advertisement
Yankee™
Pellet Stove
• Horizontal Or Vertical Vent
• Freestanding Stove
• Mobile Home Approved
• Class A Chimney Retrofit
• Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
Tested and Listed by
Omni-Test Laboratories, Inc.
Portland, Oregon
Report # 028-S-62-2
ASTM E1509-2004
- Please read this entire manual before installation and use of this pellet fuelburning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death.
- Contact local building or fire officials about restrictions and installation inspection requirements in your area.
- Save these instructions.
Installer: After installation give this manual to the home-owner and explain operation of this stove.
$10.00
Copyright 2008, T.I.
Part # 100-01156
4080728
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
2
Introduction
Introduction
We welcome you as a new owner of a Yankee pellet heater. In purchasing a Yankee you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Yankee is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this pellet-burning heater. Please familiarize yourself with the Owner's Manual before operating your heater and save the manual for future reference. Included are helpful hints and suggestions which will make the installation and operation of your new heater an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heater.
Important Information
No other Yankee heater has the same serial number as yours. The serial number is on the safety label on the back of the appliance.
This serial number will be needed in case you require service of any type.
Mail your Warranty Card
Today, and Save Your Bill of
S a l e .
Model: Yankee PS
Serial Number:
To receive full warranty coverage, you will need to show evidence of the date you purchased your heater. Do not mail your Bill of
Sale to us.
Purchase Date:
Purchased From:
We suggest that you attach your
Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Table of Contents
Introduction
Introduction ......................................................2
Important Information .........................................2
Safety Precautions
Safety Precautions ............................................4
Specifications
Heating Specifications ........................................6
Dimensions.......................................................6
Electrical Specifications......................................6
Fuel.................................................................6
EPA Compliance ................................................6
Installation
Before You Begin ...............................................7
Packing List......................................................7
Installation Options ............................................7
Planning The Installation .....................................7
Stove Placement ...............................................7
Floor Protection Requirements..............................7
Clearances - Straight Installation ..........................8
Clearances - Corner Installation ............................8
Venting the Pellet Stove ......................................9
Maximum Venting Distance .............................9
Pellet Vent Type............................................10
Installing the Pellet Vent .................................10
Pellet Vent Termination...................................10
Mobile Home Requirements ..................................11
Outside Air (used for combustion) .........................11
Alcove Installation Requirements ..........................12
Baffle Installation...............................................12
Door Seal Verification .........................................12
Restrictor Adjustment .........................................12
Thermostat Installation .......................................13
Installation Example: Direct "Through-the-wall"
Installation .......................................................14
Installation Example: Interior Vertical Installation ....15
Installation Example: Class A Chimney Retrofit ........16
Installation Example: Masonry Fireplace Hearth Stove.......................17
Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove..18
Installation Example: Freestanding Masonry Chimney................19
Operation
Safety Notice ....................................................20
Location of Controls ...........................................20
Starting the Heater for the First Time ......................20
Loading Pellets..................................................21
The Two Modes of Operation ................................21
Operation (continued)
Manual Mode.....................................................22
Auto Mode ........................................................23
Restrictor Adjustment .........................................24
Restrictor Adjustment .........................................24
Adjusting the Fan Speed......................................24
Start-Up Sequence.............................................25
"AUGER ON" Light..............................................25
"Maintenance Required" Light ...............................25
"MANUAL AUGER" Button....................................26
Power Outages..................................................26
Using a Pellet/Corn Mix with This Heater .................26
Maintenance
Daily Maintenance (whenever using the stove).........27
Inspect the Burn ...........................................27
Make Sure Pellets are Not Piling Up...................27
Check Firepot for Clinkers ...............................28
Cleaning the Firepot .......................................28
Door Opening ...............................................29
Weekly Maintenance (or every 5 bags of pellets) ......30
Flyash Removal ............................................30
Clean the Hopper...........................................30
Clean the Heat Exchange Tubes.......................30
Clean the Baffles...........................................31
Sweep Ash Into Ashpan..................................32
Check Ashpan, Dispose if necessary ................33
Clean the Glass ............................................33
Yearly Maintenance (or every ton) .........................34
Clean the Vertical Exhaust Duct .......................34
Clean the Exhaust Blower ...............................35
Clean the Vent ..............................................35
Door Seal.....................................................36
Normal Operating Sounds
Normal Operating Sounds ....................................39
Safety Label
Safety Label .....................................................40
Warranty
Warranty ..........................................................41
Index
Index...............................................................42
3
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
4
Gas
Safety Precautions
• Do not operate the
heater if you smell smoke coming from the heater. Turn the
M
ODE switch to
"OFF", monitor your heater, and call your d e a l e r .
• Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or 'freshen up' a fire in this heater. Keep all such liquids well away from the heater while it is in use.
Ok
Sealant
• Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this heater as well.
• The exhaust system must be completely airtight and properly installed. The pellet vent joints must be sealed with RTV 500 o
F.
(260 o
C.) silicone sealant.
• Do not unplug the heater if you suspect a malfunction. Turn the
M
ODE
S
WITCH to "OFF" and periodically inspect the heater.
• Never try to repair or replace any part of the heater unless instructions are given in this manual.
All other work should be done by a trained technician.
• This unit must be properly installed to prevent the possibility of a house fire.
The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.
• Your heater requires periodic maintenance and cleaning (see "Maintaining
Your Heater"). Failure to maintain your heater may lead to smoke spillage in your home.
• The viewing door and ashpan must be closed and latched during operation.
• Never block free airflow through the open vents of the unit.
• Do not operate the heater if the flame becomes dark
& sooty of if the firepot overfills with pellets. Turn the M
ODE
S
WITCH
to
"OFF" and periodically inspect the heater (see
"Running Your Heater").
© Travis Industries
4080728
A
A
A
A
• Allow the heater to cool before carrying out any maintenance or cleaning.
Ashes must be disposed
A
A in a metal container with a tight lid and placed on a non-combustible surface well away from the home or structure.
A
A
AA
AA
A
A
AA
• This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn,
50% pellets. See page 25 for details on using a corn pellet mix.
1 0 0 - 0 1 1 5 6
?
This
Manual
Safety Precautions
• The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room.
• Keep foreign objects out of the hopper.
Mobile
Home
• This heater must be connected to a standard
115 V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug.
Do not route the electrical cord underneath, in front of, or over the heater.
• When installed in a mobile home, the heater must be bolted to the floor, have outside air, and NOT BE
INSTALLED IN THE
BEDROOM (Per H.U.D.
requirements). Check with local building officials.
• The exhaust system should be checked twice a year minimum for any build-up of soot or creosote.
• Disconnect the power cord before performing any maintenance.
N O T E :
Turning the Mode Switch to "OFF" does not disconnect all power to the heater.
• Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.
• Do not place clothing or other flammable items on or near the heater.
Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.
• Do not touch the hot surfaces of the heater.
Educate all children of the danger of a hightemperature heater.
Young children should be supervised when they are in the same room as the heater.
• Travis Industries, Inc.
grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s).
5
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
6
Specifications
Heating Specifications
Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250 Sq. Feet
Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5
Maximum Burn Time on Low Burn** ......................................................................47 Hours
Hopper Capacity ..............................................................................................80 Pounds
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel quality may occur.
Dimensions
This tab can be bent out and used to hang the scraper rod tool.
5-1/4"
13"
4"
Diameter
Exhaust
32"
Air Inlet
(1-3/4"
Outside
Diameter)
AA
9-1/4"
16-1/2"
25"
23"
Weight: 225 Lbs.
Electrical Specifications
Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence ...................................................................400 (approximately)
Fuel
Watts During Operation ...............................................................................180 (approximately)
• This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets.
See page 25 for details on using a corn pellet mix.
EPA Compliance
This heater has been tested exempt from EPA Phase II Requirements by OMNI-Test Laboratories, Inc.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
Before You Begin
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER.
FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
Check with local building officials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation.
Packing List
• Thermostat & Wire • Scraper Rod Tool • Brush • Spare Fuses
Installation Options
•
•
•
•
•
Residential or Mobile Home (see the section "Mobile Home Requirements")
Alcove Compatible (see the section "Alcove Installation")
Horizontal or Vertical Vent
Outside Air Compatible
Vent with L-Vent, L-Vent Fireplace Liner, or Type A Chimney (with adapter)
Planning The Installation
HINT:
HINT:
HINT:
HINT:
Have an authorized Travis Industries dealer install this heater. If you install the heater yourself, have your dealer review your installation plans.
Sketch out a detailed plan of the installation including dimensions. Then verify the dimensions with the requirements listed in this manual.
When determining the location of the stove, locate the wall studs (for horizontal penetrations) and ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member.
Place the heater outside and load 10 pounds of pellets inside the hopper. Plug the heater in and let it run on HIGH until the pellets run out. This will cure the paint and burn off any oil on the steel, eliminating any smell inside the home.
Stove Placement
•
•
•
HINT:
Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the heater.
If the stove is placed in a location where the ceiling height is less than 7', it must follow the requirements in the section "Alcove Installation Requirements".
REDUCING CLEARANCES - Clearances may be reduced by methods specified in NFPA
211, listed wall shields, pipe shields, or other means approved by local building or fire officials.
Heater and floor protection must be installed on a level, secure floor.
Floor Protection Requirements
•
• The heater must be installed on a non-combustible floor protector extending the full width and depth of the heater and extending 6" in front (minimum 25" wide by 29" deep)
(minimum .018" thick - 26 gauge) .
Must extend under and 2" to each side and rear of a "Tee" (if used).
7
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
8
Installation
(For Qualified Installers Only)
Clearances - Straight Installation
Through the Wall Installations Interior Vertical Vents
A
A
A
A
3” Minimum
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
9” Minimum
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
Floor Protection
AAAAAAAA
AAAAAAAA
Vent
Clearance*
AAAAAAAA
AAAAAAAA
“Tee”
2”
AAAAAAAA
AAAAAAAA
Minimum**
AAAAAAAA
AAAAAAAA
9” Minimum
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
Through the Wall Vents Interior Vertical Vents
45°
A
A
AA
AA
AAAAAAAAAAAA
AAAAAAAAAAAA
45° Elbow
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
3” Minimum
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
*
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
NOTE: If interior vertical vent is used, the stove to backwall dimension is determined by the vent being used. This dimension will vary depending on the brand of pellet vent used. To determine the distance from the backwall to the stove, connect the "Tee" and add the vent clearance .
** The floor protection must extend 2” or to the wall (whichever is less) – all vent clearances must be met.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
Venting the Pellet Stove
•
•
•
•
•
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
M A N U F A C T U R E R .
DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY
OTHER APPLIANCE OR STOVE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM
OF THIS UNIT.
USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT
THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER
WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO
MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).
No more than one tee and 180
°
of elbows (one tee with two 90
°
elbows, one tee with one
90
°
and two 45
°
elbows, etc.).
9
33 Feet
(max.)
Maximum Venting
Distance
30 Feet
• Vent must have a support bracket every 5' of pellet vent when exterior of structure
The vent height and run must not exceed the distance shown in the shaded region shown to the right.
25 Feet
20 Feet
Venting into this shaded area may require restrictor adjustments. See the section “Restrictor
Adjustment” for details.
15 Feet
10 Feet
NOTE: To achieve optimum performance, we recommend keeping the vent as short as possible
(horizontal run especially).
5 Feet
© Travis Industries
4080728
10 Feet (max.)
0 Feet
1 0 0 - 0 1 1 5 6
1 0
Installation
(For Qualified Installers Only)
Pellet Vent Type
• Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc…) must be sealed with 500
°
F. RTV silicone.
Installing the Pellet Vent
500
° F. RTV
Silicone
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500°
F. RTV silicone into the gap between sections.
•
• Horizontal sections must have a 1/4" rise every 12" of travel.
Pellet vent connections must be sealed airtight with 500
°
F. RTV silicone and screwed together with at least three sheet metal screws.
Pellet Vent Termination
• Vent must terminate on the exterior of the dwelling. Horizontal terminations must protrude a minimum12" from the wall. Vertical terminations must protrude a minimum 24" from the roof surface. In addition, all clearances listed below must be met.
• Must have an approved cap (to prevent water from entering) or a 45
°
downturn with rodent screen.
• If the termination is located on a windy side of the house, an approved house shield is recommended to prevent soot from building up on the side of the house.
• Must not be located where it will become plugged by snow or other material.
H
X
G
A
F
B
D
C
H F
A
E
NOTE: Measure clearances to the nearest edge of the exhaust hood.
A
B
C
D
E
F
G
H
X
Minimum 4' clearance below or beside any door or window that opens
(This clearance may be reduced to18” if using outside air (see page 11) – we recommend the door or window be kept closed during operation.
Minimum 1’ clearance below or beside any window that does not open.
Minimum 1' clearance above any door or window that opens
Minimum 2' clearance from any adjacent building
Minimum 7' clearance above any grade when adjacent to public walkways
NOTE: Vent may not terminate in covered walkway or breezeway.
Minimum 2' clearance above any grass, plants, or other combustible materials
Minimum 3' clearance from any forced air intake of any other appliance
Minimum 2' clearance below eaves or overhangs
Minimum 1' clearance horizontally from combustible wall
Must be a minimum of 2' above the roof
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
Mobile Home Requirements
•
•
•
Outside air is required (used for combustion) - see the directions below.
The heater must be bolted to the floor (Some states do not require this; check with your local building department). See the illustration to the right.
The heater must be grounded to the steel chassis of the mobile home (Some states do not require this; check with your local building department).
WARNING: DO NOT INSTALL IN
SLEEPING ROOM.
CAUTION: THE STRUCTURAL
INTEGRITY OF THE
MANUFACTURED HOME
FLOOR, WALL, AND
CEILING/ROOF MUST BE
MAINTAINED.
b
Use the lag bolts (used to secure the stove to the pallet) to screw the pedestal to the floor.
7/16”
Socket
a
Remove the ash pan
(see page 29).
Outside Air (used for combustion)
• Must not be drawn from an enclosed space (garage, unventilated crawl space).
HINT: Travis Industries strongly suggests outside air for all residential installations, especially for those that are energy efficient, air-tight homes.
• Must not be over 15' long.
• Must be made with 1 3/4" diameter or larger metal or aluminum duct with a metal screen attached to the end to keep out rodents
(P.V.C. or other combustible materials may not be used). We recommend the Travis
Industries Outside Air Kit
(part # 99200136).
• Must not terminate above or within 1' of the chimney termination.
• Must have a rain cap or down-turned elbow to prevent water from entering.
• Must be located so that it will not become plugged by snow or other material.
A
13"
NOTE:
This valve must be open (the rod parallel with the tube) when the stove is in operation.
Seal the area around the tube to prevent air from entering through the wall.
Select a location between framing members for the outside air hole.
9-1/4"
AA
AA AA
AA AA
AA
AA
AAAAA
AA
A
A
AAA
AAAAA
Cut a minimum 2" diameter
AAA
AAA
AAA
AA
AA
AA hole in the wall.
1-3/4" Diameter Flex Duct
AAAAAAAAAA
AAAAAAAAAA
Silicone
AAAAAAAAAA
Silicone
AA
AAAAAAAAAA
AAAAAAAAAA
AAAAAAAAAA
AAAAAAAAAA
AAAAAAAAAA
AA
AA
AAAAAAAAAA
AAAAAAAAAA
Rain Hood with Rodent Screen
AA
AAAAAAAAAA
AAAAAAAAAA
AAAAAAAAAA
1 1
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
1 2
Installation
(For Qualified Installers Only)
Alcove Installation Requirements
When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met.
•
Minimum height is 60"
•
Maximum depth is 48"
•
Minimum width is 43"
•
Minimum clearance of 9" on each side and 3" on back
Baffle Installation
Install the baffles included with the stove (see page 29 for details).
Door Seal Verification
The door is aligned prior to leaving the factory. However, shipping and installation may cause the door to become mis-aligned. Verify the door is correctly aligned and seals properly (see the section "Door Seal" under Yearly Maintenance).
Restrictor Adjustment
The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting and burn the pellets at the appropriate rate. This keeps the firepot as clean as possible.
For low heat output settings the restrictor will need to be closed or near closed to limit the amount of air.
This prevents the stove from burning the pellet fuel faster than it is fed.
For medium heat output settings the restrictor will need to be opened to a medium position.
For high heat output settings the restrictor will need to be opened to a high position. This prevents the firepot from over-filling with pellets and becoming clogged with ash clumps.
Keeping your firepot clean is the most important step to maintaining a safe and efficient stove. Check and clean your firepot daily until you find the correct restrictor settings and appropriate firepot cleaning interval.
Not Enough Air
If clinkers (ashes that solidify into a clump) develop or the flame appears lazy and slow to blow the ash out of the firepot, pull the restrictor outward until the flame becomes active and the firepot holes remain clean.
NOTE: If the restrictor is fully out, yet the firepot does not remain clean, the stove needs to be cleaned and checked for air leaks (see “Maintenance” section of this manual).
Too Much Air
If the flames are too active (small, flickering flames) or if burning pellets are expelled from the firepot, move the restrictor rod inwards until the flame slows down and no burning pellets are expelled (note: it is okay to have “glowing embers” jump out of the firepot). Another symptom of too much air is the heater “blowing the fire out” – a condition in which the pellets burn faster than they are fed (this is most common on low).
© Travis Industries
4080728
A A
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
1 3
Thermostat Installation
!
Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater).
A thermostat is included with this heater (part # 99300650). Follow the directions below to install.
1 Attach the thermostat wire to the circuit board
(see the illustration below). Route the wire through the back of the heater (away from any hot or moving components).
50 60 70 80 90
Pull the cover off the thermostat
50 60 70 80 90
Run the thermostat wires through the wall (cut off excess wire, leaving 6” of slack).
Robertshaw
Attach the quick-connects to the two posts near the molex connector on the circuit board (orientation does not mater).
2 Determine a location for the thermostat that is within range of the 20' length of thermostat wire.
It should be centralized in the room and away from the heater. The wire may be routed externally on the wall or behind the wall
(preferred).
3 Follow the directions to the right to attach the thermostat and thermostat wires.
Expose 1/2” of wire and attach to these two posts.
Standard
Screwdriver
Attach the thermostat to the wall through these two holes.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
1 4
Installation
(For Qualified Installers Only)
Installation Example: Direct "Through-the-wall" Installation
Horizontal Rain Cap
Type "L"
Vent
Outside Air
12” Minimum
House Shield (used to protect exterior wall from soot
AAAAAAAAAAAAA
Wall Thimble (note
AA
AA clearance between vent and combustibles)
A
A
A discoloration) is HIGHLY RECOMMENDED
AAAAAAAAAAAAA
AAAAAAA AA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
9” Minimum
AAAAAAA
AAAAAAA
AA
AA
AA
AA
AA
AA
Floor Protection
500
° F. RTV
Silicone
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of
500° F. RTV silicone into the gap between sections.
12”
Minimum
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
3” Minimum
16-1/2”
9-1/4”
Floor Protection
AAAAAAAAA
AAAAAAAAAAAAA
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
Installation Example: Interior Vertical Installation
AAAAAAAAAAAAAAA
Vent
Type "L" Vent
Floor Protection
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
2”
Outside
Air
(optional)
AA
AA
AA
AA
AA
AA
AA
AA
AA
Vertical Cap
24” Minimum
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAA
AAAA maintain
A
A
A
A
AAAAAAA
AAAAAAAA
AAAAAAAA
Ceiling Support / Fire Stop Spacer
AA
AA
AA
Insulation clearance.
AA
AA A
A
A
A
A
A
A
A
° F. RTV
500
Silicone
A
A
Floor Protection
A
AAAAAAAAAAAAA
Outside air may be drawn from a ventilated crawl space.
* Install vent at clearance specified by the vent manufacturer.
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of
500° F. RTV silicone into the gap between sections.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
1 5
1 6
Installation
(For Qualified Installers Only)
Installation Example: Class A Chimney Retrofit
AAAAAAAAAAAAAA
AAAAAAAAA
2”
Minimum
A
A
Vent
Clearance*
AAAAAAAAA
AAAAAAAAA
Type "L" Vent
Floor Protection
“Tee”
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
Outside
Air
(optional)
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA
AAAAAA
AAAAAA
A
A
A
A
A
A
A
A
500
° F. RTV
Silicone
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of
Storm Collar
AA
AA
AA
A
A
A
A
A
A
A
AAAA
AAAA
AAAA
Class A Chimney
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAA
AAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAA
AAAAAA
A
A
Vent
Clearance*
A
A
AAAAAA
AAAAAA
“L” Vent to Class A Chimney Adapter
AAA
AAA
AAA
“L” Vent
500° F. RTV silicone into the gap between sections.
A
A
Floor Protection
A
A
Outside air may be drawn from a ventilated crawl space.
* Install vent at clearance specified by the vent manufacturer.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
Installation Example: Masonry Fireplace Hearth Stove
Vertical Cap
“L” Vent
Cover Plate (non-combustible)
AAAA
AAAA
AAAA
AAAA
Outside air may be drawn from the ash cleanout.
Storm Collar
AAAAA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
Silicone
AAAA
AAA
AAA
AAA
AAA
AAA
AAAA
AAAA
AA
AA
AA
AA
AAA
AAAA
AAAAA
AAAAA
AAAAA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
3”
Seal the cover plate with silicone.
AAAA
AAAA
AAAA
AAAA
Section
AA
AA
AA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AA
AA
AA
AA
AA
AA
500
° F. RTV
Silicone
6” Min.
AAA
AAA
NOTE: you will probably need a short horizontal section here to clear the lintel and allow the hopper lid to open.
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of
500° F. RTV silicone into the gap between sections.
AA
1 7
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
1 8
Installation
(For Qualified Installers Only)
Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove
Vertical Cap
Storm Collar
Cover Plate (non-combustible)
Silicone
Seal the cover plate with silicone.
“L” Vent
AAAA
AAAA
AAAA
AAAA
“L” Vent Flex
Section
AAAA
AAAA
AAAA
AAAAA
AAAAA
AAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
3”
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AA
AA
AA
AA
AA
AA
AA
AA
AAAA
AAAA
AA
AA
AA
AA
AAAA
AAAA
AAAA
AAAA
° F. RTV
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of
500° F. RTV silicone into the gap between sections.
6” Min.
AA
AA
AAA
AAA
NOTE: you will probably need a short horizontal section here to clear the lintel and allow the hopper lid to open.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation
(For Qualified Installers Only)
Installation Example: Freestanding Masonry Chimney
Vertical Cap
“L” Vent
Cover Plate (non-combustible)
AAAA
AAAA
AAAA
AAAA
“L” Vent Flex
Section
Clean-Out Access
Storm Collar
AAAA
AAAA
AAA
AA
AA
AA
AAA
AA
AA
AAA
AA
AAA
AAA
AA
AA
AA
AA
AAA
AA
AA
AA
AA
AA
AAA
AAA
AAA
AAA
AA
AAA
AA
AA
AA
AA
AA
AAA
AA
AA
AAA
AAA
AAAA
AAAA
AA
AA
AAAAA
AAA
AAA
AAA
AAAAA
AAA
AA
AA
AAA
AAAAA
AA
AAAAA
AA
AA
AAA
AAA
AAA
AAA
AAA
AAA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AAA
AAAAA
AA
AA
AA
AA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
Seal the cover plate with silicone.
AAAAA
AAAAA
AAAAA
AAAAA
AAA
AAA
AAA
“L” Vent
Sections
Vent
Clearance*
500
° F. RTV
Silicone
Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of
500° F. RTV silicone into the gap between sections.
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
6” Min.
AAAAAAAAAAAAAAAA
* Install vent at clearance specified by the vent manufacturer.
1 9
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
2 0
Operation
Safety Notice
!
!
Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death.
Do not unplug the stove to turn it off. This stove relies upon electricity to push the flue gases out the pellet vent – unplugging it may lead to smoke entering your room.
Failure to maintain your heater will lead to a restricted combustion air system, leading to poor performance and in some cases, smoke spillage into the room. See the
"Maintenance" section for details.
Location of Controls
Control Panel
Restrictor
The restrictor adjusts the amount of air flowing to the flame.
Thermostat or Remote
(required for Auto
Operation)
°F
°F
SET TEMPTIMER
MIN
Time Set
Time
Cancel
A
Firepot
Starting the Heater for the First Time
The stove paint is cured through heat. To prevent it from bonding to the door gasket, you must burn the heater for approximately 1 hour, then open and close the door to break any bonding.
Curing the Paint
2 to 4 hours
This stove uses a heat-activated paint that will emit some fumes while starting the first fire.
Open doors and windows to the room to vent these fumes. You may also notice oil burning off of the interior of the stove. This ruststopping agent will soon dissipate.
Priming the Auger
AA
A
A
Because of its electronic control panel, this stove does not require priming. If you run out of pellets you may notice it will take approximately 5 minutes longer for the stove to start.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Operation
Loading Pellets
Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 80 pounds of pellets.
To Open the Hopper Lid:
lift the hopper lid from this handle.
To Close the Hopper Lid:
lift the lid, pull this bar forward, then lower the lid down.
These notches allow you to open the hopper lid to the level you wish.
Pe l l e t s
Make sure pellets are not left on this heat shield.
AAAA
A
AAAAAAA
AAAAA
AAAAA
2 1
Warning:
The front edge of the hopper lid becomes very hot, do not touch the area below the handle.
The Two Modes of Operation
M a n u a l
Manual mode requires the user to turn the heater on and off manually.
Auto (requires a thermostat)
Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected.
Switching Modes While in
Operation
Whenever the stove is switched from one mode to another while in operation, the stove will enter the "startup" sequence for a minimum of 20 minutes.
© Travis Industries
H
E
A
T
P
U
T
O
U
T
H
E
A
T
DISCONNECT POWER BEFORE SERVICE
HIGH
MED
LOW
AUTO
MANUAL
MAINT.
(REQUIRED)
UP
AUTO
OFF
MANUAL
DOWN
AUGER
MANUAL
F
A
N
UP START
MANUAL
DOWN
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
These indicator lights are used to determine which mode you are in.
Use the mode switch to determine the mode.
4080728
1 0 0 - 0 1 1 5 6
2 2
Operation
Manual Mode
Manual mode requires the user to turn the heater on and off manually.
To Start
Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes. During this period the lowest “HEAT OUTPUT” light will flash. If the stove does not start in 30 minutes, the stove turns off.
Once up to temperature, the stove will then run at the heat output setting selected on the control panel (see “To Adjust the Heat” below).
F
A
N
H
E
A
T
UP
AUTO
OFF
MANUAL
DOWN
MANUAL
UP
DOWN
START
MANUAL
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
To Shut Down
Move the mode switch to "OFF". The exhaust blower will still run until the heater cools down.
To Adjust the Heat
Press the "Heat” buttons to adjust the heat output.
NOTE: During start-up you may adjust the heat setting. This heat setting will take affect once the start-up sequence is complete.
F
A
N
H
E
A
T
UP
AUTO
OFF
MANUAL
DOWN
MANUAL
UP
DOWN
START
MANUAL
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
H
E
A
T
T
P
O
U
U
T
H
E
A
T
DISCONNECT POWER BEFORE SERVICE
HIGH
MED
LOW
AUTO
MANUAL
UP
AUTO
OFF
MANUAL
DOWN
AUGER
MAINT.
(REQUIRED)
MANUAL
F
A
N
UP START
MANUAL
DOWN
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
© Travis Industries
4080728
These lights indicate the heat output setting.
NOTE: the lights may be difficult to see from an angle.
Press the
“up” or
“down” button to adjust the heat output.
1 0 0 - 0 1 1 5 6
Operation
Auto Mode
Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected.
To Adjust Room Temperature (or Start the Stove)
Move the thermostat to the heat setting desired. If the room is cooler than the setting, the stove will go through the start-up sequence for approximately 10 minutes. During this period the lowest “HEAT OUTPUT” light will flash. Once up to temperature, the stove will then run at the heat output setting selected on the control panel. If the room is too hot, move the thermostat to a lesser setting.
2 3
To Adjust the Heat
Press the "Heat” buttons to adjust the heat output.
HINT:
If you find that the stove turns on and off repeatedly, you may wish to turn the heat output to a lesser setting. The lower setting will provide a more consistent heat output over time, eliminating the need for the thermostat to repeatedly turn the stove off.
NOTE:
If the thermostat calls for heat while the stove is still cooling down, the stove will go through the start-up sequence (for a minimum of 20 minutes).
To Shut Down
Move the mode switch to "OFF". The exhaust blower will still run until the heater cools down.
© Travis Industries
4080728
H
E
A
T
P
U
T
O
U
T
H
E
A
T
DISCONNECT POWER BEFORE SERVICE
HIGH
MED
LOW
AUTO
MANUAL
UP
AUTO
OFF
MANUAL
DOWN
AUGER
MAINT.
(REQUIRED)
MANUAL
F
A
N
UP
DOWN
START
MANUAL
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
These lights indicate the heat output setting.
NOTE: the lights may be difficult to see from an angle.
Press the
“up” or
“down” button to adjust the heat output.
H
E
A
T
F
A
N
UP
AUTO
OFF
MANUAL
DOWN
MANUAL
UP
DOWN
START
MANUAL
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
1 0 0 - 0 1 1 5 6
2 4
Operation
Restrictor Adjustment
The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting and burn the pellets at the appropriate rate. This keeps the firepot as clean as possible.
For low heat output settings the restrictor will need to be closed or near closed to limit the amount of air.
This prevents the stove from burning the pellet fuel faster than it is fed.
For medium heat output settings the restrictor will need to be opened to a medium position.
For high heat output settings the restrictor will need to be opened to a high position. This prevents the firepot from over-filling with pellets and becoming clogged with ash clumps.
Keeping your firepot clean is the most important step to maintaining a safe and efficient stove. Check and clean your firepot daily until you find the correct restrictor settings and appropriate firepot cleaning interval.
Not Enough Air
If clinkers (ashes that solidify into a clump) develop or the flame appears lazy and slow to blow the ash out of the firepot, pull the restrictor outward until the flame becomes active and the firepot holes remain clean.
NOTE: If the restrictor is fully out, yet the firepot does not remain clean, the stove needs to be cleaned and checked for air leaks (see
“Maintenance” section of this manual).
Too Much Air
If the flames are too active (small, flickering flames) or if burning pellets are expelled from the firepot, move the restrictor rod inwards until the flame slows down and no burning pellets are expelled (note: it is okay to have “glowing embers” jump out of the firepot). Another symptom of too much air is the heater “blowing the fire out” – a condition in which the pellets burn faster than they are fed (this is most common on low).
Adjusting the Fan Speed
H
E
A
T
UP
AUTO
OFF
MANUAL
DOWN
MANUAL
F
A
N
UP START
MANUAL
DOWN
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
A
A
A
Press the “up” or “down” button to adjust the fan speed.
NOTE: When adjusting the fan speed the HEAT
OUTPUT lights will flash the fan speed setting for one second.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Operation
Start-Up Sequence
This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.). This sequence over-rides all user settings (except the
"OFF" position) to set the auger feed rate to medium, the exhaust blower to high, and the igniter on.
During this period the lowest “HEAT OUTPUT” light will flash.
"AUGER ON" Light
This light comes on when the auger is turning. This allows the operator to determine when the auger is turning.
"Maintenance Required" Light
The “MAINTENACE REQUIRED” light is used to indicate maintenance is required on the heater. It will turn on due to various operating circumstances.
When it turns on, a second light will turn on near
“HEAT OUTPUT” (see the illustration to the right).
Determine the maintenance code (2, 4, or 6), then use the chart below to diagnose and remedy the situation.
Light
2
(green)
4
(yellow)
Likely Cause
•
Heavy Ash Build-Up in Exhaust Duct
•
Heavy Ash Build-Up in Exhaust
Housing or Plugged Tubing
•
Heavy Ash Build-Up in Vent
•
Heater Ran Out of Pellets
•
Heater Did Not Start-Up Correctly
6
(red)
•
Power Outage
•
Restrictor Not Set Properly
•
Burnpot Clogged
•
Air Leak
•
Heavy Ash Build-Up
•
Electrical Input Error (voltage or mhz fluctuation, amp deficiency, etc.)
•
Components Over-Heated
•
Faulty Wiring / System Fault
O
U
T
P
U
T
H
E
A
T
DISCONNECT POWER BEFORE SERVICE
HIGH
AUTO
MANUAL
MED
LOW
AUGER
MAINT.
(REQUIRED)
# 6 Light
(red)
# 4 Light
(yellow)
# 2 Light
(green)
R e m e d y
•
Clean the Firebox (see page 34)
•
Clean the Exhaust Housing and Tubing (see page
35)
•
Clean the Vent (see page 35)
•
Refill the Hopper (see page 21)
•
Re-Start the Heater and Verify the Pellets Ignite after 10 Minutes
•
Re-Start the Heater (see page 26)
•
Re-Start the Heater and Monitor Restrictor
Setting (see page 24)
•
Clean Burnpot (see page 28)
•
Verify Door, Glass, and Ashpan Seal Correctly
(see page 37)
•
Clean the Firebox (see page 34), Exhaust
Housing (see page 35), and Vent (see page 35)
•
Unplug the Heater then Plug it Back In (this restarts the circuit board)
•
Clean the Heater and Vent (a plugged heater will slow exhaust flow, increasing temperatures – see pages 34- 35)
•
If this Fault Persists, Contact Your Dealer
2 5
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
2 6
Operation
"MANUAL AUGER" Button
This button turns the auger on. It is used to “prime” the auger after the hopper has run out of pellets.
Power Outages
!
If a sustained power outage occurs while in "Manual", the stove will go to a "cool down" mode to vacate smoke once power returns. If the power outage was short, the heater will go to the start-up sequence. If in "Auto", the stove will re-start (if the room is cool).
Because this stove relies upon a blower to evacuate the smoke, some smoke may enter the home during a power outage. To keep to a minimum, leave the door closed.
Using a Pellet/Corn Mix with This Heater
This heater may burn a mixture of corn and wood pellets up to a 50% - 50% proportion by volume.
Shelled corn burned in Travis pellet appliances must be clean (free of husk and cob residue) and have a moisture content no greater than 15%.
DO NOT BURN A MIX WITH MORE THAN 50% CORN TO WOOD PELLETS.
THOROUGHLY MIX THE TWO FUELS TOGETHER TO BE SURE OF AN
EVEN BURN RATE.
•
•
If combustion is slow, if the fire is slow to start, or if clinkers (ashes that solidify into a clump) build up rapidly in the fire pot, decrease the proportion of corn and increase the proportion of wood pellets until you find a proportion that works well in your appliance.
If your stove or insert is operated with a thermostat, you may notice the automatic igniter at times fails to light a 50/50 corn to pellet mix. If you experience this, decrease the proportion of corn and increase the proportion of wood pellets in the mix.
For an optimum fire and greatest efficiency, it is important to keep the fire pot free of built up ashes. If you are burning only high quality wood pellets, you should check and clean the fire pot at least every two weeks or after ten bags of pellets.
If the pellets you are burning have a high ash content or if you burn a corn/wood pellet mixture, we recommend that you check the fire pot every day and clean it if necessary.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Maintenance
Daily Maintenance (whenever using the stove)
Inspect the Burn
When burning on high, the flames should be bright orange with embers jumping from the firepot.
position will vary over time as soot builds up inside the exhaust system. See "Restrictor
Adjustment" for details.
2 7
Make Sure Pellets are
Not Piling Up
If the pellets pile up over the burn pot, turn the mode switch to
"OFF".
The most likely causes are:
• Restrictor needs adjustment
(see “Restrictor Adjustment” in the installation section of this manual)
• The door, glass, or ashpan is open or has an air leak
• The firepot requires cleaning
• The exhaust system requires cleaning
© Travis Industries
4080728
AA
A
A
AA
A
A
A
A
AA
A
A
A
1 0 0 - 0 1 1 5 6
2 8
Maintenance
Daily Maintenance (whenever using the stove) - Continued
Check Firepot for
Clinkers
If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers (ashes that solidify into a clump).
The most likely causes are:
• Restrictor needs adjustment (see
“Restrictor
Adjustment” in the installation section of this manual)
• Poor pellet quality
• The door or glass has an air leak
• The exhaust system requires cleaning
A
A
A A
AA
A
AA
Cleaning the Firepot
WARNING:
Make sure the heater has fully cooled
(approximately 25 minutes) before opening the door and conducting service.
To clean the firepot, open the door (see page 27) and knock away any debris on the firepot with a screwdriver. If severely clogged, remove the firepot to gain better access.
A
A A
A
A
AA
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Maintenance
Daily Maintenance (whenever using the stove) - Continued
Door Opening
Make sure the heater has fully cooled
(approximately 25 minutes) before opening the door and conducting service.
NOTE: Do not overtighten the pawl. This can permanently damage the latch and prematurely wear out the door gasket.
Phillips
Screwdriver
Bracket (attached to side of heater)
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
Door
Frame
Pawl
Lock Nut
When securing the door, make sure the pawl fits over the bracket before tightening.
With the pawl free of the bracket, the door may be swung open.
2 9
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
3 0
Maintenance
Weekly Maintenance (or every 5 bags of pellets)
Flyash Removal
This heater was designed to allow for easy flyash removal with the included tools. However, to ease maintenance, several pellet stove owners have purchased vacuums specifically made to remove flyash. Furthermore, some of these vacuums are heat-resistant to allow for flyash removal while it is still of the hopper). Standard vacuums may spread the fine particles inside the flyash into the home and are not heat-resistant (hot flyash may cause the internal portion of vacuums to ignite).
Clean the Hopper
Run the stove until the pellets run out. Open the hopper and remove the dust and debris near the bottom of the hopper.
Clean the Heat Exchange Tubes
Open the hopper lid.
WARNING:
The front edge of the hopper lid becomes very hot, do not touch the area below the handle.
WARNING:
This rod becomes very hot during operation. Use the tool to move the cleaner.
AAA
AAA
AAA
© Travis Industries
Store this tool by hanging it on the hanger on the back of the stove.
With the stove cool (or using the door latch tool), move the heat exchange cleaner up and down several times.
Keep the door closed so the flyash does not enter the room.
4080728
1 0 0 - 0 1 1 5 6
Maintenance
Weekly Maintenance (or every 5 bags of pellets) - continued
Cleaning the Optional Gold Surfaces (Door and optional Grill)
Fingerprints or other marks left on gold surfaces may become etched in place if they are not wiped clean prior to turning the stove on. Clean the gold with denatured alcohol and a soft cloth (make sure the heater is cool). Other cleaners may leave a film that may become etched into the gold.
Clean the Baffles
3 1
Use both hands to lift each baffle up and forward. Then tilt the baffle downward to remove any flyash that may have accumulated on top of the baffle.
Cleaning the Baffles
The baffles are located along the top of the firebox. Follow the directions below to remove the baffle and shake any flyash from baffle onto the firebox floor
(NOTE: you do not need to remove the baffle from the firebox).
Left Side Baffle
Right Side Baffle
AAAAA
AAAAA
AAAAA
AAAAA
AAA
AAAAA
AAAAA
b
Left Side Baffle
Note how this tab inserts into this slot in the baffle.
The baffle rests on this ledge at the back of the firebox.
Heat Exchange Tubes
a
Remove the refractory following the directions below.
Remove both refractory side clips.
Remove the firepot.
Lift the refractory up and forward to remove.
© Travis Industries c
Lift the left side baffle up and move it towards the front of the stove. Rotate the back of the baffle forward.
d
With the baffle free of the ledge, bring it downwards and tap any flyash onto the floor of the firebox.
e
Repeat step “b” through
“d” for the right side baffle.
To replace the baffles: follow the above procedure in reverse.
4080728
1 0 0 - 0 1 1 5 6
3 2
Maintenance
Weekly Maintenance (or every 5 bags of pellets) - continued
Sweep Ash Into Ashpan
WARNING:
The firebox becomes very hot during operation. Let the stove cool completely before conducting service.
b
Lift it up and away from the firebox.
Repeat for the opposite side.
a
Swing the side ash trap door up.
Ash Trap
Door
c
Lift the firepot out of its holder.
Firepot
d
Slide the ash pan trap door forward to expose the ash dumps (the door can be removed and cleaned if necessary)
Ash Pan
Trap Door
e
Brush all flyash into the ash dumps, including the flyash inside the firepot holder.
f
Replace the ash trap doors and firepot.
Slide the ash pan trap door forward.
AAA
AAA AA
AA
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Maintenance
Weekly Maintenance (or every 5 bags of pellets) - continued
Check Ashpan, Dispose if necessary
3 3
The ash pan has a built in handle to ease transportation of the ashes.
AAAAAA
AAAAAA
AAAAAA
AA
AA
NOTE:
When replacing the ash pan make sure it is pushed all the way in.
Disposal of Ashes – Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.
Clean the Glass
Open the doors and clean the glass with a non-abrasive glass cleaner and rag.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
3 4
Maintenance
Yearly Maintenance (or every ton)
The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your dealer.
WARNING: Disconnect the power cord and make sure the heater has fully cooled prior to conducting service.
Soot and Flyash: Formation and Need for Removal – The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary.
Clean the Vertical Exhaust Duct
Clean the refractory and the entire area behind it
(both sides).
Remove both refractory clips.
Clean the Exhaust Duct
(the stove must be cool and unplugged)
Clean the Convection
Blower
(the stove must be cool and unplugged)
The convection blower inlet can be vacuumed out (if needed).
If extensive cleaning is needed, it can be removed for cleaning.
© Travis Industries
4080728
Remove these doors to remove fallen flyash and soot (see “Bi-Weekly
a
Open the hopper lid and remove the two screws holding the side doors in place.
Phillips
Screwdriver
b
Swing the side panels open.
c
Remove the cover plates over the exhaust duct
(both sides)
d
Use a vacuum or bottle brush to remove all flyash from the exhaust duct (if the gasket is damaged, replace).
Cover Plate
7/16" Nutdriver
1 0 0 - 0 1 1 5 6
AA
AA
Maintenance
3 5
Yearly Maintenance (or every ton) - continued
Clean the Exhaust Blower
b
Remove the six screws holding the exhaust blower motor in place.
a
Open the hopper lid and remove the screw holding the left door in place.
Remove the restrictor knob.
Swing the left side
11/32" Socket c
Pull the motor out (be careful not to damage the wiring or blades - replace gaskt if it is damaged).
Screwdriver
Blower
Blades
Exhaust Box
Flow Switch
Tube
Nipple (attached to exhaust box)
Restrictor Knob
Exhaust
Motor
Blower
Housing d Clean the blower blades, blower housing, and exhaust box. You may wish to use a vacuum to pull ash out of the vent system. When replacing the motor, take care to align the gasket (if it is damaged, replace). Check the nipple and flow switch tube. Insert a pipe cleaner through the nipple to dislodge any flyash. NOTE: The flow switch will shut off the auger if the tube becomes
Clean the Vent
Flyash will deposit along sections that are horizontal.
AA
AA
Make sure the cap is free of debris
(especially if it has a screen that could become blocked).
Check the vent sections for creosote
AA accumulation (indicating a poorly burning stove). Accumulation over 1/4” must be
AA removed.
On vertically vented systems, the dirtiest portion is often the point where the vent turns upwards
(i.e. the "Tee"). Fortunately, the "Tee" has a builtin clean-out cover. Place a container under the
“Tee”, disconnect the cover and remove all flyash.
While open, use a flashlight to look up the vent to check for build-up.
Warning: Whenever any portion of the pellet vent is disconnected, the joints must be sealed with
RTV 500
°
F. silicone sealant.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
3 6
Maintenance
Yearly Maintenance (or every ton) - continued
Door Seal
!
Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
•
The door gasket must contact the entire perimeter of the door and create an airtight seal. To verify this, open the door, hold a dollar bill against the body of the heater, close the door, and secure the latch. The dollar bill should be held firmly in place (check the entire perimeter of the door. If it is loose or falls out, the door must be adjusted (see the following page).
AA
AA
AA
Door Alignment
Because the door is three-sided, it is crucial the door is aligned correctly.
We recommend that you open the hopper lid and look down upon the door and body of the heater. Use the illustration to the right to determine the correct door alignment.
Correctly Aligned Door
When properly adjusted, the door should be evenly spaced from the front of the stove (and shut tight, compressing the gasket).
Hinge
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
Door
Note how both corners are evenly spaced.
Latch
Latch Too Tight - In the illustration below, the latch is too tight (this is the most common misalignment). Loosen the latch and tighten the hinge.
© Travis Industries
AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA
Note how the gasket separates from the body.
Hinge Too Tight - In the illustration below, the hinge is too tight. Loosen the hinge and tighten the latch.
4080728
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
Note how the gasket separates from the body.
1 0 0 - 0 1 1 5 6
Maintenance
Yearly Maintenance (or every ton) - continued
Adjusting the Door Hinge and Latch
•
The door hinge and door latches may be adjusted to pull the door closer to the body. The illustration below details how to adjust these components. NOTE: Make sure to read the section
"Door Alignment" on the previous page before adjusting the door.
Open the hopper lid and remove the two screws holding the side doors in place.
Latch Adjustment
Loosen the lock nut and twist the pawl (clockwise to tighten, counter-clockwise to loosen).
Tighten the lock nut to secure in place.
Bracket (attached to side of heater)
3 7
Door
Pawl
Lock Nut
Door Hinge Bracket
Dimple (used to monitor hinge bracket position)
Hinge Adjustment
(1) With the door closed, loosen the two bolts going through the door hinge bracket.
(2) Loosen the four nuts used to move the hinge adjusting plate.
Tighten or loosen these nuts to adjust the door hinge bracket. Adjust the upper and lower nuts equally to insure the door remains level.
Tighten the four nuts.
(3) Tighten the two bolts loosened in
© Travis Industries
Door
Hinge Adjusting Plate
4080728
1 0 0 - 0 1 1 5 6
3 8
Maintenance
Yearly Maintenance (or every ton) - continued
Check for Air Leaks Around the Door, Glass, and Ashpan
!
Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
•
Inspect the door gasket to make sure it is fully attached. Use stove gasket cement to re-attach if necessary. If the door gasket is worn or flattened, replace.
•
If the glass is cracked, replace. The glass is held in place by glass clips. See the illustration below for details.
•
Remove the ashpan and inspect the gasket around the perimeter of the ashpan. Re-attach, or replace the gasket if necessary.
Door Trim
Door
Frame
Door Gasket
AAAAA
Attachment
AAAAA
AAAAA
AAAAA
AAAAA
Nuts
5/16"
Nutdriver
AAA
AAA
AAA
Glass Clip
Airwash Bracket
Glass (with channel gasket)
Replacement Parts
ASH DUMP PLATE, LARGE PS/PI
ASHTRAP DOORS
AUGER BEARING PLT, LOWER, LRG
AUGER BUSHING PLATE, UPPER
AUGER DRIVE COLLAR, 1997 & UP
AUGER FLIGHT INSPECTION COVER
AUGER FLIGHT, 2000+ LRG PEL
AUGER MOTOR STOP, P11-P15
AUGER MOTOR, ALL PS/PI
AUGER SUB-ASS'Y - LARGE PEL
BLOWER, COMB, PELLET
BLOWER, CONV, P2-8/11-15/G1
BRUSH, BROOM STYLE - PELLET
BURNPOT ASSY, FIREPOT
CABLE HANGER CLIP
CNTRL BRD, LG PEL (P13-15)
CORD RESTRAINER
DAMPER PLATE S-ASS'Y - LRG PS
DRAFT (FLOW) SWITCH
DRAFT FLOW TUBING
FIRE-BACK, CAST IRON,
FIREBOX BAFFLE, LEFT
FIREBOX BAFFLE, RIGHT
FUSE HOLDER (IN-LINE)
FUSE, 5AMP, 5 - FOR INLINE
FUSE, 6AMP, 5 - CONTROL BOARD
GASKET CEMENT (WHITE), 4oz.
GASKET, ASHPAN 70" BLK 1/2"x1/8" ADH
100-00112
221-22089
93005060
99300164
93005059
210-05199
210-05198
100-00210
93-0695
93005019
99900409
99900428
91002022
93005054
91002024
93005093
91002021
210-02702
91002013
93005096
90-0191
91002020
93005535
98900755
100-04301
99300171
100-04310
100-00203
© Travis Industries
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AA
AAAAAAA
AA
AA
AA
AA
AA
A
A
A
A
Glass Clips
A
A
A
AAA
AAA
AAA
AA
AA
A A
AAAAAAA
AAAAAAA
AAAAAAA
A
A
AAA
AAAAAAA
AAAAAAA
A
A
A
A
AAA
AAA
AAAAAAA
AAAAAAA
AA
AA
AA
Airwash Brackets
GASKET, DOOR 7/8" x 85" WHITE ROPE
GASKET, GLASS 5/8"x137" BLACK
GLASS, FRONT, P12/14, P13
GLASS, SIDE, P12/14, P13
GROMMET, IGNITOR WIRE BLACK RUBBER
GSKT, CLEAN-OUT CVR, 3.250 x 2.750
GSKT, COMB BLOWER (BODY)
GSKT, COMB BLOWER(MOTOR) 7" dia
GSKT, EXHAUST PLATE 4.25"x4.25"
HANDLE, HOPPER LID
HANDLE, PEL CNTRL BOARD 97
HINGE PLATE ASS'Y
HOSE NIPPLE, BARBED
IGNITER, LG PS/PI
KNOB (PHENOLIC), 3/4" dia
LBL, EXHAUST DAMPER
MAGNET w/OUT SHEATH 1x.75" 1/4" THICK
OIL PAN, COMB BLOWER - LG PEL
POWER CORD, PS/PI
REFRACTORY SIDE CLIP, LEFT
REFRACTORY SIDE CLIP, RIGHT
SCRAPER ROD (P12/13/14)
SNAP-DISC - 120deg CERAMIC NO
SNAP-DISC - 120deg NO # NO
SNAP-DISC - 200deg NC # NC
TOOL, GLASS LATCH/RESTRICT0R
WIRE HRNS, PEL, JUMPER, LRGPELLET
WIRE HRNS, PEL, PS/PI 97 & UPLARGE OR SMALL
4080728
99900431
99900398
91002004
91002005
100-02811
100-03235
100-03206
100-03231
100-03230
100-04312
99300094
91002017
100-04307
99300149
100-04241
112-00505
100-02801
210-03216
93005015
210-03831L
210-03831R
211-01660
100-00232
100-00231
100-00233
100-02302
100-00390
100-00391
1 0 0 - 0 1 1 5 6
Normal Operating Sounds
Exhaust Blower
This blower may create a low-pitched hum. This sound will change as the
HEAT OUTPUT is altered.
Auger Motor
When feeding pellets, you may hear the intermittent buzz of this motor running.
3 9
Heat Exchanger Tubes
You may hear the heated air being forced through these tubes by the convection fan.
Convection Fan
The modern high efficiency fan may produce a low hum, particularly on
"HIGH". This sound will change as the FAN setting is changed.
Firepot
As pellets are fed into the firepot, a light clicking sound may be heard.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
4 0
Safety Label
WARNING - DO NOT REMOVE OR COVER THIS LABEL
Listed Pelletized
Solid Fuel Burning Appliance
Also for Use in Mobile Homes
Model: Yankee PS
Serial No:
Report No. 028-S-62-2
Tested to: ASTM E, 1509, and ULC-C1482-M1990 Room Heater Pellet Burning Type (UM) 84 HUD
Electrical Rating: 115V, 60Hz, 3 Amp; Start 3 Amps, Run 1.5 Amps
Maximum Input Rating: 5.5 lbs (2.5kg)/hr
This pellet fired appliance has been tested and listed for use in manufactured (mobile) homes in accordance with OAR 814-23-900 through 814-23-909.
WARNING - FOR MANUFACTURED HOMES: Do not install appliance in a sleeping room. Must utilize outside combustion air inlet (part #99200136) or equivalent. Structural integrity of the manufactured home floor, ceiling, and walls must be maintained.
Install only in accordance with the manufacturer’s installation and operating instructions. Contact local building or fire officials about restrictions and installation inspection in your area.
Use only listed 4 in./100 mm diameter listed type “L” or “PL” venting system. See manufacturer’s installation instructions and local codes for precautions required for passing chimney through a combustible wall or ceiling. Do not connect this appliance to a vent serving another appliance. Inspect and clean exhaust venting system frequently in accordance with manufacturer’s instructions.
May be installed in a sleeping room with use of outside combustion air inlet (Part #99200136) or equivalent.
Minimum Clearance to Combustible Materials (Measured to Stove Top)
Interior Vertical Horizontal Through
Flue Installation the Wall Installation
BACKWALL
C
E
ADJACENT WALL
D
Left Sidewall A
Right Sidewall B
Backwall C
Corner
Flue Vent
D
E
9”
9”
**
3”
3”
9”
9”
3”
3”
3”
A
H G
B
H
D
FLOOR PROTECTOR
Maximum alcove depth 48 in/1220 mm, minimum ceiling height 60 in/1525 mm, minimum alcove width
44 in/1115 mm.
Combustible floor must be protected by a non-combustible material, extending to the front (G) 6 in/150 mm and to the sides (H) 0 in/0 mm.
EXCEPTIONS: Non-combustible floor protection must extend beneath a vent tee when installed.
** This dimension will vary depending on brand of listed type “L” vent. See manual for details.
For use with 1/4 in/6 mm to 5/16 in/7 mm diameter pelletized wood fuels only.
Replace glass only with 5 mm ceramic glass available from your dealer.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route power cord away from unit. Do not route power cord beneath heater.
Operate only with viewing door and ash removal tray tightly closed. Do not obstruct combustion air openings.
The space beneath heater must not be obstructed. Keep all furnishings away from heater.
Mfg. by TRAVIS INDUSTRIES, INC.
10850 117th Pl N.E.
Kirkland, WA 98033
U.S. ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certification under 40 CFR 60.531 by definition
[Wood Heater (A) “Air-to-fuel Ratio”].
Date of Manufacture
2001 2002 2003 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
DO NOT REMOVE THIS LABEL MADE IN U.S.A.
????
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Limited 7 Year Warranty
4 1
To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows:
Check with your dealer in advance for any costs to you when arranging a warranty call.
Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
Years 1 & 2 - COVERAGE: PARTS & LABOR
Firebox Assembly:
Firepot, Firepot Holder, Ash Cleanout Doors, Ashbox or Ash
Dump, Cast Fireback, Heat Exchanger Tubes, Exhaust
Manifold, Exhaust Box
Door Assembly:
Door Frame, Latch Assembly, Glass Retainers
Auger Assembly
Auger Flight, Auger Tube, Auger Bushings
Ceramic Glass
Glass (breakage from thermal shock)
Igniter System
Igniter, Igniter Leads
Electrical System
Auger Motor, Convection Blower, Exhaust Blower, Circuit
Board, Snap Disks, Wiring Harness, Vacuum Switch
Cast Iron Parts
Warranted against breakage, cracking, or burn through
Exclusions:
Paint, Gasketing
Accessories
Ceramic Log with Log Shelf, Remote
Re-Installation Allowance
In cases where heater must be removed from home for repairs, a partial cost of re-installation is covered (pre-authorization required)
One-Way Freight Allowance
One-way freight allowance on pre-authorized repair done at factory is covered.
Years 3 Through 5 - COVERAGE: PARTS & LABOR
Firebox Assembly:
Firepot, Firepot Holder, Ash Cleanout Doors, Ashbox or Ash
Dump, Cast Fireback, Heat Exchanger Tubes, Exhaust
Manifold, Exhaust Box
Exclusions:
Door Assembly:
Door Frame, Latch Assembly, Glass Retainers
Auger Assembly
Auger Flight, Auger Tube, Auger Bushings
One-Way Freight Allowance
One-way freight allowance on pre-authorized repair done at factory is covered.
Paint, Gasketing, Ceramic Glass, Igniter System, Electrical System, Cast Iron Parts, Accessories, Re-Installation Allowance
Years 6 & 7 - COVERAGE: PARTS ONLY
Firebox Assembly:
Firepot, Firepot Holder, Ash Cleanout Doors, Ashbox or Ash Dump, Cast
Fireback, Heat Exchanger Tubes, Exhaust Manifold, Exhaust Box
Exclusions:
Door Assembly:
Door Frame, Latch Assembly, Glass Retainers
Paint, Gasketing, Ceramic Glass, Igniter System, Electrical System, Cast Iron Parts, Accessories, Auger Assembly, Re-Installation
Allowance, One-Way Freight Allowance, Labor
CONDITIONS & EXCLUSIONS
1.
This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with the instructions in
2.
3.
the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.
This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized Travis dealer.
Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered under warranty.
4.
5.
The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation.
Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc.
6.
This Warranty is void if: a.
The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.
b.
c.
The unit is subject to submersion in water or prolonged periods of dampness or condensation.
Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not limited to, improper chimney/venting installation.
Exclusions to this 7 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, 7.
alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or act of God.
8.
This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, chipped or cracked firebrick, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, or the use of fuel other than that for which the unit is configured.
9.
Damage to gold or nickel surfaces caused by fingerprints, scratches, melted items, or other external sources left on the gold or nickel from the use of cleaners other than denatured alcohol is not covered in this warranty.
10.
TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.
11.
This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis appliance without the express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval.
12.
Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed material is not part of this 7 year warranty.
13.
This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes, it is excluded from this warranty.
14.
No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this warranty. TRAVIS
INDUSTRIES, INC. assumes no liability for such warranties or representations.
15.
Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.
16.
If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect.
17.
This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.
IF WARRANTY SERVICE IS NEEDED:
1.
2.
3.
4.
If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the model name and serial number.
Travis Industries has the option of either repairing or replacing the defective component.
If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership.
Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
4 2
Index
"AUGER ON" Light..............................................25
Loading Pellets ................................................. 21
"Maintenance Required" Light ...............................25
Alcove Installation Requirements ..........................12
Auto Mode ........................................................23
Baffle Installation...............................................12
Before You Begin ...............................................7
Weekly Maintenance (or every 5 bags of pellets) ......30
Check Ashpan, Dispose if necessary.....................33
Check Firepot for Clinkers....................................28
Clean the Exhaust Blower ....................................35
Clean the Glass .................................................33
Clean the Heat Exchange Tubes ...........................30
Clean the Hopper ...............................................30
Clean the Vent...................................................35
Clean the Vertical Exhaust Duct............................34
Cleaning the Firepot............................................28
Clearances - Corner Installation ............................8
Clearances - Straight Installation ..........................8
Daily Maintenance (whenever using the stove).........27
Dimensions.......................................................6
Door Seal Verification .........................................12
Electrical Specifications......................................6
EPA Compliance ................................................6
Floor Protection Requirements..............................7
Flyash Removal .................................................30
Fuel.................................................................6
Heating Specifications ........................................6
Important Information .........................................2
Inspect the Burn ................................................27
Installation Example: Class A Chimney Retrofit ........16
Installation Example: Direct "Through-the-wall" Installation.............14
Installation Example: Freestanding Masonry Chimney................19
Installation Example: Interior Vertical Installation ....15
Installation Example: Masonry Fireplace Hearth Stove.......................17
Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove..18
Installation Options ............................................7
Installing the Pellet Vent......................................10
Introduction ......................................................2
Location of Controls ........................................... 20
"Maintenance Required" Light............................... 25
Make Sure Pellets are Not Piling Up ....................... 27
Manual Mode .................................................... 22
Maximum Venting Distance.................................. 9
Mobile Home Requirements.................................. 11
Normal Operating Sounds.................................... 39
Outside Air (used for combustion) ......................... 11
Packing List ..................................................... 7
Pellet Vent Termination ....................................... 10
Pellet Vent Type ................................................ 10
Planning The Installation ..................................... 7
Power Outages ................................................. 26
Restrictor Adjustment......................................... 12
Restrictor Adjustment......................................... 24
Safety Label ..................................................... 40
Safety Notice.................................................... 20
Safety Precautions ............................................ 4
Starting the Heater for the First Time...................... 20
Start-Up Sequence ............................................ 25
Stove Placement ............................................... 7
Sweep Ash Into Ashpan ...................................... 32
The Two Modes of Operation ................................ 21
Thermostat Installation ....................................... 13
Venting the Pellet Stove...................................... 9
Warranty.......................................................... 41
Yearly Maintenance (or every ton)......................... 34
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Introduction
- 2 Important Information
- 4 Safety Precautions
- 6 Heating Specifications
- 6 Dimensions
- 6 Electrical Specifications
- 6 EPA Compliance
- 7 Before You Begin
- 7 Packing List
- 7 Installation Options
- 7 Planning The Installation
- 7 Stove Placement
- 7 Floor Protection Requirements
- 8 Clearances - Straight Installation
- 8 Clearances - Corner Installation
- 9 Venting the Pellet Stove
- 9 Maximum Venting Distance
- 10 Pellet Vent Type
- 10 Installing the Pellet Vent
- 10 Pellet Vent Termination
- 11 Mobile Home Requirements
- 11 Outside Air (used for combustion)
- 12 Alcove Installation Requirements
- 12 Baffle Installation
- 12 Door Seal Verification
- 12 Restrictor Adjustment
- 13 Thermostat Installation
- 14 Installation
- 15 Installation Example: Interior Vertical Installation
- 16 Installation Example: Class A Chimney Retrofit
- 17 Installation Example: Masonry Fireplace Hearth Stove
- 19 Installation Example: Freestanding Masonry Chimney
- 20 Safety Notice
- 20 Location of Controls
- 20 Starting the Heater for the First Time
- 21 Loading Pellets
- 21 The Two Modes of Operation
- 22 Manual Mode
- 23 Auto Mode
- 24 Restrictor Adjustment
- 24 Adjusting the Fan Speed
- 25 Start-Up Sequence
- 25 "AUGER ON" Light
- 25 "Maintenance Required" Light
- 26 "MANUAL AUGER" Button
- 26 Power Outages
- 26 Using a Pellet/Corn Mix with This Heater
- 27 Daily Maintenance (whenever using the stove)
- 27 Inspect the Burn
- 27 Make Sure Pellets are Not Piling Up
- 28 Check Firepot for Clinkers
- 28 Cleaning the Firepot
- 29 Door Opening
- 30 Weekly Maintenance (or every 5 bags of pellets)
- 30 Flyash Removal
- 30 Clean the Hopper
- 30 Clean the Heat Exchange Tubes
- 31 Clean the Baffles
- 32 Sweep Ash Into Ashpan
- 33 Check Ashpan, Dispose if necessary
- 33 Clean the Glass
- 34 Yearly Maintenance (or every ton)
- 34 Clean the Vertical Exhaust Duct
- 35 Clean the Exhaust Blower
- 35 Clean the Vent
- 36 Door Seal
- 39 Normal Operating Sounds
- 40 Safety Label
- 41 Warranty
- 42 Index