advertisement
2 2
Operation
Manual Mode
Manual mode requires the user to turn the heater on and off manually.
To Start
Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes. During this period the lowest “HEAT OUTPUT” light will flash. If the stove does not start in 30 minutes, the stove turns off.
Once up to temperature, the stove will then run at the heat output setting selected on the control panel (see “To Adjust the Heat” below).
F
A
N
H
E
A
T
UP
AUTO
OFF
MANUAL
DOWN
MANUAL
UP
DOWN
START
MANUAL
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
To Shut Down
Move the mode switch to "OFF". The exhaust blower will still run until the heater cools down.
To Adjust the Heat
Press the "Heat” buttons to adjust the heat output.
NOTE: During start-up you may adjust the heat setting. This heat setting will take affect once the start-up sequence is complete.
F
A
N
H
E
A
T
UP
AUTO
OFF
MANUAL
DOWN
MANUAL
UP
DOWN
START
MANUAL
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
H
E
A
T
T
P
O
U
U
T
H
E
A
T
DISCONNECT POWER BEFORE SERVICE
HIGH
MED
LOW
AUTO
MANUAL
UP
AUTO
OFF
MANUAL
DOWN
AUGER
MAINT.
(REQUIRED)
MANUAL
F
A
N
UP START
MANUAL
DOWN
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
© Travis Industries
4080728
These lights indicate the heat output setting.
NOTE: the lights may be difficult to see from an angle.
Press the
“up” or
“down” button to adjust the heat output.
1 0 0 - 0 1 1 5 6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Introduction
- 2 Important Information
- 4 Safety Precautions
- 6 Heating Specifications
- 6 Dimensions
- 6 Electrical Specifications
- 6 EPA Compliance
- 7 Before You Begin
- 7 Packing List
- 7 Installation Options
- 7 Planning The Installation
- 7 Stove Placement
- 7 Floor Protection Requirements
- 8 Clearances - Straight Installation
- 8 Clearances - Corner Installation
- 9 Venting the Pellet Stove
- 9 Maximum Venting Distance
- 10 Pellet Vent Type
- 10 Installing the Pellet Vent
- 10 Pellet Vent Termination
- 11 Mobile Home Requirements
- 11 Outside Air (used for combustion)
- 12 Alcove Installation Requirements
- 12 Baffle Installation
- 12 Door Seal Verification
- 12 Restrictor Adjustment
- 13 Thermostat Installation
- 14 Installation
- 15 Installation Example: Interior Vertical Installation
- 16 Installation Example: Class A Chimney Retrofit
- 17 Installation Example: Masonry Fireplace Hearth Stove
- 19 Installation Example: Freestanding Masonry Chimney
- 20 Safety Notice
- 20 Location of Controls
- 20 Starting the Heater for the First Time
- 21 Loading Pellets
- 21 The Two Modes of Operation
- 22 Manual Mode
- 23 Auto Mode
- 24 Restrictor Adjustment
- 24 Adjusting the Fan Speed
- 25 Start-Up Sequence
- 25 "AUGER ON" Light
- 25 "Maintenance Required" Light
- 26 "MANUAL AUGER" Button
- 26 Power Outages
- 26 Using a Pellet/Corn Mix with This Heater
- 27 Daily Maintenance (whenever using the stove)
- 27 Inspect the Burn
- 27 Make Sure Pellets are Not Piling Up
- 28 Check Firepot for Clinkers
- 28 Cleaning the Firepot
- 29 Door Opening
- 30 Weekly Maintenance (or every 5 bags of pellets)
- 30 Flyash Removal
- 30 Clean the Hopper
- 30 Clean the Heat Exchange Tubes
- 31 Clean the Baffles
- 32 Sweep Ash Into Ashpan
- 33 Check Ashpan, Dispose if necessary
- 33 Clean the Glass
- 34 Yearly Maintenance (or every ton)
- 34 Clean the Vertical Exhaust Duct
- 35 Clean the Exhaust Blower
- 35 Clean the Vent
- 36 Door Seal
- 39 Normal Operating Sounds
- 40 Safety Label
- 41 Warranty
- 42 Index