Installation
All plumbing and electrical connections must conform to local codes.
Inspect unit carefully for carrier shortage or shipping damage.
This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or a er the system.
The most common bypass systems are the Autotrol Series 1265 bypass valve (1) and plumbed-in globe valves (2). Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation.
In
Not in Bypass
Out In
In Bypass
Out
Water Line Connection
The installation of a bypass valve system is recommended to provide for occasions when the water conditioner must be bypassed for hard water or for servicing.
S
S
B
S
S
B
SS PA
BY
SS PA
BY
Location Selection
1. The distance between the unit and a drain should be as short as possible.
2. If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available.
3. Since salt must be added periodically to the brine tank, the location should be easily accessible.
4. Do not install any unit closer to a water heater than a total run of 10 feet (3 m) of piping between the outlet of the conditioner and the inlet to the heater. Water heaters can sometimes overheat to the extent they will transmit heat back down the cold pipe into the unit control valve.
Hot water can severely damage the conditioner. A 10foot (3-m) total pipe run, including bends, elbows, etc., is a reasonable distance to help prevent this possibility.
A positive way to prevent hot water fl owing from heat source to the conditioner, in the event of a negative pressure situation, is to install a check valve in the so water piping from the conditioner.
If a check valve is installed, make certain the water heating unit is equipped with a properly rated temperature and pressure safety relief valve. Also, be certain that local codes are not violated.
5. Do not locate unit where it or its connections
(including the drain and overfl ow lines) will ever be subjected to room temperatures under 34 o F (1 o C) or over 120 o F (49 o C).
6. Do not install unit near acid or acid fumes.
7. The use of resin cleaners in an unvented enclosure is not recommended.
Water Conditioner Water Conditioner
Figure 1
: Autotrol Series 1265 bypass valve
Drain Line Connection
Note: Standard commercial practices are expressed here. Local codes may require changes to the following suggestions.
1. Ideally located, the unit will be above and not more than 20 feet (6.1 m) from the drain. For such installations, using an appropriate adapter fi ing, connect 1/2-inch (1.3-cm) plastic tubing to the drain line connection of the control valve.
2. If the backwash fl ow rate exceeds 5 gpm
(22.7 Lpm) or if the unit is located more than 20 feet
(6.1 m) from drain, use 3/4-inch (1.9-cm) tubing for runs up to 40 feet (12.2 m). Also, purchase appropriate fi ing to connect the 3/4-inch tubing to the 3/4-inch
NPT drain connection.
3. If the unit is located where the drain line must be elevated, you may elevate the line up to 6 feet
(1.8 m) providing the run does not exceed
15 feet (4.6 m) and water pressure at conditioner is not less than 40 psi (2.76 bar). You may elevate an additional 2 feet (61 cm) for each additional
10 psi (0.69 bar).
4. Where the drain line is elevated but empties into a drain below the level of the control valve, form a
7-inch (18-cm) loop at the far end of the line so that
| 4 | ProFlow Eliminator
the bo om of the loop is level with the drain line connection. This will provide an adequate siphon trap.
5. Where the drain empties into an overhead sewer line, a sink-type trap must be used.
IMPORTANT
: Never insert drain line into a drain, sewer line or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner.
Note
: Standard commercial practices have been expressed here. Local codes may require changes to these suggestions.
1” Air Gap
Right Way
Overflow Line Connection
In the absence of a safety overfl ow and in the event of a malfunction, the BRINE TANK OVERFLOW will direct
“overfl ow” to the drain instead of spilling on the fl oor where it could cause considerable damage. This fi ing should be on the side of the cabinet or brine tank.
To connect overfl ow, locate hole on side of brine tank.
Insert overfl ow fi ing (not supplied) into tank and tighten with plastic thumb nut and gasket as shown (4). A ach length of 1/2-inch (1.3-cm) I.D. tubing (not supplied) to fi ing and run to drain. Do not elevate overfl ow line higher than 3 inches (7.6 cm) below bo om of overfl ow fi ing. Do not tie into drain line of control unit. Overfl ow line must be a direct, separate line from overfl ow fi ing to drain, sewer or tub. Allow an air gap as per drain line instructions (2).
Overflow
Fitting Installed
Brine Tank
Figure 2
: Drain line with air gap
Brine Line Connection
It will be necessary to install the brine line to the brine fi ing on the valve (3/8-inch NPT).
Be sure all fi ings and connections are tight.
Connect 1/2-inch (1.3 cm)
Tubing or Hose and Run to Drain.
Figure 3
: Overfl ow fi ing
Drain Line
Incoming
To House
Overflow
Caution!
Do NOT connect coverfl ow and drainline. Brine tank overfl ow will occur.
1" Air Gap
Figure 4
: Eliminator drain and overfl ow layout
ProFlow Eliminator | 5 |