Below you will find brief information for EVM002 Series (NA) EVC/48A/LVL2/C2/OR. This user manual provides essential instructions for the safe installation, operation, and maintenance of the Electric Vehicle AC Charger. It covers topics such as safety precautions, product specifications, mounting procedures, wiring the circuit, understanding light codes, and warranty information. The charger supports SAE J1772 Type 1 connector, offers ground fault detection, and includes multiple protection features.
Advertisement
Advertisement
Electric Vehicle AC Charger EVC/48A/LVL2/C2/OR- User Manual 说明书 技术要求: 1.成品规格: 142 x 210 mm; 2.印刷方式: 单面印刷 ; 双面印刷; 3.装订方式: 骑马钉; 单面对折; 4.材质: 70g双胶纸; 108g铜板纸; 5.印刷颜色: 单黑色; 6.有条码的话,刷码等级需达到B级; 7.检验工具:卷尺,尺寸单位均为mm 线条图提供者 设计者 排版者 审核者 庄妍妍 EVM002 Series (NA) 2024.09.18 批准者 文件翻译者 1:1 版本号 修订原因 修订人 修订日期 签名 日期 签名 Electric Vehicle AC Charger EVC/48A/LVL2/C2/OR - User Manual Version 1 USER MANUAL USER MANUAL TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS ................................... 1 2. PRODUCT INTRODUCTIONS................................................... 5 3. VERIFY CONTENTS.................................................................. 8 4. GATHER TOOLS ....................................................................... 9 5. PLAN THE MOUNTING ........................................................... 10 6. WALL MOUNTING................................................................... 11 7. WIRE THE CIRCUIT ................................................................ 14 8. LIGHT CODES ......................................................................... 18 9. FCC DECLARATION ............................................................... 20 10. WARRANTY AND MAINTENANCE....................................... 21 USER MANUAL USER MANUAL WARNING & CAUTION WARNING & CAUTION 1. Important Safety Instructions 1.2 Installation Requirements 1.1 Overall Warnings & Cautions WARNING: Disconnect electrical power prior to installing the charging station. WARNING: To avoid fire, injury or death, carefully read and follow the instructions during WARNING: Be sure to preview the user manual and ensure local building and electrical codes installation, operation and maintenance. are reviewed before installing the AC charger. - DO NOT put fingers into the electric vehicle connector. WARNING: The AC charger should be installed by a qualified technician according to the user - DO NOT use this product if the flexible power cord or EV cable is frayed, insulation-broken, manual and local safety regulations. or any other signs of damage. CAUTION: Use appropriate protection when connecting to the main power distribution cable. - DO NOT use this product if the enclosure or the EV connector is broken, cracked, open, or CAUTION: Type B, C or D breaker with the rating current for table should be installed in the shows any other indication of damage. upstream AC distribution box. - DO NOT remove cover or attempt to open the enclosure because of risk of electric shock. CAUTION: The device shall be mounted at height between 2 feet and 4 feet from ground. WARNING: This device should be supervised when used around children. CAUTION: Please keep the charger in a clean area with low humidity. Not recommended to WARNING: This device must be grounded. be installed in coastal environments with high humidity or high dust. WARNING: To avoid a risk of fire or electric shock, do not use this device with an extension 1.3 Daily Maintenance cord. CAUTION: Avoid moisture or water in the charger. If there is water or moisture ingress in the WARNING: The suitability of the use of flexible cord in accordance with CE code, part I, rule charger, it is necessary to immediately power off to avoid immediate danger, and notify the 4-012, is to be determined by the local inspection authority. professionals to carry out maintenance before next use. WARNING: To reduce the risk of fire, connect only to a circuit provided branch circuit CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If it is over-current protection in accordance with the CSA C22.1–15 Canadian Electrical Code, Part damaged, please contact a professional technician. 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 CAUTION: Avoid placing the charger near hot objects and at high temperature locations and National Electrical Code (USA). away from dangerous substances such as flammable gases and corrosive materials. CAUTION: Do not put heavy objects on the charger to avoid danger. Circuit Breaker Options table 1 Output Amperage (A) 16A 32A 40A 48A 70A 80A Circuit Breaker Options (A) 20A 40A 50A 60A 90A 100A 2 USER MANUAL USER MANUAL WARNING & CAUTION WARNING & CAUTION Consignes De Sécurité Importantes 1.2 Exigence Avant L’installation 1.1 Avertissement & Mise En Garde Généraux AVERTISSEMENT : Assurez-vous de consulter le manuel d'utilisation et assurez-vousque les AVERTISSEMENT : Pour éviter les risques d’incendie, de blessure ou de mort, il faut lire et codes locaux du bâtiment et de l'électricité sont passés en revue avant d'installer le chargeur. suivre soigneusement les instructions pendant l’installation, l’utilisation et l’entretien. AVERTISSEMENT : Débranchez l'alimentation électrique avant d'installer la station decharge. - Ne mettez pas les doigts dans le connecteur du véhicule électrique. AVERTISSEMENT : Le chargeur CA doit être installé par un technicien qualifié conformément au - N'utilisez pas ce produit si le cordon d'alimentation flexible ou le câble EV est effiloché, manuel d'utilisation et aux réglementations de sécurité locales. isolé ou présentant tout autre signe de dommage. MISE EN GARDE : Utilisez une protection appropriée lors de la connexion au câble de distribu- - N'utilisez pas ce produit si le boîtier ou le connecteur EV est cassé, fissuré, ouvert ou tion d'alimentation principal. montre toute autre indication de dommage. MISE EN GARDE : Un disjoncteur de type B, C ou D avec le courant nominal indiqué dans le Ne retirez pas le couvercle et n'essayez pas d'ouvrir le boîtier en raison du risque de choc électrique. tableau doit être installé dans le boîtier de distribution CA en amont. MISE EN GARDE : Cet appareil doit être monté à une hauteur entre 2 feet and 4 feet du sol. AVERTISSEMENT : Cet appareil doit être surveillé lorsqu'il est utilisé à proximité d'enfants. AVERTISSEMENT : Cet appareil doit être mis à la terre. AVERTISSEMENT : Pour éviter tout risque d'incendie ou de choc électrique, n'utilisez pas cet appareil avec une rallonge électrique. AVERTISSEMENT : L'adéquation de l'utilisation du cordon flexible conformément au code ce, partie i, règle 4-012, doit être déterminée par l'autorité d'inspection locale compétente. MISE EN GARDE : Veuillez conserver le chargeur dans un endroit propre et peu humide. Il n’est pas recommandé de l'installer dans des environnements côtiers à forte humidité ou à forte poussière. 1.3 Entretien Quotidien MISE EN GARDE : Évitez l'humidité ou l'eau dans le chargeur. En cas d'infiltration d'eau ou d'humidité dans le chargeur, il est nécessaire de l'éteindre immédiatement pour éviter tout danger AVERTISSEMENT : Pour réduire les risques d'incendie, ne connecter qu'à un circuit immédiat et d'avertir le personnel professionnel d'effectuer l'entretien avant la prochaine utilisation. protection contre les surintensités des circuits de dérivation conformément à la norme canadienne CSA C22.1-15 Code électrique, partie 1 (Canada) ou NOM-001-SEDE Installa- MISE EN GARDE : Veuillez utiliser le chargeur correctement. Ne frappez pas ou n'appuyez pas trop fort sur le boîtier. Si le boîtier est endommagé, veuillez contacter un technicien professionnel. tions électriqu (Mexique) ou ANSI / NFPA 70 National Electrical Code (États-Unis). MISE EN GARDE : Évitez de placer le chargeur à proximité d'objets chauds et à des endroits à Circuit Breaker Options table 3 haute température et loin de substances dangereuses telles que des gaz inflammables et des Output Amperage (A) 16A 32A 40A 48A 70A 80A matériaux corrosifs. Circuit Breaker Options (A) 20A 40A 50A 60A 90A 100A MISE EN GARDE : Ne placez pas d'objets lourds sur le chargeur pour éviter tout danger. 4 USER MANUAL USER MANUAL 2. Product Introductions 2.2 Basic Dimensions CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. 9.61" 4.64" 2.1 Basic Interface LED Light Indication Emergency Button 15.83" RFID Swipe Area SAE J1772 AC Charging Connector Rear Notch Charging Cable Inlet 2.83" Rear AC Power Inlet 4.8" AC Power Inlet LAN Cable Inlet 5 6 USER MANUAL USER MANUAL 3. Verify Contents 2.3 Specifications EVC/48A/LVL2/C2/OR Ensure you have this installation guide and these parts: POWER 208~240V AC Input Rating Output Current&Power Power Wiring 19.2 kW (80A) 11.5 kW (48A) Input Cord Hard-wire Mains frequency 50 / 60 Hz Connector Type SAE J1772 Type1 18ft / SAE J3400 NACS 18ft (Optional) Ground Fault Detection Protection Meter Accuracy Electric Vehicle AC Charger EVM002 Series (NA) -User Manual L1 / L2 / GND CCID 20 UVP, OVP, RCD (CCID 20), SPD, Ground Fault Protection, OCP, OTP, Control Pilot Fault Protection ±1% (CTEP qualified) AC Charger ×1 User Manual ×1 Wall-Mounted Bracket ×1 M4 Anti-Theft Screws ×1 M6 Hexagonal Expansion Screws ×4 Allen Wrench ×1 Mounting Template ×1 RFID Card ×2 Cable Ramp ×1 ST3.5*16 Screws ×2 AD34.5 Conduit Fitting ×1 AD21.2 Conduit Fitting ×1 M32 Conduit Fitting ×1 M4 Anti-Theft Round Head Screws ×4 (Spare) USER INTERFACE Status Indication Screen Language User Interface Connectivity Communication Protocols User Authentication Card Reader Software Update English / Spanish / French Compatible with multiple CPOs Bluetooth5.2, Wi-Fi (2.4G / 5G), Ethernet OCPP2.0.1 / OCPP 1.6Js self-adaptation ISO15118-2/3 Dynamic Load Balancing Plug&Charge(Free)、Plug&Charge(PnC)、RFID Card、OCPP RFID, ISO14443A、ISO14443B, 13.56MHz OTA CERTIFICATION & STANDARDS Safety & Compliance Holster Bracket Pile Group Management LED indication 4.3' touch screen (UI upgradable) UL991, UL1998, UL2231, UL2594, ISO15118 (P&C) Certification ETL / FCC / Energy Star Warranty 36 months GENERAL Button Emergency Button Enclosure Rating NEMA 4 (IP65), IK08 Operating Altitude <6561ft (2000m) Operating Temperature -40°F ~ +131°F (-40°C ~ +55°C) Storage Temperature -40°F ~ +185°F (-40°C ~ +85°C) Operating Humidity Mounting Product Dimensions 7 5 ~ 95% Wall mount / Pedestal (optional) 15.83"×9.61"×4.64" (402×244×118mm) 8 USER MANUAL USER MANUAL 5. Plan The Mounting 4. Gather Tools Tools required before installing the Wall-Mounted charger, gather the following tools: 1. Wire stripper WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the 2. Adjustable Wrench breaker and bus bar, are clean and tight. 3. Voltmeter or digital multi-meter (for measuring AC voltage at the installation site) 4. Level CAUTION: Not recommended to be installed in coastal environments with high 5. Pencil or marker humidity or high dust. 6. Drill 7. Phillips screwdriver Select the appropriate mounting location with electri calcapacity: I. Ensure the owner has chosen a mounting location that allows the charging cable to reach the car’s charging port while still providing slack. 1 4 2 5 3 6 II. The device must be anchored into mounting such as 3.14" x 5.11" stud or a solid wall. 7 Note: The above tools are very important, please gather them all. 9 10 USER MANUAL USER MANUAL 6. Wall mounting STEP 3 STEP 1 Use 4 Hexagonal Expansion Screws to secure the wall-mounted bracket on the wall, Use an Make sure the installation wall is vertical, and use the Mounting template to drill four screw holes wrench to tighten the screw nuts on the expansion screws. with a diameter of 0.33" (8.5mm) and a depth of 2.17"~2.36" (55mm~60mm) at a height of 47.24"~51.18"(1200-1300mm) from the ground according to the hole positions. Wall-Mounted Bracket 47.24"~51.18" (1200-1300mm) Ground STEP 2 Push the bracket down to remove the wall hanger. STEP 4 Align the rear notch of charger with the wall-mounted bracket and alignment the screw holes at the bottom, and secure it using M4 Anti-Theft Round Head Screws. 11 12 USER MANUAL USER MANUAL 7. Wire The Circuit STEP 5 Overall outlook picture after installation: WARNING: This device must be grounded. Disconnect electrical power prior to installing the charging station. Wall-mounted cable winding Plug holder (optional) Pedestal (optional) WARNING: Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or serviceman if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product – if it doesn’t fit the outlet, have a proper outlet installed by a qualified electrician. CAUTION: Use appropriate protection when connecting to the main power distribution cable. This step is only to Hard-wire wiring and requires user-supplied AC input cables. For safe use of electricity, please set circuit breaker protection in the input part of EV Charger. Circuit Breaker Options table 13 Output Amperage (A) 16A 32A 40A 48A 70A 80A Circuit Breaker Options (A) 20A 40A 50A 60A 90A 100A 14 USER MANUAL USER MANUAL STEP 1 STEP 4 Use a allen wrench to loosen the two screws Take out the AC input cable and strip the TPU located at the bottom of the charging station. cover by 5.52" (140mm), and then strip individual Open the buckle on both sides and lift up the wires by 0.47" (12mm). use ferrules on stranded front cover to remove it from the charging wires and press it by wire crimper. station. Note: You need to bring your own ferrules. (ferrules) 0.47"(12mm) 5.52"(140mm) STEP 2 Remove the cover from the charger using the appropriate tools. (such as coin) STEP 5 COCN First, pass the AC input cable through the M32 STEP 3 Conduit Fitting Part 3 ( 3 ), then continue through Part Remove the waterproof plug from the charger 1 and Part 2. Connect the wires (L1, L2, GND) and cable inlet,Connect and Lock the M32 Conduit tighten each connector screw to 2 N.m (17.7 in.lbs). L1 L2 GND Fitting Part1 ( 1 ) and Part2 ( 2 ) (including the L1 L2 GND washer) to the Inlet as shown below. Note: L1 L2 GND 1.You need to bring your own AC input cable. 2.Select the AD34.5 or M32 Conduit Fitting based 1 L1 L2 GND 3 1 2 on the AC input cable type,If you use AD34.5 Conduit Fitting, perform the same steps as above. 15 3 2 16 USER MANUAL USER MANUAL STEP 6 STEP 8 Lock the M32 Conduit Fitting Part 3 ( 3 ), Align the cover with its position on the Press the AC input cable with cable ramp and charging station.Secure the cover in place secure it with two screws (3.5*16). using the appropriate tools (such as coin). L1 L2 GND COCN L1 L2 GND STEP 9 3 Align the magnetic positions of the cover plate and the middle frame, Fasten both clips and fix the two screws at the bottom. STEP 7 8. Light Codes Remove the waterproof plug from the charger cable inlet. Connect and lock the 8.1 After Start UP AD21.2 conduit fitting Part1 ( 1 ) and Part2 ( 2 ) to the inlet. Then, insert the Ethernet cable with the RJ45 plug into the bellows, L1 L2 GND 1 through the AD21.2 conduit fitting, and plug L1 L2 GND 1 2 the cable into the RJ45 port (RS232/RS485 operate in the same mode). Note: You need to bring your own bellows 17 2 Device Status Light Codes Power On Blue, green and red run clockwise Standby Solid Blue Plug The Charging Connector Solid Green Swipe Card Green Blinking Charging In Progress Green Breathing Finished / Stopped Charging Solid Green OTA Yellow Breathing Fault Red 18 USER MANUAL USER MANUAL 9. FCC Declaration 8.2 Error and Warning Messages This device complies with part 15 of the FCC Rules. No. Fault Status Red Light Remark 1 Emergency Fault Solid Red Reset Recover 2 Meter Fault 1 flash followed by 3 sec pause Auto Recover 3 CP Fault 2 flashes followed by 3 sec pause Unplug the Connector to Recover 4 UVP 3 flashes followed by 3 sec pause Auto Recover 5 OVP 4 flashes followed by 3 sec pause Auto Recover 6 OTP 5 flashes followed by 3 sec pause Auto Recover 7 OCP 6 flashes followed by 3 sec pause Unplug the Connector to Recover Note: This equipment has been tested and found to comply with the limits for a Class A digital 8 Ground Fault 7 flashes followed by 3 sec pause Unplug the Connector to Recover device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 9 Relay Fault 8 flashes followed by 3 sec pause Unplug the Connector to Recover protection against harmful interference when the equipment is operated in a commercial 10 RCD Abnormal 9 flashes followed by 3 sec pause Unplug the Connector to Recover 11 RCD Self-Test Fault 10 flashes followed by 3 sec pause Reboot to Recover 12 Relay Self-Test Fault 11 flashes followed by 3 sec pause Reboot to Recover Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WIFI module: Containing FCC ID: XMR2023FCS960K To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. 19 20 USER MANUAL 10. Warranty and Maintenance • The warranty period for this charger is three years. • During the warranty period for any malfunction under normal use according to the User Manual (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms: 1. The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product. 2. Those who are unable to provide valid proof of purchase. 3. Those who exceed the manufacturer's specified warranty period. 4. Those who damage the product due to not following the product service instruction for use, maintenance and storage. 5. Damage or malfunction caused by external object entering. 6. Unauthorized repair, disassembly or modification. 7. Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.). 8. Malfunction and damage caused by other unavoidable external factors. Malfunction and damage caused by improper use of equipment, such as water or other solutions entering into the equipment. 9. Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment. The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reasonableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages. 21 ">
Download
Advertisement
Key features
Supports SAE J1772 Type 1 connector
Offers ground fault detection and protection
Provides over-current and over-temperature protection
Features RFID card authentication
Includes Ethernet and Wi-Fi connectivity
Complies with UL991, UL1998, UL2231, and UL2594 safety standards
NEMA 4 (IP65) enclosure rating for environmental protection
Frequently asked questions
A Type B, C, or D breaker with the rating current for the table should be installed in the upstream AC distribution box.
The device shall be mounted at a height between 2 feet and 4 feet from the ground.
Immediately power off to avoid immediate danger, and notify professionals to carry out maintenance before next use.