Cautions and Warnings
Chapter 3
Maintaining the Hardware
This chapter describes how to replace disk drives, interpret LEDs, and troubleshoot hardware problems. For more information, see the following topics:
•
“Cautions and Warnings” in the next section
•
“Interpreting the Port LEDs” on page 19
•
“Disk Drive Replacement” on page 19
•
“Power Supply Replacement” on page 22
Cautions and Warnings
CAUTION:
Disconnect all power cords before servicing the WF-500 appliance.
WARNING:
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the battery manufacturer’s instructions.
WARNING:
Removal of the equipment’s top cover is to be done only by Palo Alto Networks trained service person(s).
Interpreting the Port LEDs
Each Ethernet port on the WF-500 appliance has two LEDs. Table 3 describes the LEDs.
Table 3. Port LEDs
LED Description
Left
Right
• Off
—No link
• Green
—100 Mbps link
• Amber
—1 Gbps link
Blinks yellow if there is network activity.
Disk Drive Replacement
The following section describes the procedures for replacing disk drives on the WF-500 appliance. The WF-500 appliance has 24 disk drive bays. Starting from left to right, the bays are labeled A1-A2, B1-B2 up to L1-L2. Only the first four drive bays (A1-A2, B1-B2) are
Palo Alto Networks Maintaining the Hardware • 19
Disk Drive Replacement available for use. Drives A1-A2 are a RAID 1 pair; drives B1-B2 are also a RAID 1 pair. The only drive maintenance you will need to perform is a replacement of a failed drive in one of the RAID pairs.
Note:
The disk drives in the front drive bays of the WF-500 appliance are hot swappable. For more details on replacing failed drives, refer to the
Palo Alto Networks
WildFire Administrator’s Guide
.
Replacing a WF-500 Appliance Disk Drive
This section describes the steps needed to remove and install a WF-500 appliance disk drive in the event of a drive failure in one of the RAID 1 pairs.
1.
Place an anti-static wrist strap on your wrist and connect it to ground.
2.
Identify the failed drive indicated by the red LED on the drive bay. You can also check the drive status by running the CLI command show system raid. You will see Disk Pair A and Disk Pair B and the failed drive will show Missing or Failed.
3.
Press the purple button on the drive bay for the failed drive to be replaced as shown in
Figure 11.
4.
Gently rotate the drive bay lever away from the drive until it stops.
5.
Gently pull on the lever to remove the drive from the system.
Figure 11. Disk Drive Replacement
6.
To install a new drive in the appliance, you will need to remove the old drive from the drive carrier. Place the failed drive/drive bay on a flat surface with the label side down and place the new drive next to it.
20 • Maintaining the Hardware Palo Alto Networks
Disk Drive Replacement
7.
Remove the four screws holding the drive in the drive bay and then remove the failed
disk drive. Figure 12 shows how the drive connects to the carrier.
Note:
If you are using a blank carrier that does not have a drive, a plastic blank will be in place of the drive. Remove the plastic blank before installing the new drive.
Figure 12. WF-500 Appliance Drive Carrier and Drive
SA
TA
SAS
SA
TA
SAS
SAS
TA
SA
SAS
TA
SA
8.
Put the new drive in the carrier and attach it to the carrier with the four screws as shown
in Figure 12.
9.
The drive bay lever should still be in the open position; if it is not, press the purple button on the drive bay to release the drive bay lever and pull it out until it is fully open.
10. With the handle of the drive fully extended, use the purple button to push the drive all the way into the empty slot. This will cause the lever to close part way. Push the lever all the
way inward to lock the drive bay into place as shown in Figure 11.
11. Now that the new drive is installed, you need to add it to the RAID 1 pair by running the
CLI command request system raid add <drive>. For example, if drive A2 failed in the A1/A2 RAID pair, you would run request system raid add A2.
12. To check the status of the new drive, run request system raid detail. In this example, drive A2 shows spare rebuilding as shown in the following output:
Disk Pair A Available
Status clean, degraded
Disk id A1 Present
Palo Alto Networks Maintaining the Hardware • 21