Technical Specifications. Dell PowerEdge M1000e

Add to My manuals
88 Pages

advertisement

Technical Specifications. Dell PowerEdge M1000e | Manualzz

6

Technical Specifications

Table 17. Enclosure Specifications

Physical

Height

Width

Depth

Weight (maximum)

Weight (empty)

44.0 cm (17.3 inch)

44.7 cm (17.6 inch)

75.5 cm (29.7 inch)

200.5 kg (442 lb)

44.6 kg (98.1 lb)

Table 18. Power Supply Module

Power Supply Module

AC/DC power supply (per power supply module) (2700 W)

Wattage

Connector

Heat dissipation

Maximum inrush current

2700 W

IEC C20

1205 BTU/hr (maximum)

Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less.

AC/DC power supply (per power supply module) (3000 W)

Wattage

Connector

Heat dissipation

NOTE: Heat dissipation is calculated using the power supply wattage rating.

3000 W

IEC 320

1200 BTU/hr (maximum)

Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less.

16 A, 200 V AC to 240 V AC, 50 Hz/60 Hz (3000 W power supply) System voltage requirements

NOTE: This system is also designed to be connected to

IT power systems with a phase to phase voltage not exceeding 230 V.

16 A, 100 V AC to 240 V AC, 50 Hz/60 Hz (2700 W power supply)

DC/DC power supply (per power supply)

Wattage

Connector

Heat dissipation

Maximum inrush current

System voltage requirements

2700 W

Molex # 394260002 at PSU end, mating connector Molex #

39422-0012

1205 BTU/hr (maximum)

Under typical input voltage conditions and over the entire system ambient operating range, the inrush current may reach 120 A per power supply for 10 ms or less.

75 A, 48 V DC to 60 V DC

84 Technical Specifications

Table 19. Optional Avocent iKVM Module

Optional Avocent iKVM Module

Externally accessible connectors

USB

ACI port

Video

Table 20. Chassis Management Controller Module

Chassis Management Controller Module

Externally accessible connectors

Remote management

Two 4-pin, USB 2.0-compliant connectors for keyboard and mouse support

RJ-45

15-pin VGA

Serial

Video

Battery

Table 21. Enclosure Control Panel

Enclosure Control Panel

Externally accessible connectors

USB

Two dedicated 10/100/1000 Mb RJ-45 (for integrated Ethernet remote access controller). Gb port connects to the external management network. STK port allows CMCs in adjacent enclosures to be daisy chained.

9-pin, DTE, 16550-compatible

15-pin VGA

CR 2032 3.0-V Lithium ion coin cell

Video

LCD panel features

Table 22. I/O Module Specifications

Cisco Nexus B22 Fabric Extender Module

Externally accessible connectors

Two 4-pin, USB 2.0-compliant connectors for keyboard and mouse support

15-pin VGA

Four cursor control keys, one select key, LCD screen

Sixteen 10 Gb (internal) Ethernet ports and Eight 10 Gigabit Ethernet

SFP+ ports that support 10Gbase-SR, 10Gbase-LR, and 10Gbase-ER fabric connections.

Table 23. Environmental Specifications

Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/ environmental_datasheets.

Standard Operating Temperature Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-rate maximum allowable dry bulb temperature at 1 °C per 300 m above 900 m (1

°F per 550 ft).

Expanded Operating Temperature

NOTE: When operating in the expanded temperature range, system performance may be impacted.

NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.

< 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.

Technical Specifications 85

Environmental

< 1% of annual operating hours

Expanded Operating Temperature Restrictions

Storage Temperature

NOTE: Outside the standard operating temperature (10

°C to 35 °C), the system can operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual operating hours.

For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1

°F per 319 ft).

–5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.

NOTE: Outside the standard operating temperature (10

°C to 35 °C), the system can operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual operating hours.

For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1

°F per 228 ft).

• Install blades that fulfill the requirements for expanded operating temperature range.

NOTE: For more information on the blade-specific restrictions for the expanded operating temperature range, see the technical specifications in the blade's

Owner's Manual

at dell.com/support/manuals.

• 2700 W power supplies are supported as per the power supply rated capacity.

• 3000 W power supplies are supported with a capacity of 2800

W per power supply.

• Install fans of the following ratings:

• 12 V, 5.0 A

• 12 V, 6.30 A

• Only the following I/O modules are supported:

• Brocade M5424 FC8 I/O module

• Dell M8428-k 10 Gb converged network switch

• Cisco 1 GE 3130X-s switch

• Mellanox M3601Q DDR/QDR switch

• Dell PowerConnect M8024-k switch

• Dell PowerConnect M6220 Ethernet switch I/O module

• Dell PowerConnect M8024 10 Gb Ethernet switch I/O module

–40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour.

86 Technical Specifications

advertisement

Related manuals

advertisement

Table of contents