Troubleshooting. Briggs & Stratton 2050PSI, CleanShot 020206-0, CLEANSHOT 2050PSI

Add to My manuals
36 Pages

advertisement

Troubleshooting. Briggs & Stratton 2050PSI, CleanShot 020206-0, CLEANSHOT 2050PSI | Manualzz

CleanShot™ 2050 PSI Pressure Washer

TROUBLESHOOTING

Problem Cause

1.

Nozzle in low pressure mode.

2.

Water inlet is blocked.

3.

Inadequate water supply.

4.

Inlet hose is kinked or leaking.

Pump has following problems: failure to produce pressure, erratic pressure, chattering, loss of pressure, low water volume.

5.

Clogged inlet hose strainer.

6.

Water supply is over 100°F.

7.

High pressure hose is blocked or leaks.

Detergent fails to mix with spray.

8.

Gun leaks.

9.

Nozzle is obstructed.

10. Pump is faulty.

1.

Detergent siphoning tube is not submerged.

2.

Chemical filter is clogged or cracked.

3.

Dirty in-line filter.

4.

Nozzle is in high pressure mode.

Engine runs good at no-load but

"bogs" when load is added.

Pressure washer stops during operation.

Engine speed is too slow.

Out of gasoline.

Correction

1.

Pull nozzle backward for high pressure mode.

2.

Clear inlet.

3.

Provide adequate water flow.

4.

Straighten inlet hose, patch leak.

5.

Check and clean inlet hose strainer.

6.

Provide cooler water supply.

7.

Clear blocks in outlet hose.

8.

Replace gun.

9.

Clean nozzle.

10. Contact Generac service facility.

1.

Insert detergent siphoning tube into detergent.

2.

Clean or replace filter/detergent siphoning tube.

3.

See "Check In-Line Filter".

4.

Push nozzle forward for low pressure mode.

Move throttle control to FAST position. If engine still "bogs down", contact Briggs and Stratton service facility.

Fill fuel tank.

15

advertisement