Installation and User s Guide


Add to my manuals
92 Pages

advertisement

Installation and User s Guide | Manualzz

71

Temperature vs. Resistance Data

SunTouch systems use 10k

Ωαττ thermistor sensors. When the solar sensor is disconnected from the

SunTouch system, the sensor will read 10k

Ω at 77º F (25ºC). Refer to the following table for the resistance at other temperatures. An accurate reading should give a temperature setting that is accurate to ±0.2º C from 0 to 70 º C.

Temperature Resistance Temperature Resistance

o

C o

F

Ω

o

C o

F

Ω

7

10

13

15

-1

0

2

4.7

5

-9

-10

-7

-5

-4

-26

-25

-23

-21

-20

-18

-15

-12

45

50

55

59

30

32

35

40

41

15

14

20

23

25

-5

-4

0

-15

-13

-10

5

10

139,300

130,300

118,000

100,200

97,000

85,350

72,910

62,480

53,640

55,300

46,230

42,300

39,910

34,560

32,600

30,000

26,100

25,400

22,760

19,900

17,440

15,700

110

113

120

122

125

130

131

135

90

95

100

104

105

75

77

80

60

65

70

85

86

43

45

49

50

52

54

55

57

32

35

38

40

41

24

25

27

16

18

21

29

30

4,663

4,367

3,757

3,602

3,381

3,047

2,985

2,750

15,310

13,480

11,880

10,500

10,000

9,298

8,250

8,056

7,331

6,530

5,826

5,326

5,209

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide