Possible error types (FMI). Krone Messages - Parameters, EzBA RP
Publicitate
Publicitate
3
3.1
3.1
Error Messages
Possible error types (FMI)
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
10
11
12
13
8
9
6
7
4
5
2
3
FMI
0
1
18
19
20
21
31
14
15
16
17
Meaning
The upper limit value was greatly exceeded.
The lower limit value was far below the required one.
The data is not permitted.
There is an overvoltage or a short circuit to supply voltage.
There is an undervoltage or a short circuit to ground.
A cable is broken or amperage is too low.
There is a short circuit to ground or amperage is too low.
The mechanics do not respond or the expected result was not achieved.
The frequency is not permitted.
There is an abnormal update rate.
There is an abnormal rate of change.
The error cause is unknown.
There is an internal error.
The values of the calibration are outside the value range.
Particular instructions are required.
The upper limit value has been reached.
The upper limit value has been exceeded.
The lower limit value has been reached.
The lower limit value has not been reached.
There is a CAN communication failure.
The data deviates upwards.
The data deviates downwards.
The condition has been fulfilled.
3.2
Error list
>>>
2
Fehlerliste_D2515020105300029_en [ } 7]
6
Round baler
Supplement to operating instructions 150001622_00_en
Error list
Software version: D2515020105400029_200
Control unit: KMC
Page 1
Error number
KMC-520192-19
Error text
CAN1 - CAN disturbance between control units
KMC-520193-19 CAN2 - CAN disturbance between control units
KMC-520194-19 CAN3 - CAN disturbance between control units
KMC-520195-19 CAN4 - CAN disturbance between control units
KMC-520198-12 Control unit - Internal Error
KMC-520232-12
KMC-520234-31
KMC-521100-3
KMC-521100-4
KMC-521100-5
KMC-521100-6
KMC-521101-3
KMC-521101-4
KMC-521101-5
KMC-521101-6
KMC-521102-3
Vehicle identification number -
Internal Error
System check with KMC failed
Voltage group UB1 - Overvoltage
Voltage group UB1 - Undervoltage
Voltage group UB1 - Ground fault
Voltage group UB1 - Overload
Voltage group UB2 - Overvoltage
Voltage group UB2 - Undervoltage
Voltage group UB2 - Ground fault
Voltage group UB2 - Overload
Voltage group UB3 - Overvoltage
Description
There is a CAN disturbance between control units on CAN 1.
Figure
There is a CAN disturbance between control units on CAN 2.
There is a CAN disturbance between control units on CAN 3.
There is a CAN disturbance between control units on CAN 4.
An internal error in the control unit which was actuated by defective software or hardware.
Vehicle identification number has not been initialised.
With the KMC the cross-controller adjustment of system-relevant machine data has failed.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
The maximum load on the supply voltage has been exceeded.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
Page 2
Error number
KMC-521102-4
KMC-521102-5
KMC-521102-6
KMC-521103-3
Error text
Voltage group UB3 - Undervoltage
Voltage group UB3 - Ground fault
Voltage group UB3 - Overload
Voltage group UB4 - Overvoltage
KMC-521103-4 Voltage group UB4 - Undervoltage
KMC-521103-5
KMC-521103-6
KMC-521104-3
KMC-521104-4
KMC-521104-5
KMC-521104-6
KMC-521105-3
KMC-521105-4
KMC-521105-5
KMC-521105-6
KMC-521106-11
Voltage group UB4 - Ground fault
Voltage group UB4 - Overload
Voltage group UB5 - Overvoltage
Voltage group UB5 - Undervoltage
Voltage group UB5 - Ground fault
Voltage group UB5 - Overload
Voltage group UB6 - Overvoltage
Voltage group UB6 - Undervoltage
Voltage group UB6 - Ground fault
Voltage group UB6 - Overload
Supply voltage sensors - General disturbance
Description
The input voltage of the corresponding voltage group is too low.
Figure
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The voltage has been switched off due to an overload or a short circuit on the supply voltage of the sensors.
Page 3
Error number
KMC-521107-3
KMC-521107-4
KMC-521108-11
KMC-521109-11
KMC-521110-11
KMC-521111-11
KMC-521112-11
Error text
Supply voltage - Overvoltage
Supply voltage - Undervoltage
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Description
The power supply on the UE connection is too high.
The power supply on the UE connection is too low.
The voltage group relay UB1 has not passed the self-test.
Figure
The voltage group relay UB2 has not passed the self-test.
The voltage group relay UB3 has not passed the self-test.
The voltage group relay UB4 has not passed the self-test.
The voltage group relay UB5 has not passed the self-test.
KMC-521113-11 Control unit - General disturbance The voltage group relay UB6 has not passed the self-test.
KMC-521114-11
KMC-521115-11
KMC-521116-11
KMC-521117-11
KMC-521118-11
KMC-521320-2
Sensor supply voltage U1 - General disturbance
Sensor supply voltage U2 - General disturbance
Sensor supply voltage U3 - General disturbance
Sensor supply voltage U4 - General disturbance
Voltage group relay UB2 - General disturbance
Machine configuration - Logic error electronics
The voltage group Uext1 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext2 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext3 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext4 for supplying the sensors is defective, for example due to overload or short circuit.
Platform fault for BiG X only: A disturbance was detected at the intake/header (broken cable/short circuit to one of the valves Q55 - Q58 or a broken cable/short circuit from relay Q72). The voltage group relay
UB2 was therefore switched off.
Configuration of the machine is not compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
Page 4
Error number
KMC-521351-11
Error text
Control unit - General disturbance
Description
KMC-522000-7
KMC-522001-7
KMC-522005-2
Quick-stop switch - Logic fault mechanics
The quick-stop switch has been activated.
Quick-stop retaining bracket - Logic fault mechanics
The quick-stop retaining bracket has been activated.
universal shaft - Logic error electronics
KMC-522005-16 universal shaft - Upper limit value exceeded
The universal shaft rotates and the operating status is road mode.
The universal shaft is rotating faster than permitted.
KMC-522010-7
KMC-522011-7
Blade cassette movement prompt -
Logic fault mechanics
The blade cassette must be lifted.
Blade cassette movement prompt -
Logic fault mechanics
The blade cassette must be lowered.
KMC-522012-7
KMC-522014-7
Blade cassette not up - Logic fault mechanics
The blade cassette is not up.
Blade cassette movement prompt -
Logic fault mechanics
The blade cassette must be pressurised.
KMC-522015-7 Blade cassette Timeout - Logic fault mechanics
Movement of the blade cassette has a timeout.
KMC-522020-7
KMC-522021-7
KMC-522022-7
KMC-522023-18
KMC-522024-7
Tying net not pulled - Logic fault mechanics
Tying net stopped - Logic fault mechanics
Tying net is being pulled - Logic fault mechanics
Feed roller below minimum speed -
Lower limit value below minimum
Tying net not cut off - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The feed roller is below the minimum speed when the wrapping and tying material is pulled.
The wrapping and tying material has not been cut off.
KMC-522025-7 Tying net not pulled - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
Figure
Page 5
Error number
KMC-522026-7
KMC-522027-7
KMC-522028-7
Error text
Tying net stopped - Logic fault mechanics
Tying net is being pulled - Logic fault mechanics
Tying net not cut off - Logic fault mechanics
Description
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The wrapping and tying material has not been cut off.
Figure
KMC-522029-7
KMC-522030-7
KMC-522031-7
KMC-522033-7
Tying twine not pulled - Logic fault mechanics
Tying twine stopped - Logic fault mechanics
Tying twine is being pulled - Logic fault mechanics
KMC-522032-18 Feed roller below minimum speed -
Lower limit value below minimum
Tying twine not cut off - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The feed roller is below the minimum speed when the wrapping and tying material is pulled.
The wrapping and tying material has not been cut off.
KMC-522034-7 Tying twine Timeout - Logic fault mechanics
KMC-522035-16 Maximum filling exceeded - Upper limit value exceeded
The twine arms could not be moved within the stipulated time into the required position.
The bale chamber has been filled above the maximum.
KMC-522038-18
KMC-522040-16
KMC-522041-16
KMC-522044-7
Slip of bale formation conveyor -
Lower limit value below minimum
Left bale conical - Upper limit value exceeded
Right bale conical - Upper limit value exceeded
Position of tailgate unclear - Logic fault mechanics
The setpoint speed of the bale formation conveyor of the bale chamber was below the minimum.
The filling between the left and right sides of the bale differs too much, too large on the left.
The filling between the left and right sides of the bale differs too much, too large on the right.
The position of the tailgate could not be determined.
KMC-522045-7 Open tailgate Timeout - Logic fault mechanics
The tailgate could not be opened within the stipulated time.
KMC-522046-7 Close tailgate Timeout - Logic fault mechanics
The tailgate could not be closed within the stipulated time.
Page 6
Error number
KMC-522048-7
Error text Description
Tailgate open - Logic fault mechanics The tailgate is open during road operating mode.
KMC-522049-7
KMC-522050-18
Tailgate open - Logic fault mechanics An open tailgate was detected, although no tying has occurred since it was last closed.
Rotational speed universal shaft -
Lower limit value below minimum
The PTO speed is too low.
KMC-522051-7
KMC-522052-7
Position of tailgate - Logic fault mechanics
Position of lifter - Logic fault mechanics
The position of the tailgate is not correct.
The position of the lifter is not correct.
Figure
KMC-522053-7
KMC-522054-7
Position wrapping table - Logic fault mechanics
The position of the wrapping table is not correct.
Position wrapping arm - Logic fault mechanics
The position of the wrapping arm is not correct.
KMC-522055-7
KMC-522056-7
Position of holding arms - Logic fault mechanics
The position of the holding arm is not correct.
Transfer Timeout - Logic fault mechanics
The transfer has a timeout.
KMC-522057-7 Bale on lifter - Logic fault mechanics The bale is not on the lifter.
KMC-522058-7 Bale on wrapping table - Logic fault mechanics
There is a bale on the wrapping table.
KMC-522060-7
KMC-522066-7
KMC-522070-7
KMC-522075-7
Tailgate automatic system Timeout -
Logic fault mechanics
The tailgate automatic system has a
Timeout
Lifter Timeout - Logic fault mechanics The lifter of the bale transfer could not be moved within the stipulated time into the required position.
Wrapping table Timeout - Logic fault mechanics
Film tear on one side - Logic fault mechanics
The wrapping table could not be moved within the stipulated time into the required position.
The film is torn on one side.
KMC-522076-7 Film tear on both sides - Logic fault mechanics
The film is torn on both sides.
Page 7
Error number
KMC-522078-16
KMC-522079-18
KMC-522080-7
KMC-522081-7
KMC-522082-7
KMC-522083-7
Error text
Moisture measurement - Upper limit value exceeded
Moisture measurement - Lower limit value below minimum
Tying film not pulled - Logic fault mechanics
Tying film stopped - Logic fault mechanics
Tying film is being pulled - Logic fault mechanics
Tying film not cut off - Logic fault mechanics
Description
The upper moisture limit value was below the minimum during the moisture measurement.
The lower moisture limit value was below the minimum during the moisture measurement.
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The wrapping and tying material has not been cut off.
Figure
KMC-522084-7
KMC-522085-7
KMC-522086-7
KMC-522087-7
Tying twine not pulled - Logic fault mechanics
Tying twine stopped - Logic fault mechanics
Tying twine is being pulled - Logic fault mechanics
Tying twine not cut off - Logic fault mechanics
The wrapping and tying material was not received by/pulled from the bale when tying is activated.
The wrapping and tying material stops after a certain time when tying is activated.
The wrapping and tying material is being pulled from the bale even though tying has not started.
The wrapping and tying material has not been cut off.
KMC-522088-7
KMC-522089-7
KMC-522091-18
Tying net Timeout movement - Logic fault mechanics
Tying film Timeout movement - Logic fault mechanics
Baling pressure below minimum -
Lower limit value below minimum
The rocker arm could not be moved to the required position within the specified time
The rocker arm could not be moved to the required position within the specified time.
The baling pressure is below the minimum required value
KMC-522093-7
KMC-522094-7
Position of tailgate Combi unclear -
Logic fault mechanics
The position of the tailgate could not be determined.
Open tailgate Combi Timeout - Logic fault mechanics
The tailgate could not be opened within the stipulated time.
KMC-522095-7 Close tailgate Combi Timeout - Logic fault mechanics
The tailgate could not be closed within the stipulated time.
Page 8
Error number
KMC-522097-7
KMC-522098-7
KMC-522101-3
Error text
Tailgate Combi open - Logic fault mechanics
Description
The tailgate is open during road operating mode.
Tailgate Combi open - Logic fault mechanics
Sensor B01 Speed of bale chamber -
Cable break
An open tailgate was detected, although no tying has occurred since it was last closed.
Figure
KMC-522101-4
KMC-522102-3
Sensor B01 Speed of bale chamber -
Short circuit to ground or UB
Sensor B02 Tying process active -
Cable break
KMC-522102-4
KMC-522103-3
Sensor B02 Tying process active -
Short circuit to ground or UB
Sensor B74 Acceleration wrapping table - Cable break
KMC-522103-4
KMC-522105-3
Sensor B74 Acceleration wrapping table - Short circuit to ground or UB
Sensor B05 Slip of bale formation conveyor - Cable break
KMC-522105-4
KMC-522106-3
Sensor B05 Slip of bale formation conveyor - Short circuit to ground or
UB
Sensor B06 Tying process active 1 twine tying - Cable break
KMC-522106-4
KMC-522107-3
Sensor B06 Tying process active 1 twine tying - Short circuit to ground or UB
Sensor B07 Tying process active 2 twine tying - Cable break
KMC-522107-4
KMC-522108-3
Sensor B07 Tying process active 2 twine tying - Short circuit to ground or UB
Sensor B08 Bale chute top - Cable break
KMC-522108-4 Sensor B08 Bale chute top - Short circuit to ground or UB
Page 9
Error number
KMC-522109-3
Error text
Sensor B09 Filling display on left -
Short circuit to UB
Description
KMC-522109-4
KMC-522110-3
Sensor B09 Filling display on left -
Cable break or short circuit to ground
Sensor B10 Filling display on right -
Short circuit to UB
KMC-522110-4
KMC-522111-3
KMC-522111-4
KMC-522112-3
KMC-522112-4
KMC-522113-3
Sensor B10 Filling display on right -
Cable break or short circuit to ground
Sensor B11 Lock hook bale chamber on left - Cable break
Sensor B11 Lock hook bale chamber on left - Short circuit to ground or UB
Sensor B12 Lock hook bale chamber on right - Cable break
Sensor B12 Lock hook bale chamber on right - Short circuit to ground or
UB
Sensor B13 Position of twine guide slide - Cable break
KMC-522113-4
KMC-522114-3
KMC-522114-4
KMC-522115-3
Sensor B13 Position of twine guide slide - Short circuit to ground or UB
Sensor B14 Bale chamber open -
Cable break
Sensor B14 Bale chamber open -
Short circuit to ground or UB
Sensor B15 ejecting the bale - Cable break
KMC-522115-4
KMC-522120-3
Sensor B15 ejecting the bale - Short circuit to ground or UB
Sensor B20 Zero position wrapping arm - Cable break
KMC-522120-4 Sensor B20 Zero position wrapping arm - Short circuit to ground or UB
Figure
Error number
KMC-522121-3
Error text
Sensor B21 Position wrapping arm -
Cable break
Description
KMC-522121-4
KMC-522122-3
Sensor B21 Position wrapping arm -
Short circuit to ground or UB
Sensor B22 Left holding arm open -
Cable break
KMC-522122-4
KMC-522123-3
Sensor B22 Left holding arm open -
Short circuit to ground or UB
Sensor B23 Right holding arm open -
Cable break
KMC-522123-4
KMC-522124-3
Sensor B23 Right holding arm open -
Short circuit to ground or UB
Sensor B24 Film tear detection -
Cable break
KMC-522124-4
KMC-522126-3
Sensor B24 Film tear detection -
Short circuit to ground or UB
Sensor B26 Bale lifter down - Cable break
KMC-522126-4
KMC-522127-3
Sensor B26 Bale lifter down - Short circuit to ground or UB
Sensor B27 Position wrapping table -
Short circuit to UB
KMC-522127-4
KMC-522135-3
Sensor B27 Position wrapping table -
Cable break or short circuit to ground
Sensor B35 Left holding arm closed -
Cable break
KMC-522135-4
KMC-522136-3
Sensor B35 Left holding arm closed -
Short circuit to ground or UB
Sensor B36 Right holding arm closed
- Cable break
KMC-522136-4 Sensor B36 Right holding arm closed
- Short circuit to ground or UB
Page 10
Figure
Error number
KMC-522140-3
Error text
Sensor B40 Blade group B swivelled out - Cable break
Description
KMC-522140-4
KMC-522141-3
Sensor B40 Blade group B swivelled out - Short circuit to ground or UB
Sensor B41 Blade group B swivelled in - Cable break
KMC-522141-4
KMC-522142-3
Sensor B41 Blade group B swivelled in - Short circuit to ground or UB
Sensor B42 Blade group A swivelled out - Cable break
KMC-522142-4
KMC-522143-3
Sensor B42 Blade group A swivelled out - Short circuit to ground or UB
Sensor B43 Blade group A swivelled in - Cable break
KMC-522143-4
KMC-522146-3
Sensor B43 Blade group A swivelled in - Short circuit to ground or UB
Sensor B46 Blade control shaft 0 -
Cable break
KMC-522146-4
KMC-522147-3
Sensor B46 Blade control shaft 0 -
Short circuit to ground or UB
Sensor B47 Blade control shaft 1 -
Cable break
KMC-522147-4
KMC-522150-3
Sensor B47 Blade control shaft 1 -
Short circuit to ground or UB
Sensor B50 Bale detection wrapping table - Short circuit to UB
KMC-522150-4
KMC-522151-3
Sensor B50 Bale detection wrapping table - Cable break or short circuit to ground
Sensor B09 Filling display on left -
Short circuit to UB
KMC-522151-4 Sensor B09 Filling display on left -
Cable break or short circuit to ground
Page 11
Figure
Error number
KMC-522152-3
Error text
Sensor B10 Filling display on right -
Short circuit to UB
Description
KMC-522152-4
KMC-522161-3
Sensor B10 Filling display on right -
Cable break or short circuit to ground
Sensor B61 Tying 1 (passive) - Short circuit to UB
KMC-522161-4
KMC-522162-3
Sensor B61 Tying 1 (passive) - Cable break or short circuit to ground
Sensor B62 Tying 2 (active) - Cable break
KMC-522162-4
KMC-522163-3
Sensor B62 Tying 2 (active) - Short circuit to ground or UB
Sensor B63 Tying 3 (active) (twine) -
Short circuit to UB
KMC-522163-4
KMC-522167-3
Sensor B63 Tying 3 (active) (twine) -
Cable break or short circuit to ground
Sensor B67 Blade pre-selection active - Cable break
KMC-522167-4
KMC-522168-3
Sensor B67 Blade pre-selection active - Short circuit to ground or UB
Sensor B68 Blade pre-selection inactive - Cable break
KMC-522168-4
KMC-522169-3
Sensor B68 Blade pre-selection inactive - Short circuit to ground or
UB
Sensor B69 blade active - Cable break
KMC-522169-4
KMC-522177-3
Sensor B69 blade active - Short circuit to ground or UB
Sensor B77 Bale lifter position -
Short circuit to UB
KMC-522177-4 Sensor B77 Bale lifter position -
Cable break or short circuit to ground
Page 12
Figure
Error number
KMC-522182-3
Error text
Sensor B82 direction display - Short circuit to UB
Description
KMC-522182-4
KMC-522183-3
Sensor B82 direction display - Cable break or short circuit to ground
Sensor B83 Overload protection belt
- Cable break
KMC-522183-4
KMC-522184-3
Sensor B83 Overload protection belt
- Short circuit to ground or UB
Sensor B84 baling pressure - Short circuit to UB
KMC-522184-4
KMC-522202-3
Sensor B84 baling pressure - Cable break or short circuit to ground
Sensor B02 Tying process active -
Cable break
KMC-522202-4
KMC-522206-3
Sensor B02 Tying process active -
Short circuit to ground or UB
Sensor B06 Tying process active 1 twine tying - Cable break
KMC-522206-4
KMC-522244-0
Sensor B06 Tying process active 1 twine tying - Short circuit to ground or UB
Switch/momentary switch S4
Loosen holding arm -
KMC-522244-0 Switch/momentary switch S4
Loosen holding arm -
KMC-522245-3
KMC-522245-4
KMC-522250-16
Momentary switch S5 tying insert net
Switch/momentary switch S5 Tying insert net - Cable break
Momentary switch S5 tying insert net
Switch/momentary switch S5 Tying insert net - Short circuit to ground or
UB
Sensor
- B58 Weight measurement wrapping table at rear right
- B59 Weight measurement wrapping table at front left
- Upper limit value exceeded
Page 13
Figure
Error number
KMC-522250-18
KMC-522251-16
KMC-522251-18
KMC-522300-3
Error text
Sensor
- B58 Weight measurement wrapping table at rear right
- B59 Weight measurement wrapping table at front left
- Lower limit value below minimum
Sensor
- B57 Weight measurement wrapping table at rear left
- B60 Weight measurement wrapping table at front right
- Upper limit value exceeded
Sensor
- B57 Weight measurement wrapping table at rear left
- B60 Weight measurement wrapping table at front right
- Lower limit value below minimum
Engine M1 Tying 1 (passive) net -
Cable break or short circuit to UB
Description
KMC-522300-6
KMC-522301-3
KMC-522301-6
KMC-522303-3
KMC-522303-6
KMC-522305-3
Engine M1 Tying 1 (passive) net -
Short circuit to ground
Actuator K01/K20 Pick-up/blade group control system B - Cable break or short circuit to UB
Actuator K01/K20 Pick-up/blade group control system B - Short circuit to ground
Actuator K03/K21 Blade cassette/ blade group control system A - Cable break or short circuit to UB
Actuator K03/K21 Blade cassette/ blade group control system A - Short circuit to ground
Actuator K05 Circulation valve block -
Cable break or short circuit to UB
KMC-522305-6
KMC-522306-3
Actuator K05 Circulation valve block -
Short circuit to ground
Actuator Q06 Drive of wrapping arm -
Cable break or short circuit to UB
KMC-522306-6
KMC-522307-3
Actuator Q06 Drive of wrapping arm -
Short circuit to ground
Actuator K07 Close bale chamber -
Cable break or short circuit to UB
Page 14
Figure
Error number
KMC-522307-6
Error text
Actuator K07 Close bale chamber -
Short circuit to ground
Description
KMC-522308-3
KMC-522308-6
Actuator K08 Open bale chamber -
Cable break or short circuit to UB
Actuator K08 Open bale chamber -
Short circuit to ground
KMC-522310-3
KMC-522310-6
Actuator K10 Bale transfer wrapping table - Cable break or short circuit to
UB
Actuator K10 Bale transfer wrapping table - Short circuit to ground
KMC-522311-3
KMC-522311-6
KMC-522312-3
KMC-522312-6
Actuator K11 Move bale turner -
Cable break or short circuit to UB
Actuator K11 Move bale turner -
Short circuit to ground
Actuator K12 Raise bale transfer -
Cable break or short circuit to UB
Actuator K12 Raise bale transfer -
Short circuit to ground
KMC-522313-3
KMC-522313-6
Actuator K13 Lower bale transfer -
Cable break or short circuit to UB
Actuator K13 Lower bale transfer -
Short circuit to ground
KMC-522314-3
KMC-522314-6
KMC-522316-3
KMC-522316-6
Actuator K14 Speed of wrapping table film tear - Cable break or short circuit to UB
Actuator K14 Speed of wrapping table film tear - Short circuit to ground
Actuator K16 Open holding arms -
Cable break or short circuit to UB
Actuator K16 Open holding arms -
Short circuit to ground
KMC-522317-3 Actuator K17 Close holding arms -
Cable break or short circuit to UB
Page 15
Figure
Error number
KMC-522317-6
Error text
Actuator K17 Close holding arms -
Short circuit to ground
Description
KMC-522319-3
KMC-522319-6
Actuator K19 Wrapping arm brake -
Cable break or short circuit to UB
Actuator K19 Wrapping arm brake -
Short circuit to ground
KMC-522320-3
KMC-522320-6
KMC-522321-3
KMC-522321-6
Actuator K01/K20 Pick-up/blade group control system B - Cable break or short circuit to UB
Actuator K01/K20 Pick-up/blade group control system B - Short circuit to ground
Actuator K21 Blade control shaft A active - Cable break or short circuit to
UB
Actuator K21 Blade control shaft A active - Short circuit to ground
KMC-522326-3
KMC-522326-6
KMC-522327-3
KMC-522327-6
KMC-522330-3
KMC-522330-6
Actuator Q26 Lower feed rocker arm up to year of manufacture 2018 -
Cable break or short circuit to UB
Actuator Q26 Lower feed rocker arm up to year of manufacture 2018 -
Short circuit to ground
Actuator Q27 Raise feed rocker arm up to year of manufacture 2018 -
Cable break or short circuit to UB
Actuator Q27 Raise feed rocker arm up to year of manufacture 2018 -
Short circuit to ground
Actuator Q30 baling pressure - Cable break or short circuit to UB
Actuator Q30 baling pressure - Short circuit to ground
KMC-522333-3
KMC-522333-6
Actuator K55 Central lubrication grease - Cable break or short circuit to UB
Actuator K55 Central lubrication grease - Short circuit to ground
KMC-522338-3 Actuator K38 Pilot valve 1 - Cable break or short circuit to UB
Page 16
Figure
Error number
KMC-522338-6
Error text
Actuator K38 Pilot valve 1 - Short circuit to ground
KMC-522339-3
KMC-522339-6
Actuator K39 Pilot valve 2 - Cable break or short circuit to UB
Actuator K39 Pilot valve 2 - Short circuit to ground
KMC-522341-3
KMC-522341-6
Actuator Q41 Soft core setting -
Cable break or short circuit to UB
Actuator Q41 Soft core setting -
Short circuit to ground
KMC-522346-3
KMC-522346-6
Actuator K46 Blade pre-selection -
Cable break or short circuit to UB
Actuator K46 Blade pre-selection -
Short circuit to ground
Description
KMC-522350-3
KMC-522350-6
Actuator Q50 Tying coupling - Cable break or short circuit to UB
Actuator Q50 Tying coupling - Short circuit to ground
KMC-522352-3
KMC-522352-6
Actuator Q52 Pilot valve 3 - Cable break or short circuit to UB
Actuator Q52 Pilot valve 3 - Short circuit to ground
KMC-522353-3
KMC-522353-6
Actuator K53 Holding arms on left -
Cable break or short circuit to UB
Actuator K53 Holding arms on left -
Short circuit to ground
KMC-522354-3
KMC-522354-6
Actuator K54 Holding arms on right -
Cable break or short circuit to UB
Actuator K54 Holding arms on right -
Short circuit to ground
KMC-522373-3 Actuator K73 Additional valve baling pressure - Cable break or short circuit to UB
Page 17
Figure
Error number
KMC-522373-6
Error text
Actuator K73 Additional valve baling pressure - Short circuit to ground
Description
KMC-522375-3
KMC-522375-6
Actuator Q75 Bale lifter speed -
Cable break or short circuit to UB
Actuator Q75 Bale lifter speed -
Short circuit to ground
KMC-522376-3
KMC-522376-6
Actuator Q76 Bale lifter direction of motion - Cable break or short circuit to UB
Actuator Q76 Bale lifter direction of motion - Short circuit to ground
KMC-522400-3
KMC-522400-6
Engine M2 Tying 2 (active) net -
Cable break or short circuit to UB
Engine M2 Tying 2 (active) net -
Short circuit to ground
KMC-522401-3
KMC-522401-6
Engine M3 Tying 3 (twine) - Cable break or short circuit to UB
Engine M3 Tying 3 (twine) - Short circuit to ground
KMC-522420-3
KMC-522420-6
Lamp E20 Working lights net roll -
Cable break or short circuit to UB
Lamp E20 Working lights net roll -
Short circuit to ground
KMC-522421-3
KMC-522421-6
Lamp E21 Working lights chamber film wrapping - Cable break or short circuit to UB
Lamp E21 Working lights chamber film wrapping - Short circuit to ground
KMC-522422-3
KMC-522422-6
Lamp
- E22 Maintenance lighting side hood left
- E23 Maintenance lighting side hood right
- Cable break or short circuit to UB
Lamp
- E22 Maintenance lighting side hood left
- E23 Maintenance lighting side hood right
- Short circuit to ground
Page 18
Figure
Error number
KMC-522431-3
KMC-522431-6
KMC-522433-3
KMC-522433-6
KMC-522456-3
Error text
Lamp
- E31 Working lights wrapping table on left
- E32 Working lights wrapping table on right
- Cable break or short circuit to UB
Lamp
- E31 Working lights wrapping table on left
- E32 Working lights wrapping table on right
- Short circuit to ground
Lamp
- E33 Rear working lights, left
- E34 Rear working lights, right
- Cable break or short circuit to UB
Lamp
- E33 Rear working lights, left
- E34 Rear working lights, right
- Short circuit to ground
Actuator K56 Fill clamping hydraulics
- Cable break or short circuit to UB
Description
KMC-522456-6
KMC-522462-3
Actuator K56 Fill clamping hydraulics
- Short circuit to ground
Actuator K12 Raise bale transfer -
Cable break or short circuit to UB
KMC-522462-6
KMC-522463-3
Actuator K12 Raise bale transfer -
Short circuit to ground
Actuator K13 Lower bale transfer -
Cable break or short circuit to UB
KMC-522463-6
KMC-522471-3
KMC-522471-6
Actuator K13 Lower bale transfer -
Short circuit to ground
Actuator K03/K21 Blade cassette/ blade group control system A - Cable break or short circuit to UB
Actuator K03/K21 Blade cassette/ blade group control system A - Short circuit to ground
KMC-522500-0
KMC-522510-0
The wrong configuration values were saved
Error from force measurement amplifier
1
Figure
Page 19
Error number
KMC-522511-0
KMC-522512-0
KMC-522513-0
KMC-522520-0
KMC-522521-0
Error text Description
Measurement amplifier: Timeout of
CAN messages from KMV 1
Error from force measurement amplifier
2
Measurement amplifier: Timeout of
CAN messages from KMV 2
Figure
Error from the residual moisture control unit
Timeout for the RMS control unit detected
Error from KMB module 1 KMC-522530-0
KMC-522531-0
KMC-522532-0
KMC-522533-0
Force measurement amplifier: Timeout of CAN messages from KMB 1
Error from KMB module 2
Measurement amplifier: Timeout of
CAN messages from KMB 2
Error from KMB module 4 KMC-522536-0
KMC-522537-0
KMC-522540-0
Measurement amplifier: Timeout of
CAN messages from KMB 4
Error from LMO module 1
KMC-522541-0 Measurement amplifier: Timeout of
CAN messages from LMO 3
KMC-522900-19 TIM status message timeout - CAN disturbance between control units
The TIM status message was not sent or received within the stipulated time.
KMC-522901-19 TIM authentication failed - CAN disturbance between control units
The TIM authentication has failed.
KMC-522902-13 TIM authentication certificate on the certificate blacklist - Values invalid, not plausible or outside the calibration
A TIM server certificate is on the AEF
TIM blacklist
Page 20
Error number
KMC-522903-13
KMC-522904-13
KMC-522905-13
KMC-522906-19
Error text
TIM server uses developer certificates
- Values invalid, not plausible or outside the calibration
Description
The TIM server uses developer certificates.
The TIM function speed is not available.
TIM function speed not available -
Values invalid, not plausible or outside the calibration
TIM function valve not available -
Values invalid, not plausible or outside the calibration
TIM function speed timeout - CAN disturbance between control units
The TIM function valve is not available.
The TIM function speed was aborted due to a time-out.
Figure
KMC-522907-19 TIM function valve timeout - CAN disturbance between control units
The TIM function valve has been terminated due to a timeout.
Page 21
Descarcă