Preventive Maintenance
Injector Screen and Injector
Inspect and clean brine tank and screen fi lter on end of brine pickup tube once a year or when sediment appears in the bo om of the brine tank.
Clean injector screen and injector once a year:
1. Unplug the wall-mount transformer.
bypass position.
3. Relieve system pressure by opening valve No. 7
(at rear) with a screwdriver (Figure 11).
4. Using a screwdriver, remove injector screen and injector cap (Figure 14).
5. Clean screen using a fi ne brush. Flush until clean.
6. Using a needle-nose pliers, pull injector straight out.
7. Flush water into the injector screen recess of the valve body to fl ush debris out through the injector recess.
8. Clean and fl ush the injector.
9. Lubricate the O-rings on the injector, injector cap and injector screen with silicone lubricant
only
!
10. Reinstall the injector, injector cap and injector screen.
IMPORTANT
: Do not overtighten the plastic cap. Seat the cap lightly into position. Overtightening may cause breakage of the plastic cap that may not be immediately evident.
11. Plug the wall-mount transformer into outlet; reset clock if necessary.
12. Slowly open water supply valve or return bypass valve(s) to the “service” position.
Water Meter Maintenance
Note
: A water meter is used only with the 460i control.
If you are using the 440i control, this section does not pertain to your conditioner.
The metering device used with the 460i demand control may require simple maintenance. In rare instances, the turbine wheel of the water meter can collect small particles of oxidized iron, eventually preventing the wheel from turning.
into the bypass position.
2. Relieve pressure by opening the Backwash Drain
Valve (the seventh back from the control) with a screwdriver (Figure 11).
3. Loosen and remove the pipe/tube adapters or 1265 bypass from the inlet and outlet of the valve body.
4. Using a needle-nose pliers, remove the turbine from the outlet housing. Grasp one of the four vanes of the outer gland and pull straight out to remove turbine assembly from the outlet of the valve (Figure 14).
5. Carefully remove the turbine wheel from the housing.
Use a toothbrush to lightly scrub the iron off the magnet. Iron buildup on the surfaces can be removed by soaking the wheel in a mild sodium hydrosulfi te
(such as RoVer*) solution for a few minutes. Flush thoroughly with water.
6. Carefully reinstall the turbine wheel into the turbine cage housing. Make sure that the sha of the wheel seats into the bearing of the cage. Reassemble the turbine cage and check that the wheel rotates freely.
7. Reinstall the turbine cage into the outlet of the valve.
8. Reinstall the pipe/tube adapters or 1265 bypass to the inlet and outlet of the valve.
9. Turn on the water supply or put the bypass valve(s) into the service position and purge the air out of the system.
To check for proper meter operation, open a downstream faucet and observe the water fl ow indication on the control display.
*RoVer is a trademark of Hach Chemical Company.
Figure 14
: Removing injector screen and injector cap