Installation
(For Qualified Installers Only)
1 3
Thermostat Installation
!
Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater).
A thermostat is included with this heater (part # 99300650). Follow the directions below to install.
1 Attach the thermostat wire to the circuit board
(see the illustration below). Route the wire through the back of the heater (away from any hot or moving components).
50 60 70 80 90
Pull the cover off the thermostat
50 60 70 80 90
Run the thermostat wires through the wall (cut off excess wire, leaving 6” of slack).
Robertshaw
Attach the quick-connects to the two posts near the molex connector on the circuit board (orientation does not mater).
2 Determine a location for the thermostat that is within range of the 20' length of thermostat wire.
It should be centralized in the room and away from the heater. The wire may be routed externally on the wall or behind the wall
(preferred).
3 Follow the directions to the right to attach the thermostat and thermostat wires.
Expose 1/2” of wire and attach to these two posts.
Standard
Screwdriver
Attach the thermostat to the wall through these two holes.
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
advertisement
Related manuals
advertisement
Table of contents
- 2 Introduction
- 2 Important Information
- 4 Safety Precautions
- 6 Heating Specifications
- 6 Dimensions
- 6 Electrical Specifications
- 6 EPA Compliance
- 7 Before You Begin
- 7 Packing List
- 7 Installation Options
- 7 Planning The Installation
- 7 Stove Placement
- 7 Floor Protection Requirements
- 8 Clearances - Straight Installation
- 8 Clearances - Corner Installation
- 9 Venting the Pellet Stove
- 9 Maximum Venting Distance
- 10 Pellet Vent Type
- 10 Installing the Pellet Vent
- 10 Pellet Vent Termination
- 11 Mobile Home Requirements
- 11 Outside Air (used for combustion)
- 12 Alcove Installation Requirements
- 12 Baffle Installation
- 12 Door Seal Verification
- 12 Restrictor Adjustment
- 13 Thermostat Installation
- 14 Installation
- 15 Installation Example: Interior Vertical Installation
- 16 Installation Example: Class A Chimney Retrofit
- 17 Installation Example: Masonry Fireplace Hearth Stove
- 19 Installation Example: Freestanding Masonry Chimney
- 20 Safety Notice
- 20 Location of Controls
- 20 Starting the Heater for the First Time
- 21 Loading Pellets
- 21 The Two Modes of Operation
- 22 Manual Mode
- 23 Auto Mode
- 24 Restrictor Adjustment
- 24 Adjusting the Fan Speed
- 25 Start-Up Sequence
- 25 "AUGER ON" Light
- 25 "Maintenance Required" Light
- 26 "MANUAL AUGER" Button
- 26 Power Outages
- 26 Using a Pellet/Corn Mix with This Heater
- 27 Daily Maintenance (whenever using the stove)
- 27 Inspect the Burn
- 27 Make Sure Pellets are Not Piling Up
- 28 Check Firepot for Clinkers
- 28 Cleaning the Firepot
- 29 Door Opening
- 30 Weekly Maintenance (or every 5 bags of pellets)
- 30 Flyash Removal
- 30 Clean the Hopper
- 30 Clean the Heat Exchange Tubes
- 31 Clean the Baffles
- 32 Sweep Ash Into Ashpan
- 33 Check Ashpan, Dispose if necessary
- 33 Clean the Glass
- 34 Yearly Maintenance (or every ton)
- 34 Clean the Vertical Exhaust Duct
- 35 Clean the Exhaust Blower
- 35 Clean the Vent
- 36 Door Seal
- 39 Normal Operating Sounds