Troubleshooting. ProFlow S-100 SA-Eliminator 90, S-100 SA-Eliminator 70, S-100 SA-Eliminator 48, Water softener
विज्ञापन
विज्ञापन
Troubleshooting
The technology upon which the control valve is based is well established and proven in service over many years.
However, should a problem or question arise regarding the operation of the system, the control can very easily be serviced. For parts mentioned, refer to exploded views in the
Replacement Parts
section of this manual.
IMPORTANT
: Service procedures that require the water pressure to be removed from the system are marked with
Valve Troubleshooting
a “
§
” a er the possible cause. To remove water pressure from the system, put the bypass valve or three-valve bypass into the bypass position and open the backwash drain valve (the seventh valve back from the control) with a screwdriver. Restore system water pressure when the service work is completed.
The problems outlined below are the most common occurances of problems. If you are unable to solve your problem with this manual, contact the manufacturer.
Problem
Control will not draw brine.
Possible Cause
Low water pressure.
Solution
Set pump to maintain 30 psi at conditioner.
Brine tank overflow.
Restricted drain line.
Injector plugged§
Injector defective§
Valve (2 and/or 4) not closed.
Uncontrolled brine refill flow rate§
Valve (3 or 4) not closed during brine draw causing refill.
Air leak in brine line.
System using more or less salt than salt control is set for.
Inaccurate setting.
Foreign matter in controller causing incorrect flow rates§
Intermittent or irregular brine draw.
Brine valve (1) being held open.
Defective controller.
Low water pressure.
Remove restriction.
Lean injector and screen.
Replace injector.
Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace if needed.
Manually operate valve stem to flush away obstruction.
Remove variable salt controller to clean.
Flush out foreign matter by holding disc open and manually operating valve stem.
Check all connections in brine line for leaks.
Refer to instructions.
Correct setting.
Remove variable salt controller and flush out foreign matter. Manually position control to brine draw to clean controller (after so doing, position control to “purge” to remove brine from tank).
Replace controller.
Set pump to maintain 30 psi at conditioner.
No conditioned water after regeneration.
Control backwashes at excessively low or high rate.
Flowing or dripping water at drain or brine line after regeneration.
Hard water leakage during service.
Defective injector§
Unit did not regenerate.
Replace both injector and injector cap.
Check for power.
No salt in brine tank.
Plugged injector§
Valve stem return spring on top plate weak.
Improper regeneration.
Add salt.
Clean injector. Flush with water.
Incorrect backwash controller used.
Replace with correct size controller.
Foreign matter affecting controller operation§ Remove controller and ball. Flush with water.
Drain valve (5 or 6) or brine valve (1) held open by foreign matter or particle.
Manually operate valve stem to flush away obstruction.
Replace spring.
Leaking of bypass valve§
Repeat regeneration making certain that the correct salt dosage is set.
Replace O-ring.
O-ring around riser tube damaged§
Replace O-ring.
§ This procedure requires removal of water pressure from the system.
ProFlow Eliminator | 19 |
460i Control Troubleshooting
Problem
Clock does not display time of day.
Clock does not display correct time of day.
Possible Cause
Transformer cord unplugged.
No electric power at outlet.
Defective transformer.
Defective circuit board.
Outlet operated by switch.
Incorrect voltage or frequency (Hz).
Time display continues to advance.
Time display shows something other than time of day.
Power outages.
Defective time set switch.
Electrical interference.
No water flow display when water is flowing.
Defective circuit board.
Bypass valve in bypass.
Meter probe disconnected or not fully connected to meter housing.
Restricted meter turbine rotation due to foreign matter in meter.
Control regenerates at wrong time of day.
Timer stalled in regeneration cycle.
Defective meter probe.
Defective circuit board.
Power outages.
Clock set incorrectly.
Motor dead.
Motor runs backward.
No electric power at outlet.
Broken gear.
Defective switch.
Air leak in brine connections.
Binding of camshaft.
Water pressure greater than 125 psi during regeneration.
Defective circuit board.
Continuous regeneration. Camshaft does not stop at the end of regeneration.
Broken switch activator on gear.
Defective switch.
§ This procedure requires removal of water pressure from the system.
Solution
Connect power.
Repair outlet or use working outlet.
Replace transformer.
Replace timer.
Use outlet not controlled by switch.
Replace timer with one of correct voltage and frequency (Hz).
Reset clock.
Replace timer.
Disconnect power to unit. Restore power and reset time of day
Replace timer.
Shift bypass valve to not-in-bypass position.
Fully insert probe into meter housing.
Remove meter housing, free up turbine and flush with clean water. Do not disassemble turbine from meter housing. Turbine should spin freely. If not, replace meter§
Replace timer.
Replace timer.
Reset clock to correct time of day.
Reset clock to correct time of day.
Replace timer.
Replace timer.
Repair outlet or use working outlet.
Replace timer.
Replace timer.
Check all junction points and make appropriate corrections.
Remove foreign object obstruction from valve discs or camshaft.
Install pressure regulator§
Replace timer.
Replace timer.
Replace timer.
| 20 | ProFlow Eliminator
460i Control Troubleshooting (con't)
Problem
Control will not regenerate automatically or when button is pressed.
Control will not regenerate automatically but will regenerate when button is pressed.
Possible Cause
Electric cord unplugged.
No electric power at outlet.
Defective motor.
Broken gear.
Binding in gear train.
Defective switch.
If water flow display is not operative, refer to
Item 5
Defective circuit board.
Incorrect hardness and capacity settings.
Solution
Connect power.
Repair outlet or use working outlet.
Replace timer.
Replace timer.
Replace timer.
Replace timer.
Same as Item 5.
Run out of soft water between regenerations.
Improper regeneration.
Fouled softener resin.
Incorrect salt setting.
Incorrect harness or capacity settings.
Water hardness has increased.
Restricted meter turbine rotation due to foreign material in meter housing.
Replace timer.
Set to correct values. See Programming section.
Repeat regeneration, making certain that correct salt dosage is used.
Use resin cleaner. See Note 1.
Set salt control to proper level. See Salt Setting chart.
Set to correct values. See Programming section.
Set hardness to new value. See Programming section.
Remove meter housing, free us turbine and flush with clean water. DO NOT DISASSEMBLE
TURBINE FROM METER HOUSING. Turbine should spin freely, if not, replace meter§
Repair leaky plumbing and/or fixtures§ Excessive water usage below 1/5 gallon per minute.
§ This procedure requires removal of water pressure from the system.
Note: 1: Use of resin cleaners in an unvented enclosure is not recommended.
ProFlow Eliminator | 21 |