Appendix I GATM wiring chart 221
Appendix I
GATM wiring chart
Analog telephone lines connect to the GATM4 or GATM8 through the RJ-21 connector on the
front of the media bay module (MBM). See the figure GATM RJ-21 connector on page 221.
Figure 95 GATM RJ-21 connector
GATM
RJ-21 connector RJ-21 pin out
The table
GATM4 RJ-21 connector wiring on page 221 lists the wiring details for the RJ-21
connector on the GATM4.
Table 46 GATM4 RJ-21 connector wiring (Sheet 1 of 2)
Line
Default line numbers on
Expansion port 1
Default line numbers on
Expansion port 2
1
2
—
—
3
4
—
.
.
.
Pin
.
.
.
Connection
26 Tip
1 Ring
27 Tip
2 Ring
28 No connection
3 No connection
29 No connection
4 No connection
30 Tip
5 Ring
31 Tip
6 Ring
32 No connection
7 No connection
.
.
.
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
.
.
.
065
066
—
—
067
068
—
.
.
.
095
096
—
—
097
098
—
.
.
.
Installation and Maintenance Guide
222 Appendix I GATM wiring chart
Table 46 GATM4 RJ-21 connector wiring (Sheet 2 of 2)
Line Pin Connection Wire color
Default line numbers on
Expansion port 1
Default line numbers on
Expansion port 2
—
Aux
49 No connection
24 No connection
50 Tip
25 Ring
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
—
—
—
—
Note: The AUX port supports full data speeds. When the line is in use by an analog device, the icon is lit on the phone to indicate it is in use. If you try to seize the line using the phone, the display shows “in use”. Also, if a power failure occurs, an analog set on line 1 activates (powered by the CO).
The table
GATM8 RJ-21 connector wiring on page 222 lists the wiring details for the RJ-21
connector on the GATM8.
Table 47 GATM8 RJ-21 connector wiring (Sheet 1 of 2)
Line
Default line numbers on
Expansion port 1
Default line numbers on
Expansion port 2
1
2
—
—
3
4
—
—
5
6
—
—
Pin Connection Wire color
26 Tip
1 Ring
27 Tip
2 Ring
White-Blue
Blue-White
White-Orange
Orange-White
28 No connection White-Green
3 No connection Green-White
29 No connection White-Brown
4 No connection Brown-White
30 Tip
5 Ring
31 Tip
6 Ring
White-Slate
Slate-White
Red-Blue
Blue-Red
32 No connection Red-Orange
7 No connection Orange-Red
33 No connection Red-Green
8 No connection Green-Red
34 Tip
9 Ring
Red-Brown
Brown-Red
35 Tip Red-Slate
10 Ring Slate-Red
36 No connection Black-Blue
11 No connection Blue-Black
37 No connection Black-Orange
12 No connection Orange-Black
065
066
—
—
067
068
—
—
073
074
—
—
095
096
—
—
097
098
—
—
103
104
—
—
NN40020-302
Appendix I GATM wiring chart 223
Table 47 GATM8 RJ-21 connector wiring (Sheet 2 of 2)
Line Pin Connection Wire color
Default line numbers on
Expansion port 1
Default line numbers on
Expansion port 2
7
8
—
.
.
.
38 Tip
13 Ring
Black-Green
Green-Black
39 Tip Black-Brown
14 Ring Brown-Black
40 No connection Black-Slate
15 No connection Slate-Black
.
.
.
.
.
.
075
076
—
105
106
—
.
.
.
.
.
.
.
.
.
—
49 No connection Violet-Brown
24 No connection Brown-Violet
— —
Aux
(see
Note)
50
25
Tip
Ring
Violet-Slate
Slate-Violet
— —
Note: The AUX port supports full data speeds. When the line is in use by an analog device, the icon is lit on the phone to indicate it is in use. If you try to seize the line using the phone, the display shows “in use”. Also, if a power failure occurs, an analog set on line 1 activates (powered by the CO).
Installation and Maintenance Guide
224 Appendix I GATM wiring chart
NN40020-302
advertisement
Related manuals
advertisement
Table of contents
- 5 Task List
- 9 Contents
- 17 Regulatory information
- 17 North American regulatory information
- 17 Canadian Notice
- 18 Federal Communications Commission (FCC) Notice
- 18 Ringer Equivalence Number (REN)
- 18 EMI/EMC (FCC Part 15)
- 19 Important safety instructions
- 20 Safety
- 21 Enhanced 911 configuration
- 21 Radio-frequency interference
- 21 Telecommunication registration
- 22 International regulatory information
- 23 Safety
- 23 Additional safety information
- 24 ITU standardization compliance
- 25 Getting started
- 25 About this guide
- 25 Audience
- 25 Acronyms
- 27 Symbols and text conventions
- 29 Related publications
- 30 How to get help
- 33 Introducing the BCM50 hardware
- 33 Main units
- 38 BCM50 Expansion unit and media bay modules
- 40 Media bay modules
- 48 BCM50 hardware
- 48 Rack-mount shelf
- 49 Patch panel
- 49 Wall-mount bracket
- 50 Power supply mounting bracket
- 50 Wiring field card
- 50 BCM50 components
- 51 Power supply
- 51 Power supply adapter cord (international users)
- 51 Uninterruptable power supply
- 52 Hard disk
- 53 Cooling fan
- 54 RJ-21 telephony connector
- 55 Router card
- 55 Field-replaceable units
- 56 Telephones and adapters
- 59 Accessories
- 61 Viewing the BCM50 system LEDs
- 61 System status LEDs
- 62 LAN port LEDs
- 64 ADSL router LEDs (BCM50a and BCM50ba only)
- 65 Ethernet router LEDs (BCM50e and BCM50be only)
- 66 BRI port LEDs on main unit (BRI series only)
- 66 Media bay module LEDs (expansion units only)
- 67 DTM LEDs
- 68 BRIM LEDs
- 69 Determining DHCP server configuration and IP address
- 69 BCM50 and BCM50b main units (no integrated router)
- 69 If an external DHCP server is not present
- 70 If an external DHCP server is present
- 70 BCM50a, BCM50ba, BCM50e, and BCM50be main units (with integrated router)
- 73 Installing the BCM50 system
- 77 Checking the installation prerequisites
- 77 Environmental requirements
- 77 Electrical requirements
- 78 Site telephony wiring requirements
- 78 Digital loop
- 78 Analog loop
- 79 System equipment, supplies, and tools
- 79 Basic hardware
- 79 Optional equipment
- 79 Other hardware and tools
- 81 Installing the main unit
- 82 Unpacking the main unit
- 82 Installing the BCM50 unit in an equipment rack
- 83 Installing the BCM50 unit on the rack-mount shelf
- 86 Installing the BCM50 unit on the wall
- 90 Installing the wiring field card (optional)
- 91 Installing the BCM50 unit on a desktop or shelf
- 92 Next step
- 93 Installing an expansion unit
- 94 Unpacking the expansion unit
- 94 Verifying the media bay module switch settings
- 97 Installing a media bay module in an expansion unit
- 97 Installing the expansion unit
- 98 Next step
- 99 Connecting the cables to the BCM50 system
- 100 Connecting the expansion unit
- 102 Connecting the power supply
- 104 Connecting the lines and extensions
- 105 Wiring warnings
- 106 Connecting lines and extensions to the RJ-21 telephony connector
- 107 Connecting telephone lines to the expansion units
- 108 Connecting extensions to the expansion units
- 109 Connecting the auxiliary equipment
- 110 Connecting an auxiliary ringer
- 110 Connecting an external paging system
- 111 Connecting an external music source
- 114 Next step
- 115 Installing telephones and peripherals
- 115 System telephones
- 115 Analog terminal adapter 2
- 116 Central Answering Position (CAP/eCAP)
- 116 Installing an emergency telephone
- 117 Installing IP phones
- 117 Installing T7406 cordless systems
- 119 Installing the analog terminal adapter
- 119 Configuration overview
- 119 Analog telephone
- 120 Analog data device
- 120 Installing the ATA2
- 120 Connecting the ATA2
- 121 Mounting the ATA2
- 122 Test insertion loss measurement
- 123 Configuring the ATA2
- 125 Configuring the BCM50 system
- 126 Initial parameters overview
- 127 Startup parameters overview
- 129 Using Telset Administration to set the basic parameters
- 130 Configuring the initial parameters
- 133 Next step
- 135 Using Element Manager to set the basic parameters
- 136 Prerequisites
- 136 Accessing the BCM50 system
- 137 Configuring the initial parameters
- 139 Configuring the startup parameters
- 144 Next step
- 145 Using the Startup Profile to configure parameters
- 146 Startup Profile requirements
- 147 Configuring basic parameters
- 149 Next step
- 151 Completing the initial installation (optional)
- 152 Configuring the media bay module
- 153 Configuring modem settings
- 153 Checking for software updates
- 153 Configuring voice mail
- 153 Customizing security policies
- 154 Performing a backup
- 155 Connecting the BCM50 system to the LAN and WAN
- 156 Connecting the BCM50 system to the LAN
- 157 Connecting the BCM50 system to the WAN
- 159 Next step
- 161 Testing basic BCM50 functionality
- 165 Reset to factory settings
- 165 Reset levels
- 166 Activate the reset feature
- 169 Replacing the BCM50 system components
- 170 Preparing the system for maintenance
- 170 Restarting the system after maintenance
- 171 Replacing a power supply
- 172 Preparing the system for maintenance
- 172 Removing the power supply
- 172 Connect the new power supply
- 175 Replacing a main unit
- 176 Preparing the system for maintenance
- 176 Removing the main unit
- 177 Installing the new main unit
- 179 Replacing a media bay module
- 183 Replacing an expansion unit
- 184 Disconnecting the cables
- 184 Removing the expansion unit
- 186 Removing the MBM
- 186 Inserting the MBM in the new expansion unit
- 187 Installing the new expansion unit
- 189 Replacing an internal component
- 190 Special tools
- 190 Preparing the system for maintenance
- 190 Removing the main unit
- 190 Opening the main unit case
- 192 Removing an internal component
- 195 Inserting the new component
- 200 Closing the main unit case
- 201 Installing the main unit
- 201 Connecting the cables
- 203 RJ-21 telephony connector wiring chart
- 207 BRI wiring chart
- 209 LAN ports wiring chart
- 211 WAN ports wiring chart
- 213 Expansion ports wiring chart
- 215 DTM wiring chart
- 217 BRIM wiring chart
- 219 ADID wiring chart
- 221 GATM wiring chart
- 225 4x16 wiring charts
- 229 G4x16 and G8x16 wiring charts
- 233 DSM16 and DSM32 wiring charts
- 237 ASM8, ASM8+, and GASM wiring chart
- 239 Market profile attributes
- 239 Interface availability
- 239 Analog interfaces
- 240 Digital interfaces
- 241 Tones and cadences
- 248 Core parameters for market profiles
- 260 Analog Trunk parameters
- 264 GASM8 parameters
- 266 GASI parameters
- 268 ATA2 parameters
- 268 ATA2 DR6
- 270 ATA2 DR7
- 271 ISDN line services
- 272 Analog and digital trunk types
- 275 Index