Thermostat Installation. Lopi Yankee PS

Add to My manuals
42 Pages

advertisement

Thermostat Installation. Lopi Yankee PS | Manualzz

Installation

(For Qualified Installers Only)

1 3

Thermostat Installation

!

Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater).

A thermostat is included with this heater (part # 99300650). Follow the directions below to install.

1 Attach the thermostat wire to the circuit board

(see the illustration below). Route the wire through the back of the heater (away from any hot or moving components).

50 60 70 80 90

Pull the cover off the thermostat

50 60 70 80 90

Run the thermostat wires through the wall (cut off excess wire, leaving 6” of slack).

Robertshaw

Attach the quick-connects to the two posts near the molex connector on the circuit board (orientation does not mater).

2 Determine a location for the thermostat that is within range of the 20' length of thermostat wire.

It should be centralized in the room and away from the heater. The wire may be routed externally on the wall or behind the wall

(preferred).

3 Follow the directions to the right to attach the thermostat and thermostat wires.

Expose 1/2” of wire and attach to these two posts.

Standard

Screwdriver

Attach the thermostat to the wall through these two holes.

© Travis Industries

4080728