System Event Log Troubleshooting Guide for Intel
®
Sensor Cross Reference List
Sensor
Number
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
Sensor Name
Drive Slot 7 Status
Drive Slot 0 Presence
Drive Slot 1 Presence
Drive Slot 2 Presence
Drive Slot 3 Presence
Drive Slot 4 Presence
Drive Slot 5 Presence
Drive Slot 6 Presence
Drive Slot 7 Presence
Details Section
Next Steps
HSC Drive Slot Status Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
HSC Drive Presence Sensor – Next Steps
3.5 Node Manager / ME Firmware owned Sensors (GID = 002Ch or 602Ch)
The following table can be used to find the details of sensors owned by the Node Manager / Management Engine (ME) firmware.
Table 9: Management Engine Firmware owned Sensors
Sensor
Number
17h
18h
19h
1Ah
1Bh
Sensor Name
ME Firmware Health Events
Node Manager Exception Events
Node Manager Health Events
Node Manager Operational Capabilities
Change Events
Node Manager Alert Threshold Exceeded
Events
Details Section Next Steps
ME Firmware Health Event – Next Steps
Node Manager Exception Event – Next Steps
Node Manager Health Event – Next Steps
Node Manager Operational Capabilities Change
Node Manager Operational Capabilities Change – Next Steps
Node Manager Alert Threshold Exceeded
Node Manager Alert Threshold Exceeded – Next Steps
Revision 1.1 Intel order number G74211-002 15
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 Introduction
- 11 Purpose
- 11 Industry Standard
- 11 Intelligent Platform Management Interface (IPMI)
- 12 Baseboard Management Controller (BMC)
- 13 Intelligent Power Node Manager Version
- 14 Basic Decoding of a SEL Record
- 14 Default Values in the SEL Records
- 18 Sensor Cross Reference List
- 18 BMC owned Sensors (GID = 0020h)
- 22 BIOS POST owned Sensors (GID = 0001h)
- 22 BIOS SMI owned Sensors (GID = 0033h)
- 24 Hot Swap Controller Firmware owned Sensors (GID = 00C0h/00C2h)
- 25 Node Manager / ME Firmware owned Sensors (GID = 002Ch or 602Ch)
- 26 Microsoft* OS owned Events (GID = 0041)
- 26 Linux* Kernel Panic Events (GID = 0021)
- 27 Power Subsystems
- 27 Voltage Sensors
- 31 Power Unit
- 31 Power Unit Status Sensor
- 32 Power Unit Redundancy Sensor
- 34 Power Supply
- 34 Power Supply Status Sensors
- 35 Power Supply AC Power Input Sensors
- 36 Power Supply Current Output % Sensors
- 37 Power Supply Temperature Sensors
- 39 Cooling Subsystem
- 39 Fan Sensors
- 39 Fan Speed Sensors
- 40 Fan Presence and Redundancy Sensors
- 43 Temperature Sensors
- 43 Regular Temperature Sensors
- 45 Thermal Margin Sensors
- 46 Processor Thermal Control % Sensors
- 47 Discrete Thermal Sensors
- 49 Processor Subsystem
- 49 Processor Status Sensor
- 50 Catastrophic Error Sensor
- 51 Catastrophic Error Sensor – Next Steps
- 51 CPU Missing Sensor
- 52 CPU Missing Sensor – Next Steps
- 52 QuickPath Interconnect Error Sensors
- 52 QPI Correctable Error Sensor
- 53 QPI Non-Fatal Error Sensor
- 54 QPI Fatal and Fatal
- 56 Memory Subsystem
- 56 Memory RAS Mirroring and Sparing
- 56 Mirroring Configuration Status
- 57 Mirrored Redundancy State Sensor
- 59 Sparing Configuration Status
- 60 Sparing Redundancy State Sensor
- 63 ECC and Address Parity
- 63 Memory Correctable and Uncorrectable ECC Error
- 65 Memory Address Parity Error
- 68 PCI Express* and Legacy PCI Subsystem
- 68 PCI Express* Errors
- 68 PCI Express* Correctable Errors
- 69 PCI Express* Fatal Errors
- 71 Legacy PCI Errors
- 73 System BIOS Events
- 73 System Events
- 73 System Boot
- 73 Timestamp Clock Synchronization
- 74 System Firmware Progress (Formerly Post Error)
- 75 System Firmware Progress (Formerly Post Error) – Next Steps
- 81 Chassis Subsystem
- 81 Physical Security
- 81 Chassis Intrusion
- 81 LAN Leash Lost
- 83 FP (NMI) Interrupt
- 83 FP (NMI) Interrupt – Next Steps
- 84 Button Press Events
- 85 Miscellaneous Events
- 85 IPMI Watchdog
- 87 SMI Timeout
- 87 SMI Timeout – Next Steps
- 88 System Event Log Cleared
- 88 System Event – PEF Action
- 89 System Event – PEF Action – Next Steps
- 90 Hot Swap Controller Events
- 90 HSC Backplane Temperature Sensor
- 91 HSC Drive Slot Status Sensor
- 92 HSC Drive Slot Status Sensor – Next Steps
- 92 HSC Drive Presence Sensor
- 93 HSC Drive Presence Sensor – Next Steps
- 95 Manageability Engine (ME) Events
- 95 Node Manager Exception Event
- 96 Node Manager Exception Event – Next Steps
- 96 Node Manager Health Event
- 97 Node Manager Health Event – Next Steps
- 98 Node Manager Operational Capabilities Change
- 99 Node Manager Operational Capabilities Change – Next Steps
- 100 Node Manager Alert Threshold Exceeded
- 101 Node Manager Alert Threshold Exceeded – Next Steps
- 101 ME Firmware Health Event
- 102 ME Firmware Health Event – Next Steps
- 103 Microsoft Windows* Records
- 103 Boot-up Event Records
- 104 Shutdown Event Records
- 107 Bug Check / Blue Screen Event Records
- 109 Linux* Kernel Panic Records