advertisement
Sensor Cross Reference List
Sensor
Number
6Ah
Sensor Name
IOH Thermal Trip
(IOH Thermal Trip)
Details Section
3.2 BIOS POST owned Sensors (GID = 0001h)
Table 43: Discrete Thermal Sensors
Next Steps
The following table can be used to find the details of sensors owned by BIOS POST.
Table 6: BIOS POST owned Sensors
Sensor
Number
01h
06h
11h
12h
13h
83h
Sensor Name
Mirroring Redundancy State
POST Error
Sparing Redundancy State
Mirroring Configuration Status
Sparing Configuration Status
System Event
Details Section Next Steps
Mirrored Redundancy State Sensor
System Firmware Progress (Formerly
Sparing Redundancy State Sensor
Mirroring Configuration Status
Table 55: Mirrored Redundancy State Sensor Event Trigger Offset – Next Steps
System Firmware Progress (Formerly Post Error) – Next Steps
Table 59: Sparing Redundancy State Sensor Event Trigger Offset – Next Steps
Table 53: Mirroring Configuration Status Sensor Event Trigger Offset – Next Steps
Table 57: Sparing Configuration Status Sensor Event Trigger Offset – Next Steps
Not applicable
3.3 BIOS SMI owned Sensors (GID = 0033h)
The following table can be used to find the details of sensors owned by BIOS SMI.
12 Intel order number G74211-002 Revision 1.1
System Event Log Troubleshooting Guide for Intel
®
Sensor Cross Reference List
Table 7: BIOS SMI owned Sensors
03h
04h
05h
06h
Sensor
Number
02h
07h
14h
17h
18h
Sensor Name Details Section
Memory ECC Error
Legacy PCI Error
PCI Express Fatal Error
PCI Express Correctable Error
PCI Express Correctable errors
Intel
®
QuickPath Interface
Correctable Error
Intel
®
QuickPath Interface Nonfatal Error
Memory Address Parity Error
Intel
®
Error
QuickPath Interface Fatal
Intel
®
QuickPath Interface
Fatal2 Error
System Event
83h
Next Steps
Table 61: Correctable and Uncorrectable ECC Error Sensor Event Trigger Offset –
Table 68: Legacy PCI Error Sensor Event Trigger Offset – Next Steps
Table 66: PCI Express* Fatal Error Sensor Event Trigger Offset – Next Steps
Table 64: PCI Express* Correctable Error Sensor Event Trigger Offset – Next Steps
QPI Correctable Error Sensor – Next Steps
QPI Non-Fatal Error Sensor – Next Steps
Memory Address Parity Error Sensor Next Steps
QPI Fatal and Fatal #2 – Next Steps
QPI Fatal and Fatal #2 – Next Steps
Not applicable
Revision 1.1 Intel order number G74211-002 13
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 Introduction
- 11 Purpose
- 11 Industry Standard
- 11 Intelligent Platform Management Interface (IPMI)
- 12 Baseboard Management Controller (BMC)
- 13 Intelligent Power Node Manager Version
- 14 Basic Decoding of a SEL Record
- 14 Default Values in the SEL Records
- 18 Sensor Cross Reference List
- 18 BMC owned Sensors (GID = 0020h)
- 22 BIOS POST owned Sensors (GID = 0001h)
- 22 BIOS SMI owned Sensors (GID = 0033h)
- 24 Hot Swap Controller Firmware owned Sensors (GID = 00C0h/00C2h)
- 25 Node Manager / ME Firmware owned Sensors (GID = 002Ch or 602Ch)
- 26 Microsoft* OS owned Events (GID = 0041)
- 26 Linux* Kernel Panic Events (GID = 0021)
- 27 Power Subsystems
- 27 Voltage Sensors
- 31 Power Unit
- 31 Power Unit Status Sensor
- 32 Power Unit Redundancy Sensor
- 34 Power Supply
- 34 Power Supply Status Sensors
- 35 Power Supply AC Power Input Sensors
- 36 Power Supply Current Output % Sensors
- 37 Power Supply Temperature Sensors
- 39 Cooling Subsystem
- 39 Fan Sensors
- 39 Fan Speed Sensors
- 40 Fan Presence and Redundancy Sensors
- 43 Temperature Sensors
- 43 Regular Temperature Sensors
- 45 Thermal Margin Sensors
- 46 Processor Thermal Control % Sensors
- 47 Discrete Thermal Sensors
- 49 Processor Subsystem
- 49 Processor Status Sensor
- 50 Catastrophic Error Sensor
- 51 Catastrophic Error Sensor – Next Steps
- 51 CPU Missing Sensor
- 52 CPU Missing Sensor – Next Steps
- 52 QuickPath Interconnect Error Sensors
- 52 QPI Correctable Error Sensor
- 53 QPI Non-Fatal Error Sensor
- 54 QPI Fatal and Fatal
- 56 Memory Subsystem
- 56 Memory RAS Mirroring and Sparing
- 56 Mirroring Configuration Status
- 57 Mirrored Redundancy State Sensor
- 59 Sparing Configuration Status
- 60 Sparing Redundancy State Sensor
- 63 ECC and Address Parity
- 63 Memory Correctable and Uncorrectable ECC Error
- 65 Memory Address Parity Error
- 68 PCI Express* and Legacy PCI Subsystem
- 68 PCI Express* Errors
- 68 PCI Express* Correctable Errors
- 69 PCI Express* Fatal Errors
- 71 Legacy PCI Errors
- 73 System BIOS Events
- 73 System Events
- 73 System Boot
- 73 Timestamp Clock Synchronization
- 74 System Firmware Progress (Formerly Post Error)
- 75 System Firmware Progress (Formerly Post Error) – Next Steps
- 81 Chassis Subsystem
- 81 Physical Security
- 81 Chassis Intrusion
- 81 LAN Leash Lost
- 83 FP (NMI) Interrupt
- 83 FP (NMI) Interrupt – Next Steps
- 84 Button Press Events
- 85 Miscellaneous Events
- 85 IPMI Watchdog
- 87 SMI Timeout
- 87 SMI Timeout – Next Steps
- 88 System Event Log Cleared
- 88 System Event – PEF Action
- 89 System Event – PEF Action – Next Steps
- 90 Hot Swap Controller Events
- 90 HSC Backplane Temperature Sensor
- 91 HSC Drive Slot Status Sensor
- 92 HSC Drive Slot Status Sensor – Next Steps
- 92 HSC Drive Presence Sensor
- 93 HSC Drive Presence Sensor – Next Steps
- 95 Manageability Engine (ME) Events
- 95 Node Manager Exception Event
- 96 Node Manager Exception Event – Next Steps
- 96 Node Manager Health Event
- 97 Node Manager Health Event – Next Steps
- 98 Node Manager Operational Capabilities Change
- 99 Node Manager Operational Capabilities Change – Next Steps
- 100 Node Manager Alert Threshold Exceeded
- 101 Node Manager Alert Threshold Exceeded – Next Steps
- 101 ME Firmware Health Event
- 102 ME Firmware Health Event – Next Steps
- 103 Microsoft Windows* Records
- 103 Boot-up Event Records
- 104 Shutdown Event Records
- 107 Bug Check / Blue Screen Event Records
- 109 Linux* Kernel Panic Records