![NT and Park Model Electrode Gap Specifications & Positioning. Suburban SFV-42F, NT-24SP, SH-35, P-30S/40, P-40, SF-35, SH-42F, NT.12SE, SFV-42, NT.16SE | Manualzz NT and Park Model Electrode Gap Specifications & Positioning. Suburban SFV-42F, NT-24SP, SH-35, P-30S/40, P-40, SF-35, SH-42F, NT.12SE, SFV-42, NT.16SE | Manualzz](http://s1.manualzz.com/store/data/002326402_1-45196fd0b122c9220a545bebefb681a0-360x466.png)
NT ELECTRODE GAP SPECIFICATIONS
AND POSITIONING
To assure consistent ignition of the burner, it is im portant for the electrode to be positioned properly over the top of the burner.
W hen replacing the electrode, or should you be experiencing ignition type problem s, the electrode should be positioned as outlined in the drawing.
1. 1/8" spark gap between electrode and ground.
2. Maintain electrode position of 3/16" over burner ports.
Figure 32
LO C A L FLA M E S E N S E
PARK MODEL ELECTRODE GAP SPECIFICATIONS
AND POSITIONING
To assure consistent ignition of the burner, it is im portant for the electrode to be positioned properly over the top of the burner.
W hen replacing the electrode, or should you be experiencing ignition type problem s, the electrode should be positioned as outlined in the drawing.
Figure 33
R E M O TE FLA M E S E N S E
1. 1/8" spark gap between electrode and ground.
2. 1/4" spark gap between ground and flam e sensor.
3. Maintain electrode position of 3/16" over burner ports.
38
advertisement
Related manuals
advertisement
Table of contents
- 3 General Service Inform ation
- 4 Furnace Spec Sheet
- 5 Installation
- 6 Vent Assem bly Illustrations
- 16 Return Air Illustrations
- 17 Ducting Illustrations
- 18 Installation Requirem ents (DD, NT and P Model Furnaces)
- 19 Installation Requirem ents (SF, SH and SHD-2542 Model Furnaces)
- 20 Installation Requirem ent (SFV Model Furnaces)
- 21 Furnace Specifications (DD, NT and P Model Furnaces)
- 22 Furnace Specifications (SF, SFV, SH, and SHD-2542 Model Furnaces)
- 23 Sequence of Operation (Tim e Delay Relay Equipped Furnaces)
- 24 Sequence of Operation (Fan Control Module Board (520820) Equipped Furnaces)
- 25 Sequence of Operation (24 VAC Fan Control Module Board (520947)
- 26 Sequence of Operation (SHD-2542 Furance)
- 27 Trouble Shooting Flow Chart (Furnaces Equipped with Tim e Delay Relay)
- 28 Trouble Shooting Flow Chart (Furnaces Equipped with Fan Control Module Board)
- 29 for Suburban 24-Volt AC Electronic Ignition Furnaces
- 30 W iring Diagram s
- 35 Furnace Rem oval
- 37 SF, SH and SHD-2542 Electrode Gap Specifications & Positioning
- 38 NT and Park Model Electrode Gap Specifications & Positioning
- 39 Maintenance