Removing the Valve
Assembly for Servicing
1. Unplug the power cord.
bypass position.
3. Remove cover and with screwdriver, relieve tank pressure by pushing open valve No. 7 (rear fl apper) on control as shown (Figure 11).
4. When used with a globe valve bypass, loosen and detach the inlet, outlet, brine and drain lines from the valve. If using the bypass, loosen and remove valve from bypass as well as loosening and removing the brine and drain lines.
5. Unscrew valve (counterclockwise) and remove valve from tank.
6. To replace the control valve, reverse the above procedure.
Controller for Servicing
1. Unplug the power cord.
3. Align the indicator arrow on the rear of the camsha with the top of the rear hoop of the top plate (Figure
12).
Indicator Arrow
Figure 12
: Top-down view of valve
4. Remove the camsha by carefully pushing the securing tab, located at the rear of the camsha , away from the camsha until the tab disengages from the camsha . Push the back of the camsha down and out to the inlet side of the valve (Figure 13).
Figure 11
: Valve assembly
Figure 13
: Removing the camsha
5. Disengage the front of the camsha from the output gear of the control.
6. Remove the timer locking pin and li the control straight up and off of the valve.
7. To reinstall the camsha and control, reverse the above procedures.