Basic Functioning. Netgear STM600 - ProSecure Web And Email Threat Management Appliance, STM300 - ProSecure Web And Email Threat Management Appliance, STM150 - ProSecure Web And Email Threat Management Appliance

Add to My manuals
261 Pages

advertisement

Basic Functioning. Netgear STM600 - ProSecure Web And Email Threat Management Appliance, STM300 - ProSecure Web And Email Threat Management Appliance, STM150 - ProSecure Web And Email Threat Management Appliance | Manualzz

ProSecure Web/Email Security Threat Management (STM) Appliance

Basic Functioning

After you turn on power to the STM, check that the following sequence of events occurs:

1.

When power is first applied, verify that the Power LED is on.

2.

After approximately 2 minutes, verify that:

a. The Test LED (STM150) or Status LED (STM300 and STM600) is no longer lit.

b. The left LAN port LEDs are lit for any local ports that are connected.

c. The left WAN port LEDs are lit for any WAN ports that are connected.

If a port’s left LED is lit, a link has been established to the connected device. If a port is connected, verify the following right LED behavior in relation to the established port speed:

Connected to a 1000-Mbps device:

-

STM150: The right LED is green.

-

STM300: The right LED is amber.

-

STM600: The right LED is amber.

Connected to a 100-Mbps device:

-

STM150: The right LED is amber.

-

STM300: The right LED is green.

-

STM600: The right LED is green.

Connected to a 10-Mbps device: For all STM models, the right LED is off.

If any of these conditions does not occur, see the appropriate following section.

Power LED Not On

If the Power and other LEDs are off when your STM is turned on, make sure that the power cord is correctly connected to your STM and that the power supply adapter is correctly connected to a functioning power outlet. If the error persists, you have a hardware problem and should contact NETGEAR Technical Support.

Test LED or Status LED Never Turns Off

When the STM is powered on, the Test LED (STM150) or Status LED (STM300 and

STM600) turns on for approximately 2 minutes and then turns off when the STM has completed its initialization. If the Test LED (STM150) or Status LED (STM300 and STM600) remains on, there is a fault within the STM.

Chapter 7. Troubleshooting and Using Online Support | 223