Velleman DVM8852 Benutzerhandbuch
PDF
Dokument
Werbung
Werbung
4 9 14 19 24 DVM8852 Figure 3 Figure 1 00 (04/11/2008) 2 Velleman® DVM8852 3 Velleman® DVM8852 User manual 1. Introduction To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer. Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems. 2. Safety Instructions Keep the device away from children and unauthorised users. Keep the sound level meter away from rain, moisture, splashing and dripping liquids. Protected the meter against extreme heat and dust. Do not use in area’s where altitude > 2,000m. • • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems. Note that damage caused by user modifications to the device is not covered by the warranty. Protect this device from shocks and abuse. Avoid brute force when operating the device. Familiarise yourself with the functions of the device before actually using it. All modifications of the device are forbidden for safety reasons. Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty. There are no user-serviceable parts inside. Refer to an authorized dealer for spare parts. 4. Features • • • • • • • • • • • • • • device complies with IEC61672-1 Class2 for sound level meters with Windows software and MAC / Linux USB drivers 32,700 records data logger bar graph indication max/min function over and under range display auto ranging: 30 ~ 130dB clock display resolution: 0.1dB level range display AC/DC signal output auto power off fast & slow response AC/DC signal output for connection to analyser or X-Y recorder 00 (04/11/2008) 4 Velleman® DVM8852 5. Overview General: refer to the Figure 1 and Figure 2 on page 2 of this manual. A windscreen J hold button B LCD display K backlight button C record start/stop button L external 9VDC jack D setup button M USB mini-B connector E mode select button N AC/DC output jack F signal weighing select button O pick-up element G max/min capture button P tripod mounting hole H range/level select button Q battery cover I power on/off button LCD-display: refer to Figure 3 on page 2 of this manual. 1 UNDER the current measurement is below the selected range 2 OVER the current measurement is above the selected range 3 MAX the maximum noise level is being measured 4 MIN the minimum noise level is being measured 5 FAST fast measurement mode, measurement every 125ms 6 SLOW slow measurement mode, measurement every 1s 7 88 range indicator, lower limit 8 188 range indicator, lower limit 9 bar graph 10 DATE scale depends on selected range (low, medium, high, auto) 11 18:88:88 12 TIME indicates time display 13 188.8 measured sound level only displayed during setup shows time during normal operation, shows set-up codes during set-up 14 auto-power off mode enabled 15 low battery indication, replace battery 16 REC datalogger enabled, data is being stored 17 FULL datalogger memory is full, connect meter to PC to save/clear memory 18 dBA A-weighted mode 19 dBC C-weighted mode 20 AUTO automatic range selection 21 HOLD hold mode, displayed value frozen 6. Operation General • Slide the windscreen [A] over the pick-up element [O] to avoid erroneous measurements due to strong winds. • Switch the sound meter on by pressing the power on/off button [I]. • Select the sound pressure range with the range/level select button [H]. Ranges are indicated on the display [7], [8] and [20]. The bar graph [9] scale depends on the selected range. [7] • [8] range 30 80 low 50 100 medium 80 130 high 30 130 auto range When the UNDER [1] or OVER [2] indication appears, the measurement is outside the selected range. Select an appropriate range. 00 (04/11/2008) 5 Velleman® DVM8852 • The meter has two operational modes, fast or slow. In fast mode, sound is sampled every 125ms; in slow mode every second. Select fast or slow mode with the mode select button [E]. Selected mode is indicated in the display, [5] or [6]. Note that the display itself is updated 2 times per second. • There are two weighing schemes available on the meter: A-weighted (dBA) and C-weighted (dBC): dBA: sound pressure adjusted towards the frequency range of human hearing dBC: sound pressure adjusted towards the low frequency end of the spectrum Select the desired scheme with the signal weighing select button [F], the scheme is indicated on the display [18] or [19]. • Press the hold button [J] to freeze the current measurement on the display. Hold mode is indicated on the display [21]. Press the hold button [J] again to exit hold mode. • Press the max/min capture button [G] to continuously display the maximum measured value, display indicates MAX [3]. Press the max/min capture button [G] again to continuously display the minimum measured value, display indicates MIN [4]. Pressing the max/min capture button [G] again will show the current noise pressure level again. • Press the backlight button [K] to switch the backlight on and off. • The auto-power off mode indication [14] is shown when auto-power off is enabled. The meter switches off after ±15 minutes of user inactivity. To disable the auto-power off function, press the setup button [D]. • To switch off the meter, press and hold the power on/off button [I] for about 3 seconds (display shows countdown). • The meter can be used handheld or mounted on the included tripod. Screw the tripod into the mounting hole [P] on the back of the meter. Note: the AC/DC output jack can be used to connect other devices e.g. frequency analyzer (not incl.), plotter (not incl.) … X AC output Y DC output Z Ground voltage: 1Vrms/range step impedance: 100Ω voltage: 10mV/dB impedance: 1kΩ Time/date setting • If the meter is on, switch it off first. • Press and hold the setup button [D] while switching on the meter with the power on/off button [I]. Release the setup button [D] when TIME [12] is displayed. The display now shows the date. • Pressing the setup button [D] to enter the setup menu. Press the setup button [D] to save the setting and go to the next setup entry. Press the hold button [J] at any time to save the setting and exit setup mode. Press # Display 1 minutes TIME nn set the minutes by pressing the range/level select button [H] 2 hour TIME h-A or h-P set the hour by pressing the range/level select button [H] A=ante meridiem (before noon), P=post meridiem (after noon) 3 DATE –d- day set the day of the month by pressing the range/level select button [H] 4 DATE –Hmonth set the month by pressing the range/level select button [H] 5 DATE –Y- year set the year by pressing the range/level select button [H] 6 rSt press the hold button [J] to reset date and time to factory default Note: the day is not shown on the display during normal operation. It can only be shown by going into setup mode Data logger function • During measurement, press the record start/stop button [C] to start recording the measurement. Press again to stop recording. Recordings can be transferred to a computer (see §7 Analysis). • To clear the memory, switch off the meter first. Press and hold the record start/stop button [C] while switching the meter back on. Release the record start/stop button [C] when the word CLR appears on the display. Warning: all recorded data in the meter is lost. Consider uploading the memory content to a computer prior to clearing the memory. 00 (04/11/2008) 6 Velleman® DVM8852 7. Analysis • The meter can store 32,700 readings. To analyse the readings, the included software must be installed. Software setup • Insert the included CD-ROM into a personal computer. Open the CD directory and double click on the file named setup.exe to start the installation. Follow the instructions on the screen of your computer. • Connect the USB port [M] of the meter with a free USB port of the computer using the included USB cable. • Switch on the meter with the power on/off button [I]. • Press on the setup button [D] to start data transmission. The auto-power off icon [14] is no longer displayed. • When the computer doesn’t recognize the USB device, copy the CP2101WIN directory from the CD to a local directory and let the computer look for the drivers on the local directory. Data analysis • • • • • • • • • • • • Locate the 8852.exe icon ( ) and double click it to start the software. Select the right COM port in the ComPort(C) menu. The COM port depends on the setup of the computer and the used USB port. When the right port is selected, connection is established immediately. Refer to the Figure 4 on page 3 of this manual for a screen shot. Use the Real Time(R) menu to run or stop real time sound monitoring, set up or clear the graph. Details are shown above the graph. Real-time mode must be stopped to set the sampling rate. Note that this is not the sampling rate of the meter, but the rate with which the software reads the meter. Zoom in on the graph by selecting an area with left click, drag and release. To go back to full screen graph, click on the UnDo Zoom button. When in zoom mode, click on the Graph(G) menu and select Histogram. Click anywhere in the graph to change the appearance to a histogram. Go to the Graph(G) menu, select Line and click anywhere in the graph to change the appearance back to line. Also in zoom mode, double click left mouse button on a point of the graph will set a green mark line. Double click left mouse button again to set a second mark line (blue). Data between the two mark lines is analyzed (e.g. max. value, min. value, average…) and shown below the graph. To remove the mark lines, click on the right mouse button or double click left mouse button on a new point in the graph. To save the real-time data, stop real-time monitoring and start it again. At this point, the software will ask to save the previous graph data. Data is saved as a text file. To analyze previously recorded meter data, select the DataLogger(D) menu. Note that this will not work when the meter is in record mode. A new screen opens; refer to Figure 5 on page 3 of this manual for a screen shot. The data is copied from the meter to the software memory and deleted from the meters’ memory. To save the data on the computer, use the Save Data(S) menu. If not, when closing the application the data will be lost. Double click left mouse button on a file to see the data. The graph also has the zoom and mark lines functions. It is possible to recall previously saved records with the Import Data (I) menu. To print the graph, use the Print Data (P) menu. 8. Battery replacement • To replace the battery, switch off the meter first. • Open the battery cover [Q]. Push gently on the mark ( ) and slide the cover ±1cm downwards and lift. • Remove the old battery and insert a new 9V battery. Respect the polarity. • Place the cover on the back of the device and slide upwards. Make sure all keys are in place and the battery cover is closed completely. WARNING: A malfunction may occur if the power is on when the battery is replaced. Dispose of batteries in accordance with local regulations. Keep the battery away from children. 00 (04/11/2008) 7 Velleman® DVM8852 9. Technical specifications level range Lo 30-80dB Med 50-100dB Hi 80-130dB accuracy ± 1.4dB (ref 94dB @ 1kHz) frequency weighting A, C time weighting fast (125ms), slow (1s) dynamic range 50dB frequency range 31.5Hz to 8kHz microphone auxiliary outputs AC=1Vrms and DC=10mV/dB outputs power supply 9V battery (incl.) battery life ±30 hours (with alkaline battery) dimensions 278 x 76 x 50mm ±350g auto power off ±15min operation temperature 0-40°C operation humidity <90% included accessories instruction manual, tripod, battery, screwdriver, windscreen, Windows software, USB cable , 9V battery Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulted from (incorrect) use of this device. For more info concerning this product, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice. 00 (04/11/2008) 8 Velleman® DVM8852 00 (04/11/2008) 9 Velleman® DVM8852 J holdtoets L externe 9 VDC-aansluiting M mini USB-aansluiting E modustoets N AC/DC-uitgang G max-mintoets P aansluiting statief Q batterijvak UNDER 2 OVER 3 MAX meting van de maximale geluidsdruk 4 MIN meting van de minimale geluidsdruk 5 FAST snelle meting (elke 125 ms) 6 SLOW trage meting (elke 1 s) 7 88 bereikaanduiding, lage drempel 8 188 bereikaanduiding, hoge drempel 9 bargraph 10 DATE 11 18:88:88 12 TIME 13 188.8 gemeten waarde van de geluidsdruk 14 automatische uitschakeling ingeschakeld 15 16 REC 17 FULL geheugen datalogger is vol, sluit meter aan op pc om data te bewaren/wissen 18 dBA A-weging 19 dBC 20 AUTO 21 HOLD • [7] [8] 30 80 laag 50 100 80 130 hoog 00 (04/11/2008) 10 Velleman® DVM8852 • AC-uitgang Y DC-uitgang Z massa spanning: 1 V rms/stap impedantie: 100 Ω spanning: 10 mV/dB impedantie: 1 kΩ display 1 minuten TIME nn 2 uur TIME h-A of h-P 3 DATE -d- dag 4 DATE -H- maand 5 DATE -Y- jaar 6 rSt houd de holdtoets [J] ingedrukt om de fabrieksinstellingen opnieuw in te stellen 11 Velleman® DVM8852 7. Analyse • 00 (04/11/2008) 12 Velleman® DVM8852 9. Technische specificaties meetbereik Lo 30 ~ 80 dB Med 50 ~ 100 dB Hi 80 ~ 130 dB nauwkeurigheid ± 1,4 dB (ref 94 dB @ 1 kHz) frequentieweging A, C snel (125 ms), traag (1 s) 50 dB 31,5 Hz ~ 8 kHz microfoon voeding ± 30 uur (met alkalinebatterij) afmetingen 278 x 76 x 50 mm ± 350 g automatische uitschakeling ± 15 min 0 ~ 40°C < 90 % handleiding, statief, batterij, schroevendraaier, windscherm, Windows®-software, USB-kabel 00 (04/11/2008) 13 Velleman® DVM8852 00 (04/11/2008) 14 Velleman® DVM8852 J touche de gel d’affichage C marche/arrêt enregistrement O microphone G touche max/min Q compartiment de la pile UNDER 2 OVER 3 MAX 4 MIN 5 FAST 6 SLOW 7 88 8 188 9 10 DATE 11 18:88:88 12 TIME 13 188.8 14 15 16 REC 17 FULL 18 dBA 19 dBC 20 AUTO 21 HOLD mode de gel d’affichage • [7] [8] gamme 30 80 bas 50 100 moyen 80 130 haut 00 (04/11/2008) 15 Velleman® DVM8852 • Y Z masse Enfoncer # 1 minutes TIME nn 2 heure TIME h-A ou h-P 3 4 5 rSt 00 (04/11/2008) 16 Velleman® DVM8852 7. Analyse • • • • • • • • • • • • 00 (04/11/2008) 17 Velleman® DVM8852 ± 1,4 dB (réf. 94 dB @ 1 kHz) A, C 50 dB 31,5 Hz ~ 8 kHz microphone alimentation pile 9 V (incl.) dimensions 278 x 76 x 50 mm poids ± 350 g ± 15 min 0 ~ 40°C < 90 % 00 (04/11/2008) 18 Velleman® DVM8852 00 (04/11/2008) 19 Velleman® DVM8852 J B pantalla LCD D tecla de ajuste N salida CA/CC O micrófono G tecla máx./mín. I OVER 3 MAX 4 MIN 5 FAST 6 SLOW 7 88 8 188 9 10 DATE 11 18:88:88 12 TIME 13 188.8 valor del nivel sonoro 14 15 16 REC 17 FULL 18 dBA 19 dBC 20 AUTO 21 HOLD 00 (04/11/2008) [7] [8] rango 30 80 bajo 50 100 medio 80 130 Velleman® salida CA Y salida CC Z masa Display 1 minutos TIME nn 2 hora TIME h-A o h-P 3 4 DATE -H- mes 5 rSt 00 (04/11/2008) 21 Velleman® 7. Análisis • • • • • • • • • • • • 00 (04/11/2008) 22 Velleman® DVM8852 Lo 30 ~ 80 dB Med 50 ~ 100 dB Hi 80 ~ 130 dB ± 1,4 dB (ref. 94 dB @ 1 kHz) A, C rango dinámico 50 dB 31,5 Hz ~ 8 kHz pila de 9V (incl.) dimensiones 278 x 76 x 50 mm peso ± 350 g ± 15 min. 0 ~ 40°C humedad < 90 % 00 (04/11/2008) 23 Velleman® DVM8852 00 (04/11/2008) 24 Velleman® DVM8852 J B LCD-Display E Modustaste N AC/DC-Ausgang O Mikrofon G MAX/MIN-Taste I Hold-Taste UNDER 2 OVER 3 MAX 4 MIN 5 FAST 6 SLOW langsame Messung (jede 1 s) 7 88 8 188 9 Bargraph 10 DATE 11 18:88:88 12 TIME 13 188.8 14 15 16 REC 17 FULL 18 dBA 19 dBC 20 AUTO 21 HOLD 00 (04/11/2008) [7] [8] 30 80 niedrig 50 100 80 130 hoch 30 130 Velleman® DVM8852 • ACAusgang DCAusgang Masse Display 1 Minuten TIME nn 2 3 DATE -d- Tag 4 DATE -H- Monat 5 rSt 6 00 (04/11/2008) 26 Velleman® 7. Analyse • 00 (04/11/2008) 27 Velleman® DVM8852 Lo 30 ~ 80 dB Med 50 ~ 100 dB Hi 80 ~ 130 dB ± 1,4 dB (ref 94 dB @ 1 kHz) A, C schnell (125ms), langsam (1s) 50 dB 31,5 Hz ~ 8 kHz Mikrofon Elektret-Kondensatormikrofon (12.7mm) Hilfsaugänge Stromversorgung 278 x 76 x 50 mm ± 350 g ± 15 Min. Betriebstemperatur 0 ~ 40°C < 90 % 00 (04/11/2008) 28 Velleman®">
/
Herunterladen
Nur eine freundliche Erinnerung. Sie können das Dokument direkt hier ansehen. Aber was am wichtigsten ist, unsere KI hat es bereits gelesen. Sie kann komplexe Dinge einfach erklären, Ihre Fragen in jeder Sprache beantworten und Ihnen helfen, auch in den längsten oder kompliziertesten Dokumenten schnell zu navigieren.
Werbung