Parameter list
>>>
2
Parameterliste_D2515020105300029_en [ } 30]
Round baler
Supplement to operating instructions 150001622_00_en 29
Key
R = Read access
RW = Read and write access
Parameter: Rundballenpresse
Software version: D2515020105400029_200
Control unit: KMC
Rights: Driver
Page 1
KMC-0070
KMC-0076
KMC-0077
KMC-0078
KMC-0082
KMC-0083
KMC-0090
KMC-0091
KMC-0111
KMC-0112
KMC-0113
KMC-0114
KMC-0115
KMC-0116
Parameter number
KMC-0057
Parameter name
Blade cassette cleaning function activation
KMC-0058 Frequency of the blade cassette cleaning function execution
Minimum
0
0
KMC-0059 Lower blade cassette blade group zero
0
0
0
0
10
1000
10
10
0
10
0
0
0
0
3000
Maximum
1
25
1
3
2
10000
10000
5000
2500
100
100
3
10000
10000
10000
100
100
Default
0
5
0
2500
25
25
1
1000
1000
1000
25
25
0
1
1000
0
3500
Unit digits ms ms ms digits digits ms ms mV mV
1/10 digits
1/10 digits
Description
Indicates whether the cleaning function is activated and/or installed
Specifies after how many tying starts the cleaning function should be carried out.
The automatic function is disabled when 0 is set.
Specifies whether the blades are swung out when the spare blade drawer is lowered with the hydraulic blade group control system
Page 2
KMC-0176
KMC-0177
KMC-0178
KMC-0179
KMC-0185
KMC-0189
KMC-0191
KMC-0197
KMC-0198
KMC-0202
Parameter number
KMC-0117
KMC-0118
KMC-0156
KMC-0163
KMC-0164
KMC-0165
KMC-0166
KMC-0168
KMC-0175
KMC-0204
KMC-0210
KMC-0214
KMC-0218
Parameter name
Baling system fixed chamber filling setpoint delay actuation
Baling system fixed chamber Alpine mode active
0
Minimum
10
65
0
0
750
10
0
65
0
0
0
0
10
90
0
750
750
750
0
750
0
10
0
1000
692
70
Default
25
20
50
80
0
100
50
100
1000
0
50
100
0
1000
1000
1000
0
10
1000
1
5000
2000
160
Maximum
100
100
100
210
250
210
250
250
4600
100
100
110
1
4600
2000
2000
90
90
10000
Unit digits cm
%
% mV digits
% cm
%
%
%
% mV mV mV digits
% ms mV digits cm
Description
How long must setpoint filling be exceeded until tying is actuated
Indicates whether
Alpine mode has been activated
KMC-0251
KMC-0252
KMC-0253
KMC-0260
KMC-0274
KMC-0275
KMC-0333
KMC-0355
KMC-0356
KMC-0384
Parameter number
KMC-0221
KMC-0223
KMC-0224
KMC-0225
KMC-0235
KMC-0236
KMC-0241
KMC-0248
KMC-0249
Parameter name
Wrapping arms fast speed work current
KMC-0431
KMC-0432
Central lubrication unit grease duration
Central lubrication unit grease pause
0
0
Minimum
60
750
0
60
60
90
0
0
750
0
1
90
0
100
1
1000
0
150
0
0
Page 3
KMC-0454
5
15
Default
135
100
0
10
1000
1000
600
135
135
100
0
10
1
1000
120
4000
0
300
70
75
60
60
Maximum
210
110
1
25
3000
3000
1000
210
210
110
1
25
10
3000
500
5000
150
450
100
100
Unit cm cm cm digits mm digits mV
1/10 °
1/10 °
% cm mV mV digits cm cm cm min min digits
Description
Fast working speed
(as a percentage of the maximum speed)
The lubrication duration
The pause time after which a new lubrication cycle may start
Page 4
KMC-0526
KMC-0527
KMC-0528
KMC-0533
KMC-0534
KMC-0546
KMC-0547
KMC-0549
KMC-0555
KMC-0556
KMC-0580
KMC-0601
KMC-0611
KMC-0612
KMC-0613
KMC-0654
KMC-0655
Parameter number
KMC-0455
KMC-0456
KMC-0501
KMC-0508
KMC-0509
KMC-0510
KMC-0511
KMC-0524
KMC-0525
Parameter name
0
0
0
0
0
0
0
0
0
0
0
0
90
30
10
0
30
Minimum
0
0
0
10
15
0
0
0
0
0
0
50
0
120
200
2000
0
50
100
0
0
100
50
20
5
100
Default
75
430
600
180
40
0
1000
850
1050
1
30000
100
1
120
210
15000
1
450
200
1
3
110
120
200
15
170
Maximum
100
1
10000
1200
1200
1200
1200
500
200
° bar ms mm digits digits
%
Unit digits digits digits digits
1/10 °
1/10 ° ms
1/10 °
1/10 °
1/10 °
1/10 ° cm digits
Description
Page 5
Parameter number
KMC-0656
KMC-0657
KMC-0671
KMC-0672
KMC-0673
KMC-0678
KMC-0679
KMC-0681
KMC-0682
KMC-0723
KMC-0724
KMC-0730
KMC-0737
KMC-0770
KMC-0771
KMC-0772
KMC-0773
KMC-0870
Parameter name
Bale lifter speedcontrolled slope mode active
0
0
0
0
Tying motion detection delay switching on
200
Minimum
0
0
0
10
10
0
0
0
0
0
0
750
0
KMC-0871 Tying motion detection delay switching off
200
Maximum
5000
200
2
10000
10000
100
100
1200
1200
120
10000
5300
1
1
1
10000
15000
20000
20000
0
0
500
8000
500
Default
1600
150
0
1000
0
25
25
1000
800
75
3000
5000
0
600
Unit mm mm/s ms ms digits digits
1/10 °
1/10 ° cm ms mV ms ms ms ms
Description
Has slope mode of the lifter been activated?
Delay time before checking for unintentional stopping of the feed rocker arm
Delay time before checking for unintentional movement of the feed rocker arm
Page 6
Parameter number
KMC-0872
Parameter name
Tying motion detection threshold value switching on
Minimum
0
KMC-0873 Tying motion detection threshold value switching off
0
Maximum
1000
1000
Default
20
50
Unit mV mV
Description
Threshold value of the voltage change in mV for the evaluation whether the feed rocker arm is moved
Threshold value of the voltage change in mV for the evaluation whether the feed rocker arm is stopped