1.4.5.4 Disable

OPC Client RDI Configuration

Checking this option will disable the object being configured. It can be enabled at a later stage by selecting the box again, which will remove the check.

1.4.5.5 Tag Definition

The OPC Tag definition is to be entered here. It can be entered here automatically by using the

OpenEnterprise Tag Browser, which can be accessed by selection of the [Browse] button to the right of this field.

1.4.5.6 Browse for Signal Tag

When this button is selected, the OpenEnterprise Tag Browser opens, and the user is able to select the OPC Server and the required Tag item. The Tag is then passed back to the Tag Definition field on the OPC Item dialog of the OPC Client RDI configuration tool. For more information on this component, see the OpenEnterprise Tag Browser help file.

1.4.5.7 OPC Request Data Type

The data format with which the OPC Client RDI will request the value for the item from the OPC

Server. This field is filled in automatically when a Tag is imported from the OpenEnterprise Tag

Browser.

1.4.5.8 OPC Database Table

The table to which the OPC Item belongs, based upon its Data Type. This field is filled in automatically when a Tag is imported from the OpenEnterprise Tag Browser.

1.4.5.9 OPC Item Description

The user can provide a helpful description of the OPC Item here.