REAR OF SYSTEM
The computer and the UPS are accessible from the back of the system.
Power In
Disconnect Switch
Onboard Computer UPS
ONBOARD COMPUTER
The onboard computer is the central control unit for the Fortus 900mc. This computer also runs the touchscreen software that provides for the system's user interface.
UPS
The UPS unit is a battery standby system that supplies power (AC voltage) to the computer, oven lights, and head cooling fan in the event of a loss of AC power. It does not power the entire system. You can access the
UPS from the back of the system. In the event of an overcurrent condition, the UPS is protected by a combination on/off switch and circuit breaker located directly above the main breaker.
• It shuts itself off if power is not restored to the system.
• If power is lost to the system you may need to manually power the unit back up. However, this should not be necessary unless the UPS has been manually turned off. To regain power, hold the “On” button on the front of the UPS unit until a beep is heard and/or LED lights appear.
• The LED display shows status of the UPS.
Alarm Indicator
(Red)
Up
On/Off
Button
On battery
Indicator
(Yellow)
Escape
Enter
Down
Power On
Indicator
(Green)
9
POWER IN DISCONNECT SWITCH
The Power In Disconnect switch, located at the back of the system, acts as the main circuit breaker. Rotating this switch to OFF will remove AC power to the system. There is a Lockout Bar that can be used to lock the switch in the off position.
Warning: High voltage is present in the system when powered off and unplugged because of the Uninterruptible Power supply (UPS).
Lockout Bar
POWER CONNECTION
Warning: A licensed electrician must perform all wiring from service connect to the transformer, and from the transformer to the system - including all connectors, cables and proper strain relief.
This system requires a high voltage connection, which is made at the top right-hand corner at the back of the system. High voltage is applied to the system using a Delta connection. The main breaker must be off until a
Stratasys authorized Service Technician has verified the connection. This system is only provided with a Delta connection.
High Voltage
Power Cable
Connection
NETWORK AND AIR SUPPLY CONNECTIONS
Processed job files are transferred to the Fortus system through your facility’s Ethernet network. An RJ45 network connector is located on the top right-hand corner at the back of the system. The air supply connection is located next to the RJ45 connector.
Power Cable
Connection
Air Supply
Connector
RJ45
Connector
10