System Overview. Bosch Solution 2000, SOLUTION 3000
Add to My manuals150 Pages
Bosch Solution 2000 is a versatile security system that provides comprehensive protection for your home or business. With its advanced features and user-friendly interface, the Bosch Solution 2000 is the ideal choice for those seeking a reliable and effective security solution.
advertisement
Control Panel
2
2.1
System Overview
Product Matrix
System Overview | en
11
Figure 2.1: Product Matrix 2017
2.2
Configuration and Parts
This section lists each control panel's capacities and a parts list.
2.2.1
Control panel capacities
Features
Number of users
Number of zones
Number of areas/partitions
Number of on-board outputs
Number of codepads
Number of B308 Octo-output modules
Number of B426 IP communicators
Number of B442 or B450 GPRS communicators
Number of WE800EV2 receivers
2
2
1
4
4
2
Solution 2000
32
4+4 (ZD)
2
2
2
1
4
4
2
Solution 3000
32
8+8 (ZD)
2
Bosch Security Systems, Inc.
Installation Guide 2017.10 | 03 | F.01U.298.026
12
en | System Overview Control Panel
Features
Number of RADION receivers
Number of RADION repeaters
2.2.2
2.2.3
Solution 2000
0
0
Solution 3000
1
8
Parts list
Control panels ship assembled from the factory with the following parts:
Literature
– Control Panels (Solution 2000 / Solution 3000 ) Quick Reference Guide
– Control Panels (Solution 2000 / Solution 3000 ) User Guide
HW pack
– EOL resistors
– Battery wires
– PSTN lead
– Screws
Assembly
– PC board
Order separately
Order the accessories listed below to aid in the installation of your control panel. If you ordered your control panel in a kit, you might already have these parts.
Accessory Type
Codepads
Keyfobs
Octo-output modules
Receivers
Repeaters
Detectors
Solution 2000
Touchscreen, IUI-SOL-
ICON, IUI-SOL-TEXT
HCT-4
B308
WE800EV2
Wired detectors
Software A-Link Plus
Ethernet communication modules B426
GPRS communication modules
Transformer
Other accessories:
Keyswitches
Battery
Siren
Strobe
RJ11 PSTN terminal
Control Panel Enclosure
B450 with B442 or B443
TF008-B
Solution 3000
Touchscreen, IUI-SOL-
ICON, IUI-SOL-TEXT
HCT-4, RFKF-TB/RFKF-FB
B308
WE800EV2, B810
RFRP
Wired detectors, RADION wireless detectors
A-Link Plus
B426
B450 with B442 or B443
TF008-B
2017.10 | 03 | F.01U.298.026
Installation Guide Bosch Security Systems, Inc.
advertisement
Key Features
- Supports up to 8 zones for comprehensive coverage
- Stay and Away arming modes for customizable protection
- Panic, fire, and medical alarms for emergency situations
- Remote arming and disarming via telephone or A-Link Plus Software
- Event Memory Recall Mode for easy review of system activity
- Fault Analysis Mode for quick troubleshooting
Related manuals
Frequently Answers and Questions
How many zones does the Bosch Solution 2000 support?
Does the Bosch Solution 2000 have a panic alarm?
Can the Bosch Solution 2000 be armed and disarmed remotely?
How do I reset the Bosch Solution 2000 to factory default settings?
advertisement
Table of contents
- 1 Title Page
- 3 Table of Contents
- 9 Introduction
- 9 About documentation
- 9 Bosch Security Systems, Inc. product manufacturing dates
- 11 System Overview
- 11 Product Matrix
- 11 Configuration and Parts
- 11 Control panel capacities
- 12 Parts list
- 12 Order separately
- 13 Installation workflow
- 14 Accessories
- 14 Codepads
- 16 Installer Menu
- 18 WE800EV2 receiver
- 19 HCT-4 keyfob
- 19 RADION receiver B810
- 19 RADION keyfobs
- 20 RADION repeater
- 20 RADION detectors
- 20 B308 Octo-output Module
- 21 B426/B426-M Conettix Ethernet Communication Modules
- 21 B450/B450-M Conettix Plug-in Communicator Interfaces
- 22 A-Link Plus Software
- 23 Remote Security Control
- 23 Remote Security Control Plus
- 23 Keyswitches
- 24 TF008 Plug Pack (TF008-B)
- 24 Install the transformer
- 24 DLA
- 25 Configuration
- 25 Installer Commands
- 25 Command 958 - Exit from Installer's Programming Mode without saving changes
- 25 Command 959 - Test IUI-SOL-ADAPTER
- 26 Command 960 - Save and exit from Installer's Programming Mode
- 26 Command 961 - Reset the Control Panel to Factory Default Settings
- 26 Command 962 - Copy the Control Panel Memory to IUI-SOL-ADAPTER
- 27 Command 963 - Copy IUI-SOL-ADAPTER data to the Control Panel
- 27 Command 965 - Set up Domestic Dialing Format
- 28 Command 966 - Enable/Disable the Automatic Stepping of Locations
- 28 Command 999 - Display the Control Panel Firmware Version Number
- 29 Disable Factory Defaults
- 31 System Operations
- 31 Arming the system in AWAY Mode
- 31 Disarming the system from AWAY Mode
- 32 Arming the System in STAY Mode 1
- 33 Disarming the system from STAY Mode 1
- 33 Arming the system from STAY Mode 2
- 34 Disarming the system from STAY Mode 2
- 34 Codepad duress alarm
- 34 Codepad panic alarm
- 35 Codepad fire alarm
- 35 Codepad medical alarm
- 35 Isolating zones
- 35 Standard isolating
- 36 Code to isolate
- 36 Fault analysis mode
- 37 Fault descriptions
- 39 Inquire cloud status
- 41 System Functions
- 41 Installer Code Functions
- 41 Add or Delete RF Wireless Devices
- 42 Add/Delete RF Repeater
- 43 Add/Delete RF Keyfob
- 43 Using an ICON codepad
- 44 Using an Alphanumeric codepad
- 45 Set the Number of Days until the First Test Report
- 45 Change Domestic Phone Numbers
- 46 Change Telco Arm/Disarm Sequence
- 47 Setting STAY Mode 2 Bypass Zones
- 48 Turning Report Monitor Mode On and Off
- 49 Walk Test Mode
- 49 Event Memory Recall Mode
- 50 AWAY/STAY 1 Arm/Disarm
- 51 Master Code Functions
- 51 Arm or Disarm both Areas at the Same Time
- 51 Arm or Disarm Single Area
- 52 Changing and Deleting User Codes
- 53 Adding Remote Radio User Codes
- 53 Deleting User/Radio Codes
- 54 Change Domestic Phone Numbers
- 54 Change Telco Arm/Disarm Sequence
- 54 Setting STAY Mode 2 Bypass Zone
- 54 Turning Outputs On and Off
- 55 Setting the Date and Time
- 55 Walk Test Mode
- 55 Event Memory Recall Mode
- 55 System reset
- 55 User Code Functions
- 55 Arm or Disarm both Areas at the Same Time
- 56 Arm or Disarm Single Area
- 56 Hold-Down Functions
- 56 Arm the System in AWAY Mode
- 56 Arm the System in STAY Mode 1
- 56 Arm the System in STAY Mode 2
- 57 Horn Speaker Test
- 57 Bell Test
- 57 Strobe Test
- 57 Turning Day Alarm On and Off
- 57 Fault Analysis Mode
- 57 Initiate a Modem Call
- 58 Reset Latching Outputs
- 58 Change the Codepad Buzzer Tone
- 58 Send Test Report
- 59 RF Keyfob Operations
- 59 Indications from RF Keyfob Operations
- 59 Remote Radio User Code Priority Levels
- 60 Remote Arming by Telephone
- 61 A-Link Plus Application
- 61 Modem Connection
- 61 Remote Connection with Customer Control
- 61 Remote Connection without Callback Verification
- 62 Remote Connection with Callback Verification
- 62 Answering Machine Bypass Connection
- 62 Network Connection
- 63 Direct Connection
- 63 Options
- 64 Configuring for email
- 64 Configure through B426/B426-M
- 66 Configure through B450/B450-M
- 68 Communication Information
- 69 Primary Telephone Number for Receivers
- 69 Secondary Telephone Number for Receivers
- 69 Transmission Format for Receivers
- 70 Subscriber ID Number for Receivers
- 70 IP Items for Receivers
- 71 Conettix Items for Receivers
- 72 External Network Modules
- 73 Network Module Cloud Connection
- 73 Password for A-Link Connection
- 73 DTMF Timing Compensation
- 73 Country Codes
- 73 Telco Arming Sequence
- 74 Telco Disarming Sequence
- 75 Call Back Telephone Number
- 75 Ring Count
- 76 Telephone Line Fail Options
- 77 Communication Options 1
- 77 Communication Options 2
- 78 Communication Options 3
- 79 A-Link Plus Options
- 79 Domestic Dialing
- 79 Domestic Dialing Funtion
- 80 Setting Up and Programming Domestic Reporting
- 81 Reporting Formats
- 81 Contact ID Format
- 82 SIA Format
- 82 System Reporting List
- 87 Access
- 87 Installer Code
- 87 User Codes
- 89 User Code Priority
- 91 Zone Information
- 91 Day Alarm Information
- 91 Day Alarm Resetting
- 91 Day Alarm Latching
- 91 Day Alarm Operation
- 92 EOL Resistor Value
- 93 Zone Programming
- 93 Zone Defaults
- 97 Zone Types
- 99 Zone Pulse Count
- 100 Zone Pulse Count Time
- 100 Zone Options 1
- 101 Zone Options 2
- 102 Zone Report Options
- 103 Keyswitch Zone Options
- 104 Zone Source
- 104 Swinger Shutdown Count for Siren
- 105 Swinger Shutdown Count for Report
- 106 STAY Mode 2 Automatically Bypass Zones
- 106 Zone Status Reporting Options
- 107 RF Information
- 107 RF Supervision Time
- 107 Anti-Jamming Sensitivity
- 108 RF Receiver
- 108 RF Options
- 108 RFID
- 109 RF Keyfob RFID
- 109 RF Device RFID
- 110 RF Reapter RFID
- 111 System Reporting Information
- 111 Arm/Disarm Reporting Options
- 111 Codepad Reporting Options
- 111 Access Denied
- 112 System Status Reporting Options
- 112 Test Reporting Time
- 113 Test Reporting Options
- 113 Reports
- 113 Zone Tamper Report
- 113 Walk Test Report
- 113 Bypass Report
- 113 Trouble Report
- 114 Sensor Watch Report
- 114 Alarm Restore Code
- 114 RF Receiver Trouble Report
- 114 RF Receiver Trouble Restore Report
- 114 RF Low Battery Report
- 114 Arm/Disarm Reports
- 115 Codepad Duress Report
- 115 Codepad Panic Report
- 115 Codepad Fire Report
- 115 Codepad Medical Report
- 115 AUX Power Supply Fail Report
- 115 AUX Power Supply Fail Restore Report
- 116 AC Fail Report
- 116 AC Fail Restore Report
- 116 Low Battery Report
- 116 Low Battery Restore Report
- 117 Programmable Outputs
- 117 Output Programming
- 123 B228 Output Mode
- 123 Output Event Types
- 130 Output Polarity
- 132 Output Timing
- 132 Pulsing Polarities
- 132 One-Shot Polarities
- 134 System Event Timers
- 134 Programming Entry/Exit Times
- 134 Entry Time 1
- 134 Entry Time 2
- 134 Exit Time
- 135 Entry Guard Time for STAY Mode
- 135 Delay Alarm Reporting Time
- 135 Sensor Watch Time
- 136 Codepad Lockout Time
- 136 Siren Run Time
- 136 Siren Sound Rate
- 136 Auto Arming Pre-Alert Time
- 137 Auto Arming Time
- 137 Auto Disarming Time
- 137 Kiss-Off Wait Time
- 137 Speaker Beep Volume
- 138 System and Consumer Options
- 138 System Options 1
- 139 System Options 2
- 139 System Options 3
- 140 System Options 4
- 141 System Option 5
- 141 Consumer Options 1
- 142 Consumer Options 2
- 143 Consumer Options 3
- 144 Partitioning
- 144 Programming
- 144 Partitioning Options 1
- 144 Partitioning Options 2
- 145 Partition Allocations
- 145 Zone Area Assignments
- 146 Codepad assignment
- 146 User code area assignments
- 148 Text Information
- 149 Back Page