI)
26 Safety shutters (SST)
27 Safety shutter lock ( SST-LOCK)
28 Cell switch (CL)
29 Interphase Barrier (BA)
30 Horizontal terminal
31 Vertical terminal
4
Drawout type accessories
Cell switch
Shorting b-contact
Lifting hooks
Safety shutter
Safety shutter lock
Mis-insertion preventor
Test jumper
9
Network
CC-Link ® Interface unit
PROFIBUS-DP Interface unit
MODBUS ® Interface unit
I/O unit
5
Electrical accessories
Auxiliary switch
Motor charging device
Closing coil
Shunt trip device
Under voltage trip device
Condenser trip device