Interior Water Filtration System

Model 67003523-750 Capacity 750 Gallons (2839 Liters))

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI

Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, p-Dichlorobenzene,

Carbofuran, Toxaphene, Cysts, Turbidity, Asbestos, Tetrachloroethylene and Lindane.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

Aesthetic Effects

Chlorine Taste/Odor

Particulate Class I *

Contaminant

Reduction

Lead: @ pH 6.5

Lead: @ pH 8.5

Mercury: @ pH 6.5

Mercury: @ pH 8.5

Benzene p-Dichlorobenzene

Carbofuran

Toxaphene

Atrazine

Asbestos

Live Cysts ‡

Turbidity

Lindane

Tetrachloroethylene

NSF Reduction

Requirements

50% reduction

85% reduction

NSF Reduction

Requirements

0.010 mg/L

0.010 mg/L

0.002 mg/L

0.002 mg/L

0.005 mg/L

0.075 mg/L

0.040 mg/L

0.003 mg/L

0.003 mg/L

>99%

>99.95%

0.5 NTU

0.0002 mg/L

0.005 mg/L

Average

Influent

2.00 mg/L

14,000,000 #/mL

Average

Influent

0.150 mg/L †

0.150 mg/L †

0.006 mg/L

0.0059 mg/L

0.0133 mg/L

0.210 mg/L

0.0753 mg/L

0.015 mg/L

0.0102 mg/L

126.5 MF/L

122,500 #/L

10.5 NTU

0.0019 mg/L

0.015 mg/L

Influent Challenge

Concentration

2.0 mg/L ± 10%

At least 10,000 particles/mL

Influent Challenge

Concentration

0.15 mg/L ± 10%

0.15 mg/L ± 10%

Maximum

Effluent

0.06 mg/L

370,000 #/mL **

Maximum

Effluent

< 0.001 mg/L

< 0.001 mg/L

0.006 mg/L ± 10%

0.006 mg/L ± 10%

0.0005 mg/L

0.0018 mg/L

0.015 mg/L ± 10% 0.0005 mg/L

0.225 mg/L ± 10% < 0.0005 mg/L

Average

Effluent

0.050625 mg/L

196,666 #/mL

Minimum%

Reduction

97.00%

97.40%

Average

Effluent

< 0.001 mg/L

< 0.001 mg/L

Minimum%

Reduction

>99.30%

>99.30%

0.0003 mg/L

0.00073 mg/L

91.70%

69.20%

0.0005 mg/L 96.10%

< 0.0005 mg/L >99.80%

0.08 mg/L ± 10%

0.015 ± 10%

0.027 mg/L

< 0.001 mg/L

0.009 mg/L ± 10% 0.0027 mg/L

10 7 to 10 8 fibers/L ††

50,000/L min.

11 ± 1 NTU

< 0.17 MF/L

< 1 #/L ‡

0.30 NTU

0.008 mg/L

< 0.001 mg/L

0.00105 mg/L

< 0.17 MF/L

< 1 #/L ‡

0.125 NTU

64.60%

>93.3%

76.30%

>99.99%

>99.99%

97.30%

0.002 ± 10% < 0.00016 mg/L 0.000035 mg/L 91.80%

0.015 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L >96.6%

Average%

Reduction

97.52%

99.00%

Average%

Reduction

>99.30%

>99.30%

95.00%

88.10%

96.30%

>99.80%

73.45%

>93.3%

89.40%

>99.99%

>99.99%

98.80%

97.90%

>96.6%

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F

(20°C ± 3°C).

■ It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

■ Refer to the “Water Filtration System” section for the

Manufacturer’s name and telephone number.

■ The disposable water filter should be replaced at least every

6 months.

■ Refer to the “Warranty” section for the Manufacturer’s limited warranty.

■ The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter.

When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. For models without filter status lights, replace the filter every 6 months. Use replacement filter model 67003523-750. 2011 suggested retail price of

$44.99 U.S.A./$49.95 Canada. Prices are subject to change without notice.

Application Guidelines/Water Supply Parameters

Water Supply

Water Pressure

Water Temperature

Service Flow Rate

City or Well

35 - 120 psi (241 - 827 kPa)

33 ° - 100°F (1° - 38°C)

0.78 gpm (2.9 L/min.) @ 60 psi

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

* Class I particle size: >0.5 to <1 um

** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

† These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

†† Fibers greater than 10 um in length

‡ Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

18

Interior Water Filtration System

Model UKF8001AXX-200 Capacity 200 Gallons (757 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of

Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, p-Dichlorobenzene, Carbofuran, Toxaphene, Cysts, Turbidity,

Asbestos, O-Dichlorobenzene, Ethylbenzene, Chlorobenzene, Endrin, Tetrachloroethylene and Lindane.

Substance Reduction

Aesthetic Effects

Chlorine Taste/Odor

Particulate Class I *

Contaminant

Reduction

Lead: @ pH 6.5

Lead: @ pH 8.5

Mercury: @ pH 6.5

Mercury: @ pH 8.5

Benzene p-Dichlorobenzene

Carbofuran

Toxaphene

Atrazine

Asbestos

Live Cysts

Turbidity

Lindane

Tetrachloroethylene

O-Dichlorobenzene

Ethylbenzene

Chlorobenzene

Endrin

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

NSF Reduction

Requirements

50% reduction

85% reduction

NSF Reduction

Requirements

0.010 mg/L

0.010 mg/L

0.002 mg/L

0.002 mg/L

0.005 mg/L

0.075 mg/L

0.040 mg/L

0.003 mg/L

0.003 mg/L

>99%

>99.95%

0.5 NTU

0.0002 mg/L

0.005 mg/L

0.6 mg/L

0.7 mg/L

0.1 mg/L

0.002 mg/L

Average

Influent

2.00 mg/L

14,000,000 #/mL

Average

Influent

0.150 mg/L †

0.150 mg/L †

0.006 mg/L

0.0059 mg/L

0.0133 mg/L

0.210 mg/L

0.0753 mg/L

0.015 mg/L

0.0102 mg/L

126.5 MF/L

122,500 #/L

10.5 NTU

0.0019 mg/L

0.015 mg/L

1.7 mg/L

2.2 mg/L

2.0 mg/L

0.007 mg/L

Influent Challenge

Concentration

2.0 mg/L ± 10%

At least 10,000 particles/mL

Influent Challenge

Concentration

0.15 mg/L ± 10%

0.15 mg/L ± 10%

Maximum

Effluent

0.06 mg/L

370,000 #/mL **

Maximum

Effluent

< 0.001 mg/L

< 0.001 mg/L

0.006 mg/L ± 10%

0.006 mg/L ± 10%

0.0005 mg/L

0.0018 mg/L

0.015 mg/L ± 10% 0.0005 mg/L

0.225 mg/L ± 10% < 0.0005 mg/L

Average

Effluent

0.050625 mg/L

196,666 #/mL

Minimum%

Reduction

97.00%

97.40%

Average

Effluent

< 0.001 mg/L

< 0.001 mg/L

Minimum%

Reduction

>99.30%

>99.30%

0.0003 mg/L

0.00073 mg/L

91.70%

69.20%

0.0005 mg/L 96.10%

< 0.0005 mg/L >99.80%

0.08 mg/L ± 10%

0.015 ± 10%

0.027 mg/L

< 0.001 mg/L

0.009 mg/L ± 10% 0.0027 mg/L

10 7 to 10 8 fibers/L ††

50,000/L min.

11 ± 1 NTU

< 0.17 MF/L

< 1 #/L ‡

0.30 NTU

0.008 mg/L

< 0.001 mg/L

0.00105 mg/L

< 0.17 MF/L

< 1 #/L ‡

0.125 NTU

64.60%

>93.3%

76.30%

>99.99%

>99.99%

97.30%

0.002 ± 10% < 0.00016 mg/L 0.000035 mg/L 91.80%

0.015 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L >96.6%

1.8 mg/L ± 10%

2.1 mg/L ± 10%

< 0.5 mg/L

0.0048 mg/L

< 0.5 mg/L

0.11 mg/L

>99.9%

99.80%

2.0 mg/L ± 10% 0.0038 mg/L

0.006 mg/L ± 10% 0.0004 mg/L

0.0008 mg/L

0.0002 mg/L

99.80%

94.30%

Average%

Reduction

97.52%

99.00%

Average%

Reduction

>99.30%

>99.30%

95.00%

88.10%

96.30%

>99.80%

73.45%

>93.3%

89.40%

>99.99%

>99.99%

98.80%

97.90%

>96.6%

>99.9%

99.90%

99.90%

96.80%

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.55 gpm (2.08 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F ±

5°F (20°C ± 3°C).

■ It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

■ Refer to the “Water Filtration System” section for the

Manufacturer’s name and telephone number.

■ The disposable water filter should be replaced at least every

6 months.

■ Refer to the “Warranty” section for the Manufacturer’s limited warranty.

■ The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter.

When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. For models without filter status lights, replace the filter every 6 months. Use replacement filter model UKF8001AXX-200. 2011 suggested retail price of

$44.99 U.S.A./$49.95 Canada. Prices are subject to change without notice.

Application Guidelines/Water Supply Parameters

Water Supply

Water Pressure

Water Temperature

Service Flow Rate

City or Well

35 - 120 psi (241 - 827 kPa)

33° - 100°F (1° - 38°C)

0.55 gpm (2.08 L/min.) @ 60 psi

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

* Class I particle size: >0.5 to <1 um

** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

† These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

†† Fibers greater than 10 um in length

‡ Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

19

advertisement

Related manuals

advertisement

Table of contents