Common Features. ProFlow S-100 SA-Eliminator 90, S-100 SA-Eliminator 70, S-100 SA-Eliminator 48, Water softener
Reklama
Reklama
Hardness Setting
Move the jumper to the set of pins next to the word
HARDNESS (8). Press the black TIME SET bu on until the hardness of the incoming water supply is displayed. The hardness range is from 1 to 99 grains per gallon.
To change water hardness stated in parts per million
(PPM) to grains per gallon (GPG) use this formula:
17.1
4. Depress the black TIME SET bu on. The numbers will roll from “0” to “15.” Release the switch at the desired number of days for the calendar override. For example, releasing the switch at “10” would program a 10-day calendar override.
6. Place jumper back on TIME and reconnect power.
7. The calendar override program is maintained during power outages by the NOVRAM circuitry.
8. To remove the calendar override, follow the same steps above and program back to “0.”
Figure 6 Figure 8 Figure 9
Capacity Setting
Move the jumper to the set of pins next to the word
CAPACITY (9). Press the black TIME SET bu on until the correct capacity value is displayed. The capacity range is 1 to 99 kilograins. Refer to the Suggested Salt Dial Se ings table (8).
Return the jumper to the top set of pins next to the word
TIME and replace the access door.
The jumper must
NOT be le on any pins other than the top pair next to the word TIME
. Otherwise, the unit may show a blank display.
Note: A spare jumper is located on the bo om set of pins.
In the event that the hardness or capacity se ing must be changed, simply follow the appropriate steps described above.
Common Features
Salt Dial Adjustment
These models may be adjusted to produce maximum to minimum conditioning capacities by se ing the salt dial, which controls the amount of salt used per regeneration.
When desired, the minimum se ing may be used on installations if the frequency of regeneration is increased to compensate for lower regenerated conditioning capacity. The installing dealer will set the unit for proper salt usage. Further adjustments are needed only if the hardness of the water supply changes or if water use changes dramatically. Capacity will need to be adjusted accordingly.
To adjust salt dosage, insert a small screwdriver into the white indicator knob and move pointer to proper salt se ing (Figure 10).
Note
: To convert the salt se ings from English to metric, divide by 2.2 (e.g., 12 pounds ³ 2.2 = 5.5 kg of salt).
Calendar Override Setting
2. Place jumper on Pin A and reconnect power.
3. Move jumper to Pin B. A zero will appear, indicating zero days of calendar override. All controllers are preprogrammed in this manner at the manufacturer.
Note
: System comes pre-programmed with default hardness, capacity and corresponding salt se ings. Refer to table 1 for default se ings.
Indicator Knob
Figure 9
: Indicator Knob
| 8 | ProFlow Eliminator
Model
Capacity
Se ing
Default
Salt Se ing
48 31,200 gr 7.5 lbs
70 48,000 gr 11.5 lbs
90 37,400 gr 8.8 lbs
Table 1
: Default salt se ing, by model
Model
48
70
90
Table 2
Max Flow
Rate
Pressure Drop @
Max Flow
12.1 gpm
15.5 gpm
18.0 gpm
13.0 psi
15.0 psi
15.0 psi
Exchange
Media
1.5
3
2.3
3
2.5
3
: Flow rates and pressure loss
Max Flow to Drain
(Regeneration)
2.5 gpm
3.5 gpm
4.0 gpm
Model
Tot. Gr.
Recovr’d
Gr.
Recov’rd p/ Salt lb
High-
Eff . Salt
Se ing
48 31,200 gr 4,160.0 gr 7.5 lbs
70 48,000 gr 4,170.0 gr 11.5 lbs
90 37,400 gr 4,200.0 gr 8.8 lbs
Tot. Gr.
Recovr’d
Gr.
Recovr’d p/ Salt lb
Mid-
Eff . Salt
Se ing
41,900 gr 2,756.6 gr 15.2 lbs
64,400 gr 2,763.9 gr 23.3 lbs
65,800 gr 2,600.8 gr 25.3 lbs
Tot. Gr.
Recovr’d
Gr.
Recovr’d p/ Salt lb
Low-
Eff . Salt
Se ing
47,600 gr 2,245.3 gr 21.2 lbs
73,100 gr 2,249.2 gr 32.5 lbs*
74,700 gr 2,116.1 gr 35.3 lbs*
Table 3
: Effi
* Extra salt cam: divide the suggested se ing by 2 to accomplish salt se ing.
Note: Use any good grade rock salt (NaCl) to obtain rated capacities.
The amount of salt placed in the brine tank has nothing to do with the amount of salt used during the regeneration cycle. Water will dissolve and absorb salt only until it becomes saturated. A given amount of brine (saltsaturated water) contains a specifi c amount of salt. The salt dial controls the amount of brine used during the regeneration cycle (e.g., when set at
15 pounds (6.8 kg) the amount of brine the conditioner will use for each regeneration will contain 15 pounds
(6.8 kg) of salt, etc.)
Never let the amount of salt in the brine tank be lower than the normal liquid level. Do not overload the brine tank with salt.
Manual Regeneration
Electricity is used only to run the control and to rotate the camsha . All other functions are operated by water pressure. Therefore, in the event of a power outage, all the regeneration positions may be dialed manually by depressing the indicator knob and turning
COUNTERCLOCKWISE
( and ). The following cycle times should be used for proper regeneration:
BACKWASH
—14 minutes
BRINE/SLOW RINSE
—52 minutes
FAST RINSE/REFILL
—10 minutes
PURGE
—6 minutes
Do not exceed 10 minutes for the
FAST RINSE/REFILL
cycle as this will cause excessive salt usage during the next regeneration and possibly a salt residue in the so ened water.
Guest Cycle
When abnormally high water usage exhausts your water conditioner’s capacity ahead of schedule, an extra regeneration can be achieved. Depress the indicator knob on the 440i (5) with a wide-blade screwdriver and turn
COUNTERCLOCKWISE
to
START
to initiate a regeneration. For the 460i, simply depress the indicator knob (5). It will take a few minutes for regeneration to start. A normal regeneration will take approximately two hours.
So ener conforms to WQA S-100 for the specifi c performance claims as verifi ed and substantiated by test data.
ProFlow Eliminator | 9 |