Understanding the MCS. Juniper JUNOS, JUNOS - NETWORK OPERATION GUIDE REV1
Anúncio
Anúncio
JUNOS Internet Software Network Operations Guide: Hardware
What it Means The command output displays the status and temperature for the SFM and its two serialized components: the SPP card and the SPR card.
Alternative Action If there is a problem with the SFM status, you can display more detailed environmental information with the following CLI command: user@host> show chassis environment sfm user@host> show chassis environment sfm
SFM 0 status:
State Online
SPP temperature 36 degrees C / 96 degrees F
SPR temperature 45 degrees C / 113 degrees F
SPP Power:
1.5 V 1501 mV
2.5 V 2485 mV
3.3 V 3291 mV
5.0 V 5020 mV
5.0 V bias 4974 mV
SPR Power:
1.5 V 1501 mV
2.5 V 2492 mV
3.3 V 3301 mV
5.0 V 5028 mV
5.0 V bias 4986 mV
8.0 V bias 8305 mV
CMB Revision 12
SFM 1 status:
[...Output truncated...]
SFM 2 status:
[...Output truncated...]
SFM 3 status:
State Offline
- Hard FPC error
[...Output truncated...]
The command output displays the SFM slot, status, and temperature of the air flowing past the SPP card and the SPR card. It also displays information about the
SFM power supplies. The chassis management bus (CMB) slave revision level is also displayed.
You can display the environmental status of a particular SFM with the following CLI command: user@host> show chassis environment sfm sfm-lot
352 !
Monitoring the SFM Status
Chapter 26: Monitoring the SFMs
Displaying SFM Alarms
Steps To Take To display SFM alarms and error messages, follow these steps:
1.
Display Current SFM Alarms on page 353
2.
Display SFM Error Messages in the System Log File on page 353
3.
Display SFM Error Messages in the Chassis Daemon Log File on page 354
Step 1: Display Current SFM Alarms
Action To display the current SFM alarms, use the following CLI command: user@host> show chassis alarms
Sample Output user@host> show chassis alarms
4 alarms currently active
Alarm time Class Description
2002-05-14 09:23:58 PDT Major SFM Failure
2002-05-14 09:23:55 PDT Major SFM Failure
2002-05-14 09:23:53 PDT Major SFM Failure
2002-05-14 09:20:51 PDT Major No SFM Online, the box is not forwarding
What it Means The command output displays the alarm date, time, severity level, and description.
Step 2: Display SFM Error Messages in the System Log File
Action To display the SFM error messages in the system log file, use the following CLI command: user@host> show log messages
Sample Output user@host> show log messages
Jun 11 20:31:11 hissy-re0 craftd[556]: Major alarm set, No SFM Online, the box is not forwarding
Jun 11 20:31:11 hissy-re0 alarmd[555]: Alarm set: SFM color=RED, class=CHASSIS, reason=No SFM Online, the box is not forwarding
What it Means The messages system log file records the time the failure or event occurred, the severity level, a code, and a message description. You can also use the show log messages | match sfm command to see error messages that are generated when an
SFM fails or is offline. Use this information to diagnose a power supply problem and to let the Juniper Networks Technical Assistance Center (JTAC) know what error messages were generated and the router events that occurred before and after the problem. For more information about system log messages, see the JUNOS System
Log Messages Reference .
Displaying SFM Alarms !
353