ProFlow S-100 SA-Eliminator 48, SA-Eliminator 70, SA-Eliminator 90 water softener Installation, Opeeration, and Maintenance Manual
जाहिरात
जाहिरात
Models: SA-Eliminator 48 S-100
SA-Eliminator 70 S-100
SA-Eliminator 90 S-100
S-100
Installation, Opeeration, and Maintenance Manual
MODEL:
Operating Temperature:
Operating Pressure:
Voltage:
Rated Service Flow:
Rated Softening Capacity:
(Grains / Pounds of Salt)
Max Flow Rate to Drain:
SA-ELIMINATOR 48 S-100 Water Softener
Amount of High Capacity Resin:
Rated Efficiency:
34 o
–120 o
F
25–125 psi
110V 60 cycles
12.1 GPM @ 13 psi drop
31,200 @ 7.5; 41,900 @
15.2; 47,600 @ 21.2
4.3 GPM
1.5 ft
3
4,170 grains @ 7.5 lbs
**Observe all state and local plumbing codes.
**The efficiency of the softener is valid only at the stated salt dosage.
**This softener conforms to WQA S-100 for the specifically claimed performance.
Manufactured By:
R&M Manufacturing
28 South 1550 West
Lindon UT 84042-1617
(801) 785-5557
CAUTION: Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
pn: LBL-ELIM-48-CERT
MODEL:
Operating Temperature:
Operating Pressure:
Voltage:
Rated Service Flow:
Rated Softening Capacity:
(Grains / Pounds of Salt)
Max Flow Rate to Drain:
Amount of High Capacity Resin:
Rated Efficiency:
SA-ELIMINATOR 90 S-100 Water Softener
34 o
–120 o
F
25–125 psi
110V 60 cycles
18.0 GPM @ 15 psi drop
37,400 @ 8.8; 65,800
@ 25.3; 74,700 @ 35.3
4.1 GPM
2.5 ft
3
4,280 grains @ 8.8 lbs
**Observe all state and local plumbing codes.
**The efficiency of the softener is valid only at the stated salt dosage.
**This softener conforms to WQA S-100 for the specifically claimed performance.
Manufactured By:
R&M Manufacturing
28 South 1550 West
Lindon UT 84042-1617
(801) 785-5557
CAUTION: Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
pn: LBL-ELIM-90-CERT
MODEL:
Operating Temperature:
Operating Pressure:
Voltage:
Rated Service Flow:
Rated Softening Capacity:
(Grains / Pounds of Salt)
Max Flow Rate to Drain:
SA-ELIMINATOR 70 S-100 Water Softener
Amount of High Capacity Resin:
Rated Efficiency:
34 o
–120 o
F
25–125 psi
110V 60 cycles
15.5 GPM @ 15 psi drop
48,000 @ 11.5; 64,400
@ 23.3; 73,100 @ 32.5
4.6 GPM
2.3 ft
3
4,170 grains @ 11.5 lbs
**Observe all state and local plumbing codes.
**The efficiency of the softener is valid only at the stated salt dosage.
**This softener conforms to WQA S-100 for the specifically claimed performance.
Manufactured By:
R&M Manufacturing
28 South 1550 West
Lindon UT 84042-1617
(801) 785-5557
CAUTION: Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
pn: LBL-ELIM-70-CERT
R&M Water Group
28 South 1550 West
Lindon, Utah 84042
P: (801) 785-5557
F: (801) 785-7823
© 2004 R&M Water Group All rights reserved.
ProFlow Eliminator is a registered trademark of R&M Water Group pn: L-R-ProFlow-OM | rev: 02/04
Table of Contents
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Water Line Connection
Overfl ow Line Connection
Placing Conditioner into Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ProFlow 460i Series Control Se ings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Programming
Calendar Override Se ing
Common Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Salt Dial Adjustment
Removing the Valve Assembly for Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Controller Se ing for Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Injector Screw and Injector
Specifi cations: Control Valve AUV-268-460i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Pressure Graphs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Identifi cation of Control Valving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Valve Disc Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Flow Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Replacement Parts AUV-1053832 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Disinfection of Water Conditioners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Sodium or Calcium Hypochlorite
ProFlow Eliminator | 3 |
Installation
All plumbing and electrical connections must conform to local codes.
Inspect unit carefully for carrier shortage or shipping damage.
This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or a er the system.
The most common bypass systems are the Autotrol Series 1265 bypass valve (1) and plumbed-in globe valves (2). Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation.
In
Not in Bypass
Out In
In Bypass
Out
Water Line Connection
The installation of a bypass valve system is recommended to provide for occasions when the water conditioner must be bypassed for hard water or for servicing.
S
S
B
S
S
B
SS PA
BY
SS PA
BY
Location Selection
1. The distance between the unit and a drain should be as short as possible.
2. If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available.
3. Since salt must be added periodically to the brine tank, the location should be easily accessible.
4. Do not install any unit closer to a water heater than a total run of 10 feet (3 m) of piping between the outlet of the conditioner and the inlet to the heater. Water heaters can sometimes overheat to the extent they will transmit heat back down the cold pipe into the unit control valve.
Hot water can severely damage the conditioner. A 10foot (3-m) total pipe run, including bends, elbows, etc., is a reasonable distance to help prevent this possibility.
A positive way to prevent hot water fl owing from heat source to the conditioner, in the event of a negative pressure situation, is to install a check valve in the so water piping from the conditioner.
If a check valve is installed, make certain the water heating unit is equipped with a properly rated temperature and pressure safety relief valve. Also, be certain that local codes are not violated.
5. Do not locate unit where it or its connections
(including the drain and overfl ow lines) will ever be subjected to room temperatures under 34 o F (1 o C) or over 120 o F (49 o C).
6. Do not install unit near acid or acid fumes.
7. The use of resin cleaners in an unvented enclosure is not recommended.
Water Conditioner Water Conditioner
Figure 1
: Autotrol Series 1265 bypass valve
Drain Line Connection
Note: Standard commercial practices are expressed here. Local codes may require changes to the following suggestions.
1. Ideally located, the unit will be above and not more than 20 feet (6.1 m) from the drain. For such installations, using an appropriate adapter fi ing, connect 1/2-inch (1.3-cm) plastic tubing to the drain line connection of the control valve.
2. If the backwash fl ow rate exceeds 5 gpm
(22.7 Lpm) or if the unit is located more than 20 feet
(6.1 m) from drain, use 3/4-inch (1.9-cm) tubing for runs up to 40 feet (12.2 m). Also, purchase appropriate fi ing to connect the 3/4-inch tubing to the 3/4-inch
NPT drain connection.
3. If the unit is located where the drain line must be elevated, you may elevate the line up to 6 feet
(1.8 m) providing the run does not exceed
15 feet (4.6 m) and water pressure at conditioner is not less than 40 psi (2.76 bar). You may elevate an additional 2 feet (61 cm) for each additional
10 psi (0.69 bar).
4. Where the drain line is elevated but empties into a drain below the level of the control valve, form a
7-inch (18-cm) loop at the far end of the line so that
| 4 | ProFlow Eliminator
the bo om of the loop is level with the drain line connection. This will provide an adequate siphon trap.
5. Where the drain empties into an overhead sewer line, a sink-type trap must be used.
IMPORTANT
: Never insert drain line into a drain, sewer line or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner.
Note
: Standard commercial practices have been expressed here. Local codes may require changes to these suggestions.
1” Air Gap
Right Way
Overflow Line Connection
In the absence of a safety overfl ow and in the event of a malfunction, the BRINE TANK OVERFLOW will direct
“overfl ow” to the drain instead of spilling on the fl oor where it could cause considerable damage. This fi ing should be on the side of the cabinet or brine tank.
To connect overfl ow, locate hole on side of brine tank.
Insert overfl ow fi ing (not supplied) into tank and tighten with plastic thumb nut and gasket as shown (4). A ach length of 1/2-inch (1.3-cm) I.D. tubing (not supplied) to fi ing and run to drain. Do not elevate overfl ow line higher than 3 inches (7.6 cm) below bo om of overfl ow fi ing. Do not tie into drain line of control unit. Overfl ow line must be a direct, separate line from overfl ow fi ing to drain, sewer or tub. Allow an air gap as per drain line instructions (2).
Overflow
Fitting Installed
Brine Tank
Figure 2
: Drain line with air gap
Brine Line Connection
It will be necessary to install the brine line to the brine fi ing on the valve (3/8-inch NPT).
Be sure all fi ings and connections are tight.
Connect 1/2-inch (1.3 cm)
Tubing or Hose and Run to Drain.
Figure 3
: Overfl ow fi ing
Drain Line
Incoming
To House
Overflow
Caution!
Do NOT connect coverfl ow and drainline. Brine tank overfl ow will occur.
1" Air Gap
Figure 4
: Eliminator drain and overfl ow layout
ProFlow Eliminator | 5 |
Placing Conditioner into
Operation
A er all previous steps have been completed, the unit is ready to be placed into operation. Follow these steps carefully.
1. Remove control valve cover by fi rst releasing the plastic clip from the back of the cover. Pull back of cover slightly outward and li up.
Note: The following steps will require turning the indicator knob ( and ) to various positions. Manually rotate the camsha
COUNTERCLOCKWISE
only until indicator knob points to desired position. (See manual regeneration sections for each control’s manual operation.)
2. Rotate indicator knob
COUNTERCLOCKWISE
until it points directly to the word
BACKWASH
.
3. Fill media tank with water.
a. With water supply off , place the bypass valve(s) into the “not in bypass” position.
b. Open water supply valve very slowly to approximately the 1/4 open position.
IMPORTANT
: If opened too rapidly or too far, media may be lost. In the 1/4 open position, you should hear air escaping slowly from the drain line.
c. When all of the air has been purged from the tank
(water begins to fl ow steadily from the drain), open the main supply valve all the way.
d. Allow water to run to drain until clear.
about fi ve minutes. This will allow all trapped air to escape from the tank.
4, Add water to brine tank (initial fi ll).
With a bucket or hose, add approximately
4 gallons (15 liters) of water to brine tank. If the tank has a salt platform above the bo om of the tank, add water until the level is approximately 1 inch (25 mm) above the platform.
5 Place the conditioner into operation.
a. With the water supply valve completely open, carefully advance the indicator knob
COUNTERCLOCKWISE
to the center of the
BRINE REFILL
position. Hold at this position until water starts to fl ow through the brine line into the brine tank. Do not run for more than one or two minutes.
b. Advance the indicator knob
COUNTERCLOCKWISE
until it points to the center of the
BRINE/SLOW RINSE
position.
c. With the conditioner in this position, check to see if water is being drawn from the brine tank.
The water level in the brine tank will recede very slowly. Observe water level for at least three minutes. If the water level does not recede, or if it goes up, reference the
Troubleshooting
section.
d. Advance the indicator knob
COUNTERCLOCKWISE
to the
SERVICE
position and run water from a nearby faucet until the water is clear and so .
Electrical Connection
100 VAC, 115 VAC, and 230 VAC units
: Remove twist tie from the power cord and extend cord to its full length.
Make sure power source matches the rating printed on the control. Be certain a wall switch does not control the outlet.
12 VAC
: Connect the plug of the transformer (supplied) secondary cable to the mating socket at the rear or bo om of the timer housing. Be certain the transformer is secure and is plugged into a power source of correct voltage that is not controlled by a wall switch.
Ion Exchange
Cation resin is used to create the ion-exchange process wherein dissolved minerals are removed and replaced with sodium ions.
| 6 | ProFlow Eliminator
Pro Flow 460i Series
Control Settings
ProFlow 460i Control
Water-Flow Indicator
Hour Time Display
PM Indicator
Access Door
Raised Tab
Jumper
Spare Jumper
Indicator Knob
Timer Locking Pin
Time-Set Button
Transformer Plug Receptable
Programming
Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control.
Open the access door by pushing the raised tab on the door toward the le while pulling the tab out (5).
Time-of-Day Setting
With the jumper on the set of pins next to the word TIME
(6), set the time of day to the closest hour by pressing the black TIME SET bu on. PM hours are indicated by a light next to the le ers PM on the display window.
Note
: The use of a small needle-nose pliers will aid in moving the jumper.
Note
: The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set the current time of day accordingly (e.g., to have the unit regenerate at
4:00 a.m.—two hours later—set the clock two hours earlier than the actual time of day).
Note
: The Timer Locking Pin should always be horizontal
(5) during operation.
ProFlow Eliminator | 7 |
Hardness Setting
Move the jumper to the set of pins next to the word
HARDNESS (8). Press the black TIME SET bu on until the hardness of the incoming water supply is displayed. The hardness range is from 1 to 99 grains per gallon.
To change water hardness stated in parts per million
(PPM) to grains per gallon (GPG) use this formula:
17.1
4. Depress the black TIME SET bu on. The numbers will roll from “0” to “15.” Release the switch at the desired number of days for the calendar override. For example, releasing the switch at “10” would program a 10-day calendar override.
6. Place jumper back on TIME and reconnect power.
7. The calendar override program is maintained during power outages by the NOVRAM circuitry.
8. To remove the calendar override, follow the same steps above and program back to “0.”
Figure 6 Figure 8 Figure 9
Capacity Setting
Move the jumper to the set of pins next to the word
CAPACITY (9). Press the black TIME SET bu on until the correct capacity value is displayed. The capacity range is 1 to 99 kilograins. Refer to the Suggested Salt Dial Se ings table (8).
Return the jumper to the top set of pins next to the word
TIME and replace the access door.
The jumper must
NOT be le on any pins other than the top pair next to the word TIME
. Otherwise, the unit may show a blank display.
Note: A spare jumper is located on the bo om set of pins.
In the event that the hardness or capacity se ing must be changed, simply follow the appropriate steps described above.
Common Features
Salt Dial Adjustment
These models may be adjusted to produce maximum to minimum conditioning capacities by se ing the salt dial, which controls the amount of salt used per regeneration.
When desired, the minimum se ing may be used on installations if the frequency of regeneration is increased to compensate for lower regenerated conditioning capacity. The installing dealer will set the unit for proper salt usage. Further adjustments are needed only if the hardness of the water supply changes or if water use changes dramatically. Capacity will need to be adjusted accordingly.
To adjust salt dosage, insert a small screwdriver into the white indicator knob and move pointer to proper salt se ing (Figure 10).
Note
: To convert the salt se ings from English to metric, divide by 2.2 (e.g., 12 pounds ³ 2.2 = 5.5 kg of salt).
Calendar Override Setting
2. Place jumper on Pin A and reconnect power.
3. Move jumper to Pin B. A zero will appear, indicating zero days of calendar override. All controllers are preprogrammed in this manner at the manufacturer.
Note
: System comes pre-programmed with default hardness, capacity and corresponding salt se ings. Refer to table 1 for default se ings.
Indicator Knob
Figure 9
: Indicator Knob
| 8 | ProFlow Eliminator
Model
Capacity
Se ing
Default
Salt Se ing
48 31,200 gr 7.5 lbs
70 48,000 gr 11.5 lbs
90 37,400 gr 8.8 lbs
Table 1
: Default salt se ing, by model
Model
48
70
90
Table 2
Max Flow
Rate
Pressure Drop @
Max Flow
12.1 gpm
15.5 gpm
18.0 gpm
13.0 psi
15.0 psi
15.0 psi
Exchange
Media
1.5
3
2.3
3
2.5
3
: Flow rates and pressure loss
Max Flow to Drain
(Regeneration)
2.5 gpm
3.5 gpm
4.0 gpm
Model
Tot. Gr.
Recovr’d
Gr.
Recov’rd p/ Salt lb
High-
Eff . Salt
Se ing
48 31,200 gr 4,160.0 gr 7.5 lbs
70 48,000 gr 4,170.0 gr 11.5 lbs
90 37,400 gr 4,200.0 gr 8.8 lbs
Tot. Gr.
Recovr’d
Gr.
Recovr’d p/ Salt lb
Mid-
Eff . Salt
Se ing
41,900 gr 2,756.6 gr 15.2 lbs
64,400 gr 2,763.9 gr 23.3 lbs
65,800 gr 2,600.8 gr 25.3 lbs
Tot. Gr.
Recovr’d
Gr.
Recovr’d p/ Salt lb
Low-
Eff . Salt
Se ing
47,600 gr 2,245.3 gr 21.2 lbs
73,100 gr 2,249.2 gr 32.5 lbs*
74,700 gr 2,116.1 gr 35.3 lbs*
Table 3
: Effi
* Extra salt cam: divide the suggested se ing by 2 to accomplish salt se ing.
Note: Use any good grade rock salt (NaCl) to obtain rated capacities.
The amount of salt placed in the brine tank has nothing to do with the amount of salt used during the regeneration cycle. Water will dissolve and absorb salt only until it becomes saturated. A given amount of brine (saltsaturated water) contains a specifi c amount of salt. The salt dial controls the amount of brine used during the regeneration cycle (e.g., when set at
15 pounds (6.8 kg) the amount of brine the conditioner will use for each regeneration will contain 15 pounds
(6.8 kg) of salt, etc.)
Never let the amount of salt in the brine tank be lower than the normal liquid level. Do not overload the brine tank with salt.
Manual Regeneration
Electricity is used only to run the control and to rotate the camsha . All other functions are operated by water pressure. Therefore, in the event of a power outage, all the regeneration positions may be dialed manually by depressing the indicator knob and turning
COUNTERCLOCKWISE
( and ). The following cycle times should be used for proper regeneration:
BACKWASH
—14 minutes
BRINE/SLOW RINSE
—52 minutes
FAST RINSE/REFILL
—10 minutes
PURGE
—6 minutes
Do not exceed 10 minutes for the
FAST RINSE/REFILL
cycle as this will cause excessive salt usage during the next regeneration and possibly a salt residue in the so ened water.
Guest Cycle
When abnormally high water usage exhausts your water conditioner’s capacity ahead of schedule, an extra regeneration can be achieved. Depress the indicator knob on the 440i (5) with a wide-blade screwdriver and turn
COUNTERCLOCKWISE
to
START
to initiate a regeneration. For the 460i, simply depress the indicator knob (5). It will take a few minutes for regeneration to start. A normal regeneration will take approximately two hours.
So ener conforms to WQA S-100 for the specifi c performance claims as verifi ed and substantiated by test data.
ProFlow Eliminator | 9 |
Removing the Valve
Assembly for Servicing
1. Unplug the power cord.
bypass position.
3. Remove cover and with screwdriver, relieve tank pressure by pushing open valve No. 7 (rear fl apper) on control as shown (Figure 11).
4. When used with a globe valve bypass, loosen and detach the inlet, outlet, brine and drain lines from the valve. If using the bypass, loosen and remove valve from bypass as well as loosening and removing the brine and drain lines.
5. Unscrew valve (counterclockwise) and remove valve from tank.
6. To replace the control valve, reverse the above procedure.
Controller for Servicing
1. Unplug the power cord.
3. Align the indicator arrow on the rear of the camsha with the top of the rear hoop of the top plate (Figure
12).
Indicator Arrow
Figure 12
: Top-down view of valve
4. Remove the camsha by carefully pushing the securing tab, located at the rear of the camsha , away from the camsha until the tab disengages from the camsha . Push the back of the camsha down and out to the inlet side of the valve (Figure 13).
Figure 11
: Valve assembly
Figure 13
: Removing the camsha
5. Disengage the front of the camsha from the output gear of the control.
6. Remove the timer locking pin and li the control straight up and off of the valve.
7. To reinstall the camsha and control, reverse the above procedures.
| 10 | ProFlow Eliminator
Preventive Maintenance
Injector Screen and Injector
Inspect and clean brine tank and screen fi lter on end of brine pickup tube once a year or when sediment appears in the bo om of the brine tank.
Clean injector screen and injector once a year:
1. Unplug the wall-mount transformer.
bypass position.
3. Relieve system pressure by opening valve No. 7
(at rear) with a screwdriver (Figure 11).
4. Using a screwdriver, remove injector screen and injector cap (Figure 14).
5. Clean screen using a fi ne brush. Flush until clean.
6. Using a needle-nose pliers, pull injector straight out.
7. Flush water into the injector screen recess of the valve body to fl ush debris out through the injector recess.
8. Clean and fl ush the injector.
9. Lubricate the O-rings on the injector, injector cap and injector screen with silicone lubricant
only
!
10. Reinstall the injector, injector cap and injector screen.
IMPORTANT
: Do not overtighten the plastic cap. Seat the cap lightly into position. Overtightening may cause breakage of the plastic cap that may not be immediately evident.
11. Plug the wall-mount transformer into outlet; reset clock if necessary.
12. Slowly open water supply valve or return bypass valve(s) to the “service” position.
Water Meter Maintenance
Note
: A water meter is used only with the 460i control.
If you are using the 440i control, this section does not pertain to your conditioner.
The metering device used with the 460i demand control may require simple maintenance. In rare instances, the turbine wheel of the water meter can collect small particles of oxidized iron, eventually preventing the wheel from turning.
into the bypass position.
2. Relieve pressure by opening the Backwash Drain
Valve (the seventh back from the control) with a screwdriver (Figure 11).
3. Loosen and remove the pipe/tube adapters or 1265 bypass from the inlet and outlet of the valve body.
4. Using a needle-nose pliers, remove the turbine from the outlet housing. Grasp one of the four vanes of the outer gland and pull straight out to remove turbine assembly from the outlet of the valve (Figure 14).
5. Carefully remove the turbine wheel from the housing.
Use a toothbrush to lightly scrub the iron off the magnet. Iron buildup on the surfaces can be removed by soaking the wheel in a mild sodium hydrosulfi te
(such as RoVer*) solution for a few minutes. Flush thoroughly with water.
6. Carefully reinstall the turbine wheel into the turbine cage housing. Make sure that the sha of the wheel seats into the bearing of the cage. Reassemble the turbine cage and check that the wheel rotates freely.
7. Reinstall the turbine cage into the outlet of the valve.
8. Reinstall the pipe/tube adapters or 1265 bypass to the inlet and outlet of the valve.
9. Turn on the water supply or put the bypass valve(s) into the service position and purge the air out of the system.
To check for proper meter operation, open a downstream faucet and observe the water fl ow indication on the control display.
*RoVer is a trademark of Hach Chemical Company.
Figure 14
: Removing injector screen and injector cap
ProFlow Eliminator | 11 |
Specifications: Control Valve AUV - 268-460i
Hydrostatic Test Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (20.69 bar)
Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-125 psi (1.38 - 8.62 bar)
Standard Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 60 Hz
Optional Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 50 Hz, 230V 50 Hz, 200V 60 Hz, 24V 60 Hz, 24V 50 Hz,
100V 60 Hz, 100V 50 Hz, 12V 50 Hz/transformer, 12V 60 Hz/transformer
Electrical Cord (standard rating) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 inch (1.5 m) 3-wire with plug
Pressure Tank Thread. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1/2 inch-8 male
Riser Pipe Diameter Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 inch OD (26.7 mm)
Riser Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/8 ±1/8 inches (31.8 mm) higher than the top of mineral tank
Standard Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-inch (25.4-mm) copper tube adapters
Optional Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4-inch, 22-mm, and 28-mm copper tube adapters
1 1/4-inch copper
3/4-inch, 1-inch, 25-mm CPVC tube adapters
Brine Line Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8-inch NPT male
Drain Line Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4-inch NPT male
Optional Bypass Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotating handles, full 1-inch porting, reinforced Noryl
Control Module, Tank Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reinforced Noryl
Rubber Goods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compounded for cold water service
Program Clock (Timer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460i: Available in English
Brine Refill Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 10 lbs (0.45 to 4.5 kg) of salt or 3 to 19 lbs (1.4 to 8.6 kg) of salt
Injector Size “A” White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle 042-inch (1.1-mm) diameter, Throat .089-inch (2.3-mm) diameter
Injector Size “B” Blue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle .052-inch (1.3-mm) diameter, Throat .099-inch (2.5-mm) diameter
Injector Size “C” Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle .059-inch (1.5-mm) diameter, Throat .099-inch (2.5-mm) diameter
Injector Size “D” Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle .071-inch (1.8-mm) diameter, Throat .147-inch (3.7-mm) diameter
Internal Backwash Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- through 14-inch (17.8- though 35.6-cm) diameter media tanks
All sizes to flow 4.5 gpm/sq ft (183 L/m/m2) of bed area.
For tank sizes above 14 inches in diameter, use an external flow control.
| 12 | ProFlow Eliminator
Specifications: Control Valve AUV - 268-460i
0.20
0.15
0.10
0.05
0.00
Injector #1031363
"A" in a 268 Valve
1.00
Total
0.75
0.50
Rinse
Brine Draw
0.25
0.00
20 40 60 80 100 120
PSI
400 600 800 1000 1200 1400 1600 1800
bar
0.30
0.25
0.20
0.15
0.10
0.05
0.00
Injector #1031364
"B" in a 268 Valve
1.25
1.00
0.75
0.50
0.25
Total
Rinse
Brine Draw
0.00
20 40 60 80 100 120
PSI
400 600 800 1000 1200 1400 1600 1800
bar
0.20
0.15
0.10
0.05
0.00
Injector #1031365
"C" in a 268 Valve
1.75
1.50
1.25
1.00
0.75
Total
Rinse
0.50
0.25
Brine Draw
0.00
20 40 60 80 100 120
PSI
400 600 800 1000 1200 1400 1600 1800
bar
Backwash Number
48
10
Model
70
12
Flow* (gpm)
2.5
3.5
Flow* (lpm)
9.5
13.2
* Approximate fl ow rates at 60 psi (4.14 bar).
90
12
3.5
13.2
Injector #1030272
"D" in a 268 Valve
0.30
0.25
0.20
0.15
0.10
0.05
0.00
2.25
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0.00
Total
Rinse
Brine Draw
20 40 60 80 100 120
PSI
400 600 800 1000 1200 1400 1600 1800
bar
ProFlow Eliminator | 13 |
Identification of
Control Valving
Backwash Drain Valves (7)
Inlet Valve (3)
Brine Valve (1)
Refill Valve (5)
Valve Disc
Principle of Operation
Cam
Valve Disc
Rinse Drain Valve (6)
Outlet Valve (4)
Bypass Valve (2)
Valve Seat
Valve Disc Closed Valve Disc Open
Flow Diagrams
Service Position Backwash Position
Valve Position
1 Closed
2 Closed
3 Open
4 Open
5 Closed
6 Closed
7 Closed
| 14 | ProFlow Eliminator
Valve Position
1 Closed
2 Open
3 Closed
4 Open
5 Closed
6 Closed
7 Open
Brining / Slow-Rinse Position Purge Position
Valve Position
1 Closed
2 Closed
3 Open
4 Open
5 Open
6 Closed
7 Closed
Brine Refine Position
Valve Position
1 Closed
2 Open
3 Open
4 Closed
5 Closed
6 Open
7 Closed
Valve Position
1 Closed
2 Closed
3 Open
4 Open
5 Open
6 Closed
7 Closed
ProFlow Eliminator | 15 |
Replacement Parts AUV - 1053832
ProFlow: High-Flow Eliminator Series
12
8
6 3
7
5
6
3
4
2a
2b
Parts List
Code
1
Part # Description
AUV-1053832 Control Valve (Complete)
Valve Assembly, w/o Flow Con trols
(460i)
1
Qty
Camshaft: (all models) 1
AVP-1035627 Extra Salt Cam (for model 90 only) 1
AVP-1031391 Timer Locking Pin
Drain Control Assembly
AVP-1000212 No. 10 (2.5 gpm; 9.5 Lpm)
1
1
AVP-1000213 No. 12 (3.5 gpm; 13.2 Lpm)
AVP-1030502 Ball, Flow Control 2
1 Injector Assembly:
AVP-1032970 “A” Injector - White
AVP-1032971 “B” Injector - Blue
AVP-1032972 “C” Injector - Red
AVP-1030272 “D” Injector - Green
Injector Cap Assembly
AVP-1000217 “A” Cap
AVP-1000218 “B” Cap
AVP-1000219 “C” Cap
AVP-1030303 “D” Cap
1
8
Code Part # Description
Brine Refill Control (460i)
AVP-1034261 1 to 10 Pounds Salt
9
AVP-1034263 3 to 19 Pounds Salt
AVP-1002449 Drain Fitting Elbow (3/4” hose barbed)
AVP-1000226 Screen/Cap Assembly 10
11
12
13
AVP-1010429 O-Ring
AVP-1035622 Tank Ring
Plumbing Adapter Kits:
Turbine Assembly (460i only)
AVP-1033444 Meter
AVP-1001580 Spring, Flapper Valve
14
15
* Valve Disc Kit
AVP-1041174 Standard
AVP-1041175 Severe Service
* AVP-1000062
* Not Shown
I-Lid Cover
** Soft water refill is not available with the extra salt cam.
1
1
1
1
1
1
1
Qty
1
| 16 | ProFlow Eliminator
Replacement Parts: Distributor Assembly
All Models (48, 70, and 90)
4,5
1
2
DST-2001: High-Flow
Upper Distributor
Code #6: DST-1021-E: High-Flow Distributor
Code #4: Eliminator
Cap Number
JKT-1220
JKT-1165
JKT-1095
Eliminator 48
JKT-1115
Eliminator 70
JKT-1180
Eliminator 90
JKT-1233
Code #5: Eliminator Jacket Numbers
3
7
9
11
14
13
10
6
15
12
8
SA-Eliminator 48, 70, and 90 (S-100)
Code
1
Part #
AUV-1053832
Description
268/460i Meter 1
2 AVP-1000062 I-Lid Cover, 255, 268 1
48
Qty
3 DST-2000 Top Dist. Bajonet
4 See options (left)
1
5 See options (left)
6 See drawing (upper left)
78 lbs
7 MDA-1000
8 BTC-1210
9 BTC-1000
10 BTC-1114
11 BTC-1306
12 BTC-1037
13 BTC-1033
14 BTC-1036
HCR Cation Resin
BT 1840 Blk
2 PC Overflow Set
Brine Well 4x36 Slot
Cap 4"
Air Check, 3/8"
474 Brine Valve 3/8"
474 Float
1
1
1
1
2
1
1
15 MTK-SP-1044 Tank: 10"x44"
MTK-SP-1248 Tank: 12"x48"
MTK-SP-1447 Tank: 14"x47"
1
—
—
119 lbs
1
1
1
1
2
1
1
—
1
—
1
1
1
70
Qty
1
1
1
90
Qty
130 lbs
1
1
1
1
2
1
1
—
—
1
*Note: Drawing above is based on model 48. Larger models (70 and
90) increase case size respectively as seen at left.
ProFlow Eliminator | 17 |
460i Control
BP-A-1040930
Code #2
Code Part # Description
2 460i Control
3 AVP-1040930 1265 Bypass (see table at right)
* AVP-1000811 Transformer (460i):
* AVP-1000907 Transformer Extension Cord
15 feet (4.6 m)
* AVP-1034264 Y-Splitter (run 2 units from 1 transformer)
*Not shown.
1
1
1
1
Qty
1
BP-A-1001606
BP-A-1001670
BP-A-1001210
BP-A-1001613
BP-A-1001614
Bypass Kit
3/4" Copper Tail Kit
1" Copper Tail Kit
1 1/4" Copper Tail Kit
3/4" CPVC Tail Kit
1" CPVC Tail Kit
B Y PA S S
B Y PA S S
Code #3: Bypass
| 18 | ProFlow Eliminator
Troubleshooting
The technology upon which the control valve is based is well established and proven in service over many years.
However, should a problem or question arise regarding the operation of the system, the control can very easily be serviced. For parts mentioned, refer to exploded views in the
Replacement Parts
section of this manual.
IMPORTANT
: Service procedures that require the water pressure to be removed from the system are marked with
Valve Troubleshooting
a “
§
” a er the possible cause. To remove water pressure from the system, put the bypass valve or three-valve bypass into the bypass position and open the backwash drain valve (the seventh valve back from the control) with a screwdriver. Restore system water pressure when the service work is completed.
The problems outlined below are the most common occurances of problems. If you are unable to solve your problem with this manual, contact the manufacturer.
Problem
Control will not draw brine.
Possible Cause
Low water pressure.
Solution
Set pump to maintain 30 psi at conditioner.
Brine tank overflow.
Restricted drain line.
Injector plugged§
Injector defective§
Valve (2 and/or 4) not closed.
Uncontrolled brine refill flow rate§
Valve (3 or 4) not closed during brine draw causing refill.
Air leak in brine line.
System using more or less salt than salt control is set for.
Inaccurate setting.
Foreign matter in controller causing incorrect flow rates§
Intermittent or irregular brine draw.
Brine valve (1) being held open.
Defective controller.
Low water pressure.
Remove restriction.
Lean injector and screen.
Replace injector.
Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace if needed.
Manually operate valve stem to flush away obstruction.
Remove variable salt controller to clean.
Flush out foreign matter by holding disc open and manually operating valve stem.
Check all connections in brine line for leaks.
Refer to instructions.
Correct setting.
Remove variable salt controller and flush out foreign matter. Manually position control to brine draw to clean controller (after so doing, position control to “purge” to remove brine from tank).
Replace controller.
Set pump to maintain 30 psi at conditioner.
No conditioned water after regeneration.
Control backwashes at excessively low or high rate.
Flowing or dripping water at drain or brine line after regeneration.
Hard water leakage during service.
Defective injector§
Unit did not regenerate.
Replace both injector and injector cap.
Check for power.
No salt in brine tank.
Plugged injector§
Valve stem return spring on top plate weak.
Improper regeneration.
Add salt.
Clean injector. Flush with water.
Incorrect backwash controller used.
Replace with correct size controller.
Foreign matter affecting controller operation§ Remove controller and ball. Flush with water.
Drain valve (5 or 6) or brine valve (1) held open by foreign matter or particle.
Manually operate valve stem to flush away obstruction.
Replace spring.
Leaking of bypass valve§
Repeat regeneration making certain that the correct salt dosage is set.
Replace O-ring.
O-ring around riser tube damaged§
Replace O-ring.
§ This procedure requires removal of water pressure from the system.
ProFlow Eliminator | 19 |
460i Control Troubleshooting
Problem
Clock does not display time of day.
Clock does not display correct time of day.
Possible Cause
Transformer cord unplugged.
No electric power at outlet.
Defective transformer.
Defective circuit board.
Outlet operated by switch.
Incorrect voltage or frequency (Hz).
Time display continues to advance.
Time display shows something other than time of day.
Power outages.
Defective time set switch.
Electrical interference.
No water flow display when water is flowing.
Defective circuit board.
Bypass valve in bypass.
Meter probe disconnected or not fully connected to meter housing.
Restricted meter turbine rotation due to foreign matter in meter.
Control regenerates at wrong time of day.
Timer stalled in regeneration cycle.
Defective meter probe.
Defective circuit board.
Power outages.
Clock set incorrectly.
Motor dead.
Motor runs backward.
No electric power at outlet.
Broken gear.
Defective switch.
Air leak in brine connections.
Binding of camshaft.
Water pressure greater than 125 psi during regeneration.
Defective circuit board.
Continuous regeneration. Camshaft does not stop at the end of regeneration.
Broken switch activator on gear.
Defective switch.
§ This procedure requires removal of water pressure from the system.
Solution
Connect power.
Repair outlet or use working outlet.
Replace transformer.
Replace timer.
Use outlet not controlled by switch.
Replace timer with one of correct voltage and frequency (Hz).
Reset clock.
Replace timer.
Disconnect power to unit. Restore power and reset time of day
Replace timer.
Shift bypass valve to not-in-bypass position.
Fully insert probe into meter housing.
Remove meter housing, free up turbine and flush with clean water. Do not disassemble turbine from meter housing. Turbine should spin freely. If not, replace meter§
Replace timer.
Replace timer.
Reset clock to correct time of day.
Reset clock to correct time of day.
Replace timer.
Replace timer.
Repair outlet or use working outlet.
Replace timer.
Replace timer.
Check all junction points and make appropriate corrections.
Remove foreign object obstruction from valve discs or camshaft.
Install pressure regulator§
Replace timer.
Replace timer.
Replace timer.
| 20 | ProFlow Eliminator
460i Control Troubleshooting (con't)
Problem
Control will not regenerate automatically or when button is pressed.
Control will not regenerate automatically but will regenerate when button is pressed.
Possible Cause
Electric cord unplugged.
No electric power at outlet.
Defective motor.
Broken gear.
Binding in gear train.
Defective switch.
If water flow display is not operative, refer to
Item 5
Defective circuit board.
Incorrect hardness and capacity settings.
Solution
Connect power.
Repair outlet or use working outlet.
Replace timer.
Replace timer.
Replace timer.
Replace timer.
Same as Item 5.
Run out of soft water between regenerations.
Improper regeneration.
Fouled softener resin.
Incorrect salt setting.
Incorrect harness or capacity settings.
Water hardness has increased.
Restricted meter turbine rotation due to foreign material in meter housing.
Replace timer.
Set to correct values. See Programming section.
Repeat regeneration, making certain that correct salt dosage is used.
Use resin cleaner. See Note 1.
Set salt control to proper level. See Salt Setting chart.
Set to correct values. See Programming section.
Set hardness to new value. See Programming section.
Remove meter housing, free us turbine and flush with clean water. DO NOT DISASSEMBLE
TURBINE FROM METER HOUSING. Turbine should spin freely, if not, replace meter§
Repair leaky plumbing and/or fixtures§ Excessive water usage below 1/5 gallon per minute.
§ This procedure requires removal of water pressure from the system.
Note: 1: Use of resin cleaners in an unvented enclosure is not recommended.
ProFlow Eliminator | 21 |
Disinfection of Water
Conditioners
The materials of construction of the modern water conditioner will not support bacterial growth, nor will these materials contaminate a water supply. However, the normal conditions existing during shipping, storage and installation indicate the advisability of disinfecting a conditioner a er installation, before the conditioner is used to treat potable water. In addition, during normal use, a conditioner may become fouled with organic ma er or in some cases with bacteria from the water supply.
Thus every conditioner should be disinfected a er installation, some will require periodic disinfection during their normal life, and in a few cases disinfection with every regeneration would be recommended.
Depending upon the conditions of use, the style of conditioner, the type of ion exchanger, and the disinfectant available, a choice can be made among the following methods.
Application
These materials are satisfactory for use with polystyrene resins, synthetic gel zeolite, greensand and bentonites.
5.25% Sodium Hypochlorite
These solutions are available under trade names such as Clorox Bleach*. If stronger solutions are used, such as those sold for commercial laundries, adjust the dosage accordingly.
1. Dosage a. Polystyrene resin: 1.2 fl uid ounces per cubic foot.
b. Non-resinous exchangers: 0.8 fl uid ounce per cubic foot.
2. Brine tank conditioners a. Backwash the conditioner and add the required amount of hypochlorite solution to the brine well of the brine tank. (The brine tank should have water in it to permit the solution to be carried into the conditioner.) b. Proceed with the normal regeneration. This will fl ush and condition the unit for use.
Calcium Hypochlorite
Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and granules. These solid materials may be used directly without dissolving before use.
1. Dosage a. Two grains (approximately 0.1 ounce) per cubic foot.
2. Brine tank conditioners a. Backwash the conditioner and add the required amount of hypochlorite to the brine well of the brine tank. (The brine tank should have water in it to permit the chlorine solution to be carried into the conditioner.) b. Proceed with the normal regeneration. This will fl ush and condition the unit for use.
*Clorox is a registered trademark of The Clorox Company.
Caution: Do NOT install on water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or a er the system.
| 22 | ProFlow Eliminator
Manufacturer’s Warranty
R&M Water Group
A Division of Water Technologies Inc.
To the original purchaser, the valve body, mineral container, cation resin, and salt tank carry an unconditional, non-prorated lifetime guarantee, which may be replaced F.O.B.
R&M Service Center.
This water conditioner, manufactured by R&M Water Group, is unconditionally guaranteed as to workmanship and materials at the original installation site for a period of five years from the date of original purchase.
Should any part or parts except those listed above prove defective after the initial five-year period, said part will be repaired, rebuilt, or replaced at manufacturer’s option for a maximum charge of $75. You carry all responsibility to pay expenses incurred in the delivery of the defective part to the manufacturer’s place of business.
R&M Manufacturing will not be responsible for labor charges, loss, or damages caused by a defective part.
This manufacturer’s warranty does not apply to units which have been installed on water pressure less than 20 psi, water pressure greater than 120 psi, or water temperature exceeding 120 o
(F). This warranty is void if the unit has been subjected to misuse, neglect, alterations, accident, damage caused by fire, flood, acts of God, or any other casualty.
This warranty gives you legal rights, and you may also have other and additional rights which may vary from state to state by statutory provisions.
If you desire information concerning this warranty, please contact the manufacturer directly.
R&M Water Group
28 South 1550 West
Lindon, Utah 84042
© 2004 R&M Water Group All rights reserved.
ProFlow Eliminator is a registered trademark of R&M Water Group pn: L-R-ProFlow-OM | rev: 02/04