Pro Flow 460i Series
Control Settings
ProFlow 460i Control
Water-Flow Indicator
Hour Time Display
PM Indicator
Access Door
Raised Tab
Jumper
Spare Jumper
Indicator Knob
Timer Locking Pin
Time-Set Button
Transformer Plug Receptable
Programming
Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control.
Open the access door by pushing the raised tab on the door toward the le while pulling the tab out (5).
Time-of-Day Setting
With the jumper on the set of pins next to the word TIME
(6), set the time of day to the closest hour by pressing the black TIME SET bu on. PM hours are indicated by a light next to the le ers PM on the display window.
Note
: The use of a small needle-nose pliers will aid in moving the jumper.
Note
: The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set the current time of day accordingly (e.g., to have the unit regenerate at
4:00 a.m.—two hours later—set the clock two hours earlier than the actual time of day).
Note
: The Timer Locking Pin should always be horizontal
(5) during operation.
ProFlow Eliminator | 7 |