EXPORT LIMIT
SETTINGS
Single and Three Phase Meter
STEPS FOR SETTING UP EXPORT LIMIT
USING A METER
*Make sure the inverter has a Meter input port.
STEP 1 : Press Enter on the inverter screen.
STEP 2 : Use Up/Down keys to go to advanced settings and press Enter.
STEP 3 : Press Down key twice and up key once, to type the password as 0010. Then press Enter.
STEP 4 : Use the up/down keys to scroll to
Grid ON/ Grid OFF. Then press Enter.
STEP 5 : Select the Grid OFF option and press
Enter. You will see the operation light turn
OFF.
STEP 6 : Use Up/Down keys to scroll to EPM settings/ Internal EPM/ Export Power Set, whichever is available on your screen. Then press Enter.
Enter
Advanced Settings
Enter
Up and Down Keys
Enter
Up and Down Keys
Grid ON/ Grid OFF
Enter
Operation light turned OFF
Grid OFF
Enter
EPM Settings
Enter
STEP 7: Go to Soft Hard Limit Set and press
Enter.
Step 8: Choose Soft Backflow Power and press
Enter. Then set the export limit using the
Up/Down keys and press Enter to save. For example: 5kw export limit will be +5000 W.
STEP 9 : Use Up/Down keys to find Mode Select.
Press Enter.
It will be OFF at first. Use Up/Down keys to select ‘ Meter in Grid ’. Press Enter to Save and you will see a message on the screen as
“DONE!”.
Step 10 : For 1phase inverters only , go to
Meter Select, choose 1Ph.
Then select appropriate meter model name that you have installed.
STEP 11 : Now turn the Grid ON in Advanced
Settings.
(Go to Advanced Settings again by pressing ESC thrice < Set password 0010 < Go to Grid
ON/Grid OFF < Select Grid ON < Press Enter).
STEP 12: Press ESC to exit to the main screen.
The status displayed will be LYMBYEPM, which indicates you have successfully set up the export limit.
Note - Do not Turn OFF failsafe alarm. If you have any Failsafe alarm, it indicates issue with export setup and connections. Check the connections and make sure inverter is meter compliant .