advertisement
![Advantech EKI-9628G User manual | Manualzz Advantech EKI-9628G User manual | Manualzz](http://s3.manualzz.com/store/data/032054956_1-a944fa5539beb7972e47d8ed2103009b-360x466.png)
User Manual
EKI-9628G
24G+4G Combo port L3
Managed Switch
Copyright
The documentation and the software included with this product are copyrighted 2006 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co.,
Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use.
Acknowledgements
Intel and Pentium are trademarks of Intel Corporation.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.
Product Warranty (5 years)
Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for five years from the date of purchase.
This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty as a consequence of such events.
Because of Advantech’s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For out ofwarranty repairs, you will be billed according to the cost of replacement materials, service time and freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:
1.
Collect all the information about the problem encountered. (For example, CPU speed, Advantech products used, other hardware and software used, etc.) Note anything abnormal and list any on screen messages you get when the problem occurs.
2.
Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available.
3.
If your product is diagnosed as defective, obtain an RMA (return merchandize authorization) number from your dealer. This allows us to process your return more quickly.
4.
Carefully pack the defective product, a fully-completed Repair and Replacement
Order Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service.
5.
Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer.
EKI-9628G User Manual
Part No. XXXXXXXXXX
Printed in Taiwan ii
Edition 1
July 2017
Declaration of Conformity
CE
This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products.
FCC Class A
Note: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Technical Support and Assistance
1.
Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product.
2.
Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call:
– Product name and serial number
– Description of your peripheral attachments
– Description of your software (operating system, version, application software, etc.)
– A complete description of the problem
– The exact wording of any error messages iii EKI-9628G User Manual
Warnings, Cautions and Notes
Warning! Warnings indicate conditions, which if not observed, can cause personal injury!
Caution! Cautions are included to help you avoid damaging hardware or losing data. e.g.
There is a danger of a new battery exploding if it is incorrectly installed.
Do not attempt to recharge, force open, or heat the battery. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions.
Note!
Notes provide optional additional information.
Document Feedback
To assist us in making improvements to this manual, we would welcome comments and constructive criticism. Please send all such - in writing to: [email protected]
Packing List
Before setting up the system, check that the items listed below are included and in good condition. If any item does not accord with the table, please contact your dealer immediately.
1 x Industrial Ethernet Switch
2 x Wall-mounting Bracket
1 x Startup Manual
EKI-9628G User Manual iv
Safety Instructions
1.
Read these safety instructions carefully.
2.
Keep this User Manual for later reference.
3.
Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning.
4.
For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible.
5.
Keep this equipment away from humidity.
6.
Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.
7.
The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS.
8.
Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.
9.
Position the power cord so that people cannot step on it. Do not place anything over the power cord.
10.
All cautions and warnings on the equipment should be noted.
11.
If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage.
12.
Never pour any liquid into an opening. This may cause fire or electrical shock.
13.
Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.
14.
If one of the following situations arises, get the equipment checked by service personnel:
15.
The power cord or plug is damaged.
16.
Liquid has penetrated into the equipment.
17.
The equipment has been exposed to moisture.
18.
The equipment does not work well, or you cannot get it to work according to the user's manual.
19.
The equipment has been dropped and damaged.
20.
The equipment has obvious signs of breakage.
21.
DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE
STORAGE TEMPERATURE MAY GO BELOW -20° C (-4° F) OR ABOVE 60° C
(140° F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT
SHOULD BE IN A CONTROLLED ENVIRONMENT.
22.
CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY
REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES
ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.
23.
The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than 70 dB (A).
DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein.
v EKI-9628G User Manual
Wichtige Sicherheishinweise
1.
Bitte lesen sie Sich diese Hinweise sorgfältig durch.
2.
Heben Sie diese Anleitung für den späteren Gebrauch auf.
3.
Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie
Keine Flüssig-oder Aerosolreiniger. Am besten dient ein angefeuchtetes Tuch zur Reinigung.
4.
Die NetzanschluBsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein.
5.
Das Gerät ist vor Feuchtigkeit zu schützen.
6.
Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein Kippen oder Fallen könnte Verletzungen hervorrufen.
7.
Die Belüftungsöffnungen dienen zur Luftzirkulation die das Gerät vor überhitzung schützt. Sorgen Sie dafür, daB diese Öffnungen nicht abgedeckt werden.
8.
Beachten Sie beim. AnschluB an das Stromnetz die AnschluBwerte.
9.
Verlegen Sie die NetzanschluBleitung so, daB niemand darüber fallen kann. Es sollte auch nichts auf der Leitung abgestellt werden.
10.
Alle Hinweise und Warnungen die sich am Geräten befinden sind zu beachten.
11.
Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom
Stromnetz trennen. Somit wird im Falle einer Überspannung eine Beschädigung vermieden.
12.
Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw. elektrischen Schlag auslösen.
13.
Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen
Sicherheit nur von authorisiertem Servicepersonal geöffnet werden.
14.
Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen:
15.
Netzkabel oder Netzstecker sind beschädigt.
16.
Flüssigkeit ist in das Gerät eingedrungen.
17.
Das Gerät war Feuchtigkeit ausgesetzt.
18.
Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder
Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen.
19.
Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt.
20.
Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.
21.
VOSICHT: Explisionsgefahr bei unsachgemaben Austausch der Batterie.Ersatz nur durch densellben order einem vom Hersteller empfohlene-mahnlichen Typ.
Entsorgung gebrauchter Batterien navh Angaben des Herstellers.
22.
ACHTUNG: Es besteht die Explosionsgefahr, falls die Batterie auf nicht fachmännische Weise gewechselt wird. Verfangen Sie die Batterie nur gleicher oder entsprechender Type, wie vom Hersteller empfohlen. Entsorgen Sie Batterien nach Anweisung des Herstellers.
23.
Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt
70dB(A) oder weiger.
Haftungsausschluss: Die Bedienungsanleitungen wurden entsprechend der IEC-
704-1 erstellt. Advantech lehnt jegliche Verantwortung für die Richtigkeit der in diesem Zusammenhang getätigten Aussagen ab.
EKI-9628G User Manual vi
Safety Precaution - Static Electricity
Follow these simple precautions to protect yourself from harm and the products from damage.
To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on.
Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components.
vii EKI-9628G User Manual
Contents
Chapter 1 Product Overview
............................... 1
Front View..................................................................................... 3
Rear View ..................................................................................... 4
Chapter 2 Switch Installation
.............................. 6
Environment and Enclosure Guidelines.................................................... 9
Connecting Hardware ................................................................... 9
Verifying Switch Operation........................................................................ 9
Rack-Mounting............................................................................ 10
Installing and Removing SFP Modules ................................................... 10
Installing SFP Modules ............................................................... 11
Removing SFP Modules ............................................................. 12
Connecting the Switch to Ethernet Ports ................................................ 13
RJ45 Ethernet Cable Wiring ....................................................... 13
Connecting the Switch to Console Port .................................................. 14
Power Supply Installation........................................................................ 15
Overview..................................................................................... 15
Considerations............................................................................ 16
Grounding the Device ................................................................. 16
Wiring a Relay Contact ............................................................... 17
Wiring the Power Inputs.............................................................. 18
Chapter 3 Configuration Utility
......................... 20
Overview..................................................................................... 21
Introduction ................................................................................. 21
Administrative Interface Access.................................................. 21
Using the Graphical (Web) Interface .......................................... 22
Configuring the Switch for Network Access................................ 22
Configuring the Ethernet Ports ................................................... 23
Command Line Interface Configuration .................................................. 24
Introduction to Command-Line Interface (CLI) ........................... 24
Accessing the CLI....................................................................... 24
Web Browser Configuration .................................................................... 25
Preparing for Web Configuration ................................................ 25
System Login .............................................................................. 25
Chapter 4 Managing Switch
............................... 26
Recommended Practices........................................................................ 27
Changing Default Password ....................................................... 27
EKI-9628G User Manual viii
Device Information ...................................................................... 28
Logging Message........................................................................ 29
Port Monitoring............................................................................ 30
Link Aggregation ......................................................................... 31
LLDP Statistics............................................................................ 32
IGMP Statistics ........................................................................... 33
IGMP Statistics ........................................................................... 34
IP Settings................................................................................... 35
IPv6 Settings............................................................................... 35
System Time ............................................................................... 36
Network Port ............................................................................... 37
Port Configuration ....................................................................... 38
Port Mirror ................................................................................... 39
Link Aggregation ......................................................................... 40
802.1Q VLAN.............................................................................. 43
Q-in-Q ......................................................................................... 46
GARP.......................................................................................... 48
802.3az EEE ............................................................................... 49
Multicast...................................................................................... 50
Jumbo Frame.............................................................................. 54
4.5.10 Spanning Tree ............................................................................ 55
4.5.13 Loopback Detection .................................................................... 62
SNAT (Source NAT) ................................................................... 64
DNAT (Destination NAT)............................................................. 65
Routing........................................................................................ 66
Static MAC .................................................................................. 66
MAC Aging Time......................................................................... 67
Dynamic Forwarding Table ......................................................... 67
Storm Control.............................................................................. 68
Port Security ............................................................................... 70
Protected Ports ........................................................................... 70
DoS Prevention........................................................................... 71
Applications................................................................................. 73
802.1x ......................................................................................... 75
IP Security................................................................................... 76
General ....................................................................................... 77
QoS Basic Mode ......................................................................... 83
Rate Limit.................................................................................... 84
4.10.3 TCP Modbus Settings ................................................................. 91
4.10.4 DHCP Server .............................................................................. 92
4.11.1 Cable Diagnostics ..................................................................... 103
4.11.3 IPv6 Ping Test........................................................................... 105
ix EKI-9628G User Manual
4.11.6 LED Indication .......................................................................... 109
4.12.1 Backup Manager....................................................................... 110
4.12.2 Upgrade Manager..................................................................... 111
4.12.4 Save Configuration ................................................................... 112
4.12.5 User Account ............................................................................ 112
4.12.6 Reset System ........................................................................... 113
4.12.7 Reboot Device .......................................................................... 113
Modbus/TCP Mapping .......................................................................... 113
4.13.1 Modbus/TCP Mapping Table .................................................... 113
Chapter 5 Troubleshooting
.............................. 133
EKI-9628G User Manual x
List of Figures
Figure 4.13
Figure 4.14
Figure 4.15
Figure 4.16
Figure 4.17
Figure 4.18
Figure 4.19
Figure 4.20
Figure 4.21
Figure 4.22
Figure 4.23
Figure 4.24
Figure 4.25
Figure 4.26
Figure 4.27
Figure 4.28
Figure 4.29
Figure 4.30
Figure 4.31
Figure 4.32
Figure 4.33
Figure 4.34
Figure 4.35
Figure 4.36
Figure 2.13
Figure 2.14
Figure 2.15
Figure 2.16
Figure 4.1
Figure 4.2
Figure 4.3
Figure 4.4
Figure 4.5
Figure 4.6
Figure 4.7
Figure 4.8
Figure 4.9
Figure 4.10
Figure 4.11
Figure 4.12
Figure 1.1
Figure 1.2
Figure 1.3
Figure 1.4
Figure 2.1
Figure 2.2
Figure 2.3
Figure 2.4
Figure 2.5
Figure 2.6
Figure 2.7
Figure 2.8
Figure 2.9
Figure 2.10
Figure 2.11
Figure 2.12
Front View ..................................................................................................................... 3
System LED Panel ........................................................................................................ 3
Rear View ...................................................................................................................... 4
Dimensions.................................................................................................................... 5
Installing the Rack Mount Brackets ............................................................................. 10
Installing the Switch..................................................................................................... 10
Removing the Dust Plug from an SFP Slot ................................................................. 11
Installing an SFP Transceiver...................................................................................... 11
Attaching a Fiber Optic Cable to a Transceiver........................................................... 12
Removing a Fiber Optic Cable to a Transceiver.......................................................... 12
Removing an SFP Transceiver.................................................................................... 12
Ethernet Plug & Connector Pin Position...................................................................... 13
Serial Console Cable................................................................................................... 14
DB 9 Pin Position......................................................................................................... 14
Pin Assignment............................................................................................................ 14
Power Wiring for EKI-9628G ....................................................................................... 15
Grounding Connection................................................................................................. 17
Terminal Receptor: Relay Contact .............................................................................. 17
Terminal Receptor: Power Input Contacts................................................................... 18
Installing DC Wires in a Terminal Block ...................................................................... 18
Login Screen ............................................................................................................... 27
Changing a Default Password ..................................................................................... 28
Monitoring > Device Information.................................................................................. 28
Monitoring > Logging Message ................................................................................... 29
Monitoring > Port Monitoring > Port Statistics ............................................................. 30
Monitoring > Port Monitoring > Port Utilization ............................................................ 31
Monitoring > Link Aggregation..................................................................................... 31
Monitoring > LLDP Statistics ....................................................................................... 32
Monitoring > IGMP Statistics ....................................................................................... 33
Monitoring > MLD Statistics......................................................................................... 34
System > IP Settings ................................................................................................... 35
System > IPv6 Settings ............................................................................................... 35
System > System Time................................................................................................ 36
System > Network Port................................................................................................ 37
L2 Switching > Port Configuration ............................................................................... 38
L2 Switching > Port Mirror ........................................................................................... 39
L2 Switching > Link Aggregation > Load Balance ....................................................... 40
L2 Switching > Link Aggregation > LAG Management................................................ 40
L2 Switching > Link Aggregation > LAG Port Settings ................................................ 41
L2 Switching > Link Aggregation > LACP Priority Settings ......................................... 41
L2 Switching > Link Aggregation > LACP Port Settings .............................................. 42
L2 Switching > 802.1Q VLAN > VLAN Management .................................................. 43
L2 Switching > 802.1Q VLAN > PVID Settings ........................................................... 43
L2 Switching > 802.1Q VLAN > Port to VLAN............................................................. 45
L2 Switching > 802.1Q VLAN > VLAN Interface Management ................................... 46
L2 Switching > Q-in-Q > Global Settings..................................................................... 46
L2 Switching > Q-in-Q > Port Settings......................................................................... 47
L2 Switching > GARP > GARP Settings...................................................................... 48
L2 Switching > GARP > GVRP Settings...................................................................... 49
L2 Switching > 802.3az EEE ....................................................................................... 49
L2 Switching > Multicast > Multicast Filtering .............................................................. 50
L2 Switching > Multicast > IGMP Snooping > IGMP Settings ..................................... 50
L2 Switching > Multicast > IGMP Snooping > IGMP Querier ...................................... 51
L2 Switching > Multicast > IGMP Snooping > IGMP Static Groups ............................ 51
L2 Switching > Multicast > MLD Snooping > MLD Settings ........................................ 52
L2 Switching > Multicast > MLD Snooping > MLD Querier ......................................... 53 xi EKI-9628G User Manual
Figure 4.69
Figure 4.70
Figure 4.71
Figure 4.72
Figure 4.73
Figure 4.74
Figure 4.75
Figure 4.76
Figure 4.77
Figure 4.78
Figure 4.79
Figure 4.80
Figure 4.81
Figure 4.82
Figure 4.83
Figure 4.84
Figure 4.85
Figure 4.86
Figure 4.87
Figure 4.88
Figure 4.89
Figure 4.90
Figure 4.91
Figure 4.92
Figure 4.93
Figure 4.94
Figure 4.95
Figure 4.96
Figure 4.53
Figure 4.54
Figure 4.55
Figure 4.56
Figure 4.57
Figure 4.58
Figure 4.59
Figure 4.60
Figure 4.61
Figure 4.62
Figure 4.63
Figure 4.64
Figure 4.65
Figure 4.66
Figure 4.67
Figure 4.68
Figure 4.37
Figure 4.38
Figure 4.39
Figure 4.40
Figure 4.41
Figure 4.42
Figure 4.43
Figure 4.44
Figure 4.45
Figure 4.46
Figure 4.47
Figure 4.48
Figure 4.49
Figure 4.50
Figure 4.51
Figure 4.52
L2 Switching > Multicast > MLD Snooping > MLD Static Group ................................. 53
L2 Switching > Jumbo Frame...................................................................................... 54
L2 Switching > Spanning Tree > STP Global Settings................................................ 55
L2 Switching > Spanning Tree > STP Port Settings.................................................... 56
L2 Switching > Spanning Tree > STP Bridge Settings................................................ 57
L2 Switching > Spanning Tree > STP Port Advanced Settings................................... 57
L2 Switching > Spanning Tree > MST Config Identification ........................................ 58
L2 Switching > Spanning Tree > MST Instance ID Settings ....................................... 58
L2 Switching > Spanning Tree > MST Instance Priority Settings................................ 59
L2 Switching > X-Ring Elite > X-Ring Elite Settings.................................................... 60
L2 Switching > X-Ring Elite > X-Ring Elite Groups ..................................................... 60
L2 Switching > X-Ring Pro > X-Ring Pro Settings....................................................... 61
L2 Switching > X-Ring Pro > X-Ring Pro Groups > X-Ring Pro Groups Settings ....... 61
L2 Switching > X-Ring Pro > X-Ring Pro Groups > Couple Setting ............................ 62
L2 Switching > Loopback Detection > Global Settings................................................ 62
L2 Switching > Loopback Detection > Port Settings ................................................... 63
L3 Switching > SNAT > Global Settings...................................................................... 64
L3 Switching > SNAT > Entry Settings........................................................................ 64
L3 Switching > DNAT .................................................................................................. 65
L3 Switching > Routing ............................................................................................... 66
MAC Address Table > Static MAC .............................................................................. 66
MAC Address Table > MAC Aging Time ..................................................................... 67
MAC Address Table > Dynamic Forwarding Table ..................................................... 67
Security > Storm Control > Global Settings................................................................. 68
Security > Storm Control > Port Settings .................................................................... 69
Security > Port Security............................................................................................... 70
Security > Protected Ports........................................................................................... 70
Security > DoS Prevention > DoS Global Settings...................................................... 71
Security > DoS Prevention > DoS Port Settings ......................................................... 72
Security > Applications > TELNET .............................................................................. 73
Security > Applications > SSH .................................................................................... 73
Security > Applications > HTTP .................................................................................. 74
Security > Applications > HTTPS ................................................................................ 74
Security > 802.1x > 802.1x Settings............................................................................ 75
Security > 802.1x > 802.1x Port Configuration............................................................ 76
Security > IP Security > Global Settings ..................................................................... 76
Security > IP Security > Entry Settings ....................................................................... 77
QoS > General > QoS Properties................................................................................ 78
QoS > General > QoS Settings ................................................................................... 78
QoS > General > QoS Scheduling .............................................................................. 79
QoS > General > CoS Mapping .................................................................................. 80
QoS > General > DSCP Mapping ............................................................................... 81
QoS > General > IP Precedence Mapping.................................................................. 82
QoS > QoS Basic Mode > Global Settings.................................................................. 83
QoS > QoS Basic Mode > Port Settings ..................................................................... 83
QoS > Rate Limit > Ingress Bandwidth Control........................................................... 84
QoS > Rate Limit > Egress Bandwidth Control ........................................................... 84
QoS > Rate Limit > Egress Queue.............................................................................. 85
Management > LLDP > LLDP System Settings .......................................................... 86
Management > LLDP > LLDP Port Settings > LLDP Port Configuration..................... 87
Management > LLDP > LLDP Port Settings > Optional TLVs Selection ..................... 87
Management > LLDP > LLDP Port Settings > VLAN Name TLV VLAN Selection...... 88
Management > LLDP > LLDP Remote Device Info..................................................... 88
Management > SNMP > SNMP Settings .................................................................... 89
Management > SNMP > SNMP Community ............................................................... 89
Management > SNMP > SNMP User Settings............................................................ 90
Management > SNMP > SNMP Trap .......................................................................... 91
Management > TCP Modbus Settings > TCP Modbus Settings ................................. 91
Management > DHCP Server > Status Settings ......................................................... 92
Management > DHCP Server > Global Settings ......................................................... 93
EKI-9628G User Manual xii
Figure 4.97
Figure 4.98
Management > DHCP Server > Port Settings ............................................................. 94
Management > DHCP Server > VLAN Settings .......................................................... 95
Figure 4.99
Management > DHCP Server > Option 82 Settings .................................................... 96
Figure 4.100
Management > SMTP Client > Global Settings........................................................... 97
Figure 4.101
Management > SMTP Client > Profile Settings > Profile Settings............................... 97
Figure 4.102
Management > SMTP Client > Profile Settings > Profile Target Mail Settings............ 98
Figure 4.103
Management > SMTP Client > Sending Message ...................................................... 99
Figure 4.104
Management > RMON > Rmon Statistics ................................................................. 100
Figure 4.105
Management > RMON > RMON History ................................................................... 100
Figure 4.106
Management > RMON > Rmon Alarm ...................................................................... 101
Figure 4.107
Management > RMON > RMON Event ..................................................................... 102
Figure 4.108
Diagnostics > Cable Diagnostics ............................................................................... 103
Figure 4.109
Diagnostics > Ping Test............................................................................................. 104
Figure 4.110
Diagnostics > IPv6 Ping Test..................................................................................... 105
Figure 4.111
Diagnostics > System Log > Logging Service ........................................................... 106
Figure 4.112
Diagnostics > System Log > Local Logging .............................................................. 107
Figure 4.113
Diagnostics > System Log > System Log Server ...................................................... 108
Figure 4.114
Diagnostics > DDM.................................................................................................... 108
Figure 4.115
Diagnostics > DDM.................................................................................................... 109
Figure 4.116
Diagnostics > LED Indication..................................................................................... 109
Figure 4.117
Tools > Backup Manager........................................................................................... 110
Figure 4.118
Tools > Upgrade Manager......................................................................................... 111
Figure 4.119
Tools > Dual Image ................................................................................................... 111
Figure 4.120
Tools > User Account ................................................................................................ 112 xiii EKI-9628G User Manual
Chapter
1
Product Overview
1
1.1
Specifications
Specifications Description
Interface
Physical
LED Display
Environment
I/O Port 24 x 10/100/1000BaseT(X) + 4 x 10/100/1000Base-
T(X) or 4 x 100/1000Base-X SFP Port
Power Connector 4-pin removable screw terminal (power)
3-pin removable screw terminal (relay)
Enclosure Metal Shell
Protection Class IP30
Installation Rack mounting
438.0 x 43.6 x 259.2mm
Dimensions
(W x H x D)
System LED SYS, PWR1, PWR2, P-Fail, Loop detection, R.M.,
Ring Fail, Temp
Speed, Link, Activity
-40°C ~ 70°C (-40°F ~ 158°F)
Port LED
Operating
Temperature
Storage
Temperature
Ambient Relative
Humidity
-40°C ~ 85°C (-40°F ~ 185°F)
10 ~ 95% (non-condensing)
8K-entry
56 Gbps
Switch Properties MAC Address
Switching Bandwidth
Power Power
Consumption
Power Input
Certifications Safety
EMC
EMI
EMS
20W @ 24V
12V~48VDC
UL 61010-2-201
CE, FCC
EN55022 Class A
EN 61000-4-2 (ESD) Level 3
EN 61000-4-3 (RS) Level 3;
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge) Level 3;
EN 61000-4-6 (CS) Level 3
EN 61000-4-8 (Magnetic Field) Level 3
Shock
Freefall
Vibration
Railway Track
Side
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
EN 50121-4
2 EKI-9628G User Manual
1.2
Hardware Views
1.2.1
Front View
24 22 20 18 16 14 12 10 LINK/ACT 28 Speed
EKI-9628G
Reset
SYS
PW1
PW2
P-FAIL
LOOP
R.M.
R-Fail
Temp
LINK/ACT
27
Speed
26
25
LINK / ACT
28
26
27 25
28
27
26
25
1 2 3 4
23 21 19 17
5 6 7
Figure 1.1 Front View
15 13 11 9
8
8 6 4 LINK/ACT 2 Speed
7 5 3
LINK/ACT
1
Speed
2
3
4
5
6
7
No.
Item
1 Reset button
System LED panel
ETH port
SFP LEDs
ETH port
LNK/ACT LED
Speed LED
8 ETH port
1.2.1.1
System LED Panel
Description
Button allows for system soft reset (3 sec.) or factory default reset
(5 sec.).
See “System LED Panel” on page 3 for further details.
RJ45 ports x 4.
SFP link activity LEDs.
Fiber ports x 4.
Link activity LED.
Orange: 100M
Green: 1G
RJ45 ports x 24.
1
4
5
2
3
SYS
PW1
PW2
P-FAIL
LOOP
R.M.
R-Fail
Temp
6
7
8
9
LINK / ACT
28
26
27 25
10 11
No.
1
2
3
4
5
LED Name
SYS
PWR1
PWR2
P-FAIL
LED Color
Solid green
Off
Solid green
Off
Solid green
Off
Solid red
Off
LOOP Detection Solid red
Off
Figure 1.2 System LED Panel
Description
System is operating normally.
System is powered down / system crash / operation initiating.
Powered up.
Powered down or not installed.
Powered up.
Power down or not installed.
When PW1 or PW2 is disconnected, the LED lights.
When PW1 and PW2 is connected, the LED is off.
When loop detected, the LED lights.
No loop detected.
EKI-9628G User Manual 3
No.
LED Name
6 R. M.
(Ring Master)
7 Ring Fail
8 Temp
LED Color
Solid green
Off
Solid red
Off
Solid red
Off
SFP
9 SFP LED
RJ45
10
11
PoE
LNK/ACT
Solid green
Blink green
Off
Solid green
Blink green
Off
Solid green
Blink green
Off
Solid amber
Blink amber
Off
Solid green
1.2.2
Rear View
Description
An active switch within the ring is a designated ring master.
No ring master determined in current ring.
A ring port within the ring loop is identified has having a ring ID within a second ring loop.
No ring ports having a ring ID within a secondary ring loop are detected.
IC sensor detects a temperature range exceeding set temperature range.
IC sensor detects normal operating temperature.
SFP or GBIC plug-in and link up.
Packet transmit and receive.
SFP or GBIC plug-out or link down.
Connect to PD and supply power.
Not applicable.
Disconnect from PD and No supply Power.
Current link speed is 1000M.
Packet transmit and receive.
No link.
Current link speed is 100/10M.
Packet transmit and receive.
No link.
Connect to PD and supply power.
P-Fail
12~48VDC
PWR1 PWR2
Console
1 2 3
V1V1+ V2V2+
4
Figure 1.3 Rear View
No.
Item
1
2
3
4
Ground terminal
Console serial port
P-Fail block
Power block
Description
Screw terminal used to ground chassis.
Console cable port to COM port (DB9 male) on computer to RS232 managed switch (RJ45 female).
An open circuit occurs upon detecting a power failure.
A close circuit denotes normal power activity.
Connect cabling for power wiring.
4 EKI-9628G User Manual
1.3
Dimensions
DC 8V ~4 12 12~48VDC
22 41
426
438
Figure 1.4 Dimensions
1.4
Packing List
The product package you have received should contain the following items. If any of them are not included or damaged, please contact your local vendor for support.
1 x Industrial Ethernet Switch
1 x Rack Mount Kit
1 x Startup Manual
1 x EKI Device Configuration Utility CD ROM
EKI-9628G User Manual 5
Chapter
2
Switch Installation
2
2.1
Warnings
Warning: Before working on equipment that is connected to power lines, remove any jewelry (including rings, necklaces, and watches). Metal objects can heat up when connected to power and ground, which can cause serious burns or weld the metal object to the terminals.
Caution! Exposure to chemicals can degrade the sealing properties of materials used in the sealed relay device.
Caution! It is not recommended to work on the system or connect or disconnect cables during periods of lightning activity.
Caution! Before performing any of the following procedures, disconnect the power source from the DC circuit.
Caution! Read the installation instructions before connecting the system to its power source.
Caution! The device must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor.
Caution! This unit may have more than one power supply connection. All connections must be removed to de-energize the unit.
Caution! The installation, replacement, or service of the device must be Only be performed by trained and qualified personnel.
EKI-9628G User Manual 7
Caution! Ultimate disposal of this product should be handled according to local and national regulations
Caution! To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of: 70°C
(158°F).
Caution! If the switch is to be installed in a hazardous location, ensure that the
DC power source is located away from the vicinity of the switch.
Caution! The installation of the equipment must comply with all national and local electrical codes.
Caution! Explosion Hazard-The area must be known to be nonhazardous before servicing or replacing any components.
Warning! Airflow around the switch must be unrestricted. To prevent the switch from overheating, there must be the following minimum clearances:
Top and bottom: 2.0 in. (50.8 mm)
Sides: 2.0 in. (50.8 mm)
Front: 2.0 in. (50.8 mm)
2.2
Installation Guidelines
The following guidelines are provided to optimize the device performance. Review the guidelines before installing the device.
Make sure cabling is away from sources of electrical noise. Radios, power lines, and fluorescent lighting fixtures can interference with the device performance.
Make sure the cabling is positioned away from equipment that can damage the cables.
Operating environment is within the ranges listed range, see “Specifications” on page 2.
Relative humidity around the switch does not exceed 95 percent (noncondensing).
8 EKI-9628G User Manual
Altitude at the installation site is not higher than 10,000 feet.
In 10/100 and 10/100/1000 fixed port devices, the cable length from the switch to connected devices can not exceed 100 meters (328 feet).
Make sure airflow around the switch and respective vents is unrestricted. Without proper airflow the switch can overheat. To prevent performance degredation and damage to the switch, make sure there is clerance at the top and bottom and around the exhaust vents.
2.3
Environment and Enclosure Guidelines
Review these environmental and enclosure guidelines before installation:
This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 9842 ft (3 km) without derating.
This equipment is considered Group 1, Class A industrial equipment, according to
IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance.
This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame-spread rating of 5VA, V2, V1, V0 (or equivalent) if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication might contain additional information regarding specific enclosure-type ratings that are required to comply with certain product safety certifications.
2.3.1
Connecting Hardware
In this instruction, it will explain how to find a proper location for your Modbus Gateways, and how to connect to the network, hock up the power cable, and connect to the EKI-9628G.
2.4
Verifying Switch Operation
Before installing the device in a rack or on a wall, power on the switch to verify that the switch passes the power-on self-test (POST). To connect the cabling to the power
source see “Power Supply Installation” on page 15.
At startup (POST), the System LED blinks green, while the remaining LEDs are a solidy green. Once the switch passes POST self-test, the System LED turns green.
The other LEDs turn off and return to their operating status. If the switch fails POST, the System LED switches to an amber state.
After a successful self-test, power down the switch and disconnect the power cabling.
The switch is now ready for installation on its final location.
EKI-9628G User Manual 9
2.5
Installing the Switch
2.5.1
Rack-Mounting
1.
Align the rack mount brackets with the holes on the switch.
2.
Secure the rack mount brackets with the provided screws.
EKI-9628G
Reset
SYS
PW1
PW2
P-FAIL
LOOP
R.M.
R-Fail
Temp
LINK/ACT
28
Speed
LINK/ACT
27
Speed
26
25
LINK / ACT
28
27
26
25
24
22
20
18
23
21
19
17
16
14
12
10
15
13
11
9
8
6
4
LINK/ACT
2
Speed
7
5
3
LINK/ACT
1 Speed
Figure 2.1 Installing the Rack Mount Brackets
3.
Align the switch with the posts on the rack cabinet.
4.
Secure the switch with the provided screws.
EKI-9628G
Reset
SYS
PW1
PW2
P-FAIL
LOOP
R.M.
R-Fail
Temp
LINK/ACT 28
Speed
LINK/ACT
27 Speed
26
25
LINK / ACT
28
27
26
25
24
22
20
18
23
21
19
17
16
14
12
10
15
13
11
9
8
6
4
LINK/ACT
2 Speed
7
5
3
LINK/ACT
1
Speed
Figure 2.2 Installing the Switch
2.6
Installing and Removing SFP Modules
Up to two fiber optic ports are available (depends on model) for use in the switch.
Refer to the technical specifications for details.
The Gigabit Ethernet ports on the switch are 100/1000Base SFP Fiber ports, which require using the 100M or 1G mini-GBIC fiber transceivers to work properly. Advantech provides completed transceiver models for different distance requirement.
The concept behind the LC port and cable is quite straight forward. Suppose that you are connecting devices I and II; contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission.
Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you make your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, or A1-to-A2 and B1-to-B2).
10 EKI-9628G User Manual
2.6.1
Installing SFP Modules
To connect the fiber transceiver and LC cable, use the following guidelines:
1.
Remove the dust plug from the fiber optic slot chosen for the SFP transceiver.
Figure 2.3 Removing the Dust Plug from an SFP Slot
Note!
Do not remove the dust plug from the SFP slot if you are not installing the transceiver at this time. The dust plug protects hardware from dust contamination.
2.
Position the SFP transceiver with the handle on top, see the following figure.
3.
Locate the triangular marking in the slot and align it with the bottom of the transceiver.
4.
Insert the SFP transceiver into the slot until it clicks into place.
5.
Make sure the module is seated correctly before sliding the module into the slot.
A click sounds when it is locked in place.
Handle
Figure 2.4 Installing an SFP Transceiver
Note!
If you are attaching fiber optic cables to the transceiver, continue with the following step. Otherwise, repeat the previous steps to install the remaining SFP transceivers in the device.
6.
Remove the protective plug from the SFP transceiver.
Note!
Do not remove the dust plug from the transceiver if you are not installing the fiber optic cable at this time. The dust plug protects hardware from dust contamination.
EKI-9628G User Manual 11
7.
Insert the fiber cable into the transceiver. The connector snaps into place and locks.
Figure 2.5 Attaching a Fiber Optic Cable to a Transceiver
8.
Repeat the previous procedures to install any additional SFP transceivers in the switch.
The fiber port is now setup.
2.6.2
Removing SFP Modules
To disconnect an LC connector, use the following guidelines:
1.
Press down and hold the locking clips on the upper side of the optic cable.
2.
Pull the optic cable out to release it from the transceiver.
Figure 2.6 Removing a Fiber Optic Cable to a Transceiver
3.
Hold the handle on the transceiver and pull the transceiver out of the slot.
Handle
Figure 2.7 Removing an SFP Transceiver
Note!
Replace the dust plug on the slot if you are not installing a transceiver.
The dust plug protects hardware from dust contamination.
12 EKI-9628G User Manual
2.7
Connecting the Switch to Ethernet Ports
2.7.1
RJ45 Ethernet Cable Wiring
For RJ45 connectors, data-quality, twisted pair cabling (rated CAT5 or better) is recommended. The connector bodies on the RJ45 Ethernet ports are metallic and connected to the GND terminal. For best performance, use shielded cabling. Shielded cabling may be used to provide further protection.
Straight-thru Cable Wiring
Pin 1
Pin 2
Pin 3
Pin 6
Pin 1
Pin 2
Pin 3
Pin 6
Cross-over Cable Wiring
Pin 1
Pin 2
Pin 3
Pin 6
Pin 3
Pin 6
Pin 1
Pin 2
8
1
Figure 2.8 Ethernet Plug & Connector Pin Position
Maximum cable length: 100 meters (328 ft.) for 10/100/1000BaseT.
EKI-9628G User Manual 13
2.8
Connecting the Switch to Console Port
The industrial switch supports a secondary means of management. By connecting the RJ45 to RS232 serial cable between a COM port on your PC (9-pin D-sub female) and the switch’s RJ45 (RJ45) port, a wired connection for management can be established.
To terminal or PC
Figure 2.9 Serial Console Cable
5
9
1
6
Figure 2.10 DB 9 Pin Position
DB9 Connector
5
3
NC
NC
NC
NC
2
NC
RJ45 Connector
1 Orange/White
2 Orange
3 Green/White
4 Blue
5 Blue/White
6 Green
7 Brown/White
8 Brown
RXD
TXD
RTS
CTS
DTR
DSR
GND
DB9
Female
4
6
5
7
8
2
3
RJ45
Male
5
4
7
2
8
1
3
6
TXD
RXD
NC
NC
NC
NC
GND
GND
Figure 2.11 Pin Assignment
To console port
14 EKI-9628G User Manual
2.9
Power Supply Installation
2.9.1
Overview
Warning! Power down and disconnect the power cord before servicing or wiring the switch.
Caution! Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power components except those specifically designated for the switch device.
Caution! Disconnect the power cord before installation or cable wiring.
The switches can be powered by using the same DC source used to power other devices. A DC voltage range of 12 to 48 VDC must be applied between the V1+ terminal and the V1- terminal (PW1), see the following illustrations. A Class 2 power supply is required to maintain a UL60950 panel listing. The chassis ground screw terminal should be tied to the panel or chassis ground. A redundant power configuration is supported through a secondary power supply unit to reduce network down time as a result of power loss.
EKI-9612G supports 12 to 48 VD. Dual power inputs are supported and allow you to connect a backup power source.
Single DC Power Redundant DC Power
P2 P1 P2 P1
One DC Supply
Chassis
GND
(pane)
Dual DC Supplies
Chassis
GND
(pane)
Figure 2.12 Power Wiring for EKI-9628G
EKI-9628G User Manual 15
2.9.2
Considerations
Take into consideration the following guidelines before wiring the device:
The Terminal Block (CN1) is suitable for 12-24 AWG (3.31 - 0.205 mm
2
). Torque value 7 lb-in.
The cross sectional area of the earthing conductors shall be at least 3.31 mm
2
.
Calculate the maximum possible current for each power and common wire.
Make sure the power draw is within limits of local electrical code regulations.
For best practices, route wiring for power and devices on separate paths.
Do not bundle together wiring with similar electrical characteristics.
Make sure to separate input and output wiring.
Label all wiring and cabling to the various devices for more effective management and servicing.
Note!
Routing communications and power wiring through the same conduit may cause signal interference. To avoid interference and signal degradation, route power and communications wires through separate conduits.
2.9.3
Grounding the Device
Caution! Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power components except those specifically designated for the switch device.
Caution! Before connecting the device properly ground the device. Lack of a proper grounding setup may result in a safety risk and could be hazardous.
Caution! Do not service equipment or cables during periods of lightning activity.
16 EKI-9628G User Manual
Caution! Do not service any components unless qualified and authorized to do so.
Caution! Do not block air ventilation holes.
Electromagnetic Interference (EMI) affects the transmission performance of a device.
By properly grounding the device to earth ground through a drain wire, you can setup the best possible noise immunity and emissions.
Console DI / DO
Drain Wire with Lug
Connection to
Grounding Point
Figure 2.13 Grounding Connection
By connecting the ground terminal by drain wire to earth ground the switch and chassis can be ground.
Note!
Before applying power to the grounded switch, it is advisable to use a volt meter to ensure there is no voltage difference between the power supply’s negative output terminal and the grounding point on the switch.
2.9.4
Wiring a Relay Contact
The following section details the wiring of the relay output. The terminal block on the
EKI-9628G is wired and then installed onto the terminal receptor located on the EKI-
9628G.
P-Fail
Figure 2.14 Terminal Receptor: Relay Contact
The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and two for a fault circuit.
EKI-9628G User Manual 17
2.9.5
Wiring the Power Inputs
Caution! Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power components except those specifically designated for the switch device.The temperature rating of the Input Connection
Cable must be higher than 90
°
C.
Warning! Power down and disconnect the power cord before servicing or wiring the switch.
There are two power inputs for normal and redundant power configurations. The power input 2 is used for wiring a redundant power configuration. See the following for terminal block connector views.
PWR1 PWR2
V1V1+ V2V2+
Figure 2.15 Terminal Receptor: Power Input Contacts
To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before proceeding.
1.
Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and loosen the screws.
2.
Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting up power redundancy, connect PW2 in the same manner.
3.
Tighten the wire-clamp screws to secure the DC wires in place.
PWR1
PWR2
Loosening
Wire-clamp
Screws
PWR1
PWR2
Installing DC
Wires
Securing
Wireclamp Screws
Figure 2.16 Installing DC Wires in a Terminal Block
18 EKI-9628G User Manual
2.10
Reset Button
Reset configuration to factory default:
Press and hold Reset button for 5 seconds.
System reboot:
Press and hold Reset button for 3 seconds.
Note!
Do NOT power off the Ethernet switch when loading default settings.
EKI-9628G User Manual 19
Chapter
3
Configuration Utility
3
3.1
First Time Setup
3.1.1
Overview
The Industrial Ethernet Managed Switch is a configurable device that facilitates the interconnection of Ethernet devices on an Ethernet network. This includes computers, operator interfaces, I/O, controllers, RTUs, PLCs, other switches/hubs or any device that supports the standard IEEE 802.3 protocol.
This switch has all the capabilities of a store and forward Ethernet switch plus advanced management features such as SNMP, RSTP and port mirroring. This manual details how to configure the various management parameters in this easy to use switch.
3.1.2
Introduction
To take full advantage of all the features and resources available from the switch, it must be configured for your network.
The switch implements Rapid Spanning Tree Protocol (RSTP) and Simple Network
Management Protocol (SNMP) to provide most of the services offered by the switch.
Rapid Spanning Tree Protocol allows managed switches to communicate with each other to ensure that there exists only one active route between each pair of network nodes and provides automatic failover to the next available redundant route. A brief explanation of how RSTP works is given in the Spanning Tree section.
The switch is capable of communicating with other SNMP capable devices on the network to exchange management information. This statistical/derived information from the network is saved in the Management Information Base (MIB) of the switch.
The MIB is divided into several different information storage groups. These groups will be elaborated in detail in the Management and SNMP information section of this document. The switch implements Internet Group Management Protocol (IGMP) to optimize the flow of multicast traffic on your network.
The switch supports both port-based and tag-based Virtual LANs for flexible integration with VLAN-aware networks with support for VLAN-unaware devices.
3.1.3
Administrative Interface Access
There are several administrative interfaces to the switch:
1.
A graphical web interface accessible via the switch's built-in web server. Both
HTTP and secure HTTPS with SSL are supported.
Note!
This is the recommended method for managing the switch.
2.
A terminal interface via the RS232/USB port or over the network using telnet or
Secure Shell (SSH).
3.
An SNMP interface can be used to read/write many settings.
4.
Command Line Interface (CLI) can be used to read/write most settings. Initial setup must be done using an Ethernet connection (recommended) or the serial port.
EKI-9628G User Manual 21
3.1.4
Using the Graphical (Web) Interface
The graphical interface is provided via a web server in the switch and can be accessed via a web browser such as Opera, Mozilla, or Internet Explorer.
Note!
JavaScript must be supported and enabled in your browser for the graphical interface to work correctly.
HTTP and HTTPS (secure HTTP) are supported for access to the web server. By default, both protocols are enabled. Either or both may be disabled to secure the switch. (See the Remote Access Security topic in this section.)
To access the graphical interface, enter a URL like HTTP://192.168.1.1 in your browser's address bar. Replace “http” with “https” to use secure http and replace
“192.168.1.1” with your switch's IP address if you've changed it from the factory default.
The web server in the switch uses a signed security certificate. When you access the server via https, you may see a warning dialog indicating that the certificate was signed by an unknown authority. This is expected and to avoid this message in the future you can choose to install the certificate on your computer.
Note!
This manual describes and depicts the web user interface in detail. The terminal interface is not specifically shown but is basically the same.
3.1.5
Configuring the Switch for Network Access
To control and monitor the switch via the network, it must be configured with basic network settings, including an IP address and subnet mask. Refer to the quick start guide in Section 1 for how to initially access your switch.
To configure the switch for network access, select [Add Menu Address Here] to reach the System Settings menu. The settings in this menu control the switch's general network configuration.
DHCP Enabled/Disabled: The switch can automatically obtain an IP address from a server using the Dynamic Host Configuration Protocol (DHCP). This can speed up initial set up, as the network administrator does not have to find an open IP address.
IP Address and subnet mask configuration: The IP address for the switch can be changed to a user-defined address along with a customized subnet mask to separate subnets.
Note!
Advanced users can set the IP address to 0.0.0.0 to disable the use of an IP address for additional security. However, any features requiring an
IP address (i.e., web interface, etc.) will no longer be available.
Default Gateway Selection: A Gateway Address is chosen to be the address of a router that connects two different networks. This can be an IP address or a
Fully Qualified Domain Name (FQDN) such as “domainname.org”.
NTP Server: The IP address or domain name of an NTP (Network Time Protocol) server from which the switch may retrieve the current time at startup.
Please note that using a domain name requires that at least one domain name server be configured.
22 EKI-9628G User Manual
3.1.6
Configuring the Ethernet Ports
The switch comes with default port settings that should allow you to connect to the
Ethernet Ports with out any necessary configuration. Should there be a need to change the name of the ports, negotiation settings or flow control settings, you can do this in the Port Configuration menu. Access this menu by selecting Setup from the
Main menu, and then selecting Main Settings.
Port Name: Each port in the managed switch can be identified with a custom name. Specify a name for each port here.
Admin: Ports can be enabled or disabled in the managed switch. For ports that are disabled, they are virtually non-existent (not visible in terms of switch operation or spanning tree algorithm). Choose to enable or disable a port by selecting
Enabled or Disabled, respectively.
Negotiation: All copper ports and gigabit fiber ports in the managed switch are capable of autonegotiation such that the fastest bandwidth is selected. Choose to enable auto-negotiation or use fixed settings. 100Mbps Fiber ports are Fixed speed only.
Speed/Duplex/Flow Control: The managed switch accepts three local area network Ethernet Standards. The first standard, 10BASE-T, runs 10Mbps with twisted pair Ethernet cable between network interfaces. The second local area network standard is 100BASE-T, which runs at 100Mbps over the same twisted pair Ethernet cable. Lastly, there is 100BASE-F, which enables fast Ethernet
(100Mbps) over fiber.
These options are available:
10h–10 Mbps, Half Duplex
10f –10 Mbps, Full Duplex
100h–100 Mbps, Half Duplex
100f –100 Mbps, Full Duplex
1000f–1000 Mbps, Full Duplex
On managed switches with gigabit combination ports, those ports with have two rows, a standard row of check boxes and a row labeled “SFP” with radio buttons. The
SFP setting independently sets the speed at which a transceiver will operate if one is plugged in. Otherwise, the switch will use the fixed Ethernet port and the corresponding settings for it.
Note!
When 100f is selected for the SFP of a gigabit combination port, the corresponding fixed Ethernet jack will be disabled unless it is changed back to 1000F.
EKI-9628G User Manual 23
3.2
Command Line Interface Configuration
3.2.1
Introduction to Command-Line Interface (CLI)
The command-line interface (CLI) is constructed with an eye toward automation of
CLI-based configuration. The interaction is modeled on that used in many Internet protocols such as Telnet, FTP, and SMTP. After each command is entered and processed, the switch will issue a reply that consists of a numeric status code and a human-readable explanation of the status.
The general format of commands is: section parameter [value] where:
section is used to group parameters.
parameter will specify the parameter within the section. For example, the network section will have parameters for DHCP, IP address, subnet mask, and default gateway.
value is the new value of the parameter. If value is omitted, the current value is displayed.
Please note that new values will not take effect until explicitly committed.
Sections and parameter names are case sensitive (e.g., “Network” is not the same as
“network”).
Note!
Any commands in the CLI Commands section of this chapter, with the exception of the global commands, must be prefaced with the name of the section they are in. For example, to change the IP address of the switch, you would type: network address <newIP>
3.2.2
Accessing the CLI
To access the CLI interface, establish Ethernet or serial connectivity to the switch.
To connect by Ethernet, open a command prompt window and type: telnet <switchip> (where <switchip> is the IP address of the switch)
At the login prompt, type “cli” for the username and “admin” for the password. The switch will respond with “Managed switch configuration CLI ready”.
24 EKI-9628G User Manual
3.3
Web Browser Configuration
The switch has an HTML based user interface embedded in the flash memory. The interface offers an easy to use means to manage basic and advanced switch functions. The interface allows for local or remote switch configuration anywhere on the network.
The interface is designed for use with [Internet Explorer (6.0), Chrome, Firefox].
3.3.1
Preparing for Web Configuration
The interface requires the installation and connection of the switch to the existing network. A PC also connected to the network is required to connect to the switch and access the interface through a web browser. The required networking information is provided as follows:
IP address: 192.168.1.1
Subnet mask: 255.255.255.0
Default gateway: 192.168.1.254
User name: admin
Password: admin
3.3.2
System Login
Once the switch is installed and connected, power on the switch. The following information guides you through the logging in process.
1.
Launch your web browser on the PC.
2.
In the browser’s address bar, type the switch’s default IP address (192.168.1.1).
The login screen displays.
3.
Enter the user default name and password (admin / admin).
4.
Click OK on the login screen to log in.
The main interface displays.
EKI-9628G User Manual 25
Chapter
4
Managing Switch
4
4.1
Log In
To access the login window, connect the device to the network, see “Connecting the
Switch to Ethernet Ports” on page 13. Once the switch is installed and connected,
power on the switch see the following procedures to log into your switch.
When the switch is first installed, the default network configuration is set to DHCP enabled. You will need to make sure your network environment supports the switch setup before connecting it to the network.
1.
Launch your web browser on a computer.
2.
In the browser’s address bar type in the switch’s default IP address
(192.168.1.1). The login screen displays.
3.
Enter the default user name and password (admin/admin) to log into the management interface. You can change the default password after you have successfully logged in.
4.
Click Login to enter the management interface.
Figure 4.1 Login Screen
4.2
Recommended Practices
One of the easiest things to do to help increase the security posture of the network infrastructure is to implement a policy and standard for secure management. This practice is an easy way to maintain a healthy and secure network.
After you have performed the basic configurations on your switches, the following is a recommendation which is considered best practice policy.
4.2.1
Changing Default Password
In keeping with good management and security practices, it is recommended that you change the default password as soon as the device is functioning and setup correctly. The following details the necessary steps to change the default password.
To change the password:
1.
Navigate to Tools > User Account.
2.
From the User drop-down menu, select the Admin (default) account.
3.
In the User Name field, enter admin for this account. It is not necessary to change the user name, however, a change in the default settings increases the security settings.
4.
In the Password field, type in the new password. Re-type the same password in the Retype Password field.
EKI-9628G User Manual 27
5.
Click Apply to change the current account settings.
Figure 4.2 Changing a Default Password
After saving all the desired settings, perform a system save (Tools > Save Configu-
ration). The changes are saved.
4.3
Monitoring
4.3.1
Device Information
The Device Information menu lists information, such as: System Name, System
Location, MAC Address, Firmware version, and more, pertaining to the system. The information is for review only. To modify the device information, see the respective item within the user interface.
To access this page, click Monitoring > Device Information.
Figure 4.3 Monitoring > Device Information
28 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item
System Name
System Location
System Contact
MAC Address
IP Address
Subnet Mask
Gateway
Loader Version
Loader Date
Firmware Version
Firmware Date
System Object ID
System Up Time
Description
Click Switch to enter the system name: up to 128 alphanumeric characters (default is Switch).
Click Default to enter the location: up to 256 alphanumeric characters
(default is Default).
Click Default to enter the contact person: up to 128 alphanumeric characters (default is Default).
Displays the MAC address of the switch.
Displays the assigned IP address of the switch.
Displays the assigned subnet mask of the switch.
Displays the assigned gateway of the switch.
Displays the current loader version of the switch.
Displays the current loader build date of the switch.
Displays the current firmware version of the switch.
Displays the current firmware build date of the switch.
Displays the base object ID of the switch.
Displays the time since the last switch reboot.
4.3.2
Logging Message
The Logging Message Filter page allows you to enable the display of logging message filter.
To access this page, click Monitoring > Logging Message.
Figure 4.4 Monitoring > Logging Message
The following table describes the items in the previous figure.
Item
Target
Description
Click the drop-down menu to select a target to store the log messages.
Buffered: Store log messages in RAM. All log messages are cleared after system reboot.
File: Store log messages in a file.
EKI-9628G User Manual 29
Item Description
Severity
Category
View
The setting allows you to designate a severity level for the Logging
Message Filter function.
Click the drop-down menu to select the severity level target setting.
The level options are:
emerg: Indicates system is unusable. It is the highest level of severity.
alert: Indicates action must be taken immediately.
crit: Indicates critical conditions.
error: Indicates error conditions.
warning: Indicates warning conditions.
notice: Indicates normal but significant conditions.
info: Indicates informational messages.
debug: Indicates debug-level messages.
Click the drop-down menu to select the category level target setting.
Click View to display all Logging Information and Logging Message information.
Click Refresh to update the screen.
Click Clear buffered messages to clear the logging buffer history list.
Refresh
Clear buffered messages
The ensuing table for Logging Information table settings are informational only and display the following: Target, Severity and Category.
The ensuing table for Logging Message table settings are informational only and display the following: No., Time Stamp, Category, Severity and Message.
4.3.3
Port Monitoring
Port Network Monitor is a bandwidth and network monitoring tool for the purpose of capturing network traffic and measuring of network throughput. The monitoring functionality includes listing of port statistics as well as port utilization.
4.3.3.1
Port Statistics
To access this page, click Monitoring > Port Monitoring > Port Statistics.
Figure 4.5 Monitoring > Port Monitoring > Port Statistics
The following table describes the items in the previous figure.
Item
Port
Description
Click the drop-down menu to select a port and its captured statistical setting values.
Click Clear to clear the counter selections.
Clear
The ensuing table for IF MIB Counters settings are informational only and display the following: ifInOctets, ifInUcastPkts, ifInNUcastPkts, ifInDiscards, ifOutOctets, ifOutUcastPkts, ifOutNUcastPkts, ifOutDiscards, ifInMulticastPkts, ifInBroadcastPkts, ifOutMulticastPkts and ifOutBroadcastPkts.
30 EKI-9628G User Manual
The ensuing table for Ether-Like MIB Counters settings are informational only and display the following: dot3StatsAlignmentErrors, dot3StatsFCSErrors, dot3StatsSingleCollisionFrames, dot3StatsMultipleCollisionFrames, dot3StatsDeferredTransmissions, dot3StatsLateCollisions, dot3StatsExcessiveCollisions, dot3StatsFrameTooLongs, dot3StatsSymbolErrors, dot3ControlInUnknownOpcodes, dot3InPauseFrames and dot3OutPauseFrames.
The ensuing table for Rmon MIB Counters settings are informational only and display the following: etherStatsDropEvents, etherStatsOctets, etherStatsPkts, ether-
StatsBroadcastPkts, etherStatsMulticastPkts, etherStatsCRCAlignErrors, etherStatsUnderSizePkts, etherStatsOverSizePkts, etherStatsFragments, ether-
StatsJabbers, etherStatsCollisions, etherStatsPkts64Octets, etherStatsPkts65to127Octets, etherStatsPkts128to255Octets, etherStatsPkts256to511Octets, etherStatsPkts512to1023Octets and etherStatsPkts1024to1518Octets.
4.3.3.2
Port Utilization
To access this page, click Monitoring > Port Monitoring > Port Utilization.
Figure 4.6 Monitoring > Port Monitoring > Port Utilization
The following table describes the items in the previous figure.
Item
Refresh period
IFG
Description
Click the drop-down menu to select and designate a period (second intervals) to refresh the information (TX and RX) listings.
Click the drop-down menu to enable or disable the Interframe Gap
(IFG) statistic.
4.3.4
Link Aggregation
The Link Aggregation function provides LAG information for each trunk. It displays membership status, link state and membership type for each port.
To access this page, click Monitoring > Link Aggregation.
EKI-9628G User Manual
Figure 4.7 Monitoring > Link Aggregation
31
The ensuing table for Link Aggregation Group Status settings are informational only and display the following: LAG, Name, Type, Link State, Active Member and
Standby Member.
The ensuing table for LACP Information settings are informational only and display the following: LAG, Port, PartnerSysId, PnKey, AtKey, Sel, Mux, Receiv, PrdTx,
AtState and PnState.
4.3.5
LLDP Statistics
The LLDP Statistics page displays both the global and port LLDP statistics.
To access this page, click Monitoring > LLDP Statistics.
Figure 4.8 Monitoring > LLDP Statistics
The following table describes the items in the previous figure.
Item
Clear
Refresh
Description
Click Clear to reset the LLDP Statistics for all the interfaces.
Click Refresh to update the data on the screen with the present state of the data in the switch.
The ensuing table for LLDP Global Statistics settings are informational only and display the following: Insertions, Deletions, Drops and Age Outs.
The ensuing table for LLDP Port Statistics settings are informational only and display the following: Port, TX Frames (Total), RX Frames (Total, Discarded and Errors),
RX TLVs (Discarded and Unrecognized) and RX Ageouts (Total).
32 EKI-9628G User Manual
4.3.6
IGMP Statistics
The IGMP Statistics function displays statistical package information for IP multicasting.
To access this page, click Monitoring > IGMP Statistics.
Figure 4.9 Monitoring > IGMP Statistics
The following table describes the items in the previous figure.
Item
Clear
Refresh
Description
Click Clear to refresh IGMP Statistics of all the interfaces.
Click Refresh to update the data on the screen with the present state of the data in the switch.
The ensuing table for IGMP Statistics settings are informational only and display the following: Total RX, Valid RX, Invalid RX, Other RX, Leave RX, Report RX, General
Query RX, Special Group Query RX, Special Group & Source Query RX, Leave TX,
Report TX, General Query TX, Special Group Query TX and Special Group & Source
Query TX.
EKI-9628G User Manual 33
4.3.7
IGMP Statistics
The IGMP Statistics function displays statistical package information for IP multicasting.
To access this page, click Monitoring > MLD Statistics.
Figure 4.10 Monitoring > MLD Statistics
The following table describes the items in the previous figure.
Item
Clear
Refresh
Description
Click Clear to refresh MLD Statistics of all the interfaces.
Click Refresh to update the data on the screen with the present state of the data in the switch.
The ensuing table for MLD Statistics settings are informational only and display the following: Total RX, Valid RX, Invalid RX, Other RX, Leave RX, Report RX, General
Query RX, Special Group Query RX, Special Group & Source Query RX, Leave TX,
Report TX, General Query TX, Special Group Query TX, and Special Group &
Source Query TX.
34 EKI-9628G User Manual
4.4
System
4.4.1
IP Settings
The IP Settings menu allows you to select a static or DHCP network configuration.
The Static displays the configurable settings for the static option.
To access this page, click System > IP Settings.
Figure 4.11 System > IP Settings
The following table describes the items in the previous figure.
Item
Interface
Mode
IP Address
Subnet Mask
Gateway
Description
Click the drop-down menu to select an available interface option to configure its settings.
Click the radio button to select the IP Address Setting mode: Static or
DHCP.
Enter a value to specify the IP address of the interface. The default is
192.168.1.1.
Enter a value to specify the IP subnet mask for the interface. The default is 255.255.255.0.
Enter a value to specify the default gateway for the interface. The default is 192.168.1.254.
Click Apply to save the values and update the screen.
Apply
The ensuing table for IP Address Information settings are informational only and display the following: DHCP State, Static IP Address, Static Subnet Mask, Static
Gateway, Static DNS Server 1 and Static DNS Server 2.
4.4.2
IPv6 Settings
To access this page, click System > IPv6 Settings.
EKI-9628G User Manual
Figure 4.12 System > IPv6 Settings
35
The following table describes the items in the previous figure.
Item
Interface
IPv6 Address
Gateway
Apply
Description
Click the drop-down menu to select an available interface option to configure its settings.
Enter the IPv6 address for the system.
Enter the gateway address for the system.
Click Apply to save the values and update the screen.
The ensuing table for IPv6 Information settings are informational only and display the following: Auto Configuration, IPv6 In Use Address, IPv6 In Use Router, IPv6
Static Address, IPv6 Static Router and DHCPv6 Client.
4.4.3
System Time
To access this page, click System > System Time.
Figure 4.13 System > System Time
The following table describes the items in the previous figure.
Item
Enable SNTP
Description
Click the radio button to enable or disable the SNTP.
36 EKI-9628G User Manual
Item Description
SNTP/NTP Server
Address
SNTP Port
Manual Time
Time Zone
Enter the address of the SNTP server. This is a text string of up to 64 characters containing the encoded unicast IP address or hostname of a SNTP server. Unicast SNTP requests will be sent to this address. If this address is a DNS hostname, then that hostname should be resolved into an IP address each time a SNTP request is sent to it.
Enter the port on the server to which SNTP requests are to be sent.
Allowed range is 1 to 65535 (default: 123).
Click the drop-down menus to set local date and time of the system.
Click the drop-down menu to select a system time zone.
Daylight Saving Time Click the drop-down menu to enable or disable the daylight saving time settings.
Daylight Saving Time
Offset
Enter the offsetting variable in seconds to adjust for daylight saving time.
Recurring From
Recurring To
Click the drop-down menu to designate the start date and time for daylight saving time.
Click the drop-down menu to designate the end date and time for daylight saving time.
Non-Recurring From Click the drop-down menu to designate a start date and time for a non-recurring daylight saving time event.
Non-Recurring To Click the drop-down menu to designate the end date and time for a non-recurring daylight saving time event.
Apply Click Apply to save the values and update the screen.
The ensuing table for System Time Information settings are informational only and display the following: Current Date/Time, SNTP, SNTP Server Address, SNTP Server
Port, Time zone, Daylight Saving Time, Daylight Saving Time Offset, From and To.
4.4.4
Network Port
To access this page, click System > Network Port.
Figure 4.14 System > Network Port
The following table describes the items in the previous figure.
Item
HTTP
HTTPS
TELNET
Description
Enter the value to designate the port number for the HTTP protocol
(default: 80).
Enter the value to designate the port number for the HTTPS protocol
(default: 443).
Enter the value to designate the port number for the Telnet protocol
(default: 23).
EKI-9628G User Manual 37
Item
SSH
Description
Enter the value to designate the port number for the Secure Shell protocol (default: 22).
Click Apply to save the values and update the screen.
Apply
The ensuing table for Network Port Information settings are informational only and display the following: HTTP, HTTPS, TELNET and SSH.
4.5
L2 Switching
4.5.1
Port Configuration
Port Configuration describes how to use the user interface to configure LAN ports on the switch.
To access this page, click L2 Switching > Port Configuration.
Figure 4.15 L2 Switching > Port Configuration
The following table describes the items in the previous figure.
Item
Port
Enabled
Speed
Duplex
Flow Control
Fiber Port
Enabled
Description
Click the drop-down menu to select the port for the L2 Switch setting
(GE1 to GE8).
Click the radio-button to enable or disable the Port Setting function.
Click the drop-down menu to select the port speed: Auto, Auto-10M,
Auto-100M, Auto-1000M, Auto-10/100M, 10M, 100M, or 1000M.
Click the drop-down menu to select the duplex setting: Half or Full.
Click the radio button to enable or disable the flow control function.
Click the drop-down menu to designate the port to be used by the fiber ports (GE9 to GE12).
Click the radio-button to enable or disable the fiber port setting function.
38 EKI-9628G User Manual
Item
Speed
Fiber Duplex
Flow Control
Description
Click the drop-down menu to select the fiber port speed: Auto, Auto-
10M, Auto-100M, Auto-1000M, Auto-10/100M, 10M, 100M, or 1000M.
Click the drop-down menu to select the fiber duplex setting: Half or
Full.
Click the radio button to enable or disable the flow control for the fiber port function.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Port Status settings are informational only and display the following: Port, Edit (click to enter description), Enable State, Link Status, Speed,
Duplex, FlowCtrl Config, and FlowCtrl Status.
4.5.2
Port Mirror
Port mirroring function allows the sending of a copy of network packets seen on one switch port to a network monitoring connection on another switch port. Port mirroring can be used to analyze and debug data or diagnose errors on a network or to mirror either inbound or outbound traffic (or both).
There are no preset values in the Port Mirror. The displayed values do not represent the actual setting values.
To access this page, click L2 Switching > Port Mirror.
Figure 4.16 L2 Switching > Port Mirror
The following table describes the items in the previous figure.
Item Description
Session ID Click the drop-down menu to select a port mirroring session from the list. The number of sessions allowed is platform specific.
Monitor session state Click the drop-down menu to enable or disable the session mode for a selected session ID.
Destination Port
Allow-ingress
Click the drop-down menu to select the destination port and receive all the traffic from configured mirrored port(s).
Click the drop-down menu to enable or disable the Allow-ingress function.
Sniffer RX Ports
Sniffer TX Ports
Apply
Enter the variable to define the RX port.
Enter the variable to define the TX port.
Click Apply to save the values and update the screen.
EKI-9628G User Manual 39
The ensuing table for Mirror Status settings are informational only and display the following: Session ID, Destination Port, Ingress State, Source TX Port and Source
RX Port.
4.5.3
Link Aggregation
Link Aggregation is a method for combining multiple network connections in parallel in order to increase throughput beyond the capability of a single connection, and to provide redundancy in case one of the links should fail.
4.5.3.1
Load Balance
The Load Balancing page allows you to select between a MAC Address or IP/MAC
Address algorithm for the even distribution of IP traffic across two or more links.
To access this page, click L2 Switching > Link Aggregation > Load Balance.
Figure 4.17 L2 Switching > Link Aggregation > Load Balance
The following table describes the items in the previous figure.
Item
Load Balance Algorithm
Apply
Description
Select the radio button to select the Load Balance Setting: MAC
Address or IP/MAC Address.
Click Apply to save the values and update the screen.
The ensuing table for Load Balance Information settings are informational only and display the following: Load Balance Algorithm.
4.5.3.2
LAG Management
Link aggregation is also known as trunking. It is a feature available on the Ethernet gateway and is used with Layer 2 Bridging. Link aggregation allows for the logical merging of multiple ports into a single link.
To access this page, click L2 Switching > Link Aggregation > LAG Management.
Figure 4.18 L2 Switching > Link Aggregation > LAG Management
The following table describes the items in the previous figure.
Item
LAG
Name
Description
Click the drop-down menu to select the designated trunk group:
Trunk 1 ~8.
Enter an entry to specify the LAG name.
40 EKI-9628G User Manual
Item Description
Type
Ports
Click the radio button to specify the type mode: Static or LACP.
Click the drop-down menu to select designated ports: FE1-8 or GE1-
2.
Click Apply to save the values and update the screen.
Apply
The ensuing table for LAG Management Information settings are informational only and display the following: LAG, Name, Type, Link State, Active Member, Standby
Member, Edit (click to modify the settings) and Clear (click to load default settings).
4.5.3.3
LAG Port Settings
The LAG Port Settings page allows you to enable or disable, set LAG status, speed and flow control functions.
In this example we will configure a LAG between the following switches:
To access this page, click L2 Switching > Link Aggregation > LAG Port Settings.
Figure 4.19 L2 Switching > Link Aggregation > LAG Port Settings
The following table describes the items in the previous figure.
Item
LAG Select
Enabled
Speed
Flow Control
Description
Click the drop-down menu to select a predefined LAG trunk definition:
LAG 1-8.
Click the radio button to enable or disable the LAG Port.
Click the drop-down menu to select the port speed: Auto, Auto-10M,
Auto-100M, Auto-1000M, Auto-10/100M, 10M, 100M, or 1000M.
Click the radio button to enable or disable the Flow Control for the
LAG Port.
Click Apply to save the values and update the screen.
Apply
The ensuing table for LAG Port Status settings are informational only and display the following: LAG, Description, Port Type, Enable State, Link Status, Speed, Duplex,
FlowCtrl Config and FlowCtrl Status.
4.5.3.4
LACP Priority Settings
The LACP Priority Settings page allows you to configure the system priority for LACP.
To access this page, click L2 Switching > Link Aggregation > LACP Priority Set-
tings.
Figure 4.20 L2 Switching > Link Aggregation > LACP Priority Settings
EKI-9628G User Manual 41
The following table describes the items in the previous figure.
Item
System Priority
Apply
Description
Enter the value (1-65535) to designate the LACP system priority.
Click Apply to save the values and update the screen.
The ensuing table for LACP Information settings are informational only and display the following: System Priority.
4.5.3.5
LACP Port Settings
Link Aggregation Control Protocol (LACP) provides a method to control the bundling of several physical ports together to form a single logical channel. By configuring the
LACP function, the switch can negotiate an automatic bundling of links by sending
LACP packets to the peer device (also implementing LACP).
To access this page, click L2 Switching > Link Aggregation > LACP Port Settings.
Figure 4.21 L2 Switching > Link Aggregation > LACP Port Settings
The following table describes the items in the previous figure.
Item
Port Select
Priority
Timeout
Mode
Description
Select a port for the LACP Port Settings. The listed available settings are: FE1-FE8, GE1-GE2.
However, the available settings are dependent on the connected
LACP device and may not be listed as displayed in the current figure.
Enter a variable (1 to 65535) to assign a priority to the defined port selection.
Click the radio button to select a long or short timeout period.
Click the radio button to select the setting mode: Active or Passive.
Active: Enables LACP unconditionally.
Passive: Enables LACP only when an LACP device is detected
(default state).
Click Apply to save the values and update the screen.
Apply
The ensuing table for LACP Port Information settings are informational only and display the following: Port Name, Priority, Timeout and Mode.
42 EKI-9628G User Manual
4.5.4
802.1Q VLAN
The 802.1Q VLAN feature allows for a single VLAN to support multiple VLANs. With the 802.1Q feature you can preserve VLAN IDs and segregate different VLAN traffic.
The 802.1Q VLAN tag feature encapsulates the 802.1Q VLAN tagging within another
802.1Q VLAN tag. The outer tag is assigned following the AP group, while the inner
VLAN ID is assigned dynamically by the AAA server.
4.5.4.1
VLAN Management
The management of VLANs is available through the VLAN Settings page. Through this page you can add or delete VLAN listings and add a prefix name to an added entry.
To access this page, click L2 Switching > 802.1Q VLAN > VLAN Management.
Figure 4.22 L2 Switching > 802.1Q VLAN > VLAN Management
The following table describes the items in the previous figure.
Item Description
VLAN list Enter the name of the VLAN entry to setup.
VLAN Action Click the radio button to add or delete the VLAN entry (VLAN ID or
VLAN list) designated in the following field.
VLAN Name Prefix Enter the prefix to be used by the VLAN list entry in the previous field.
Apply Click Apply to save the values and update the screen.
The ensuing table for VLAN Table settings are informational only and display the following: VLAN ID, VLAN Name, VLAN Type and Edit (click to enter VLAN name).
4.5.4.2
PVID Settings
The PVID Settings page allows you to designate a PVID for a selected port, define the accepted type and enable/disable the ingress filtering.
To access this page, click L2 Switching > 802.1Q VLAN > PVID Settings.
Figure 4.23 L2 Switching > 802.1Q VLAN > PVID Settings
EKI-9628G User Manual 43
The following table describes the items in the previous figure.
Item
Port Select
PVID
Accepted Type
Ingress Filtering
Description
Click the drop-down menu to select a port and edit its settings: FE1-
FE8, GE1-GE2, or Trunk1 - Trunk8.
Enter the VLAN ID you want assigned to untagged or priority tagged frames received on this port. The value ranges 1 to 4094. The default is 1.
Click the radio button to specify which frames to forward.
Tag Only discards any untagged or priority tagged frames.
Untag Only discards any tagged frames.
All accepts all untagged and tagged frames.
Whichever you select, VLAN tagged frames are forwarded in accordance with the IEEE 802.1Q VLAN standard. The default is All.
Click the radio button to specify how you want the port to handle tagged frames. If you enable Ingress Filtering, a tagged frame will be discarded if this port is not a member of the VLAN identified by the
VLAN ID in the tag. If you select Disabled, all tagged frames will be accepted. The default is Disabled.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Port VLAN Status settings are informational only and display the following: Port, Interface VLAN Mode, PVID, Accept Frame Type and Ingress Filtering.
44 EKI-9628G User Manual
4.5.4.3
Port to VLAN
The Port to VLAN page allows you to add a port to a VLAN and select the related parameters.
To access this page, click L2 Switching > 802.1Q VLAN > Port to VLAN.
Figure 4.24 L2 Switching > 802.1Q VLAN > Port to VLAN
The following table describes the items in the previous figure.
Item Description
Port Displays the assigned port to the entry.
Interface VLAN Mode Displays the assigned mode to the listed VLAN port.
Hybrid: Port hybrid model.
Access: Port hybrid model.
Trunk: Port hybrid model.
Tunnel: Port hybrid model.
Membership
Apply
Displays the assigned membership status of the port entry, options include: Forbidden, Excluded Tagged or Untagged.
Click Apply to save the values and update the screen.
EKI-9628G User Manual 45
4.5.4.4
Port-VLAN Mapping
To access this page, click L2 Switching > 802.1Q VLAN > Port-VLAN Mapping.
The ensuing table for the Port-VLAN Mapping Table settings are informational only and display the following: Port, Mode, Administrative VLANs and Operational VLANs.
4.5.4.5
VLAN Interface Management
To access this page, click L2 Switching > 802.1Q VLAN > VLAN Interface Man-
agement.
Figure 4.25 L2 Switching > 802.1Q VLAN > VLAN Interface Management
The following table describes the items in the previous figure.
Item
VLAN
Create
Description
Click Create to create a new VLAN interface.
The ensuing table for VLAN Interface Status settings are informational only and display the following: VLAN ID, Name and Delete (click Delete to delete the desired
VLAN interface).
4.5.5
Q-in-Q
Q-in-Q is commonly referred as VLAN stacking in which VLANs are nested by adding two tags to each frame instead of one. Network service provider and users both can use VLANs and makes it possible to have more than the 4094 separate VLANs allowed by 802.1Q.
There are three ways in which a machine can be connected to a network carrying double-tagged 802.1ad traffic:
via a untagged port, where both inner and outer VLANs are handled by the switch or switches (so the attached machine sees ordinary Ethernet frames);
via a single-tagged (tunnel) port, where the outer VLAN only is handled by the switch (so the attached machine sees single-tagged 802.1Q VLAN frames); or
via a double-tagged (trunk) port, where both inner and outer VLANs are handled by the attached machine (which sees double-tagged 802.1ad VLAN frames).
4.5.5.1
Global Settings
The Global Settings page allows you to set the outer VLAN Ethertype setting.
To access this page, click L2 Switching > Q-in-Q > Global Settings.
Figure 4.26 L2 Switching > Q-in-Q > Global Settings
46 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item
Outer VLAN
Ethertype
Apply
Description
Enter the outer VLAN handled by the switch giving the attached machine a single-tagged 802.1Q VLAN frame.
Click Apply to save the values and update the screen.
The ensuing table for QinQ Global Information settings are informational only and display the following: Outer VLAN Ethertype.
4.5.5.2
Port Settings
The Port Settings page allows you to define the outer PVID and outer mode for a selected port.
To access this page, click L2 Switching > Q-in-Q > Port Settings.
Figure 4.27 L2 Switching > Q-in-Q > Port Settings
The following table describes the items in the previous figure.
Item
Port Select
Outer PVID
Outer Mode
Description
Enter the switch port (part of VLAN configuration) to configure the selection as a tunnel port.
Enter the Port VLAN ID (PVID) to assigned the native VLAN ID. All untagged traffic coming in or out of the 802.1Q port is forwarded based on the PVID value
Click the drop-down menu to select between UNI or NNI role.
UNI: Selects a user-network interface which specifies communication between the specified user and a specified network.
NNI: Selects a network-to-network interface which specifies communication between two specified networks.
Click Apply to save the values and update the screen.
Apply
The ensuing table for QinQ Port Information settings are informational only and display the following: Port, Outer PVID and Outer Mode.
EKI-9628G User Manual 47
4.5.6
GARP
The Generic Attribute Registration Protocol (GARP) is a local area network (LAN) protocol. The protocol defines procedures for the registration and de-registration of attributes (network identifiers or addresses) by end stations and switches with each other.
4.5.6.1
GARP Settings
To access this page, click L2 Switching > GARP > GARP Settings.
Figure 4.28 L2 Switching > GARP > GARP Settings
The following table describes the items in the previous figure.
Item
Join Time
Leave Time
Leave All Time
Description
Enter a value to specify the time between the transmission of GARP
PDUs registering (or re-registering) membership for a VLAN or multicast group in centiseconds. Enter a number between 6 and 600. An instance of this timer exists for each GARP participant for each port.
Enter a value to specify the time to wait after receiving an unregister request for a VLAN or multicast group before deleting the associated entry, in centiseconds. This allows time for another station to assert registration for the same attribute in order to maintain uninterrupted service. Enter a number between 12 and 3000. An instance of this timer exists for each GARP participant for each port.
Enter a value to specify the Leave All Time controls how frequently
Leave All PDUs are generated. A LeaveAll PDU indicates that all registrations will shortly be deregistered. Participants will need to rejoin in order to maintain registration. The Leave All Period Timer is set to a random value in the range of LeaveAllTime to 1.5*LeaveAllTime. The timer is specified in centiseconds. Enter a number between 12 and
12000. An instance of this timer exists for each GARP participant for each port.
Click Apply to save the values and update the screen.
Apply
The ensuing table for GARP Information settings are informational only and display the following: Join Time, Leave Time and Leave All Time.
48 EKI-9628G User Manual
4.5.6.2
GVRP Settings
The GVRP Settings page allows you to enable or disable the GVRP (GARP VLAN
Registration Protocol or Generic VLAN Registration Protocol) protocol which facilitates control of virtual local area networks (VLANs) within a larger network.
To access this page, click L2 Switching > GARP > GVRP Settings.
Figure 4.29 L2 Switching > GARP > GVRP Settings
The following table describes the items in the previous figure.
Item
Status
Description
Click to enable or disable the GARP VLAN Registration Protocol administrative mode for the switch. The factory default is Disable.
Click Apply to save the values and update the screen.
Apply
The ensuing table for GVRP Information settings are informational only and display the following: GVRP.
4.5.7
802.3az EEE
The 802.3az Energy Efficient Ethernet (EEE) innovative green feature reduces energy consumption through intelligent functionality:
Traffic detection — Energy Efficient Ethernet (EEE) compliance
Inactive link detection
Inactive link detection function automatically reduces power usage when inactive links or devices are detected.
To access this page, click L2 Switching > 802.3az EEE.
Figure 4.30 L2 Switching > 802.3az EEE
The following table describes the items in the previous figure.
Item
Port Select
State
Description
Enter the port to setup the EEE function.
Click Enabled or Disabled to set the state mode of the port select setting.
Click Apply to save the values and update the screen.
Apply
The ensuing table for EEE Enable Status settings are informational only and display the following: Port and EEE State.
EKI-9628G User Manual 49
4.5.8
Multicast
Multicast forwarding allows a single packet to be forwarded to multiple destinations.
The service is based on L2 switch receiving a single packet addressed to a specific
Multicast address. Multicast forwarding creates copies of the packet, and transmits the packets to the relevant ports.
4.5.8.1
Multicast Filtering
The Multicast Filtering page allows for the definition of action settings when an unknown multicast request is received. The options include: Drop, Flood, or Router
Port.
To access this page, click L2 Switching > Multicast > Multicast Filtering.
Figure 4.31 L2 Switching > Multicast > Multicast Filtering
The following table describes the items in the previous figure.
Item
Unknown Multicast
Action
Apply
Description
Select the configuration protocol: Drop, Flood, or Router Port, to apply for any unknown multicast event.
Click Apply to save the values and update the screen.
The ensuing table for Properties Information settings are informational only and display the following: Unknown Multicast Action.
4.5.8.2
IGMP Snooping
IGMP Snooping is defined as the process of listening to Internet Group Management
Protocol (IGMP) network traffic. IGMP Snooping allows a network switch to listen in on the IGMP conversation between hosts and routers and maintain a map of which links need which IP multicast streams. Multicasts can be filtered from the links which do not need them in turn controlling which ports receive specific multicast traffic.
IGMP Settings
To access this page, click L2 Switching > Multicast > IGMP Snooping > IGMP Set-
tings.
Figure 4.32 L2 Switching > Multicast > IGMP Snooping > IGMP Settings
The following table describes the items in the previous figure.
Item
IGMP Snooping
State
IGMP Snooping Version
Description
Select Enable or Disable to designate the IGMP Snooping State.
Select designate the IGMP Snooping Version: V2 or V3.
50 EKI-9628G User Manual
Item
IGMP Snooping
Report Suppression
Apply
Description
Select Enable or Disable to setup the report suppression for IGMP
Snooping.
Click Apply to save the values and update the screen.
The ensuing table for IGMP Snooping Information settings are informational only and display the following: IGMP Snooping State, IGMP Snooping Version and IGMP
Snooping V2 Report Suppression.
The ensuing table for IGMP Snooping Table settings are informational only and display the following: Entry No., VLAN ID, IGMP Snooping Operation State, Router
Ports Auto Learn, Query Robustness, Query Interval (sec.), Query Max Response
Interval (sec.), Last Member Query count, Last Member Query Interval (sec), Immediate Leave and Edit (click to modify the settings).
IGMP Querier
IGMP Querier allows snooping to function by creating the tables for snooping. General queries must be unconditionally forwarded by all switches involved in IGMP snooping.
To access this page, click L2 Switching > Multicast > IGMP Snooping > IGMP
Querier.
Figure 4.33 L2 Switching > Multicast > IGMP Snooping > IGMP Querier
The following table describes the items in the previous figure.
Item
VLAN ID
Querier State
Querier Version
Description
Select the VLAN ID to define the local IGMP querier.
Select Disable or Enable to configure the VLAN ID (IGMP Querier).
Select the querier version (V2 or V3) designated to the selected VLAN
ID.
Click Apply to save the values and update the screen.
Apply
The ensuing table for IGMP Querier Status settings are informational only and display the following: VLAN ID, Querier State, Querier Status, Querier Version and Querier IP.
IGMP Static Groups
To access this page, click L2 Switching > Multicast > IGMP Snooping > IGMP
Static Groups.
Figure 4.34 L2 Switching > Multicast > IGMP Snooping > IGMP Static Groups
EKI-9628G User Manual 51
The following table describes the items in the previous figure.
Item
VLAN ID
Group IP Address
Member Ports
Add
Description
Select the VLAN ID to define IGMP static group.
Enter the IP address assigned to the VLAN ID.
Enter the port numbers to associate with the static group.
Click Add to add an IGMP group.
The ensuing table for IGMP Static Groups Status settings are informational only and display the following: VLAN ID, Group IP Address, Member Ports and Modify.
Multicast Groups
To access this page, click L2 Switching > Multicast > IGMP Snooping > Multicast
Groups.
The ensuing table for Multicast Groups settings are informational only and display the following: VLAN ID, Group IP Address, Member Ports, Type and Life (Sec).
Router Ports
To access this page, click L2 Switching > Multicast > IGMP Snooping > Router
Ports.
The ensuing table for Router Ports settings are informational only and display the following: VLAN ID, Port and Expiry Time (Sec).
4.5.8.3
MLD Snooping
The MLD Snooping page allows you to select the snooping status (enable or disable), the version (v1 or v2) and the enabling/disabling of the report suppression for the MLD querier, which sends out periodic general MLD queries and are forwarded through all ports in the VLAN.
MLD Settings
To access this page, click L2 Switching > Multicast > MLD Snooping > MLD Set-
tings.
Figure 4.35 L2 Switching > Multicast > MLD Snooping > MLD Settings
The following table describes the items in the previous figure.
Item Description
MLD Snooping State Select Enable or Disable to setup the MLD Snooping State.
MLD Snooping Version
MLD Snooping
Report Suppression
Apply
Select the querier version (V1 or V2) designated to the MLD Snooping
Version.
Select Enable or Disable to designate the status of the report suppression.
Click Apply to save the values and update the screen.
The ensuing table for MLD Snooping Information settings are informational only and display the following: MLD Snooping State, MLD Snooping Version and MLD
Snooping V2 Report Suppression.
52 EKI-9628G User Manual
The ensuing table for MLD Snooping Table settings are informational only and display the following: Entry No., VLAN ID, MLD Snooping Operation State, Router Ports
Auto Learn, Query Robustness, Query Interval (sec.), Query Max Response Interval
(sec.), Last Member Query count, Last Member Query Interval (sec), Immediate
Leave and Edit (click to modify the settings).
MLD Querier
The MLD Querier page allows you to select and enable/disable the MLD querier and define the version (IGMPv1 or IGMPv2) when enabled.
To access this page, click L2 Switching > Multicast > MLD Snooping > MLD Que-
rier.
Figure 4.36 L2 Switching > Multicast > MLD Snooping > MLD Querier
The following table describes the items in the previous figure.
Item
VLAN ID
Querier State
Querier Version
Description
Enter the VLAN ID to configure.
Select Enable or Disable status on the selected VLAN.
Enable: Enable IGMP Querier Election.
Disable: Disable IGMP Querier Election.
Select the querier version (IGMPV1 or IGMPV2) designated to the
MLD Querier function.
Click Apply to save the values and update the screen.
Apply
The ensuing table for MLD Querier Status settings are informational only and display the following: VLAN ID, Querier State, Querier Status, Querier Version and Querier IP.
MLD Static Group
The MLD Static Group page allows you to configure specified ports as static member ports.
To access this page, click L2 Switching > Multicast > MLD Snooping > MLD Static
Group.
Figure 4.37 L2 Switching > Multicast > MLD Snooping > MLD Static Group
The following table describes the items in the previous figure.
Item
VLAN ID
Description
Enter the VLAN ID to define the local MLD Static Group.
EKI-9628G User Manual 53
Item Description
Group IP Address
Member Ports
Add
Enter the IP address associated with the static group.
Enter the ports designated with the static group.
Click Add to add a MLD static group.
The ensuing table for MLD Static Groups Status settings are informational only and display the following: VLAN ID, Group IP Address, Member Ports and Modify.
Multicast Groups
To access this page, click L2 Switching > Multicast > MLD Snooping > Multicast
Groups.
The ensuing table for Multicast Groups settings are informational only and display the following: ID, Group IP Address, Member Ports, Type and Life (Sec).
Router Ports
To access this page, click L2 Switching > Multicast > MLD Snooping > Router
Ports.
The ensuing table for Router Ports settings are informational only and display the following: VLAN ID, Port and Expiry Time (Sec).
4.5.9
Jumbo Frame
Jumbo frames are frames larger than the standard Ethernet frame size of 1518 bytes. The Jumbo Frame function allows the configuration of Ethernet frame size.
To access this page, click L2 Switching > Jumbo Frame.
Figure 4.38 L2 Switching > Jumbo Frame
The following table describes the items in the previous figure.
Item
Jumbo Frame
(Bytes)
Apply
Description
Enter the variable in bytes (1518 to 9216) to define the jumbo frame size.
Click Apply to save the values and update the screen.
The ensuing table for Jumbo Frame Config settings are informational only and display the following: Jumbo Frame (Bytes).
54 EKI-9628G User Manual
4.5.10
Spanning Tree
The Spanning Tree Protocol (STP) is a network protocol to ensure loop-free topology for any bridged Ethernet local area network.
4.5.10.1
STP Global Settings
The STP Global Settings page allows you to set the STP status, select the configuration for a BPDU packet, choose the path overhead, force version and set the configuration revision range.
To access this page, click L2 Switching > Spanning Tree > STP Global Settings.
Figure 4.39 L2 Switching > Spanning Tree > STP Global Settings
The following table describes the items in the previous figure.
Item
Enabled
BPDU Forward
PathCost Method
Force Version
Description
Click the radio-button to enable or disable the STP status.
Select flooding or filtering to designate the type of BPDU packet.
Select short or long to define the method of used for path cost calculations.
Click the drop-down menu to select the operating mode for STP.
STP-Compatible: 802.1D STP operation.
RSTP-Operation: 802.1w operation.
MSTP-Operation: 802.1s operation.
Click Apply to save the values and update the screen.
Apply
The ensuing table for STP Information settings are informational only and display the following: STP, BPDU Forward, PathCost Method and Force Version.
EKI-9628G User Manual 55
4.5.10.2
STP Port Settings
The STP Port Settings page allows you to configure the ports for the setting, port’s contribution, configure edge port, and set the status of the BPDU filter.
To access this page, click L2 Switching > Spanning Tree > STP Port Settings.
Figure 4.40 L2 Switching > Spanning Tree > STP Port Settings
The following table describes the items in the previous figure.
Item Description
Port Select Select the port list to specify the ports that apply to this setting.
Admin Enable
Path Cost (0 = Auto) Set the port’s cost contribution. For a root port, the root path cost for the bridge. (0 means Auto).
Edge Port
Select Enabled or Disabled to setup the admin profile for the STP port.
Click the drop-down menu to set the edge port configuration.
No: Force to false state (as link to a bridge).
Yes: Force to true state (as link to a host).
P2P MAC Click the drop-down menu to set the Point-to-Point port configuration.
No: Force to false state.
Yes: Force to true state.
Migrate
Apply
Click the check box to enable the migrate function.
Forces the port to use the new MST/RST BPDUs, requiring the switch to test on the LAN segment. for the presence of legacy devices, which are not able to understand the new BPDU formats.
Click Apply to save the values and update the screen.
The ensuing table for STP Port Status settings are informational only and display the following: Port, Admin Enable, Path Cost, Edge Port and P2P MAC.
56 EKI-9628G User Manual
4.5.10.3
STP Bridge Settings
The STP Bridge Settings page allows you to configure the priority, forward delay, maximum age, Tx hold count, and the hello time for the bridge.
To access this page, click L2 Switching > Spanning Tree > STP Bridge Settings.
Figure 4.41 L2 Switching > Spanning Tree > STP Bridge Settings
The following table describes the items in the previous figure.
Item
Priority
Forward Delay
Max Age
Tx Hold Count
Hello Time
Description
Click the drop-down menu to select the STP bridge priority.
Enter the variable (4 to 30) to set the forward delay for STP bridge settings.
Enter the variable (6 to 40) to set the Max age for STP bridge settings.
Enter the variable (1 to 10) to designate the TX hold count for STP bridge settings.
Enter the variable (1 to 10) to designate the Hello Time for STP bridge settings.
Click Apply to save the values and update the screen.
Apply
The ensuing table for STP Bridge Information settings are informational only and display the following: Priority, Forward Delay, Max Age, Tx Hold Count and Hello
Time.
The ensuing table for STP Bridge Status settings are informational only and display the following: Bridge Identifier, Designated Root Bridge, Root Path Cost, Designated
Bridge, Root Port and Last Topology Change.
4.5.10.4
STP Port Advanced Settings
The STP Port Advanced Settings page allows you to select the port list to apply this setting.
To access this page, click L2 Switching > Spanning Tree > STP Port Advanced
Settings.
Figure 4.42 L2 Switching > Spanning Tree > STP Port Advanced Settings
EKI-9628G User Manual 57
The following table describes the items in the previous figure.
Item
Port Select
Priority
Apply
Description
Select the port to designate the STP settings.
Click the drop-down menu to designate a priority.
Click Apply to save the values and update the screen.
The ensuing table for STP Port Status settings are informational only and display the following: Port, Identifier (Priority / Port Id), Path Cost Conf/Oper, Designated Root
Bridge, Root Path Cost, Designated Bridge, Edge Port Conf/Oper, P2P MAC Conf/
Oper, Port Role and Port State.
4.5.10.5
MST Config Identification
The MST Config Identification page allows you to configure the identification setting name and the identification range.
To access this page, click L2 Switching > Spanning Tree > MST Config Identifica-
tion.
Figure 4.43 L2 Switching > Spanning Tree > MST Config Identification
The following table describes the items in the previous figure.
Item Description
Configuration Name Enter the identifier used to identify the configuration currently being used. It may be up to 32 characters.
Revision Level Enter the identifier for the Revision Configuration, range: 0 to 65535
(default: 0).
Apply Click Apply to save the values and update the screen.
The ensuing table for MST Configuration Identification Information settings are informational only and display the following: Configuration Name and Revision Level.
4.5.10.6
MST Instance ID Settings
The MST Instance ID Settings page allows you to edit the MSTI ID and VID List settings.
To access this page, click L2 Switching > Spanning Tree > MST Instance ID Set-
tings.
Figure 4.44 L2 Switching > Spanning Tree > MST Instance ID Settings
58 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item
MSTI ID
VID List
Move
Description
Enter the MST instance ID (0-15).
Enter the pre-configured VID list.
Click Move to save the values and update the screen.
The ensuing table for MST Instance ID Information settings are informational only and display the following: MSTI ID and VID List.
4.5.10.7
MST Instance Priority Settings
The MST Instance Priority Settings allows you to specify the MST instance and the bridge priority in that instance.
To access this page, click L2 Switching > Spanning Tree > MST Instance Priority
Settings.
Figure 4.45 L2 Switching > Spanning Tree > MST Instance Priority Settings
The following table describes the items in the previous figure.
Item
MSTI ID
Priority
Description
Click the drop-down menu to specify the MST instance.
Click the drop-down menu set the bridge priority in the specified MST instance
Click Apply to save the values and update the screen.
Apply
The ensuing table for MST Instance Priority Information settings are informational only and display the following: MSTI ID, Priority and Action.
4.5.10.8
MST Instance Info
To access this page, click L2 Switching > Spanning Tree > MST Instance Info.
The ensuing table for STP Bridge Status settings are informational only and display the following: Bridge Identifier, Designated Root Bridge, Root Path Cost, Designated
Bridge, Root Port and TCNLast Topology Change.
The ensuing table for STP Port Status settings are informational only and display the following: Port, Identifier (Priority / Port Id), Path Cost Conf/Oper, Designated Root
Bridge, Root Path Cost, Designated Bridge, Edge Port Conf/Oper, P2P MAC Conf/
Oper, Port Role and Port State.
4.5.10.9
STP Statistics
To access this page, click L2 Switching > Spanning Tree > STP Statistics.
The ensuing table for STP Statistics settings are informational only and display the following: Port, Configuration BPDUs Received, TCN BPDUs Received, Configuration BPDUs Transmitted and TCN BPDUs Transmitted.
EKI-9628G User Manual 59
4.5.11
X-Ring Elite
The X-Ring Elite function provides an improvement over Spanning Tree and Rapid
Spanning Tree and a rapid auto recovery in the event that the network suffers a corrupt or broken link and prevents network loops.
4.5.11.1
X-Ring Elite Settings
The X-Ring Elite Settings allows you to enable or disable the state of the X-Ring settings.
To access this page, click L2 Switching > X-Ring Elite > X-Ring Elite Settings.
Figure 4.46 L2 Switching > X-Ring Elite > X-Ring Elite Settings
The following table describes the items in the previous figure.
Item
State
Apply
Description
Select Enabled or Disabled to setup the X-Ring Elite mode.
Click Apply to save the values and update the screen.
The ensuing table for Information settings are informational only and display the following: X-Ring Elite State.
4.5.11.2
X-Ring Elite Groups
The X-Ring Elite Groups page allows you to select the function and role for each device and the connected ports.
To access this page, click L2 Switching > X-Ring Elite > X-Ring Elite Groups.
Figure 4.47 L2 Switching > X-Ring Elite > X-Ring Elite Groups
The following table describes the items in the previous figure.
Item
Ring ID
Role
Port 1
Port 2
Add
Description
Enter a number to specifies a ranging from 1 to 255 to identify a given
X-Ring Elite group.
Click the drop-down menu to select the ring role.
Click the drop-down menu to define the port designation.
Click the drop-down menu to define the port designation.
Click Add to save the values and update the screen.
The ensuing table for Information settings are informational only and display the following: Ring ID, Role, Port 1, Port 2 and Delete (click to delete the desired Ring ID).
60 EKI-9628G User Manual
4.5.12
X-Ring Pro
The X-Ring Pro function provides an improvement over Spanning Tree and Rapid
Spanning Tree and a rapid auto recovery in the event that the network suffers a corrupt or broken link and prevents network loops.
4.5.12.1
X-Ring Pro Settings
The X-Ring Pro Settings page allows you to configure the status (enabled or disabled) of the function.
To access this page, click L2 Switching > X-Ring Pro > X-Ring Pro Settings.
Figure 4.48 L2 Switching > X-Ring Pro > X-Ring Pro Settings
The following table describes the items in the previous figure.
Item
State
Apply
Description
Select Enabled or Disabled to setup the X-Ring Pro mode.
Click Apply to save the values and update the screen.
The ensuing table for Information settings are informational only and display the following: X-Ring Pro State.
4.5.12.2
X-Ring Pro Groups
The X-Ring Pro Groups page allows you to select the function and role for each ring
ID and its connected ports.
To access this page, click L2 Switching > X-Ring Pro > X-Ring Pro Groups.
Figure 4.49 L2 Switching > X-Ring Pro > X-Ring Pro Groups > X-Ring Pro
Groups Settings
The following table describes the items in the previous figure.
Item
Ring ID
Port 1
Port 2
Add
Description
Enter a number to specifies a ranging from 1 to 255 to identify a given
X-Ring Pro group.
Click the drop-down menu to define the port designation.
Click the drop-down menu to define the port designation.
Click Add to save the values and update the screen.
EKI-9628G User Manual 61
Figure 4.50 L2 Switching > X-Ring Pro > X-Ring Pro Groups > Couple Setting
The following table describes the items in the previous figure.
Item
Couple Ring ID
Port
Master Ring ID
Add
Description
Enter a number to specifies a ranging from 1 to 255 to identify a given
X-Ring group.
Enter the port to assign to define the couple setting.
Click the drop-down menu to designate the master ring.
Click Add to save the values and update the screen.
The ensuing table for Information settings are informational only and display the following: Ring ID, Mode, Operation State, Port 1, Forwarding State, Port 2, Forwarding
State and Delete (click to delete the desired Ring ID).
4.5.13
Loopback Detection
The Loopback Detection function is used to detect looped links. By sending detection frames and then checking to see if the frames returned to any port on the device, the function is used to detect loops.
4.5.13.1
Global Settings
The Global Settings page allows you to configure the state (enabled or disabled) of the function, select the interval at which frames are transmitted and the delay before recovery.
To access this page, click L2 Switching > Loopback Detection > Global Settings.
Figure 4.51 L2 Switching > Loopback Detection > Global Settings
The following table describes the items in the previous figure.
Item
State
Interval
Recover Time
Apply
Description
Select Enabled or Disabled to setup the loopback mode.
Enter the variable in seconds (1 to 32767) to set the interval at which frames are transmitted.
Enter the variable in seconds (60 to 1000000) to define the delay before recovery.
Click Apply to save the values and update the screen.
62 EKI-9628G User Manual
The ensuing table for Loopback Detection Global Information settings are informational only and display the following: State, Interval and Recover Time.
4.5.13.2
Port Settings
The Port Settings page allows you to select ports that are detected by the loopback detection function and configure their status (enabled or disabled).
To access this page, click L2 Switching > Loopback Detection > Port Settings.
Figure 4.52 L2 Switching > Loopback Detection > Port Settings
The following table describes the items in the previous figure.
Item
Port Select
Enabled
Description
Enter the port to define the local loopback detection setting.
Select Enabled or Disabled to setup the Loopback Detection function.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Loopback Detection Port Information settings are informational only and display the following: Port, Enable State and Loop Status.
EKI-9628G User Manual 63
4.6
RL3 Switching
4.6.1
SNAT (Source NAT)
Source NAT (SNAT) is the most common form of NAT. SNAT changes the source address of the packets passing through the switch. SNAT is typically used when an internal (private) host needs to initiate a session to an external (public) host.
4.6.1.1
Global Settings
To access this page, click L3 Switching > SNAT > Global Settings.
Figure 4.53 L3 Switching > SNAT > Global Settings
The following table describes the items in the previous figure.
Item
Interface
Auto Mode
Apply
Description
Click the drop-down menu to select the interface.
Select Enabled or Disabled to setup the auto mode.
Click Apply to save the values and update the screen.
The ensuing table for Global Information settings are informational only and display the following: Information Name and Information Value.
4.6.1.2
Entry Settings
To access this page, click L3 Switching > SNAT > Entry Settings.
Figure 4.54 L3 Switching > SNAT > Entry Settings
The following table describes the items in the previous figure.
Item
Interface
Original Source IP
Address
Original Source IP
Mask
Description
Click the drop-down menu to select the interface.
Define the original source IP address.
Define the original source IP mask.
64 EKI-9628G User Manual
Item
New Source IP address
Add
Description
Define the new source IP address.
Click Add to save the values and update the screen.
The ensuing table for Entry Information settings are informational only and display the following: Original Source IP Address, Original Source IP Mask, New Source IP address and Delete (click to delete the desired interface).
4.6.2
DNAT (Destination NAT)
Destination NAT (DNAT) changes the destination address of packets passing through the switch. DNAT is typically used when an external (public) host needs to initiate a session with an internal (private) host.
To access this page, click L3 Switching > DNAT.
Figure 4.55 L3 Switching > DNAT
The following table describes the items in the previous figure.
Item
Interface
Original Destination
IP Address
New Destination IP address
Apply
Description
Click the drop-down menu to select the interface.
Define the original destination IP address.
Define the new destination IP address.
Click Add to save the values and update the screen.
The ensuing table for Entry Information settings are informational only and display the following: Original Destination IP Address, New Destination IP address and
Delete (click to delete the desired interface).
EKI-9628G User Manual 65
4.6.3
Routing
To access this page, click L3 Switching > Routing.
Figure 4.56 L3 Switching > Routing
The following table describes the items in the previous figure.
Item Description
Interface
Destination IP
Address
Click the drop-down menu to select the interface.
Define the destination IP address.
Destination IP Mask Define the destination IP mask.
Gateway Define the gateway IP address.
Add Click Add to save the values and update the screen.
The ensuing table for Routing Information settings are informational only and display the following: Destination IP Address, Destination IP Mask, Gateway IP address and Delete (click to delete the desired interface).
4.7
MAC Address Table
The MAC Address Table provides access to the Static MAC Settings, MAC Aging
Time, and Dynamic Forwarding.
4.7.1
Static MAC
The Static MAC page allows you to configure the address for forwarding of packets, the VLAN ID of the listed MAC address and the designated Port.
To access this page, click MAC Address Table > Static MAC.
Figure 4.57 MAC Address Table > Static MAC
66 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item
MAC Address
VLAN
Port
Apply
Description
Enter the MAC address to which packets are statically forwarded.
Click the drop-down menu to select the VLAN ID number of the VLAN for which the MAC address is residing.
Click the drop-down menu to select the port number.
Click Apply to save the values and update the screen.
The ensuing table for Static MAC Status settings are informational only and display the following: No., MAC Address, VLAN, Port and Delete (click to delete the desired
MAC address).
4.7.2
MAC Aging Time
The MAC Aging Time page allows you to set the MAC address of the aging time to study.
To access this page, click MAC Address Table > MAC Aging Time.
Figure 4.58 MAC Address Table > MAC Aging Time
The following table describes the items in the previous figure.
Item
Aging Time
Apply
Description
Enter the variable (10 to 630) to define the time required for aging.
Click Apply to save the values and update the screen.
The ensuing table for Dynamic Address Status settings are informational only and display the following: Aging time.
4.7.3
Dynamic Forwarding Table
The Dynamic Forwarding function allows you to configure an address tables, which contain the following:
The port each hardware address is associated with
The VLAN to show or clear dynamic MAC entries
The MAC address selection
To access this page, click MAC Address Table > Dynamic Forwarding Table.
Figure 4.59 MAC Address Table > Dynamic Forwarding Table
EKI-9628G User Manual 67
The following table describes the items in the previous figure.
Item
Port
VLAN
MAC Address
View
Clear
Description
Click the drop-down menu to select the port number to show or clear dynamic MAC entries. If a port, VLAN or MAC address is not selected the whole dynamic MAC table is displayed or cleared.
Click the drop-down menu to select the VLAN to show or clear dynamic MAC entries.
Enter the MAC address to show or clear dynamic MAC entries. If a port, VLAN or MAC address is not selected the whole dynamic MAC table is displayed or cleared.
Click View to display the MAC address information.
Click Clear to clear the MAC Address Information table.
The ensuing table for MAC Address Information settings are informational only and display the following: MAC Address, VLAN, Type, Port and Add to Static MAC (click to add the MAC address to static MAC address list).
4.8
Security
The Security function allows for the configuration of Storm Control, Port Security, Protected Ports, DoS Prevention, Applications, 802.1x, and IP Security.
4.8.1
Storm Control
The Storm Control page allows you to setup the units and Preamble/IFG to manage the occurrence of packet flooding on the LAN and consequent traffic to prevent the degrading of network performance.
4.8.1.1
Global Settings
To access this page, click Security > Storm Control > Global Settings.
Figure 4.60 Security > Storm Control > Global Settings
The following table describes the items in the previous figure.
Item
Unit
Preamble & IFG
Description
Select pps or bps control units for the Storm Control function.
Select Excluded or Included to setup the Storm Control Global settings.
Excluded: exclude preamble & IFG (20 bytes) when count ingress storm control rate.
Included: include preamble & IFG (20 bytes) when count ingress storm control rate.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Storm Control Global Information settings are informational only and display the following: Unit and Preamble & IFG.
68 EKI-9628G User Manual
4.8.1.2
Port Settings
The Port Settings page allows you to configure the port and the type of storm control association along with the value of the storm rate for the selected port.
To access this page, click Security > Storm Control > Port Settings.
Figure 4.61 Security > Storm Control > Port Settings
The following table describes the items in the previous figure.
Item
Port
Port State
Action
Type Enable
Description
Enter the port number to designate the local port for the Storm Control function.
Select Disabled or Enabled to define the port state
Click the drop-down menu to select the type of action to designate for the selected port during a Storm Control incident. The options are
Drop and Shutdown.
Click the radio button to enable Broadcast, Unknown Multicast, or
Unknown Unicast.
Broadcast: Select the variable in Kbps to define the broadcast bandwidth.
Unknown Multicast: Select the variable in Kbps to define the multicast setting.
Broadcast: Select the variable in Kbps to define the unknown unicast setting.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Storm Control Port Information settings are informational only and display the following: Port, Port State, Broadcast (Kbps), Unknown Multicast
(Kbps), Unknown Unicast (Kbps) and Action.
EKI-9628G User Manual 69
4.8.2
Port Security
The Port Security page allows you to configure port isolation behavior.
To access this page, click Security > Port Security.
Figure 4.62 Security > Port Security
The following table describes the items in the previous figure.
Item Description
Port Select
Enabled
FDB Learn Limit
(0-64)
Violation MAC Notification
Apply
Enter a single or multiple port numbers to configure.
Select Enabled or Disabled to define the selected Port.
Enter the variable (0 to 64) to set the learn limit for the FDB setting.
Select Enabled or Disabled to define the selected Port.
Click Apply to save the values and update the screen.
The ensuing table for Port Security Information settings are informational only and display the following: Port, Enabled, FDB Learn Limit and Violation MAC Notification.
4.8.3
Protected Ports
The Protected Port page allows you to configure a single or multiple ports as a protected or unprotected type.
To access this page, click Security > Protected Ports.
Figure 4.63 Security > Protected Ports
The following table describes the items in the previous figure.
Item
Port List
Port Type
Apply
Description
Enter the port number to designate for the Protected Port setting.
Select Unprotected or Protected to define the port type.
Click Apply to save the values and update the screen.
The ensuing table for Protected Ports Status settings are informational only and display the following: Protected Ports and Unprotected Ports.
70 EKI-9628G User Manual
4.8.4
DoS Prevention
The DoS Prevention page allows you to setup (enabled or disabled) the denial of service.
4.8.4.1
DoS Global Settings
The DoS Global Settings page allows you to configure (enabled or disabled) the setting for each function.
To access this page, click Security > DoS Prevention > DoS Global Settings.
Figure 4.64 Security > DoS Prevention > DoS Global Settings
The following table describes the items in the previous figure.
Item
DMAC = SMAC
LAND
Description
Click Enabled or Disabled to define DMAC-SMAC for the DoS Global settings.
Click Enabled or Disabled to define LAND for the DoS Global settings.
EKI-9628G User Manual 71
Item Description
UDP Blat
TCP Blat
Click Enabled or Disabled to define UDP Blat for the DoS Global settings.
Click Enabled or Disabled to define TCP Blat for the DoS Global settings.
POD Click Enabled or Disabled to define POD for the DoS Global settings.
IPv6 Min Fragment Click Enabled or Disabled to define minimum fragment size for the
IPv6 protocol.
Enter the variable in bytes (0 to 65535) to set the minimum fragment size when the function is enabled.
ICMP Fragments Click Enabled or Disabled to define the ICMP Fragments function.
IPv4 Ping Max Size Click Enabled or Disabled to set the maximum ping size for the IPv4 protocol.
IPv6 Ping Max Size Click Enabled or Disabled to set a maximum ping size for the IPv6 protocol.
Ping Max Size Setting
Enter the variable in bytes (0 to 65535) to set the maximum ping size.
Smurf Attack
TCP Min Hdr Size
Click Enabled or Disabled to set the Smurf Attack function.
Click Enabled or Disabled to set the minimum header size.
Enter the variable in bytes (0 to 31) to set the minimum header size.
TCP-SYN (SPORT <
1024)
Click Enabled or Disabled to set the TCP synchronization function
(sport < 1021).
Null Scan Attack Click Enabled or Disabled to set the Null Scan Attack function.
X-Mas Scan Attack Click Enabled or Disabled to set the X-Mas Scan function.
TCP SYN-FIN Attack Click Enabled or Disabled to set the TCP synchronization termination attack function.
TCP SYN-RST
Attack
TCP Fragment (Offset = 1)
Apply
Click Enabled or Disabled to set the TCP synchronization reset attack function.
Click Enabled or Disabled to set the TCP fragment function (offset
=1).
Click Apply to save the values and update the screen.
The ensuing table for DoS Global Information settings are informational only and display the following: DMAC = SMAC, Land Attack, UDP Blat, TCP Blat, POD (Ping of Death), IPv6 Min Fragment Size, ICMP Fragment Packets, IPv4 Ping Max Packet
Size, IPv6 Ping Max Packet Size, Smurf Attack, TCP Min Header Length, TCP Syn
(SPORT < 1024), Null Scan Attack, X-Mas Scan Attack, TCP SYN-FIN Attack, TCP
SYN-RST Attack and TCP Fragment (Offset = 1).
4.8.4.2
DoS Port Settings
The DoS Port Settings page allow you to configure DoS security (enabled or disabled) for the selected port.
To access this page, click Security > DoS Prevention > DoS Port Settings.
Figure 4.65 Security > DoS Prevention > DoS Port Settings
72 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item
Port
DoS Protection
Apply
Description
Select the port to configure for the DoS prevention function.
Click Enabled or Disabled to set the DoS Port security function state.
Click Apply to save the values and update the screen.
The ensuing table for DoS Port Status settings are informational only and display the following: Port and DoS Protection.
4.8.5
Applications
The Applications function allows you to configure various types of AAA lists.
4.8.5.1
TELNET
The TELNET page allows you to combine all kinds of AAA lists with the Telnet line.
To access this page, click Security > Applications > TELNET.
Figure 4.66 Security > Applications > TELNET
The following table describes the items in the previous figure.
Item
Telnet Service
Apply
Disconnect
Description
Click Enabled or Disabled to set remote access through the Telnet
Service function.
Click Apply to save the values and update the screen.
Click Disconnect to disable the current Telnet service.
The ensuing table for Telnet Information settings are informational only and display the following: Telnet Service and Current Telnet Sessions Count.
4.8.5.2
SSH
Secure Shell (SSH) is a protocol providing secure (encrypted) management connection to a remote device.
To access this page, click Security > Applications > SSH.
Figure 4.67 Security > Applications > SSH
The following table describes the items in the previous figure.
Item
SSH Service
Apply
Description
Click Enabled or Disabled to set up Ethernet encapsulation (remote access) through the Secure Shell (SSH) function.
Click Apply to save the values and update the screen.
EKI-9628G User Manual 73
The ensuing table for SSH Information settings are informational only and display the following: SSH.
4.8.5.3
HTTP
The HTTP page allows you to combine all kinds of AAA lists to the HTTP line.
Attempts to access the switch’s Web UI from HTTP are first authenticated.
To access this page, click Security > Applications > HTTP.
Figure 4.68 Security > Applications > HTTP
The following table describes the items in the previous figure.
Item
HTTP Service
Session Timeout
Description
Click Enabled or Disabled to set up Ethernet encapsulation (remote access) through HTTP function.
Enter the variable in minutes (0 to 86400) to define the timeout period for the HTTP session.
Click Apply to save the values and update the screen.
Apply
The ensuing table for HTTP Information settings are informational only and display the following: HTTP Service and Session Timeout.
4.8.5.4
HTTPS
The HTTPS page allows you to combine all kinds of AAA lists on the HTTPS line.
Attempts to access the switch’s Web UI from HTTPS are first authenticated.
To access this page, click Security > Applications > HTTPS.
Figure 4.69 Security > Applications > HTTPS
The following table describes the items in the previous figure.
Item
HTTPS Service
Session Timeout
Description
Click Enabled or Disabled to set up Ethernet encapsulation over
HTTPS.
Enter the variable in minutes (0 to 86400) to define the timeout period for the HTTP session.
Click Apply to save the values and update the screen.
Apply
The ensuing table for HTTPS Information settings are informational only and display the following: HTTPS Service and Session Timeout.
74 EKI-9628G User Manual
4.8.6
802.1x
The 802.1x function provides port-based authentication to prevent unauthorized devices (clients) from gaining access to the network.
4.8.6.1
802.1x Settings
The 802.1x Settings page allows you to set the state (enabled or disabled) for the selected IP server address, port, accounting port and associated password, including a reauthentication period.
To access this page, click Security > 802.1x > 802.1x Settings.
Figure 4.70 Security > 802.1x > 802.1x Settings
The following table describes the items in the previous figure.
Item
State
Server IP
Server Port
Accounting Port
Security Key
Reauth Period
Description
Click Enabled or Disabled to set up 802.1x Setting function.
Enter the IP address of the local server providing authentication function.
Enter the port number (1 to 65535) assigned to the listed Server IP.
Enter the port number (1 to 65535) assigned to the listed server IP configured to provide authorization and authentication for network access.
Enter the variable to define the network security key used in authentication.
Enter the variable in seconds to define the period of time between authentication attempts.
Click Apply to save the values and update the screen.
Apply
The ensuing table for 802.1x Information settings are informational only and display the following: 802.1x State, Server IP, Server Port, Accounting Port, Security Key and
Reauth Period.
EKI-9628G User Manual 75
4.8.6.2
802.1x Port Configuration
The 802.1x Port Configuration page allows you to identify the authorization state for a port by using a MAC or Port authentication base.
To access this page, click Security > 802.1x > 802.1x Port Configuration.
Figure 4.71 Security > 802.1x > 802.1x Port Configuration
The following table describes the items in the previous figure.
Item Description
Authentication based Click Port or Mac to designate the type of configuration for the 802.1x
Port setting.
Port Select Enter the port number associated with the configuration setting.
State
Apply
Click Authorize or Disabled to define the listed port’s state mode.
Click Apply to save the values and update the screen.
The ensuing table for 802.1x Port Authorization settings are informational only and display the following: Port and Port State.
4.8.7
IP Security
This section provides you a means to configure the IP Security settings.
4.8.7.1
Global Settings
The Global Settings page allows you to set the IP Security status (enabled or disabled).
To access this page, click Security > IP Security > Global Settings.
Figure 4.72 Security > IP Security > Global Settings
The following table describes the items in the previous figure.
Item
Status
Description
Click Enabled or Disabled to define the global setting for the IP security function.
Click Apply to save the values and update the screen.
Apply
The ensuing table for IP Security Status settings are informational only and display the following: IP Security.
76 EKI-9628G User Manual
4.8.7.2
Entry Settings
Once the Global Setting is enabled, use the Entry Settings to define an IP Security entry.
To access this page, click Security > IP Security > Entry Settings.
Figure 4.73 Security > IP Security > Entry Settings
The following table describes the items in the previous figure.
Item
Interface
VLAN ID
IP Address
IP Mask
Services
Apply
Description
Click the drop-down menu to select the interface.
Enter the source IP address to apply the IP Security function.
Enter the IP address for use in masking the previous IP Address.
Enter the type of services to associate with the entry setting.
Click Apply to save the values and update the screen.
The ensuing table for IP Security Information settings are informational only and display the following: VLAN ID, IP Address, IP Mask, Services and Action.
4.9
QoS
The QoS function allows you to configure settings for the switch QoS interface and how the switch connects to a remote server to get services.
4.9.1
General
Traditionally, networks operate on a best-effort delivery basis, all traffic has equal priority and an equal chance of being delivered in a timely manner. When there is congestion, all traffic has an equal chance of being dropped.
The QoS feature can be configured for congestion-management and congestionavoidance to specifically manage the priority of the traffic delivery. Implementing QoS in the network makes performance predictable and bandwidth utilization much more effective.
The QoS implementation is based on the prioritization values in Layer 2 frames.
EKI-9628G User Manual 77
4.9.1.1
QoS Properties
The QoS Properties allows you to set the QoS mode.
To access this page, click QoS > General > QoS Properties.
Figure 4.74 QoS > General > QoS Properties
The following table describes the items in the previous figure.
Item
QoS Mode
Apply
Description
Select Disabled or Basic to setup the QoS function.
Click Apply to save the values and update the screen.
The ensuing table for QoS Global Information settings are informational only and display the following: QoS Mode.
4.9.1.2
QoS Settings
Once the QoS function is enabled, you can configure the available settings.
To access this page, click QoS > General > QoS Settings.
Figure 4.75 QoS > General > QoS Settings
The following table describes the items in the previous figure.
Item
Port
CoS Value
Remark CoS
Remark DSCP
Remark IP Precedence
Apply
Description
Enter the port number to associate with the QoS setting.
Click the drop-down menu to designate the Class of Service (CoS) value (0 to 7) for the Port entry.
Click Disabled or Enabled to setup the Remark CoS function. When enabled the LAN (preassigned priority values) is marked at Layer 2 boundary to CoS values.
Click Disabled or Enabled to setup the DSCP remark option for the
QoS function.
Click Disabled or Enabled to setup the Remark IP Precedence for the QoS function.
Click Apply to save the values and update the screen.
The ensuing table for QoS Status settings are informational only and display the following: Port, CoS value, Remark CoS, Remark DSCP and Remark IP Precedence.
78 EKI-9628G User Manual
4.9.1.3
Queue Scheduling
The switch support eight CoS queues for each egress port. For each of the eight queues, two types of scheduling can be configured: Strict Priority and Weighted
Round Robin (WRR).
Strict Priority scheduling is based on the priority of queues. Packets in a high-priority queue are always sent first and packets in a low-priority queue are only sent after all the high priority queues are empty.
Weighted RoundRobin (WRR) scheduling is based on the user priority specification to indicate the importance (weight) of the queue relative to the other CoS queues.
WRR scheduling prevents low-priority queues from being completely ignored during periods of high priority traffic. The WRR scheduler sends some packets from each queue in turn.
To access this page, click QoS > General > QoS Scheduling.
Figure 4.76 QoS > General > QoS Scheduling
The following table describes the items in the previous figure.
Item Description
Queue
Strict
WRR
Weight
Queue entry for egress port.
Select Strict to assign the scheduling designation to the selected queue.
Select WRR to assign the scheduling designation to the selected queue.
Enter a queue priority (weight) relative to the defined entries (WRR only).
% of WRR Bandwidth Displays the allotted bandwidth for the queue entry in percentage values.
Apply Click Apply to save the values and update the screen.
The ensuing table for Queue Information settings are informational only and display the following: Strict Priority Queue Number.
EKI-9628G User Manual 79
4.9.1.4
CoS Mapping
The CoS Mapping allows you to apply CoS mapping.
To access this page, click QoS > General > CoS Mapping.
Figure 4.77 QoS > General > CoS Mapping
The following table describes the items in the previous figure.
Item Description
CoS to Queue Mapping
Class of Service Displays the CoS for the queue entry.
Queue Click the drop-down menu to select the queue priority for selected
CoS
Queue to CoS Mapping
Queue
Class of Service
Apply
Displays the queue entry for CoS mapping.
Click the drop-down menu to select the CoS type
Click Apply to save the values and update the screen.
The ensuing table for CoS Mapping Information settings are informational only and display the following: CoS and Mapping to Queue.
The ensuing table for Queue Mapping Information settings are informational only and display the following: Queue and Mapping to CoS.
80 EKI-9628G User Manual
4.9.1.5
DSCP Mapping
The DSCP to Queue mapping function maps queue values in incoming packets to a
DSCP value that QoS uses internally to represent the priority of the traffic. The following table shows the DSCP to Queue map.
If these values are not appropriate for your network, you need to modify them.
To access this page, click QoS > General > DSCP Mapping.
Figure 4.78 QoS > General > DSCP Mapping
The following table describes the items in the previous figure.
Item Description
DSCP to Queue Mapping
DSCP
Queue
Enter the DSCP entry to define the precedence values.
Click the drop-down menu to select the queue designation for the
DSCP value.
Queue to DSCP Mapping
Queue Displays the queue value for the DSCP map.
DSCP
Apply
Enter the DSCP entry to define the precedence values.
Click Apply to save the values and update the screen.
The ensuing table for DSCP Mapping Information settings are informational only and display the following: DSCP and Mapping to Queue.
The ensuing table for Queue Mapping Information settings are informational only and display the following: Queue and Mapping to DSCP.
EKI-9628G User Manual 81
4.9.1.6
IP Precedence Mapping
The IP Precedence Mapping allows you to set IP Precedence mapping.
To access this page, click QoS > General > IP Precedence Mapping.
Figure 4.79 QoS > General > IP Precedence Mapping
The following table describes the items in the previous figure.
Item Description
IP Precedence to Queue Mapping
IP Precedence Displays the IP precedence value for the queue map.
Queue Click the drop-down menu to map a queue value to the selected IP precedence.
Queue to IP Precedence Mapping
Queue
IP Precedence
Displays the queue entry for mapping IP precedence values.
Click the drop-down menu to map an IP precedence value to the selected queue.
Apply Click Apply to save the values and update the screen.
The ensuing table for IP Precedence Mapping Information settings are informational only and display the following: IP Precedence and Mapping to Queue.
The ensuing table for Queue Mapping Information settings are informational only and display the following: Queue and Mapping to IP Precedence.
82 EKI-9628G User Manual
4.9.2
QoS Basic Mode
Quality of Service (QoS) allows to give preferential treatment to certain types of traffic at the expense of others. Without QoS, the switch offers best-effort service to each packet, regardless of the packet contents or size sending the packets without any assurance of reliability, delay bounds, or throughput.
QoS mode supports two modes: 802.1p and DSCP.
4.9.2.1
Global Settings
The Global Settings page allows you to configure the trust mode to a port selection.
To access this page, click QoS > QoS Basic Mode > Global Settings.
The function is only available when QoS Properties is set to Basic.
Figure 4.80 QoS > QoS Basic Mode > Global Settings
The following table describes the items in the previous figure.
Item
Trust Mode
Description
Click the drop-down menu to select the trust state of the QoS basic mode.
Click Apply to save the values and update the screen.
Apply
The ensuing table for QoS Information settings are informational only and display the following: Trust Mode.
4.9.2.2
Port Settings
The Port Settings page allows you to define a trust state (enabled or disabled) to a listed port.
To access this page, click QoS > QoS Basic Mode > Port Settings.
Figure 4.81 QoS > QoS Basic Mode > Port Settings
The following table describes the items in the previous figure.
Item
Port
Trust State
Apply
Description
Enter the port number for the QoS basic mode setting.
Select Enabled or Disabled to set the port’s trust state status.
Click Apply to save the values and update the screen.
The ensuing table for QoS Port Status settings are informational only and display the following: Port and Trust State.
EKI-9628G User Manual 83
4.9.3
Rate Limit
Rate Limits features control on a per port basis. Bandwidth control is supported for the following: Ingress Bandwidth Control, Egress Bandwidth Control and Egress
Queue.
4.9.3.1
Ingress Bandwidth Control
The Ingress Bandwidth Control page allows you to configure the bandwidth control for a listed port.
To access this page, click QoS > Rate Limit > Ingress Bandwidth Control.
Figure 4.82 QoS > Rate Limit > Ingress Bandwidth Control
The following table describes the items in the previous figure.
Item
Port
State
Rate (Kbps)
Description
Enter the port number for the rate limit setup.
Select Disabled or Enabled to set the port’s state status.
Enter the value in Kbps (16 to 1000000) to set as the bandwidth rate for the selected port.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Ingress Bandwidth Control Status settings are informational only and display the following: Port and Ingress Rate Limit (Kbps).
4.9.3.2
Egress Bandwidth Control
The Egress Bandwidth Control page allows you to set the egress bandwidth control for a listed port.
To access this page, click QoS > Rate Limit > Egress Bandwidth Control.
Figure 4.83 QoS > Rate Limit > Egress Bandwidth Control
The following table describes the items in the previous figure.
Item
Port
Description
Enter the port number to set the Egress Bandwidth Control.
84 EKI-9628G User Manual
Item Description
State
Rate (Kbps)
Select Disabled or Enabled to set the Egress Bandwidth Control state.
Enter the value in Kbps (16 to 1000000) to set the Egress Bandwidth rate.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Egress Bandwidth Control Status settings are informational only and display the following: Port and Egress Rate Limit (Kbps).
4.9.3.3
Egress Queue
The Egress Queue page allows you to set the egress bandwidth parameters.
To access this page, click QoS > Rate Limit > Egress Queue.
Figure 4.84 QoS > Rate Limit > Egress Queue
The following table describes the items in the previous figure.
Item
Port
Queue
State
CIR (Kbps)
Description
Click the drop-down menu to select the port to define the Egress queue.
Click the drop-down menu to set the queue order for the Egress setting.
Click Disabled or Enabled to set the Egress queue state.
Enter the value in Kbps (16 to 1000000) to set the CIR rate for the
Egress queue.
Click Apply to save the values and update the screen.
Apply
The ensuing table for FE1 Egress Per Queue Status settings are informational only and display the following: Queue Id and Egress Rate Limit (Kbps).
EKI-9628G User Manual 85
4.10
Management
4.10.1
LLDP
LLDP is a one-way protocol without request/response sequences. Information is advertised by stations implementing the transmit function, and is received and processed by stations implementing the receive function.
4.10.1.1
LLDP System Settings
The LLDP System Settings allows you to configure the status (enabled or disabled) for the protocol, set the interval for frame transmission, set the hold time multiplier and the re-initialization delay.
To access this page, click Management > LLDP > LLDP System Settings.
Figure 4.85 Management > LLDP > LLDP System Settings
The following table describes the items in the previous figure.
Item Description
Enabled Click Enabled or Disabled to set the Global Settings state.
LLDP PDU Disable
Action
Click to select the LLDP PDU handling action when LLDP is globally disabled. Options include: Filtered, Bridged, or Flooded.
Transmission Interval Select the interval at which frames are transmitted. The default is 30 seconds, and the valid range is 5 to 32768 seconds.
Holdtime Multiplier Select the multiplier on the transmit interval to assign to TTL.
Reinitialization Delay Select the delay length before re-initialization.
Transmit Delay
Apply
Select the delay after an LLDP frame is sent.
Click Apply to save the values and update the screen.
The ensuing table for LLDP Global Config settings are informational only and display the following: LLDP Enabled, LLDP PDU Disable Action, Transmission Interval,
Holdtime Multiplier, Reinitialization Delay and Transmit Delay.
86 EKI-9628G User Manual
4.10.1.2
LLDP Port Settings
The LLDP Port Settings page allows you to configure the state (enabled or disabled) of the selected port.
To access this page, click Management > LLDP > LLDP Port Settings.
Figure 4.86 Management > LLDP > LLDP Port Settings > LLDP Port
Configuration
The following table describes the items in the previous figure.
Item
Port Select
State
Apply
Description
Enter the port number associated with the LLDP setting.
Click the drop-down menu to select the LLDP port state.
Click Apply to save the values and update the screen.
Figure 4.87 Management > LLDP > LLDP Port Settings > Optional TLVs
Selection
The following table describes the items in the previous figure.
Item Description
Port Select Enter the port number associated with the TLV (optional) selection.
Optional TLV Select Click the drop-down menu to select the LLDP optional TLVs to be carried (multiple selections are allowed).
System Name: To include system name TLV in LLDP frames.
Port Description: To include port description TLV in LLDP frames.
System Description: To include system description TLV in LLDP frames.
System Capability: To include system capability TLV in LLDP frames.
802.3 MAC-PHY:
802.3 Link Aggregation:
802.3 Maximum Frame Size:
Management Address:
802.1 PVID:
Apply Click Apply to save the values and update the screen.
EKI-9628G User Manual 87
The ensuing table for LLDP Port Status settings are informational only and display the following: Port, State and Selected Optional TLVs.
Figure 4.88 Management > LLDP > LLDP Port Settings > VLAN Name TLV VLAN
Selection
The following table describes the items in the previous figure.
Item
Port Select
VLAN Select
Description
Enter the port number to associated with the TLV selection.
Select the VLAN Name ID to be carried out (multiple selection is allowed).
Click Apply to save the values and update the screen.
Apply
The ensuing table for LLDP Port VLAN TLV Status settings are informational only and display the following: Port and Selected VLAN.
4.10.1.3
LLDP Local Device Info
The LLDP Local Device Info page allows you to view information regarding network devices, providing that the switch has already obtained LLDP information on the devices.
To access this page, click Management > LLDP > LLDP Local Device Info.
The ensuing table for Local Device Summary settings are informational only and display the following: Chassis ID Subtype, Chassis ID, System Name, System
Description, Capabilities Supported, Capabilities Enabled and Port ID Subtype.
The ensuing table for Port Status settings are informational only and display the following: Port, Selected VLAN and Detail (click the radio box and click Detail to displays the details).
4.10.1.4
LLDP Remote Device Info
The LLDP Remote Device Info page allows you to view information about remote devices, LLDP information must be available on the switch.
To access this page, click Management > LLDP > LLDP Remote Device Info.
Figure 4.89 Management > LLDP > LLDP Remote Device Info
The following table describes the items in the previous figure.
Item
Detail
Delete
Refresh
Description
Click to display the device details.
Click to delete the selected devices.
Click to refresh the remote device information list.
88 EKI-9628G User Manual
4.10.1.5
LLDP Overloading
To access this page, click Management > LLDP > LLDP Overloading.
The ensuing table for LLDP Overloading settings are informational only and display the following: Port, Total (Bytes), Left to Send (Bytes), Status and Status (Mandatory
TLVs, 802.3 TLVs, Optional TLVs and 802.1 TLVs).
4.10.2
SNMP
Simple Network Management Protocol (SNMP) is a protocol to facilitate the monitoring and exchange of management information between network devices. Through
SNMP, the health of the network or status of a particular device can be determined.
4.10.2.1
SNMP Settings
The SNMP Settings page allows you to set the SNMP daemon state (enabled or disabled).
To access this page, click Management > SNMP > SNMP Settings.
Figure 4.90 Management > SNMP > SNMP Settings
The following table describes the items in the previous figure.
Item
State
Apply
Description
Click Enabled or Disabled to define the SNMP daemon.
Click Apply to save the values and update the screen.
The ensuing table for SNMP Information settings are informational only and display the following: SNMP.
4.10.2.2
SNMP Community
The SNMP Community page provides configuration options for the community.
SNMP v1 and SNMP v2c use the group name (Community Name) certification. It’s role is similar to the password function. If SNMP v1 and SNMP v2c are used, you can go directly from the configuration settings to this page to configure the SNMP community.
To access this page, click Management > SNMP > SNMP Community.
Figure 4.91 Management > SNMP > SNMP Community
The following table describes the items in the previous figure.
Item
Community Name
Description
Enter a community name (up to 20 characters).
EKI-9628G User Manual 89
Item
Access Right
Apply
Description
Click the radio box to specify the access level (read only or read write)
Click Apply to save the values and update the screen.
The ensuing table for Community Status settings are informational only and display the following: No., Community Name, Access Right and Delete (click to delete the desired community name).
4.10.2.3
SNMP User Settings
The SNMP User Settings page allows you to create SNMP groups. The users have the same level of security and access control permissions as defined by the group settings.
To access this page, click Management > SNMP > SNMP User Settings.
Figure 4.92 Management > SNMP > SNMP User Settings
The following table describes the items in the previous figure.
Item
User Name
Access Right
Encrypted
Auth-Protocol
Password
Priv-Protocol
Password
Description
Enter a user name (up to 32 characters) to create an SNMP profile.
Click read-only or read-write to define the access right for the profile.
Click the option to set the encrypted option for the user setting.
Click the drop-down menu to select the authentication level: MD5 or
SHA. The field requires a user password.
MD5: specify HMAC-MD5-96 authentication level
SHA: specify HMAC-SHA authentication protocol
Enter the characters to define the password associated with the authentication protocol.
Click the drop-down menu to select an authorization protocol: none or
DES.The field requires a user password.
None: no authorization protocol in use
DES: specify 56-bit encryption in use
Enter the characters to define the password associated with the authorization protocol.
Click Add to save the values and update the screen.
Add
The ensuing table for User Status settings are informational only and display the following: User Name, Access Right, Auth-Protocol, Priv-Protocol and Delete (click to delete the desired user name).
90 EKI-9628G User Manual
4.10.2.4
SNMP Trap
The SNMP Trap page allows you to set the IP address of the node and the SNMP credentials corresponding to the version that is included in the trap message.
To access this page, click Management > SNMP > SNMP Trap.
Figure 4.93 Management > SNMP > SNMP Trap
The following table describes the items in the previous figure.
Item
IP Address
Community Name
Version
Description
Enter the IP address to designate the SNMP trap host.
Click the drop-down menu to select a defined community name.
Click the drop-down menu to designate the SNMP version credentials
(v1 or v2c).
Click Add to save the values and update the screen.
Add
The ensuing table for Trap Host Status settings are informational only and display the following: No., IP Address, Community Name, Version and Delete (click to delete the desired IP address).
4.10.3
TCP Modbus Settings
The TCP Modbus function allows for client-server communication between a switch module (server) and a device in the networking running MODBUS client software (client).
4.10.3.1
TCP Modbus Settings
The TCP Modbus Settings page allows you to configure the modbus function.
To access this page, click Management > TCP Modbus Settings > TCP Modbus
Settings.
Figure 4.94 Management > TCP Modbus Settings > TCP Modbus Settings
The following table describes the items in the previous figure.
Item
State
Description
Click Disabled or Enabled to set the TCP Modbus state.
EKI-9628G User Manual 91
Item
Time out
Description
Enter the value (1 to 86400) to define the timeout period between transport time.
Click Apply to save the values and update the screen.
Apply
The ensuing table for TCP Modbus Status settings are informational only and display the following: TCP Modbus status and TCP Modbus time out.
4.10.4
DHCP Server
The Dynamic Host Configuration Protocol (DHCP) is a network protocol enabling a server to automatically assign an IP address to a computer from a defined range of numbers configured for a given network.
4.10.4.1
Status Settings
The Status Settings page allows you to configure the DHCP server mode (enabled or disabled).
To access this page, click Management > DHCP Server > Status Settings.
Figure 4.95 Management > DHCP Server > Status Settings
The following table describes the items in the previous figure.
Item
DHCP Server
Apply
Restart
Description
Select Enable or Disable to designate the DHCP server function type.
When a new DHCP server mode is selected, the switch requires a system restart for the new mode to take effect.
Click Apply to save the values and update the screen.
Click Restart to have the switch perform a system restart function. In the event that the IP settings are changed, the DHCP server must be restarted for the IP settings to take effect.
The ensuing table for Status Information settings are informational only and display the following: DHCP Server Service.
92 EKI-9628G User Manual
4.10.4.2
Global Settings
The Global Settings page allows you to configure the global settings for the DHCP function.
To access this page, click Management > DHCP Server > Global Settings.
Figure 4.96 Management > DHCP Server > Global Settings
The following table describes the items in the previous figure.
Item
Lease Time
Low IP Address
High IP Address
Subnet Mask
Gateway
DNS
Apply
Description
Type in the value designating the lease time (60 - 864000) in seconds for each setting lease.
Type in the value designating the lowest range in the IP address pool.
Type in the value designating the highest range in the IP address pool.
Type in the value designating the subnet mask for the IP address pool.
Type in the value designating the gateway for the IP address pool.
Type in the value designating the DNS for the IP address pool.
Click Apply to save the values and update the screen.
The ensuing table for Global Information settings are informational only and display the following: Lease Time, Low IP Address, High IP Address, Subnet Mask, Gateway,
DNS and Clear (click to clear IP pool).
EKI-9628G User Manual 93
4.10.4.3
Port Settings
The Port Settings page allows you to configure selected ports for the DHCP function.
To access this page, click Management > DHCP Server > Port Settings.
Figure 4.97 Management > DHCP Server > Port Settings
The following table describes the items in the previous figure.
Item
Port Select
Low IP Address
High IP Address
Subnet Mask
Gateway
DNS
Apply
Description
Click the drop-down menu to select a pre-defined port to configure.
The suboptions are designated for the selected port.
Type in the value designating the lowest range in the IP address pool.
Type in the value designating the highest range in the IP address pool.
Type in the value designating the subnet mask for the IP address pool.
Type in the value designating the gateway for the IP address pool.
Type in the value designating the DNS for the IP address pool.
Click Apply to save the values and update the screen.
The ensuing table for Port Information settings are informational only and display the following: Port, Low IP Address, High IP Address, Subnet Mask, Gateway, DNS,
Edit (click to modify the settings) and Clear (click to clear the settings).
94 EKI-9628G User Manual
4.10.4.4
VLAN Settings
To access this page, click Management > DHCP Server > VLAN Settings.
Figure 4.98 Management > DHCP Server > VLAN Settings
The following table describes the items in the previous figure.
Item
Entry
VLAN ID
Low IP Address
High IP Address
Subnet Mask
Gateway
DNS
Apply
Description
Click the drop-down menu to select an entry for the VLAN setting.
Type in the value designating the VLAN ID.
Type in the value designating the lowest range in the IP address pool.
Type in the value designating the highest range in the IP address pool.
Type in the value designating the subnet mask for the IP address pool.
Type in the value designating the gateway for the IP address pool.
Type in the value designating the DNS for the IP address pool.
Click Apply to save the values and update the screen.
The ensuing table for Entry Information settings are informational only and display the following: Entry (click the drop-down menu to select an entry), Entry ID, VLAN ID,
Low IP Address, High IP Address, Subnet Mask, Gateway, DNS, Edit (click to modify the settings) and Clear (click to clear the settings).
EKI-9628G User Manual 95
4.10.4.5
Option 82 Settings
The Option 82 Settings, also known as the DHCP relay agent information option, provide information about the network location of a DHCP client. In turn, the DHCP server uses the information to implement IP addresses or other parameters for the client.
To access this page, click Management > DHCP Server > Option 82 Settings.
Figure 4.99 Management > DHCP Server > Option 82 Settings
The following table describes the items in the previous figure.
Item Description
Entry
Circuit ID Format
Click the drop-down menu to select an entry for the Option 82 setting.
Click the drop-down menu to select the format of the circuit ID: string or hex.
Circuit ID Content Enter the circuit ID string on the switch on which the request was received.
Remote ID Format Click the drop-down menu to select the format of the remote ID: string or hex.
Remote ID Content Enter the remote ID string of the host.
Low IP Address Type in the value designating the lowest range in the IP address pool.
High IP Address
Subnet Mask
Type in the value designating the highest range in the IP address pool.
Type in the value designating the subnet mask for the IP address pool.
Gateway
DNS
Apply
Type in the value designating the gateway for the IP address pool.
Type in the value designating the DNS for the IP address pool.
Click Apply to save the values and update the screen.
The ensuing table for Entry Information settings are informational only and display the following: Entry (click the drop-down menu to select an entry), Entry ID, Circuit ID
Format, Circuit ID Content, Remote ID Format, Remote ID Content, Low IP Address,
96 EKI-9628G User Manual
High IP Address, Subnet Mask, Gateway, DNS, Edit (click to modify the settings) and
Clear (click to clear the settings).
4.10.4.6
Lease Entry
To access this page, click Management > DHCP Server > Lease Entry.
The ensuing table for Lease entry Table settings are informational only and display the following: IP Address, Client Mac, Start Time, End Time and Type.
4.10.5
SMTP Client
Simple Mail Transfer Protocol (SMTP) is a protocol to send e-mail messages between servers. SMTP is used to send messages from a mail client to a mail server.
SMTP by default uses TCP port 25.
4.10.5.1
Global Settings
The Global Settings page allows you to set the active profile for the SMTP client.
To access this page, click Management > SMTP Client > Global Settings.
Figure 4.100 Management > SMTP Client > Global Settings
The following table describes the items in the previous figure.
Item
Active Profile
Apply
Description
Click the drop-down menu to select the profile status (None, 1 or 2).
Click Apply to save the values and update the screen.
The ensuing table for SMTP Information settings are informational only and display the following: Active Profile Id.
4.10.5.2
Profile Settings
The Profile Settings page allows you to select the server IP, the server port, and sender mail for the listed profile.
To access this page, click Management > SMTP Client > Profile Settings.
Figure 4.101 Management > SMTP Client > Profile Settings > Profile Settings
EKI-9628G User Manual 97
The following table describes the items in the previous figure.
Item
Profile ID
Server IP
Server Port
Sender Mail
Apply
Description
Click the drop-down menu to select the identification type for the profile (1 or 2).
Enter the IP address to designate the server host.
Enter the port number to designate the port associated with the server
IP address.
Enter the email address of the sender client.
Click Apply to save the values and update the screen.
Figure 4.102 Management > SMTP Client > Profile Settings > Profile Target Mail
Settings
The following table describes the items in the previous figure.
Item
Profile ID
Target Mail
Apply
Description
Click the drop-down menu to select the identification type for the profile (1 or 2).
Enter the email address of the target client.
Click Apply to save the values and update the screen.
The ensuing table for Profile Information settings are informational only and display the following: Profile ID (click the drop-down menu to select a profile ID), Server IP,
Server Port and Sender Mail Address.
98 EKI-9628G User Manual
4.10.5.3
Sending Message
The Sending Message page allows you to setup the log message for use with the
SMTP client.
To access this page, click Management > SMTP Client > Sending Message.
Figure 4.103 Management > SMTP Client > Sending Message
The following table describes the items in the previous figure.
Item
Title
Content
Apply
Description
Assign the title of the email. The maximum length is 20 characters
(alphanumeric, symbols (. (dot), _ (underline), - (dash line) and space).
Assign the content of the email. The maximum length is 64 characters
(alphanumeric, symbols (. (dot), _ (underline), - (dash line) and space).
Click Apply to save the values and update the screen.
EKI-9628G User Manual 99
4.10.6
RMON
Remote monitoring (RMON) uses a client-server model to monitor/manage remote devices on a network.
4.10.6.1
RMON Statistics
The RMON Statistics page allows you to view information regarding packet sizes and information for physical layer errors. The information displayed is according to the
RMON standard.
To access this page, click Management > RMON > RMON Statistics.
Figure 4.104 Management > RMON > Rmon Statistics
The following table describes the items in the previous figure.
Item
Index
Port
Owner
Apply
Description
Enter an entry selection (1 to 65535) to display its statistical information.
Enter the respective port number for the selected entry.
Enter the name of the owner of the RMON group.
Click Apply to save the values and update the screen.
The ensuing table for Statistics Information settings are informational only and display the following: Index, Port, Drop Events, Octets, Packets, Broadcast, Multicast,
Owner and Delete (click to delete the desired index).
4.10.6.2
RMON History
The RMON History page allows you to configure the display of history entries.
To access this page, click Management > RMON > RMON History.
Figure 4.105 Management > RMON > RMON History
100 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item Description
Index Enter the index entry (1 to 65535) to select the number of new history table entries.
Select the specific port switch.
Port
Buckets Requested Enter the specific (1-50) number of samples to store.
Interval Enter value in seconds (1 to 3600) to designate a specific interval time for the collection of samples.
Owner
Apply
Enter the name of the owner of the RMON history group.
Click Apply to save the values and update the screen.
The ensuing table for History Information settings are informational only and display the following: Index, Port, Buckets Requested, Interval, Owner and Delete (click to delete the desired index).
4.10.6.3
RMON Alarm
The RMON Alarm page allows you to configure RMON statistics group and alarm groups.
To access this page, click Management > RMON > RMON Alarm.
Figure 4.106 Management > RMON > Rmon Alarm
The following table describes the items in the previous figure.
Item Description
Index Enter the index entry (1 to 65535) to define a specific Alarm Collection history entry.
Interval Enter a value (1 to 2147483647) to define the interval value for the
Alarm Collection history.
Enter the alarm variables to define the monitoring triggers.
Variable
Sample Type
Rising Threshold
Enter the variable sample type.
Enter the rising alarm threshold trigger.
Falling Threshold Enter the falling alarm threshold trigger.
Rising Event Index Enter the rising event index (1-65535) to define the alarm group.
EKI-9628G User Manual 101
Item Description
Falling Event Index Enter the falling event index (1-65535) to define the alarm group.
Owner Enter the name of the owner of the RMON alarm group.
Apply Click Apply to save the values and update the screen.
The ensuing table for Alarm Information settings are informational only and display the following: Index, Interval, Variable, Sample Type, Rising Threshold, Falling
Threshold, Rising Event Index, Falling Event Index, Owner and Delete (click to delete the desired index).
4.10.6.4
RMON Event
The RMON Event page is used to configure RMON event groups.
To access this page, click Management > RMON > RMON Event.
Figure 4.107 Management > RMON > RMON Event
The following table describes the items in the previous figure.
Item
Index
Description
Type
Community
Owner
Apply
Description
Enter the index entry (1 to 65535) to define a specific RMON event.
Enter a value (1 to 2147483647) to define the interval value for the
Alarm Collection history.
Click the drop-down menu to define the event type: None, Log, SNMP
Trap, Log and Trap.
Enter the community string to be passed for the specified event.
Enter the name of the owner of the RMON event.
Click Apply to save the values and update the screen.
The ensuing table for Event Information settings are informational only and display the following: Index, Description, Type, Community, Owner and Delete (click to delete the desired index).
102 EKI-9628G User Manual
4.11
Diagnostics
Through the Diagnostics function configuration of settings for the switch diagnostics is available.
4.11.1
Cable Diagnostics
The Cable Diagnostics page allows you to select the port for applying a copper test.
To access this page, click Diagnostics > Cable Diagnostics.
Figure 4.108 Diagnostics > Cable Diagnostics
The following table describes the items in the previous figure.
Item
Port
Description
Click the drop-down menu to select a pre-defined port for diagnostic testing. Giga ports are displayed with a channel A to D designation.
Click Copper Test to display the test result for the selected port.
Copper Test
The ensuing table for Test Result settings are informational only and display the following: Port, Channel A, Cable Length A, Channel B, Cable Length B, Channel C,
Cable Length C, Channel D and Cable Length D.
EKI-9628G User Manual 103
4.11.2
Ping Test
The Ping Test page allows you to configure the test log page.
To access this page, click Diagnostics > Ping Test.
Figure 4.109 Diagnostics > Ping Test
The following table describes the items in the previous figure.
Item
IP Address
Count
Interval (in sec)
Size (in bytes)
Description
Enter the IP address or host name of the station to ping. The initial value is blank. The IP Address or host name you enter is not retained across a power cycle. Host names are composed of series of labels concatenated with periods. Each label must be between 1 and 63 characters long, maximum of 64 characters.
Enter the number of echo requests to send. The default value is 4.
The value ranges from 1 to 5. The count entered is not retained across a power cycle.
Enter the interval between ping packets in seconds. The default value is 1. The value ranges from 1 to 5. The interval entered is not retained across a power cycle.
Enter the size of ping packet. The default value is 56. The value ranges from 8 to 5120. The size entered is not retained across a power cycle.
104 EKI-9628G User Manual
Item
Ping Results
Description
Display the reply format of ping.
PING 172.17.8.254 (172.17.8.254): 56 data bytes
--- 172.17.8.254 ping statistics ---
4 packets transmitted, 0 packets received, 100% packet loss
Or
PING 172.17.8.93 (172.17.8.93): 56 data bytes
64 bytes from 172.17.8.93: icmp_seq=0 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=1 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=2 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=3 ttl=128 time=0.0 ms
--- 172.17.8.93 ping statistics ---
4 packets transmitted, 4 packets received, 0% packet loss round-trip min/avg/max = 0.0/0.0/0.0 ms
Click Apply to display ping result for the IP address.
Apply
4.11.3
IPv6 Ping Test
The IPv6 Ping Test page allows you to configure the Ping Test for IPv6.
To access this page, click Diagnostics > IPv6 Ping Test.
Figure 4.110 Diagnostics > IPv6 Ping Test
EKI-9628G User Manual 105
The following table describes the items in the previous figure.
Item
IPv6 Address
Count
Interval (in sec)
Size (in bytes)
Ping Results
Apply
Description
Enter the IP address or host name of the station you want the switch to ping. The initial value is blank. The IP Address or host name you enter is not retained across a power cycle. Host names are composed of series of labels concatenated with dots. Each label must be between 1 and 63 characters long, and the entire hostname has a maximum of 64 characters.
Enter the number of echo requests you want to send. The default value is 4. The value ranges from 1 to 5. The count you enter is not retained across a power cycle.
Enter the interval between ping packets in seconds. The default value is 1. The value ranges from 1 to 5. The interval you enter is not retained across a power cycle.
Enter the size of ping packet. The default value is 56. The value ranges from 8 to 5120. The size you enter is not retained across a power cycle.
Display the reply format of ping.
PING 2222:777 (2222:777): 56 data bytes
--- 2222:777 ping statistics ---
4 packets transmitted, 0 packets received, 100% packet loss
Or
PING 2222:717 (2222:717): 56 data bytes
64 bytes from 2222:717: icmp6_seq=0 ttl=128 time=10.0 ms
64 bytes from 2222:717: icmp6_seq=1 ttl=128 time=0.0 ms
64 bytes from 2222:717: icmp6_seq=2 ttl=128 time=0.0 ms
64 bytes from 2222:717: icmp6_seq=3 ttl=128 time=0.0 ms
--- 2222:717 ping statistics ---
4 packets transmitted, 4 packets received, 0% packet loss round-trip min/avg/max = 0.0/2.5/10.0 ms
Click Apply to display ping result for the IP address.
4.11.4
System Log
4.11.4.1
Logging Service
The Logging Service page allows you to setup the logging services feature for the system log.
To access this page, click Diagnostics > System Log > Logging Service.
Figure 4.111 Diagnostics > System Log > Logging Service
The following table describes the items in the previous figure.
Item
Logging Service
Apply
Description
Click Enabled or Disabled to set the Logging Service status.
Click Apply to save the values and update the screen.
106 EKI-9628G User Manual
The ensuing table for Logging Information settings are informational only and display the following: Logging Service.
4.11.4.2
Local Logging
The Local Logging page allows you to designate a local target when the severity criteria is reached.
To access this page, click Diagnostics > System Log > Local Logging.
Figure 4.112 Diagnostics > System Log > Local Logging
The following table describes the items in the previous figure.
Item
Target
Severity
Description
Enter the local logging target.
Click the drop-down menu to select the severity level for local log messages.
The level options are:
emerg: Indicates system is unusable. It is the highest level of severity
alert: Indicates action must be taken immediately
crit: Indicates critical conditions
error: Indicates error conditions
warning: Indicates warning conditions
notice: Indicates normal but significant conditions
info: Indicates informational messages
debug: Indicates debug-level messages
Click Apply to save the values and update the screen.
Apply
The ensuing table for Local Logging Settings Status settings are informational only and display the following: Status, Target, Severity and Delete (click to delete the desired target).
EKI-9628G User Manual 107
4.11.4.3
System Log Server
The System Log Server page allows you to configure the log server.
To access this page, click Diagnostics > System Log > System Log Server.
Figure 4.113 Diagnostics > System Log > System Log Server
The following table describes the items in the previous figure.
Item
Server Address
Server Port
Severity
Facility
Description
Enter the IP address of the log server.
Enter the Udp port number of the log server.
Click the drop-down menu to select the severity level for local log messages. The default is emerg.
The level options are:
emerg: Indicates system is unusable. It is the highest level of severity
alert: Indicates action must be taken immediately
crit: Indicates critical conditions
error: Indicates error conditions
warning: Indicates warning conditions
notice: Indicates normal but significant conditions
info: Indicates informational messages
debug: Indicates debug-level messages
Click the drop-down menu to select facility to which the message refers.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Remote Logging Setting Status settings are informational only and display the following: Status, Server Info, Severity, Facility and Delete (click to delete the desired server address).
4.11.5
DDM
The DDM page allows you to setup the diagnostic alarm status.
To access this page, click Diagnostics > DDM.
Figure 4.114 Diagnostics > DDM
108 EKI-9628G User Manual
The following table describes the items in the previous figure.
Item
Diagnostic Alarm
Description
Click the drop-down menu to designate the announcement method:
Disabled, SysLog, E-mail, or SNMP.
Click Apply to save the values and update the screen.
Apply
The ensuing table for Diagnostic Alarm Information settings are informational only and display the following: Diagnostic Alarm.
Figure 4.115 Diagnostics > DDM
The following table describes the items in the previous figure.
Item
High Alarm
High Warning
Low Alarm
Low Warning
Apply
Description
Click Enabled or Disabled to set the alarm state.
Click Enabled or Disabled to set the alarm state.
Click Enabled or Disabled to set the alarm state.
Click Enabled or Disabled to set the alarm state.
Click Apply to save the values and update the screen.
The ensuing table for Vendor Info settings are informational only and display the following: Refresh (click to reload the vendor information), Port, Connector, Speed,
VendorName, VendorOui, VendorPn, VendorRev, VendorSn and DateCode.
4.11.6
LED Indication
To access this page, click Diagnostics > LED Indication.
EKI-9628G User Manual
Figure 4.116 Diagnostics > LED Indication
109
The following table describes the items in the previous figure.
Item
LED
State
Event
Apply
Description
Click the drop-down menu to select LED indicator.
Select Enable or Disable to enable LED alarm.
Click to select the event of LED alarm.
Click Apply to save the values and update the screen.
The ensuing table for LED Information lists the following settings (informational only): LED and State.
The ensuing table for Event Information lists the following settings (informational only): LED, Event, State, and Delete.
4.12
Tools
4.12.1
Backup Manager
The Backup Manager page allows you to configure a remote TFTP sever or host file system in order to backup the firmware image or configuration file.
To access this page, click Tools > Backup Manager.
Figure 4.117 Tools > Backup Manager
The following table describes the items in the previous figure.
Item
Backup Method
Server IP
Backup Type
Image
Backup
Description
Click the drop-down menu to select the backup method: TFTP or
HTTP.
Enter the IP address of the backup server.
Click a type to define the backup method: image: running configuration, startup configuration, flash log, or buffered log.
Click the format for the image type: 9612G_1_00_13.bix (Active) or vmlinux.bix (backup).
Click Backup to backup the settings.
110 EKI-9628G User Manual
4.12.2
Upgrade Manager
The Upgrade Manager page allows you to configure a remote TFTP sever or host file system in order to upload firmware upgrade images or configuration files.
To access this page, click Tools > Upgrade Manager.
Figure 4.118 Tools > Upgrade Manager
The following table describes the items in the previous figure.
Item
Upgrade Method
Server IP
File Name
Upgrade Type
Image
Upgrade
Description
Click the drop-down menu to select the upgrade method: TFTP or
HTTP.
Enter the IP address of the upgrade server.
Enter the file name of the new firmware version.
Click a type to define the upgrade method: image, startup configuration, or running configuration.
Click the format for the image type: 9612G_1_00_13.bix (Active) or vmlinux.bix (backup).
Click Upgrade to upgrade to the current version.
4.12.3
Dual Image
The Dual Image page allows you to setup an active and backup partitions for firmware image redundancy.
To access this page, click Tools > Dual Image.
EKI-9628G User Manual
Figure 4.119 Tools > Dual Image
111
The following table describes the items in the previous figure.
Item
Active Image
Description
Click the format for the image type: Partition0 (Active) or Partition1
(backup).
Click Save to save and keep the new settings.
Save
The ensuing table for Image Information 0/1 settings are informational only and display the following: Flash Partition, Image Name, Image Size and Created Time.
4.12.4
Save Configuration
To access this page, click Tools > Save Configuration.
Click Save Configuration to FLASH to have configuration changes you have made to be saved across a system reboot. All changes submitted since the previous save or system reboot will be retained by the switch.
4.12.5
User Account
The User Account page allows you to setup a user and the related parameters.
To access this page, click Tools > User Account.
Figure 4.120 Tools > User Account
The following table describes the items in the previous figure.
Item
User Name
Password Type
Password
Retype Password
Privilege Type
Description
Enter the name of the new user entry.
Click the drop-down menu to define the type of password: Clear Text,
Encrypted or No Password.
Enter the character set for the define password type.
Retype the password entry to confirm the profile password.
Click the drop-down menu to designate privilege authority for the user entry: Admin or User.
Click Apply to create a new user account.
Apply
The ensuing table for Local Users settings are informational only and display the following: User Name, Password Type, Privilege Type and Delete (click to delete the desired user account).
112 EKI-9628G User Manual
4.12.6
Reset System
To access this page, click Tools > Reset System.
Click Reset to have all configuration parameters reset to their factory default values.
Click except for to select the configuration are excepted. All changes that have been made will be lost, even if you have issued a save.
Reset settings take effect after a system reboot.
4.12.7
Reboot Device
To access this page, click Tools > Reboot Device.
Click Reboot to reboot the switch. Any configuration changes you have made since the last time you issued a save will be lost.
4.13
Modbus/TCP Mapping
The data map addresses of Advantech switches shown in the following table start from Modbus address 30001 for function code 4.
In the given example, the address offset 0x1000 (hex) equals Modbus address
34097, while the address offset 0x1100 (hex) equals Modbus address 34353.
The information given by the Advantech is shown in hex mode.
4.13.1
Modbus/TCP Mapping Table
Catelog Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x0000 30001
Description
Vendor ID = 0x13FE System Info Vendor ID =
0x‘13FE
Unit ID =
0xFF
1 word
1 word
16 bits
16 bits
HEX
HEX
Product Code 1 word 16 bits HEX
Vendor Name
= "Advantech"
16 words 32 chars ASCII
0x0001
0x0002
0x0010
30002
30003
30017
Unit ID = 0xFF
Product Code
Vendor Name =
"Advantech"
Word 0 Hi byte = 'A'
Word 0 Lo byte = 'd'
Word 1 Hi byte = 'v'
Word 1 Lo byte = 'a'
Word 2 Hi byte = 'n'
Word 2 Lo byte = 't'
Word 3 Hi byte = 'e'
Word 3 Lo byte = 'c'
Word 4 Hi byte = 'h'
Word 4 Lo byte = '\0'
EKI-9628G User Manual 113
Catelog
Port Info
Name
System Info Product
Name = "EKIxxxx"
Firmware
Version
Ethernet
MAC Address
Revision
Number
IP Address
Port Status
Port 1 Status
Port 2 Status
Data Type
16 words 32 chars ASCII
2 words
3 words
16 words 32 chars ASCII
2 words
1 word
1 word
1 word
32 bits
48 bits
32 bits
16 bits
16 bits
16 bits
Interpretation
HEX
HEX
HEX
HEX
HEX
HEX
Address Offset
(Hex)
Address
3X
0x0020 30033
0x020A
0x020E
0x0211
0x0400
0x1000 ~
0x101F
30523
30527
30530
31025
34097 ~
34128
Description
Product Name =
"EKI-xxxx"
Word 0 Hi byte = 'E'
Word 0 Lo byte = 'K'
Word 1 Hi byte = 'I'
Word 1 Lo byte = '-'
Word 2 Hi byte = 'x'
Word 2 Lo byte = 'x'
Word 3 Hi byte = 'x'
Word 3 Lo byte = 'x'
Word 4 Hi byte = '\0'
Firmware Version
Word 0 Hi byte = major
Word 0 Lo byte = minor
Word 1 Hi byte = release
Word 1 Lo byte = build
Ethernet MAC
Address
Ex: MAC = 00-19-
CB-01-02-03
Word 0 Hi byte =
0x00
Word 0 Lo byte =
0x19
Word 1 Hi byte =
0xCB
Word 1 Lo byte =
0x01
Word 2 Hi byte =
0x02
Word 2 Lo byte =
0x03
Product Name =
"YYY.xxxxx"
Word 0 Hi byte = 'Y'
Word 0 Lo byte = 'Y'
Word 1 Hi byte = 'Y'
Word 1 Lo byte = '.'
Word 2 Hi byte = 'x'
Word 2 Lo byte = 'x'
Word 3 Hi byte = 'x'
Word 3 Lo byte = 'x'
Word 4 Hi byte = 'x'
Word 4 Hi byte = '\0'
IP Address
Ex: IP = 192.168.1.1
Word 0 Hi byte =
0xC0
Word 0 Lo byte =
0xA8
Word 1 Hi byte =
0x01
Word 1 Lo byte =
0x01
Port Status
0x0000: Link down
0x0001: Link up
0xFFFF: No port
0x1000
0x1001
34097
34098
114 EKI-9628G User Manual
Catelog
Port Info
Name Data Type
Port 3 Status 1 word 16 bits HEX
Port 4 Status 1 word 16 bits HEX
Port 5 Status 1 word 16 bits HEX
Port 6 Status 1 word 16 bits HEX
Port 7 Status 1 word 16 bits HEX
Port 19 Status
Port 20 Status
Port 21 Status
Port 22 Status
Port 23 Status
Port 24 Status
Port 25 Status
Port 26 Status
Port 8 Status 1 word 16 bits HEX
Port 9 Status 1 word 16 bits HEX
Port 10 Status
1 word 16 bits HEX
Port 11 Status 1 word 16 bits HEX
Port 12 Status
1 word 16 bits HEX
1 word 16 bits HEX Port 13 Status
Port 14 Status
1 word 16 bits HEX
1 word 16 bits HEX Port 15 Status
Port 16 Status
Port 17 Status
Port 18 Status
1 word
1 word
1 word
16 bits
16 bits
16 bits
HEX
HEX
HEX
1 word 16 bits HEX
1 word
1 word
1 word
1 word
1 word
1 word
1 word
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
1 word 16 bits HEX Port 27 Status
Port 28 Status
1 word 16 bits HEX
1 word 16 bits HEX Port 29 Status
Port 30 Status
Port 31 Status
Port 32 Status
1 word
1 word
1 word
16 bits
16 bits
16 bits
HEX
HEX
HEX
Interpretation Address Offset
(Hex)
Address
3X
0x1002
0x1003
0x1004
0x1005
0x1006
0x1007
0x1008
0x1009
34099
34100
34101
34102
34103
34104
34105
34106
Description
0x100A
0x100B
34107
34108
0x100C
0x100D
0x100E
0x100F
0x1010
0x1011
0x1012
0x1013
0x1014
0x1015
0x1016
0x1017
0x1018
0x1019
0x101A
0x101B
0x101C
0x101D
0x101E
0x101F
34109
34110
34111
34112
34113
34114
34115
34116
34117
34118
34119
34120
34121
34122
34123
34124
34125
34126
34127
34128
EKI-9628G User Manual 115
Catelog
Port Info
Name Data Type
Port Speed 1 word 16 bits
Port 1 Speed 1 word 16 bits
Port 2 Speed 1 word 16 bits
Port 3 Speed 1 word 16 bits
Port 4 Speed 1 word 16 bits
Port 5 Speed 1 word 16 bits
Port 6 Speed 1 word 16 bits
Port 7 Speed 1 word 16 bits
Port 24
Speed
Port 25
Speed
Port 26
Speed
Port 27
Speed
Port 28
Speed
Port 16
Speed
Port 17
Speed
Port 18
Speed
Port 19
Speed
Port 20
Speed
Port 21
Speed
Port 22
Speed
Port 23
Speed
Port 8 Speed 1 word 16 bits
Port 9 Speed 1 word 16 bits
1 word 16 bits Port 10
Speed
Port 11
Speed
1 word 16 bits
1 word 16 bits Port 12
Speed
Port 13
Speed
Port 14
Speed
Port 15
Speed
1 word
1 word
1 word
16 bits
16 bits
16 bits
1 word 16 bits
1 word
1 word
1 word
1 word
1 word
1 word
1 word
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
1 word 16 bits
1 word
1 word
1 word
1 word
16 bits
16 bits
16 bits
16 bits
Interpretation
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
0x1100
0x1101
0x1102
0x1103
0x1104
0x1105
0x1106
0x1107
0x1108
0x1109
Address Offset
(Hex)
Address
3X
0x1100 ~
0x111F
34353 ~
34384
Description
Port Speed
0x0000: 10M-Half
0x0001: 10M-Full
0x0002: 100M-Half
0x0003: 100M-Full
0x0004: 1000M-Half
0x0005: 1000M-Full
0xFFFF: No port
34353
34354
34355
34356
34357
34358
34359
34360
34361
34362
0x110A
0x110B
0x110C
0x110D
0x110E
0x110F
0x1110
0x1111
0x1112
0x1113
0x1114
0x1115
0x1116
0x1117
0x1118
0x1119
0x111A
0x111B
34363
34364
34365
34366
34367
34368
34369
34370
34371
34372
34373
34374
34375
34376
34377
34378
34379
34380
116 EKI-9628G User Manual
Catelog Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x111C 34381
Description
Port Info Port 29
Speed
1 word 16 bits HEX
Port 30
Speed
Port 31
Speed
1 word
1 word
16 bits
16 bits
HEX
HEX
Port 32
Speed
1 word 16 bits HEX
Flow Control 1 word 16 bits HEX
Port 9 Flow
Control
Port 10 Flow
Control
Port 11 Flow
Control
Port 12 Flow
Control
Port 13 Flow
Control
Port 14 Flow
Control
Port 15 Flow
Control
Port 16 Flow
Control
Port 1 Flow
Control
Port 2 Flow
Control
Port 3 Flow
Control
Port 4 Flow
Control
Port 5 Flow
Control
Port 6 Flow
Control
Port 7 Flow
Control
Port 8 Flow
Control
Port 17 Flow
Control
Port 18 Flow
Control
Port 19 Flow
Control
Port 20 Flow
Control
Port 21 Flow
Control
Port 22 Flow
Control
Port 23 Flow
Control
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
0x111D
0x111E
0x111F
0x1200 ~
0x121F
0x1200
0x1201
0x1202
0x1203
0x1204
0x1205
0x1206
0x1207
0x1208
0x1209
0x120A
0x120B
0x120C
0x120D
0x120E
0x120F
0x1210
0x1211
0x1212
0x1213
0x1214
0x1215
0x1216
34382
34383
34384
34609 ~
34640
Flow Control
0x0000: Off
0x0001: On
0xFFFF: No port
34609
34610
34611
34612
34613
34614
34615
34616
34617
34618
34619
34620
34621
34622
34623
34624
34625
34626
34627
34628
34629
34630
34631
EKI-9628G User Manual 117
Catelog
Port Info
Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x1217 34632
Description
Port 24 Flow
Control
Port 25 Flow
Control
Port 26 Flow
Control
Port 27 Flow
Control
Port 28 Flow
Control
Port 29 Flow
Control
Port 30 Flow
Control
Port 31 Flow
Control
Port 32 Flow
Control
Port Description
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
20 words 40 chars ASCII
Port 1
Description
Port 2
Description
Port 3
Description
Port 4
Description
Port 5
Description
Port 6
Description
Port 7
Description
Port 8
Description
Port 9
Description
Port 10
Description
Port 11
Description
Port 12
Description
Port 13
Description
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
0x1218
0x1219
0x121A
0x121B
0x121C
0x121D
0x121E
0x121F
0x1400 ~
0x166C
0x1400
0x1414
0x1428
0x143C
0x1450
0x1464
0x1478
0x148C
0x14A0
0x14B4
0x14C8
0x14DC
0x14F0
34633
34634
34635
34636
34637
34638
34639
34640
35121 ~
35741
Port Description
Port Description =
"100RX,RJ45."
Word 0 Hi byte = '1'
Word 0 Lo byte = '0'
Word 1Hi byte = '0'
Word 1 Lo byte = ‘R’
Word 2 Hi byte = 'X'
Word 2 Lo byte = ‘,’
Word 3 Hi byte = 'R'
Word 3 Lo byte = ‘J’
Word 4 Hi byte = ‘4’
Word 4 Lo byte = ‘5’
Word 5 Hi byte = ‘.’
Word 5 Lo byte = ‘\0’
35121
35141
35161
35181
35201
35221
35241
35261
35281
35301
35321
35341
35361
118 EKI-9628G User Manual
Catelog
Port Info
Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x1504 35381
Description
Port 22
Description
Port 23
Description
Port 24
Description
Port 25
Description
Port 26
Description
Port 27
Description
Port 28
Description
Port 29
Description
Port 14
Description
Port 15
Description
Port 16
Description
Port 17
Description
Port 18
Description
Port 19
Description
Port 20
Description
Port 21
Description
Port 30
Description
Port 31
Description
Port 32
Description
Link Up
Counter
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
20 words 40 chars ASCII
1 word 16 bits HEX
Port 1 Link
Up Counter
Port 2 Link
Up Counter
Port 3 Link
Up Counter
Port 4 Link
Up Counter
Port 5 Link
Up Counter
Port 6 Link
Up Counter
Port 7 Link
Up Counter
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
0x1518
0x152C
0x1540
0x1554
0x1568
0x157C
0x1590
0x15A4
0x15B8
0x15CC
0x15E0
0x15F4
0x1608
0x161C
0x1630
0x1644
0x1658
0x166C
0x1700 ~
0x171F
0x1700
0x1701
0x1702
0x1703
0x1704
0x1705
0x1706
35401
35421
35441
35461
35481
35501
35521
35541
35561
35581
35601
35621
35641
35661
35681
35701
35721
35741
35889 ~
35920
Link Up Counter
Ex: port link up counter = 13
Received MODBUS response: 0x000D
35889
35890
35891
35892
35893
35894
35895
EKI-9628G User Manual 119
Catelog
Port Info
Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x1707 35896
Description
Port 16 Link
Up Counter
Port 17 Link
Up Counter
Port 18 Link
Up Counter
Port 19 Link
Up Counter
Port 20 Link
Up Counter
Port 21 Link
Up Counter
Port 22 Link
Up Counter
Port 23 Link
Up Counter
Port 8 Link
Up Counter
Port 9 Link
Up Counter
Port 10 Link
Up Counter
Port 11 Link
Up Counter
Port 12 Link
Up Counter
Port 13 Link
Up Counter
Port 14 Link
Up Counter
Port 15 Link
Up Counter
Port 24 Link
Up Counter
Port 25 Link
Up Counter
Port 26 Link
Up Counter
Port 27 Link
Up Counter
Port 28 Link
Up Counter
Port 29 Link
Up Counter
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
Port 30 Link
Up Counter
Port 31 Link
Up Counter
1 word
1 word
16 bits
16 bits
Port 32 Link
Up Counter
1 word 16 bits
PoE Voltage 1 word 16 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
Port 1 PoE
Voltage
Port 2 PoE
Voltage
1 word 16 bits
1 word 16 bits
HEX
HEX
0x1708
0x1709
0x170A
0x170B
0x170C
0x170D
0x170E
0x170F
0x1710
0x1711
0x1712
0x1713
0x1714
0x1715
0x1716
0x1717
0x1718
0x1719
0x171A
0x171B
0x171C
0x171D
0x171E
0x171F
0x1800 ~
0x181F
0x1800
0x1801
35897
35898
35899
35900
35901
35902
35903
35904
35905
35906
35907
35908
35909
35910
35911
35912
35913
35914
35915
35916
35917
35918
35919
35920
36145 ~
36176
PoE Voltage (V)
Ex: poe voltage = 5
Received MODBUS response: 0x0005
36145
36146
120 EKI-9628G User Manual
Catelog
Port Info
Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x1802 36147
Description
Port 11 PoE
Voltage
Port 12 PoE
Voltage
Port 13 PoE
Voltage
Port 14 PoE
Voltage
Port 15 PoE
Voltage
Port 16 PoE
Voltage
Port 17 PoE
Voltage
Port 18 PoE
Voltage
Port 3 PoE
Voltage
Port 4 PoE
Voltage
Port 5 PoE
Voltage
Port 6 PoE
Voltage
Port 7 PoE
Voltage
Port 8 PoE
Voltage
Port 9 PoE
Voltage
Port 10 PoE
Voltage
Port 19 PoE
Voltage
Port 20 PoE
Voltage
Port 21 PoE
Voltage
Port 22 PoE
Voltage
Port 23 PoE
Voltage
Port 24 PoE
Voltage
Port 25 PoE
Voltage
Port 26 PoE
Voltage
Port 27 PoE
Voltage
Port 28 PoE
Voltage
Port 29 PoE
Voltage
Port 30 PoE
Voltage
Port 31 PoE
Voltage
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
0x1803
0x1804
0x1805
0x1806
0x1807
0x1808
0x1809
0x180A
0x180B
0x180C
0x180D
0x180E
0x180F
0x1810
0x1811
0x1812
0x1813
0x1814
0x1815
0x1816
0x1817
0x1818
0x1819
0x181A
0x181B
0x181C
0x181D
0x181E
36148
36149
36150
36151
36152
36153
36154
36155
36156
36157
36158
36159
36160
36161
36162
36163
36164
36165
36166
36167
36168
36169
36170
36171
36172
36173
36174
36175
EKI-9628G User Manual 121
Catelog
Port Info
Name Data Type
Port 32 PoE
Voltage
1 word 16 bits
PoE Current 1 word 16 bits
Interpretation
HEX
HEX
Address Offset
(Hex)
Address
3X
0x181F 36176
Description
0x1820 ~
0x183F
36177 ~
36208
36177
PoE Current (mA)
Ex: poe current = 13
Received MODBUS response: 0x000D
Port 9 PoE
Current
Port 10 PoE
Current
Port 11 PoE
Current
Port 12 PoE
Current
Port 13 PoE
Current
Port 14 PoE
Current
Port 15 PoE
Current
Port 16 PoE
Current
Port 1 PoE
Current
Port 2 PoE
Current
Port 3 PoE
Current
Port 4 PoE
Current
Port 5 PoE
Current
Port 6 PoE
Current
Port 7 PoE
Current
Port 8 PoE
Current
Port 17 PoE
Current
Port 18 PoE
Current
Port 19 PoE
Current
Port 20 PoE
Current
Port 21 PoE
Current
Port 22 PoE
Current
Port 23 PoE
Current
Port 24 PoE
Current
Port 25 PoE
Current
Port 26 PoE
Current
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
0x1820
0x1821
0x1822
0x1823
0x1824
0x1825
0x1826
0x1827
0x1828
0x1829
0x182A
0x182B
0x182C
0x182D
0x182E
0x182F
0x1830
0x1831
0x1832
0x1833
0x1834
0x1835
0x1836
0x1837
0x1838
0x1839
36178
36179
36180
36181
36182
36183
36184
36185
36186
36187
36188
36189
36190
36191
36192
36193
36194
36195
36196
36197
36198
36199
36200
36201
36202
122 EKI-9628G User Manual
Catelog
Port Info
Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x183A 36203
Description
Port 27 PoE
Current
Port 28 PoE
Current
Port 29 PoE
Current
Port 30 PoE
Current
1 word
1 word
1 word
1 word
16 bits
16 bits
16 bits
16 bits
HEX
HEX
HEX
HEX
Port 31 PoE
Current
Port 32 PoE
Current
1 word
1 word
16 bits
16 bits
HEX
HEX
PoE Power 1 word 16 bits HEX
Port 9 PoE
Power
Port 10 PoE
Power
Port 11 PoE
Power
Port 12 PoE
Power
Port 13 PoE
Power
Port 14 PoE
Power
Port 15 PoE
Power
Port 16 PoE
Power
Port 1 PoE
Power
Port 2 PoE
Power
Port 3 PoE
Power
Port 4 PoE
Power
Port 5 PoE
Power
Port 6 PoE
Power
Port 7 PoE
Power
Port 8 PoE
Power
Port 17 PoE
Power
Port 18 PoE
Power
Port 19 PoE
Power
Port 20 PoE
Power
Port 21 PoE
Power
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
0x183B
0x183C
0x183D
0x183E
0x183F
0x1840 ~
0x185F
0x1840
0x1841
0x1842
0x1843
0x1844
0x1845
0x1846
0x1847
0x1848
0x1849
0x184A
0x184B
0x184C
0x184D
0x184E
0x184F
0x1850
0x1851
0x1852
0x1853
0x1854
36204
36205
36206
36207
36208
36209 ~
36240
PoE Power (W)
Ex: poe power = 10
Received MODBUS response: 0x000A
36209
36210
36211
36212
36213
36214
36215
36216
36217
36218
36219
36220
36221
36222
36223
36224
36225
36226
36227
36228
36229
EKI-9628G User Manual 123
Catelog
Port Info
Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x1855 36230
Description
Port 22 PoE
Power
Port 23 PoE
Power
Port 24 PoE
Power
Port 25 PoE
Power
Port 26 PoE
Power
Port 27 PoE
Power
Port 28 PoE
Power
Port 29 PoE
Power
Port 30 PoE
Power
Port 31 PoE
Power
Port 32 PoE
Power
PoE Temperature
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
Port 1 PoE
Temperature
Port 2 PoE
Temperature
Port 3 PoE
Temperature
Port 4 PoE
Temperature
Port 5 PoE
Temperature
Port 6 PoE
Temperature
Port 7 PoE
Temperature
Port 8 PoE
Temperature
Port 9 PoE
Temperature
Port 10 PoE
Temperature
Port 11 PoE
Temperature
Port 12 PoE
Temperature
Port 13 PoE
Temperature
Port 14 PoE
Temperature
Port 15 PoE
Temperature
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
1 word 16 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
0x1856
0x1857
0x1858
0x1859
0x185A
0x185B
0x185C
0x185D
0x185E
0x185F
0x1860 ~
0x187F
0x1860
0x1861
0x1862
0x1863
0x1864
0x1865
0x1866
0x1867
0x1868
0x1869
0x186A
0x186B
0x186C
0x186D
0x186E
36231
36232
36233
36234
36235
36236
36237
36238
36239
36240
36241 ~
36272
PoE Temperature (C)
Ex: poe temperature
= 32
Received MODBUS response: 0x0020
36241
36242
36243
36244
36245
36246
36247
36248
36249
36250
36251
36252
36253
36254
36255
124 EKI-9628G User Manual
Catelog Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x186F 36256
Description
Port Info
Port 24 PoE
Temperature
Port 25 PoE
Temperature
Port 26 PoE
Temperature
Port 27 PoE
Temperature
Port 28 PoE
Temperature
Port 29 PoE
Temperature
Port 30 PoE
Temperature
Port 31 PoE
Temperature
Port 32 PoE
Temperature
Packet Info Tx Packets
Counter
Port 16 PoE
Temperature
Port 17 PoE
Temperature
Port 18 PoE
Temperature
Port 19 PoE
Temperature
Port 20 PoE
Temperature
Port 21 PoE
Temperature
Port 22 PoE
Temperature
Port 23 PoE
Temperature
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
1 word 16 bits HEX
4 words 64 bits HEX
Port 1 Tx
Packets
Port 2 Tx
Packets
Port 3 Tx
Packets
Port 4 Tx
Packets
Port 5 Tx
Packets
Port 6 Tx
Packets
Port 7 Tx
Packets
Port 8 Tx
Packets
4 words
4 words
4 words
4 words
4 words
4 words
4 words
4 words
64 bits
64 bits
64 bits
64 bits
64 bits
64 bits
64 bits
64 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
0x1870
0x1871
0x1872
0x1873
0x1874
0x1875
0x1876
0x1877
0x1878
0x1879
0x187A
0x187B
0x187C
0x187D
0x187E
0x187F
0x2000 ~
0x207C
0x2000
0x2004
0x2008
0x200C
0x2010
0x2014
0x2018
0x201C
36257
36258
36259
36260
36261
36262
36263
36264
36265
36266
36267
36268
36269
36270
36271
36272
38193 ~
38317
Tx Packets
Ex: port 1 Tx Packet
Amount = 11223344
Received MODBUS response: 0xAB4130
Word 0 = 0x0000
Word 1 = 0x0000
Word 2 = 0x00AB
Word 3 = 0x4130
38193
38197
38201
38205
38209
38213
38217
38221
EKI-9628G User Manual 125
Catelog Name
Packet Info Port 9 Tx
Packets
Port 10 Tx
Packets
Port 11 Tx
Packets
Port 12 Tx
Packets
Port 13 Tx
Packets
Port 14 Tx
Packets
Port 15 Tx
Packets
Port 16 Tx
Packets
Port 17 Tx
Packets
Port 18 Tx
Packets
Port 19 Tx
Packets
Port 20 Tx
Packets
Port 21 Tx
Packets
Port 22 Tx
Packets
Port 23 Tx
Packets
Port 24 Tx
Packets
Port 25 Tx
Packets
Port 26 Tx
Packets
Port 27 Tx
Packets
Port 28 Tx
Packets
Port 29 Tx
Packets
Port 30 Tx
Packets
Port 31 Tx
Packets
Port 32 Tx
Packets
Rx Packets
Counter
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
4 words 64 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
Port 1 Rx
Packets
Data Type
4 words 64 bits
Interpretation Address Offset
(Hex)
Address
3X
0x2020 38225
Description
HEX
0x2024
0x2028
0x202C
0x2030
0x2034
0x2038
0x203C
0x2040
0x2044
0x2048
0x204C
0x2050
0x2054
0x2058
0x205C
0x2060
0x2064
0x2068
0x206C
0x2070
0x2074
0x2078
0x207C
0x2100
~0x217C
0x2100
38229
38233
38237
38241
38245
38249
38253
38257
38261
38265
38269
38273
38277
38281
38285
38289
38293
38297
38301
38305
38309
38313
38317
38449 ~
38573
Rx Packets
Ex: port 1 Rx Packet
Amount = 11223344
Received MODBUS response: 0xAB4130
Word 0 = 0x0000
Word 1 = 0x0000
Word 2 = 0x00AB
Word 3 = 0x4130
38449
126 EKI-9628G User Manual
Catelog Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x2104 38453
Description
Packet Info Port 2 Rx
Packets
Port 3 Rx
Packets
Port 4 Rx
Packets
Port 5 Rx
Packets
Port 6 Rx
Packets
Port 7 Rx
Packets
Port 8 Rx
Packets
Port 9 Rx
Packets
Port 10 Rx
Packets
Port 11 Rx
Packets
Port 12 Rx
Packets
Port 13 Rx
Packets
Port 14 Rx
Packets
Port 15 Rx
Packets
Port 16 Rx
Packets
Port 17 Rx
Packets
Port 18 Rx
Packets
Port 19 Rx
Packets
Port 20 Rx
Packets
Port 21 Rx
Packets
Port 22 Rx
Packets
Port 23 Rx
Packets
Port 24 Rx
Packets
Port 25 Rx
Packets
Port 26 Rx
Packets
Port 27 Rx
Packets
Port 28 Rx
Packets
Port 29 Rx
Packets
Port 30 Rx
Packets
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
4 words 64 bits HEX
0x2108
0x210C
0x2110
0x2114
0x2118
0x211C
0x2120
0x2124
0x2128
0x212C
0x2130
0x2134
0x2138
0x213C
0x2140
0x2144
0x2148
0x214C
0x2150
0x2154
0x2158
0x215C
0x2160
0x2164
0x2168
0x216C
0x2170
0x2174
38457
38461
38465
38469
38473
38477
38481
38485
38489
38493
38497
38501
38505
38509
38513
38517
38521
38525
38529
38533
38537
38541
38545
38549
38553
38557
38561
38565
EKI-9628G User Manual 127
Catelog Name Data Type
Packet Info Port 31 Rx
Packets
Port 32 Rx
Packets
Tx Error
Packets
Counter
4 words 64 bits
4 words 64 bits
2 words 32 bits
HEX
HEX
HEX
Interpretation Address Offset
(Hex)
Address
3X
0x2178 38569
Description
38573 0x217C
0x2200 ~
0x223E
38705 ~
38767
38705
Tx Error Packets
Ex: port 1 Tx Packet
Amount = 11223344
Received MODBUS response: 0xAB4130
Word 0 = 0x00AB
Word 1 = 0x4130
Port 1 Tx
Error Packets
2 words 32 bits
Port 2 Tx
Error Packets
2 words 32 bits
Port 3 Tx
Error Packets
2 words 32 bits
Port 4 Tx
Error Packets
2 words 32 bits
Port 5 Tx
Error Packets
2 words 32 bits
Port 6 Tx
Error Packets
2 words 32 bits
Port 7 Tx
Error Packets
2 words 32 bits
Port 8 Tx
Error Packets
2 words 32 bits
Port 9 Tx
Error Packets
2 words 32 bits
Port 10 Tx
Error Packets
2 words 32 bits
Port 11 Tx
Error Packets
2 words 32 bits
Port 12 Tx
Error Packets
2 words 32 bits
Port 13 Tx
Error Packets
2 words 32 bits
Port 14 Tx
Error Packets
2 words 32 bits
Port 15 Tx
Error Packets
2 words 32 bits
Port 16 Tx
Error Packets
2 words 32 bits
Port 17 Tx
Error Packets
2 words 32 bits
Port 18 Tx
Error Packets
2 words 32 bits
Port 19 Tx
Error Packets
2 words 32 bits
Port 20 Tx
Error Packets
2 words 32 bits
Port 21 Tx
Error Packets
2 words 32 bits
Port 22 Tx
Error Packets
2 words 32 bits
Port 23 Tx
Error Packets
2 words 32 bits
Port 24 Tx
Error Packets
2 words 32 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
0x2200
0x2202
0x2204
0x2206
0x2208
0x220A
0x220C
0x220E
0x2210
0x2212
0x2214
0x2216
0x2218
0x221A
0x221C
0x221E
0x2220
0x2222
0x2224
0x2226
0x2228
0x222A
0x222C
0x222E
38707
38709
38711
38713
38715
38717
38719
38721
38723
38725
38727
38729
38731
38733
38735
38737
38739
38741
38743
38745
38747
38749
38751
128 EKI-9628G User Manual
Catelog Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x2230 38753
Description
Packet Info Port 25 Tx
Error Packets
2 words 32 bits HEX
Port 26 Tx
Error Packets
2 words 32 bits HEX
Port 27 Tx
Error Packets
2 words 32 bits HEX
Port 28 Tx
Error Packets
2 words 32 bits HEX
Port 29 Tx
Error Packets
2 words 32 bits HEX
Port 30 Tx
Error Packets
2 words 32 bits HEX
Port 31 Tx
Error Packets
2 words 32 bits HEX
Port 32 Tx
Error Packets
2 words 32 bits HEX
Rx Error
Packets
Counter
2 words 32 bits HEX
Port 1 Rx
Error Packets
2 words 32 bits HEX
Port 2 Rx
Error Packets
2 words 32 bits HEX
Port 3 Rx
Error Packets
2 words 32 bits HEX
Port 4 Rx
Error Packets
2 words 32 bits HEX
Port 5 Rx
Error Packets
2 words 32 bits HEX
Port 6 Rx
Error Packets
2 words 32 bits HEX
Port 7 Rx
Error Packets
2 words 32 bits HEX
Port 8 Rx
Error Packets
2 words 32 bits HEX
Port 9 Rx
Error Packets
2 words 32 bits HEX
Port 10 Rx
Error Packets
2 words 32 bits HEX
Port 11 Rx
Error Packets
2 words 32 bits HEX
Port 12 Rx
Error Packets
2 words 32 bits HEX
Port 13 Rx
Error Packets
2 words 32 bits HEX
Port 14 Rx
Error Packets
2 words 32 bits HEX
Port 15 Rx
Error Packets
2 words 32 bits HEX
Port 16 Rx
Error Packets
2 words 32 bits HEX
Port 17 Rx
Error Packets
2 words 32 bits HEX
Port 18 Rx
Error Packets
2 words 32 bits HEX
0x2232
0x2234
0x2236
0x2238
0x223A
0x223C
0x223E
0x2300 ~
0x233E
0x2300
0x2302
0x2304
0x2306
0x2308
0x230A
0x230C
0x230E
0x2310
0x2312
0x2314
0x2316
0x2318
0x231A
0x231C
0x231E
0x2320
0x2322
38755
38757
38759
38761
38763
38765
38767
38961 ~
39023
38961
38963
38965
38967
38969
38971
38973
38975
38977
38979
38981
38983
38985
38987
38989
38991
38993
38995
Rx Error Packets
Ex: port 1 Rx Packet
Amount = 11223344
Received MODBUS response: 0xAB4130
Word 0 = 0x00AB
Word 1 = 0x4130
EKI-9628G User Manual 129
Catelog Name Data Type Interpretation Address Offset
(Hex)
Address
3X
0x2324 38997
Description
Packet Info Port 19 Rx
Error Packets
2 words 32 bits
Port 20 Rx
Error Packets
2 words 32 bits
Port 21 Rx
Error Packets
2 words 32 bits
Port 22 Rx
Error Packets
2 words 32 bits
Port 23 Rx
Error Packets
2 words 32 bits
Port 24 Rx
Error Packets
2 words 32 bits
Port 25 Rx
Error Packets
2 words 32 bits
Port 26 Rx
Error Packets
2 words 32 bits
Port 27 Rx
Error Packets
2 words 32 bits
Port 28 Rx
Error Packets
2 words 32 bits
Port 29 Rx
Error Packets
2 words 32 bits
Port 30 Rx
Error Packets
2 words 32 bits
Port 31 Rx
Error Packets
2 words 32 bits
Port 32 Rx
Error Packets
2 words 32 bits
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
HEX
0x2326
0x2328
0x232A
0x232C
0x232E
0x2330
0x2332
0x2334
0x2336
0x2338
0x233A
0x233C
0x233E
38999
39001
39003
39005
39007
39009
39011
39013
39015
39017
39019
39021
39023
130 EKI-9628G User Manual
EKI-9628G User Manual 131
132 EKI-9628G User Manual
Chapter
5
Troubleshooting
5
5.1
Troubleshooting
Verify that the device is using the right power cord/adapter (DC 48V); please do not use a power adapter with DC output higher than 48V, or the device may be damaged.
Select the proper UTP/STP cable to construct the user network. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections that depend on the connector type the switch equipped: 100R Category 3, 4 or 5 cable for 10Mbps connections, 100R Category 5 cable for 100Mbps connections, or 100R Category 5e/above cable for 1000Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters
(328 feet).
R = replacement letter for Ohm symbol.
Diagnosing LED Indicators: To assist in identifying problems, the switch can be easily monitored through panel indicators, which describe common problems the user may encounter, so the user can be guided towards possible solutions.
If the power indicator does not light on when the power cord is plugged in, you may have a problem with power cord. Check for loose power connections, power losses, or surges, at the power outlet. If you still cannot resolve the problem, contact a local dealer for assistance.
If the LED indicators are normal and the connected cables are correct but packets still cannot be transmitted, please check the user system's Ethernet device configuration or status.
134 EKI-9628G User Manual
www.advantech.com
Please verify specifications before quoting. This guide is intended for reference purposes only.
All product specifications are subject to change without notice.
No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permission of the publisher.
All brand and product names are trademarks or registered trademarks of their respective companies.
© Advantech Co., Ltd. 2007
advertisement
Related manuals
advertisement
Table of contents
- 15 Specifications
- 16 Hardware Views
- 16 Front View
- 17 Rear View
- 18 Dimensions
- 18 Packing List
- 20 Warnings
- 21 Installation Guidelines
- 22 Environment and Enclosure Guidelines
- 22 Connecting Hardware
- 22 Verifying Switch Operation
- 23 Installing the Switch
- 23 Rack-Mounting
- 23 Installing and Removing SFP Modules
- 24 Installing SFP Modules
- 25 Removing SFP Modules
- 26 Connecting the Switch to Ethernet Ports
- 26 RJ45 Ethernet Cable Wiring
- 27 Connecting the Switch to Console Port
- 28 Power Supply Installation
- 28 Overview
- 29 Considerations
- 29 Grounding the Device
- 30 Wiring a Relay Contact
- 31 Wiring the Power Inputs
- 32 Reset Button
- 34 First Time Setup
- 34 Overview
- 34 Introduction
- 34 Administrative Interface Access
- 35 Using the Graphical (Web) Interface
- 35 Configuring the Switch for Network Access
- 36 Configuring the Ethernet Ports
- 37 Command Line Interface Configuration
- 37 Introduction to Command-Line Interface (CLI)
- 37 Accessing the CLI
- 38 Web Browser Configuration
- 38 Preparing for Web Configuration
- 38 System Login
- 40 Log In
- 40 Recommended Practices
- 40 Changing Default Password
- 41 Monitoring
- 41 Device Information
- 42 Logging Message
- 43 Port Monitoring
- 44 Link Aggregation
- 45 LLDP Statistics
- 46 IGMP Statistics
- 48 System
- 48 IP Settings
- 48 IPv6 Settings
- 49 System Time
- 50 Network Port
- 51 L2 Switching
- 51 Port Configuration
- 52 Port Mirror
- 53 Link Aggregation
- 56 802.1Q VLAN
- 59 Q-in-Q
- 62 802.3az EEE
- 63 Multicast
- 67 Jumbo Frame
- 68 4.5.10 Spanning Tree
- 73 4.5.11 X-Ring Elite
- 74 4.5.12 X-Ring Pro
- 75 4.5.13 Loopback Detection
- 77 RL3 Switching
- 77 SNAT (Source NAT)
- 78 DNAT (Destination NAT)
- 79 Routing
- 79 MAC Address Table
- 79 Static MAC
- 80 MAC Aging Time
- 80 Dynamic Forwarding Table
- 81 Security
- 81 Storm Control
- 83 Port Security
- 83 Protected Ports
- 84 DoS Prevention
- 86 Applications
- 88 802.1x
- 89 IP Security
- 90 General
- 96 QoS Basic Mode
- 97 Rate Limit
- 99 Management
- 99 4.10.1 LLDP
- 102 4.10.2 SNMP
- 104 4.10.3 TCP Modbus Settings
- 105 4.10.4 DHCP Server
- 110 4.10.5 SMTP Client
- 113 4.10.6 RMON
- 116 Diagnostics
- 116 4.11.1 Cable Diagnostics
- 117 4.11.2 Ping Test
- 118 4.11.3 IPv6 Ping Test
- 119 4.11.4 System Log
- 121 4.11.5 DDM
- 122 4.11.6 LED Indication
- 123 Tools
- 123 4.12.1 Backup Manager
- 124 4.12.2 Upgrade Manager
- 124 4.12.3 Dual Image
- 125 4.12.4 Save Configuration
- 125 4.12.5 User Account
- 126 4.12.6 Reset System
- 126 4.12.7 Reboot Device
- 126 Modbus/TCP Mapping
- 126 4.13.1 Modbus/TCP Mapping Table
- 147 Troubleshooting