Installation and User s Guide

Add to My manuals
92 Pages

advertisement

Installation and User s Guide | Manualzz

Pump Menu (12/14)

(Continued)

IntelliFlo

®

VSF+SVRS pump

From the IntelliFlo VSF+SVRS menu you can assign circuits to control the pump flow rate (GPM/RMP), priming, also filter, backwashing, vacuum functions and view the current pump status. For more information about the IntelliFlo VS, refer to the IntelliFlo VF Installation and User’s Guide (P/N 350075).

To assign up eight (8) pump speeds and circuits for the IntelliFlo VS pump:

Main Menu 12/14

Pumps

Pump Type

[INTELLIFLO VF ]

Menu button: Select the Pumps 12/14 menu.

Right button: Press the button to view the type of pump to select.

Up/Down buttons: Select IntelliFlo VF them press Right button again to select.

Press Up/Down buttons to view the Pump Parameters menus: CIRC. SETUP,

and STATUS.

Press Right button to choose one of the parameters.

Pumps Parameters

Menu: CIRC. SETUP

Circuit Setup

1 - [ POOL ]

CIRCUIT SETUP: Press Right button to assign a circuit to the pump. Press Up/

Down buttons to view the circuits for the first of eight (8) pump circuits: [NONE,

SPA, POOL, AUX 1, AUX 2, AUX 3, FEATURE 1-4, SOLAR, HEATER,

POOL HEAT, SPA HEAT, FREEZE, POOL/SPA, and SOLAR/HT (solar/ heater)].

Assign Circuit

1 - [SPA ]

GPM/RPM Mode

GPM (RPM)

Assign Flows

1 - GPM: 80

GPM/RPM Mode: Press the Right button to set the GPM and RPM pump speed.

Press Up/Down button to toggle between RPM and GPM/PSI.

The Assign Flows screen displays. Press Up/Down buttons to set the pump flow rate from 15 - 130 GPM. The default flow rate is 30 GPM. The preset speed for each button is: Speed 1 button 1100 RPM (30 GPM), Speed 2 button 1500 RPM,

Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM.

Assign PSI

1 - PSI: DSBL

Press the Right button again to set the PSI setting. Press Up/Down buttons to set pump pressure setting from 1 to 30 PSI.

Assign Flows

1 - GPM: PSI

Press Right button to select the circuit. Note: Selecting “Pool/Spa” or

“Solar/HT” combines several circuits into the same pump speed for pool and spa or for solar and heater combination systems. Normally this would require programming two separate pump speeds for each function. Using one of these selections, free-up one of the four pump speed for other uses.

Assign Speeds

1 - RPM: 7710

Press Right button to continue to assign pump FILT. CIRC. and CIRCUITS. You can assign up to eight (8) pump speeds and circuits.

When finished assigning pump flow rate and circuits, press the Right button until

FLOWS is displayed, then press the Up/Down buttons and select FILTER.

Press Right button to select Assign Flows. Press the Up/Down buttons to set the flow rate from 15-150 GPM.

Press Right button to select Assign PSI. Press the Up/Down buttons to set the pressure rate from 1-30 PSI.