Leviton EV48SDP Series Electric Vehicle AC Charger User Manual
Below you will find brief information for Electric Vehicle AC Charger EV48SDP Series (NA). This user manual provides essential safety instructions, installation guidance, and daily maintenance tips for your EV charger. Learn about the product's interfaces, dimensions, technical specifications, and how to perform wall mounting. The manual includes wiring instructions, light codes for status indication, FCC declaration, and warranty details.
Advertisement
Advertisement
Electric Vehicle AC Charger EV48SDP Series (NA) - User Manual 说明书 技术要求: 1.成品规格: 142 x 210 mm; 2.印刷方式: 单面印刷 ; 双面印刷; 3.装订方式: 骑马钉; 单面对折; 4.材质: 70g双胶纸; 108g铜板纸; 5.印刷颜色: 单黑色; 6.有条码的话,刷码等级需达到B级; 7.检验工具:卷尺,尺寸单位均为mm 线条图提供者 设计者 排版者 审核者 庄妍妍 EV48SDP Series (NA) 2024.09.19 批准者 文件翻译者 1:1 版本号 修订原因 修订人 修订日期 签名 日期 签名 Electric Vehicle AC Charger EV48SDP Series (NA) - User Manual Version 1 USER MANUAL USER MANUAL TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS ................................... 1 2. PRODUCT INTRODUCTION ..................................................... 5 3. INSTALLATION PREPARATION ............................................... 8 4. WALL MOUNTING................................................................... 10 5. WIRE THE CIRCUIT AND INSTALL........................................ 12 6. LIGHT CODES ......................................................................... 20 7. FCC DECLARATION ............................................................... 21 8. WARRANTY AND MAINTENANCE......................................... 22 USER MANUAL USER MANUAL 1. Important Safety Instructions 1.2 Installation Requirements 1.1 Overall Warnings & Cautions WARNING: Disconnect electrical power prior to installing the charging station. Read and follow all warnings and instructions before installing and operating the product. WARNING: Be sure to preview the user manual and ensure local building and electrical codes WARNING: To avoid fire, injury or death, carefully read and follow the instructions during are reviewed before installing the DC charger. installation, operation and maintenance. WARNING: The AC charger should be installed by a qualified technician according to the user - DO NOT put fingers into the electric vehicle connector. manual and local safety regulations. - DO NOT use this product if the flexible power cord or EV cable is frayed, insulation-broken, CAUTION: Use appropriate protection when connecting to the main power distribution cable. or any other signs of damage. CAUTION: Type B, C or D breaker with the rating current for table should be installed in the - DO NOT remove cover or attempt to open the enclosure because of risk of electric shock. upstream AC distribution box. - DO NOT install the product near flammable, explosive, or combustible materials. CAUTION: The device shall be mounted at height between 2 feet and 4 feet from ground. WARNING: The product should be supervised when used around children. CAUTION: Please keep the charger in a clean area with low humidity. Not recommended to be WARNING: The product must be grounded. installed in coastal environments with high humidity or high dust. WARNING: To avoid a risk of fire or electric shock, do not use this device with an extension cord. 1.3 Daily Maintenance WARNING: To reduce the risk of fire, connect only to a circuit provided branch circuit over-current protection in accordance with the CSA C22.1–15 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code (USA). CAUTION: Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger, and notify the professionals to carry out maintenance before next use. CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If it is damaged, please contact a professional technician. Circuit Breaker Options table Output Amperage (A) 1 CAUTION: Avoid placing the charger near hot objects and at high temperature locations and 32A*2 40A*2 48A*2 Circuit Breaker Options (A) Method 1 40A*2 50A*2 60A*2 Circuit Breaker Options (A) Method 2 80A 100A 120A away from dangerous substances such as flammable gases and corrosive materials. CAUTION: Do not put heavy objects on the charger to avoid danger. 2 USER MANUAL USER MANUAL 1. Consignes De Sécurité Importantes 1.2 Exigence Avant L’installation 1.1 Avertissement & Mise En Garde Généraux AVERTISSEMENT : Assurez-vous de consulter le manuel d'utilisation et assurez-vousque les AVERTISSEMENT : Pour éviter les risques d’incendie, de blessure ou de mort, il faut lire et codes locaux du bâtiment et de l'électricité sont passés en revue avant d'installer le chargeur. suivre soigneusement les instructions pendant l’installation, l’utilisation et l’entretien. - Ne mettez pas les doigts dans le connecteur du véhicule électrique. - N'utilisez pas ce produit si le cordon d'alimentation flexible ou le câble EV est effiloché, isolé ou présentant tout autre signe de dommage. AVERTISSEMENT : Débranchez l'alimentation électrique avant d'installer la station decharge. AVERTISSEMENT : Le chargeur CA doit être installé par un technicien qualifié conformément au manuel d'utilisation et aux réglementations de sécurité locales. - N'utilisez pas ce produit si le boîtier ou le connecteur EV est cassé, fissuré, ouvert ou MISE EN GARDE : Utilisez une protection appropriée lors de la connexion au câble de distribu- montre toute autre indication de dommage. tion d'alimentation principal. Ne retirez pas le couvercle et n'essayez pas d'ouvrir le boîtier en raison du risque de choc MISE EN GARDE : Un disjoncteur de type B, C ou D avec le courant nominal indiqué dans le électrique. tableau doit être installé dans le boîtier de distribution CA en amont. AVERTISSEMENT : Cet appareil doit être surveillé lorsqu'il est utilisé à proximité d'enfants. AVERTISSEMENT : Cet appareil doit être mis à la terre. AVERTISSEMENT : Pour éviter tout risque d'incendie ou de choc électrique, n'utilisez pas MISE EN GARDE : Cet appareil doit être monté à une hauteur entre 2 feet and 4 feet du sol. MISE EN GARDE : Veuillez conserver le chargeur dans un endroit propre et peu humide. Il n’est pas recommandé de l'installer dans des environnements côtiers à forte humidité ou à forte cet appareil avec une rallonge électrique. AVERTISSEMENT : L'adéquation de l'utilisation du cordon flexible conformément au code poussière. ce, partie i, règle 4-012, doit être déterminée par l'autorité d'inspection locale compétente. 1.3 Entretien Quotidien AVERTISSEMENT : Pour réduire les risques d'incendie, ne connecter qu'à un circuit protection contre les surintensités des circuits de dérivation conformément à la norme canadienne CSA C22.1-15 Code électrique, partie 1 (Canada) ou NOM-001-SEDE Installations électriqu (Mexique) ou ANSI / NFPA 70 National Electrical Code (États-Unis). MISE EN GARDE : Évitez l'humidité ou l'eau dans le chargeur. En cas d'infiltration d'eau ou d'humidité dans le chargeur, il est nécessaire de l'éteindre immédiatement pour éviter tout danger immédiat et d'avertir le personnel professionnel d'effectuer l'entretien avant la prochaine utilisation. MISE EN GARDE : Veuillez utiliser le chargeur correctement. Ne frappez pas ou n'appuyez pas trop fort sur le boîtier. Si le boîtier est endommagé, veuillez contacter un technicien professionnel. Circuit Breaker Options table Output Amperage (A) 32A*2 40A*2 48A*2 Circuit Breaker Options (A) Method 1 40A*2 50A*2 60A*2 Circuit Breaker Options (A) Method 2 80A 100A 120A MISE EN GARDE : Évitez de placer le chargeur à proximité d'objets chauds et à des endroits à haute température et loin de substances dangereuses telles que des gaz inflammables et des matériaux corrosifs. MISE EN GARDE : Ne placez pas d'objets lourds sur le chargeur pour éviter tout danger. 3 4 USER MANUAL USER MANUAL 2. Product Introduction CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. 2.1 Basic Interface 2.2 Basic Dimensions Enclosure 4.8" 12.2" 4G SIM Card Solt Light Bar 78 78 90 1 23 90 1 23 RS485 Port (connects the RS485 cables) 4.8" 19.2" 4 56 Card Swipe Area RJ45 Port (connects the RJ45 cables) 4 56 7" LCD Touch Screen Reset CAN Port (connects the CAN cables) Current Selector (adjusts the current for the charger) Wall-Mounted Bracket 2.8" 4.8" AC Power Cord Interface (Bottom Connect) Ethernet Inlet Hole AC Power Cord Interface (Rear Connect) Dual Charging Cable Interface 5 6 USER MANUAL USER MANUAL 3. Installation Preparation 2.3 Technical specifications 3.1 Verify contents EV48SDP POWER Input Rating 208~240V AC Output Current 48A*2 Network Type L1 / L2 / GND Input Cord 50 / 60 Hz Connector Type SAE J1772 Type1 18ft / SAE J3400 NACS 18ft (Optional) Protection Meter Accuracy CCID 20 ±1% (CTEP qualified) Status Indication LED indication Screen 7" touch screen English / Spanish / French User Interface Compatible with multiple CPOs Connectivity Bluetooth5.2, Wi-Fi 6 (2.4G / 5G), Ethernet Communication Protocols Pile Group Management User Authentication Card Reader Software Update OTA 7 0:8A; 1:16A; 2:24A; 3:32A; 4:40A; 5:48A; NEMA 4 (IP65), IK08 Cable Ramp ×1 ST3.5*16 Screws ×2 RFID Card ×2 Shorting Terminal Combination (2pcs) ×1 Mounting template ×1 RNB Terminal ×6 AD21.2 Conduit Fitting ×1 AD42.5 Conduit Fitting ×1 M40 Conduit Fitting ×1 Holster Bracket (Optional) ×2 Plug Holster M5*16mm Screws (Optional) ×2 Holster Bracket Screws (Optional) ×8 Plug Holster (Optional) ×2 <6561ft (2000m) Operating Temperature −40°F ~ +131°F (−40°C ~ +55°C) Storage Temperature −40°F ~ +185°F (−40°C ~ +85°C) Product Dimensions Allen Wrench ×1 UL991, UL1998, UL2231, UL2594, ISO15118 (PnC) 36 months Mounting M6 Hexagonal Expansion Screws ×4 ISO 14443 A/B, ISO / IEC 15693, VAS & Apple, Pay & Google, Pay & More (Optional) GENERAL Operating Humidity M4 Anti-Theft Screws ×2 Plug&Charge (Free) / RFID Card / Credit Card (Optional) ETL / FCC / Energy Star Operating Altitude Wall-Mounted Bracket ×1 ISO15118-2/3 (Optional) Warranty Enclosure Rating User Manual ×1 Dynamic Load Balancing Certification Dip Switch AC Charger ×1 OCPP2.0.1 / OCPP 1.6Js self-adaptation CERTIFICATION & STANDARDS Safety & Compliance EV48SDP Series (NA) -User Manual UVP, OVP, RCD (CCID 20), SPD, Ground Fault Protection, OCP, OTP, Control Pilot Fault Protection USER INTERFACE Language Electric Vehicle AC Charger Hard-wire Mains frequency Ground Fault Detection Check the box to ensure you have the user manual, and these parts: 5~95% Wall mount / Pedestal (optional) 12.2"×19.2"×4.8” (310×488×122mm) 8 USER MANUAL USER MANUAL 4. Wall mounting 3.2 Gather Tools In addition, you will need the following tools and accessories: WARNING: This device must be grounded. Disconnect electrical power prior to 1. Level installing the charging station. 2. Drill 3. Gummi hammer STEP 1 4. Phillips screwdriver 5. Wire stripper Make sure the installation wall is vertical, and use the Mounting template to drill four screw holes 6. Voltmeter or digital multi-meter with a diameter of 0.33" (8.5mm) and a depth of 2.17"~2.36" (55mm~60mm) at a height of (for measuring AC voltage at the installation site) 47.24"~51.18" (1200-1300mm) from the ground according to the hole positions. Please drill screw holes in the direction of the template arrow. Use Gummi hammer to fix the expansion screws into the holes. 1 9 5 3 6 47.24"~51.18" (1200-1300mm) 4 2 UP Wall mounting use the mounting layout template provided to drill the holes 1.Tape the layout template on the wall to the position where you plan to install the charger. 2.Mark the mounting holes (which are marked as circles on the template ) on to the wall. 3.Remove the template. 4.Drill the 4 mounting holes of size φ10 and a depth of 50~55mm. WARNING: If you hit something metallic when drilling, stop immediately and contact an electrician. Ground 10 USER MANUAL USER MANUAL STEP 2 1. Remove the 2 M4 Anti-theft screws from backplate by allen wrench. 3. Align the rear notch of charger with the wall-mounted bracket and alignment the screw holes at the bottom, and secure it using M4 Anti-Theft Screws. 2. Use 4 Hexagonal Expansion Screws to secure the wall-mounted bracket on the wall, Use an wrench to tighten the screw nuts on the expansion screws. 5. Wire The Circuit STEP 1 Use a allen wrench to loosen the two screws located at the bottom of the charging station. Open the buckle on both sides and lift up the front cover to remove it from the charging station. 11 12 USER MANUAL USER MANUAL STEP 2 STEP 4 Remove the cover from the charger using We support two methods of AC Power input, the two methods of wiring will be different, the appropriate tools. (such as coin) respectively, as follows: Method 1: Two AC Power Cord and two Charging Cable Method 2: One AC Power Cord and two Charging Cable (Using shorting terminals to connect AC1_L1 and AC2_L1, connect AC1_L2 and AC2_L2) COCN STEP 3 L1 L2 GND L1 L2 GND L1 L2 L1 L2 GND L1 L2 GND L1 L2 GND L1 L2 L1 L2 GND Remove the waterproof plug from the charger cable inlet,Connect and Lock the M40 Conduit Fitting Part1 ( 1 ) and Part2 ( 2 ) (including the washer) to the Inlet as shown below. Method 1 Note: Method 1: Two AC Power Cord 1.You need to bring your own AC input cable. 2.Select the AD42.5 or M40 Conduit Fitting Circuit Breaker Options table based on the AC input cable type If you choose One AC Power Cord,you can use M40 or AD42.5 Conduit Fitting If you choose Two AC Power Cord,you only use AD42.5 Conduit Fitting 3.If you use AD42.5 Conduit Fitting,perform the same steps as above,and you need to bring Method 2 1 L1 L2 GND Output Amperage (A) 32A*2 40A*2 48A*2 Circuit Breaker Options (A) 40A*2 50A*2 60A*2 L1 L2 GND 1 STEP 4-1 2 3 Press the wires of AC power cord onto the RNB 2 terminals in the accessory kit. L1 L2 GND GND L1 L2 your own bellows. 13 14 USER MANUAL USER MANUAL STEP 4-2 STEP 4-2 First, pass the two AC power cords through the M40 Conduit Fitting Part 3 ( 3 ), then continue Take out the shorting terminals in the accessory package. Connect AC1_L1 and AC2_L1, and through Part 1 and Part 2. Connect the five terminals according to the following wiring methods connect AC1_L2 and AC2_L2 according to thefollowing wiring methods image. image, and connect the two GND together. L1 L1 L2 GND L1 L2 GND L1 L2 L2 L1 L2 GND L1 L2 GND L1 L2 L1 L2 GND L1 L2 GND L1 L2 GND L1 L2 L1 L2 GND 3 Method 2: One AC Power Cord STEP 4-3 Circuit Breaker Options table First, pass the One AC power cords through the M40 Conduit Fitting Part 3 ( 3 ), then continue Output Amperage (A) 32A*2 40A*2 48A*2 Circuit Breaker Options (A) 80A 100A 120A through Part 1 and Part 2. Connect the three terminals according to the following wiring methods L1 is connected to L1, L2 is connected to L2, and GND is connected to GND. STEP 4-1 L1 Press the wires of AC power cord onto the RNB terminals in the accessory kit. L1 L2 GND L1 L2 L1 L2 GND L1 L2 L2 GND L1 L2 L1 L2 GND GND 3 15 16 USER MANUAL USER MANUAL STEP 5 STEP 7 Lock the M40 Conduit Fitting Part 3 ( 3 ), Press the AC input cable with cable ramp and secure it This AC charger is equipped with two current selectors, each corresponding to the left and right with two screws (3.5*16). connectors, enabling it to support different maximum output currents via the setting rotary switch. Setting methods are shown below: Before setting the rotary switch, make sure the input power is turned OFF. Use a non-conductive object to set the rotary switch. L1 L2 GND L1 L2 GND L1 L2 L1 L2 GND 78 23 901 3 STEP 6 78 78 4 56 4 56 L2 23 90 1 23 L1 456 90 1 L1 L2 GND GND L1 L2 L1 L2 GND Remove the waterproof plug from the charger cable inlet. Connect and lock the AD21.2 conduit fitting Part1 ( 1 ) and Part2 ( 2 ) to the inlet. Then, insert the Ethernet cable with the RJ45 plug into the bellows, through the AD21.2 conduit fitting, and plug the cable into the RJ45 port (RS232/RS485 operate in the same mode). Note: You need to bring your own bellows. 78 78 2 3 4 5-9 Maximum Output Current 8A 16A 24A 32A 40A 48A 4 56 4 56 L2 1 23 1 L1 0 90 1 23 90 1 L1 L2 GND Switch Setting Number GND L1 L2 L1 L2 GND 1 2 2 17 18 USER MANUAL USER MANUAL 6. Light Codes STEP 8 6.1 After Start UP Align the cover with its position on the charging station.Secure the cover in place using the appropriate tools (such as coin). COCN STEP 9 Align the magnetic positions of the cover plate and the middle frame, Fasten both clips and fix the two screws at the bottom. 19 Device Status Light Codes Power On Blue, green and red run clockwise Standby Solid Blue Plug The Charging Connector Solid Green Authentication(Swipe Card) Green Blinking Charging In Progress Green Breathing Finished / Stopped Charging Solid Green Reservation Charging Solid Yellow Device Unabailable Yellow Blinking OTA Yellow Breathing Fault Red 6.2 Error and Warning Messages No. Fault Status Red Light Remark 1 Meter Fault 1 flash followed by 3 sec pause Auto Recover 2 CP Fault 2 flashes followed by 3 sec pause Unplug the Connector to Recover 3 UVP 3 flashes followed by 3 sec pause Auto Recover 4 OVP 4 flashes followed by 3 sec pause Auto Recover 5 OTP 5 flashes followed by 3 sec pause Auto Recover 6 OCP 6 flashes followed by 3 sec pause Unplug the Connector to Recover 7 Ground Fault 7 flashes followed by 3 sec pause Unplug the Connector to Recover 8 Relay Fault 8 flashes followed by 3 sec pause Unplug the Connector to Recover 9 RCD Abnormal 9 flashes followed by 3 sec pause Unplug the Connector to Recover 10 RCD Self-Test Fault 10 flashes followed by 3 sec pause Reboot to Recover 11 Relay Self-Test Fault 11 flashes followed by 3 sec pause Reboot to Recover 12 Sensor Fault 12 flashes followed by 3 sec pause Check sensor or contact after-sales 13 Cable Fault 13 flashes followed by 3 sec pause Check cable or contact after-sales 20 USER MANUAL USER MANUAL 7. FCC Declaration 8. Warranty and Maintenance This device complies with part 15 of the FCC Rules. • The warranty period for this charger is three years. • During the warranty period for any malfunction under normal use according to the User Manual Operation is subject to the following two conditions: (to be determined by certified maintenance technicians of sellers), the product shall be repaired This device may not cause harmful interference, and this device must accept any interference free of charge. Except for the following situations, the charger shall be subject to the above received, including interference that may cause undesired operation. warranty terms: 1. The warranty certificate cannot be provided or the contents of the warranty certificate are Caution: Changes or modifications to this unit not expressly approved by the party responsible modified for compliance could void the user's authority to operate the equipment. or inconsistent with the label indication of the repaired product. 2. Those who are unable to provide valid proof of purchase. Note: This equipment has been tested and found to comply with the limits for a Class A digital 3. Those who exceed the manufacturer's specified warranty period. device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 4. Those who damage the product due to not following the product service instruction for use, protection against harmful interference when the equipment is operated in a commercial maintenance and storage. environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 5. Damage or malfunction caused by external object entering. installed and used in accordance with the instruction manual, may cause harmful interference to 6. Unauthorized repair, disassembly or modification. radio communications. Operation of this equipment in a residential area is likely to cause harmful 7. Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, interference in which case the user will be required to correct the interference at his own expense. etc.). 8. Malfunction and damage caused by other unavoidable external factors. Malfunction and WIFI module: Containing FCC ID: XMR2023FCS960K damage caused by improper use of equipment, such as water or other solutions entering into the equipment. 9. Malfunction and damage caused by the grid power supply and voltage which is not specified for To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should use with the charger equipment. be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reasonableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages. 21 22 ">
Download
Advertisement
Key features
Dual charging cable interface
7" LCD touch screen
Multiple connectivity options
Dynamic Load Balancing
Wall-mountable design
Ground fault protection
Frequently asked questions
Power off immediately and notify professionals for maintenance.
No, do not use this device with an extension cord.
Use a Type B, C, or D breaker with the appropriate rating for your installation.