Furnace Rem oval. Suburban SFV-42F, NT-24SP, SH-35, P-30S/40, P-40, SF-35, SH-42F, NT.12SE, SFV-42, NT.16SE
Add to My manuals40 Pages
advertisement
FURNACE REMOVAL
To replace parts or service the SUBURBAN fam ily of RV furnaces, it is necessary to follow these steps:
DD-17DSI
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Rem ove the vent cap assem bly by rem oving applicable screws.
3.
Rem ove the cabinet front two (2) screws.
4.
Rem ove the applicable screws securing the furnace to the coach floor.
5.
Rem ove duct from side of furnace, if equipped.
6.
Rem ove the furnace from the cabinet area to gain access to com bustion cham ber and applicable parts.
7.
Som e parts can be accessed without rem oval of the com plete furnace.
8.
To re-install, reverse this procedure.
9.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
NT-12/16/20S
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Rem ove the vent cap assem bly by rem oving applicable screws.
3.
Rem ove the cabinet front two (2) screws.
4.
Rem ove the (1) one tie down screw securing the cham ber to the cabinet.
5.
Rem ove the furnace from the cabinet by pulling cham ber outward com pletely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
NT-12/16/20SE
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Rem ove the vent cap assem bly by rem oving applicable screws.
3.
Rem ove the cabinet front two (2) screws.
4.
Rem ove the (2) two tie down screws securing the cham ber to the cabinet.
5.
Rem ove the furnace from the cabinet by pulling cham ber outward com pletely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
NT-24/30/34SP and NT-40
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Rem ove the vent cap assem bly by rem oving applicable screws and one (1) flue retaining screw. Not applicable to NT-40.
3.
Rem ove the cabinet front two (2) screws.
4.
Rem ove the (2) two tie down screws securing the cham ber to the cabinet.
5.
Rem ove the furnace from the cabinet by pulling cham ber outward com pletely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
35
FURNACE REMOVAL
SF-20/25/30/35/42, SFV-20/25/30/35/42, SH-35/42 and SHD-2542
1.
Rem ove the vent cap assem bly from the outside access door by rem oving applicable screws, also the four (4) screws retaining the door to the fram e. Rem ove the door to gain access to the furnace.
2.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
3.
Rem ove the (1) one tie down screw securing the cham ber to the cabinet.
4.
Rem ove the furnace from the cabinet by pulling cham ber outward com pletely to gain access to all controls and applicable parts.
5.
To re-install, reverse this procedure.
6.
Rewire applicable wires and perform a leak test on all fittings.
Perform a drop pressure test.
SF-20/25/30/35/42F, SFV-20/25/30/35/42F and SH-35/42F
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Rem ove the vent cap assem bly by rem oving applicable screws.
3.
Rem ove the cabinet front two (2) screws.
4.
Rem ove the (1) one tie down screw securing the cham ber to the cabinet.
5.
Rem ove the furnace from the cabinet by pulling cham ber outward com pletely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
P-30S and P-40
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Rem ove the vent cap assem bly by rem oving applicable screws and one (1) flue retaining screw. (Not applicable to P40.)
3.
Rem ove the cabinet front two (2) screws.
4.
Rem ove the (2) two tie down screw securing the cham ber to the cabinet.
5.
Rem ove the furnace from the cabinet by pulling cham ber outward com pletely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
36
advertisement
Related manuals
advertisement
Table of contents
- 3 General Service Inform ation
- 4 Furnace Spec Sheet
- 5 Installation
- 6 Vent Assem bly Illustrations
- 16 Return Air Illustrations
- 17 Ducting Illustrations
- 18 Installation Requirem ents (DD, NT and P Model Furnaces)
- 19 Installation Requirem ents (SF, SH and SHD-2542 Model Furnaces)
- 20 Installation Requirem ent (SFV Model Furnaces)
- 21 Furnace Specifications (DD, NT and P Model Furnaces)
- 22 Furnace Specifications (SF, SFV, SH, and SHD-2542 Model Furnaces)
- 23 Sequence of Operation (Tim e Delay Relay Equipped Furnaces)
- 24 Sequence of Operation (Fan Control Module Board (520820) Equipped Furnaces)
- 25 Sequence of Operation (24 VAC Fan Control Module Board (520947)
- 26 Sequence of Operation (SHD-2542 Furance)
- 27 Trouble Shooting Flow Chart (Furnaces Equipped with Tim e Delay Relay)
- 28 Trouble Shooting Flow Chart (Furnaces Equipped with Fan Control Module Board)
- 29 for Suburban 24-Volt AC Electronic Ignition Furnaces
- 30 W iring Diagram s
- 35 Furnace Rem oval
- 37 SF, SH and SHD-2542 Electrode Gap Specifications & Positioning
- 38 NT and Park Model Electrode Gap Specifications & Positioning
- 39 Maintenance