Troubleshooting

Fault Possible cause

The device does not cool (plug is inserted). Temperature indicator LEDs for 11 °C (51 °F) and 14 °C (57 °F) light up permanently.

The demo mode is activated.

Suggested remedy

Try using another plug socket.

The device does not cool. Temperature indicator LEDs do not glow.

No voltage present in the AC voltage socket.

The device does not cool (plug is inserted). Temperature indicator LEDs glow.

The cooling element is defective.

Contact authorized service agent for repair.

Switch off the demo mode (fig.

g , page 10).

The interior LED lamp stays on permanently even when the wine cooling drawer is closed.

The presentation mode is activated.

Switch off the presentation mode

(fig.

f , page 10).

The device does not cool sufficiently.

Temperature indicator LEDs glow.

The upper temperature indicator LED flashes repeatedly for 1 time.

The upper temperature indicator LED flashes repeatedly for 3 times.

The upper temperature indicator LED flashes repeatedly for 4 times.

The upper temperature indicator LED flashes repeatedly for 5 times.

The cooling element is defective.

The ventilation is insufficient.

The temperature sensor is defective.

The inner fan is defective.

The outer fan is defective.

The drawer is opened for too long.

Contact authorized service agent for repair.

Remove any obstruction or soiling from the inlet and outlet vents.

Contact authorized service agent for repair.

Contact authorized service agent for repair.

Contact authorized service agent for repair.

Close the drawer.

The drawer is not closed properly.

Close the drawer properly.

The upper temperature indicator LED flashes repeatedly for 6 times.

The compressor is defective.

Contact authorized service agent for repair.

18 4445103702