Appendix. Imagine communications Motion4 Server
Anuncio
Anuncio
Nexio Motion4 Server
Installation Reference
Appendix
Appendix
Baton DC Configuration Notes
Motion 4.7 includes a new Device Controller for Interra Systems Baton quality check device and adds
Baton DC to the installer under the Video Processing group.
Operation
The Baton Quality Control Device Controller uses personal Zenium engine just for Motion (deployed with
Motion), license server, a very simple blueprint, and the Zenium Baton plug-in to provide Baton QC support. The simple Web API can submit and monitor jobs in Zenium and then retrieve the job results.
The device controller generates a package (zip file) from the original report files.
Note: Always reusing the same Zenium instance ID without disposing of it allows it to stay loaded and so saves resources.
Deployment
The Baton DC is deployed with Motion.
The Zenium Server and the Zenium Repo Server that the DC uses must be deployed separately from
Motion. Motion doesn't necessarily have to be on the same machine as the device manager (all the URLs are configurable), but the default behavior assumes that it is.
Reference Note: For details on Zenium reference the Zenium Designer Users Guide.
Support Note: Contact support for Zenium components and related distributables.
Configuration notes:
1. The location of the file needs to be added in the Content Location in Baton
2. After installing Zenium and Motion, reboot the machine. If you get Kayak license error, restarting
DRCKayakServerServices may fix it
3. After installing Kayak server and plugin, go the links below to verify they are running properly:
-- http://localhost:42100/partitions/all
-- http://wtl-jefffox:15080/console/ (You should see the Motion computer is requiring Zenium license)
4. Motion can point to Zenium Server on other machine. Just change the config file here: "C:\Program
Files\Imagine
Communications\Motion\Server\devicemanager\DeviceControllers\Baton\batondc.exe.config"
© 2017 Imagine Communications Corp. Proprietary and Confidential. 4/12/2017 | Page 37
Nexio Motion4 Server
Installation Reference Appendix
5. If installing Motion first and then Zenium, run this bat file: "C:\Program Files\Imagine
Communications\Motion\Server\devicemanager\DeviceControllers\Baton\UploadPlugins.bat"
Logging
The following is provided for reference purposes.
Magellan Diagnostic Logging
The Magellan Diagnostic Logging viewer centralizes all the logging done by Motion 4.
All logging messages created by Motion 4 proper are listed under the Motion 4 application in the viewer
All the device controllers are listed under the Motion 4 Device Controllers application in the viewer.
Note: Magellan Diagnostic logging is embedded in the Motion4 server installer.
Reference Note: For information on installing, setting up, and using the Magellan Diagnostic Loggers, reference the ‘Magellan Diagnostic Logging v2_Getting Started‘ manual and ‘Magellan Diagnostic
Logging v2_Server Setup Guide‘.
Process Explorer: Diagnostic Logging Default Settings
With Motion 4.7 and higher the following are default settings for Process Explorer Diagnostic Logging:
Max storage: 4GB
© 2017 Imagine Communications Corp. Proprietary and Confidential. 4/12/2017 | Page 38
Nexio Motion4 Server
Installation Reference
file rolling size: 1GB
default verbosity: all but info and debug
This also means that no other verbosity settings are overwritten.
Appendix
© 2017 Imagine Communications Corp. Proprietary and Confidential. 4/12/2017 | Page 39
Descargar