advertisement
ioLogik E1500 Series Introduction to the ioLogik E1500
Operating Temperature: -40 to 85°C (-40 to 185°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Altitude: Up to 2000 m
Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
Conformal Coating: Applies only to -CT models
Standards and Certifications
Safety: UL 508
EMI: EN 61000-3-2, EN 61000-3-3, EN 61000-6-4, FCC Part 15 Subpart B Class A
EMS: EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11,
EN 61000-6-2
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Rail Traffic: EN 50155, EN 50121-3-2, EN 50121-4
Green Product: RoHS, CRoHS, WEEE
Note: Please check Moxa’s website for the most up-to-date certification status.
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
ioLogik E1510-T
Inputs and Outputs
Digital Inputs: 12 channels (channel-to-channel isolation)
Isolation: 3K VDC or 2K Vrms
Digital Input
Sensor Type: Wet Contact (NPN or PNP), Dry Contact
I/O Mode: DI or Event Counter
Dry Contact:
• On: short to GND
• Off: open
Wet Contact (DI to GND):
• On: 0 to 3 VDC
• Off: 10 to 30 VDC
Counter Frequency: 250 Hz, power off storage
Digital Filtering Time Interval: Software selectable (minimum: 1 millisecond)
Power Requirements
Power Consumption: 163 mA @ 24 VDC
ioLogik E1512-T
Inputs and Outputs
Digital Inputs: 4 channels (channel-to-channel isolation)
Configurable DIOs: 4 channels
Isolation: 3K VDC or 2K Vrms
Digital Input
Sensor Type: Wet Contact (NPN or PNP), Dry Contact
I/O Mode: DI or Event Counter
Dry Contact:
• On: short to GND
• Off: open
1-4
ioLogik E1500 Series Introduction to the ioLogik E1500
Wet Contact (DI to GND):
• On: 0 to 3 VDC
• Off: 10 to 30 VDC
Common Type: 2 points per COM (Configurable DIOs)
Counter Frequency: 250 Hz, power off storage
Digital Filtering Time Interval: Software selectable (minimum: 1 millisecond)
Power Requirements
Power Consumption: 149 mA @ 24 VDC
Physical Dimensions
Unit = mm
1-5
advertisement
Related manuals
advertisement
Table of contents
- 6 Overview
- 6 Getting Started
- 6 Basic Configuration
- 6 Software Configuration
- 7 Common Specifications
- 8 ioLogik E1510-T
- 8 ioLogik E1512-T
- 10 Panel Guide
- 10 LED Indicators
- 11 Isolation DI (DI channels)
- 11 DI Circuit (DIO channels)
- 11 DO Circuit (DIO channels)
- 13 Connecting the Power
- 13 Grounding the ioLogik E1500
- 13 Connecting to the Network
- 14 I/O Wiring Diagrams
- 14 DI dry contact mode
- 14 DI wet contact mode (Ch-Ch isolation)
- 15 DI wet contact PNP/NPN mode (No CH-CH isolation)
- 15 DIO_DI wet contact mode (no CH-CH isolation)
- 16 DIO_DO sink mode
- 19 General Settings
- 20 Ethernet Configuration
- 21 Default Address
- 23 DI Channels
- 25 DO Channels
- 27 IP Accessibility
- 27 To allow access to a specific IP address
- 27 To allow access to hosts on a specific subnet
- 27 To allow unrestricted access
- 28 Network Connection
- 28 Firmware Update
- 28 Import System Configuration Settings
- 29 Export System Configuration Settings
- 29 Change Password
- 32 Main Screen Overview
- 33 System
- 34 Sort
- 34 Quick Links
- 35 Locate
- 35 Firmware Upgrade
- 35 Batch Upgrades on Multiple Devices of the Same Model
- 35 Unlock
- 36 Import
- 36 Export
- 37 Change IP Address
- 37 Batch TCP/IP Configuration of Multiple Devices
- 38 Restart System
- 38 Reset to Default
- 39 Mass Deployment (Import)
- 39 Mass Deployment (export)
- 41 Active OPC Server System Requirements
- 41 OLE for Process Control
- 42 Active OPC Server—From Pull to Push
- 44 One Simple Click Creates Active Tags
- 44 Faster, More Accurate Data Collection than Traditional “Pull Technology”
- 45 Installing Active OPC Server
- 45 Main Screen Overview
- 45 Menu Bar
- 45 File
- 46 System
- 47 Sort
- 47 Quick Links
- 49 Fixed & Dynamic Default addresses
- 49 0xxxx Read/Write Coils (Support function 1,5,15)
- 50 1xxxx Read only Coils (Support function 2)
- 51 3xxxx Read only Registers (Support function 4)
- 53 Fixed & Dynamic Default addresses
- 53 0xxxx Read/Write Coils (Support function 1,5,15)
- 54 1xxxx Read only Coils (Support function 2)
- 55 3xxxx Read only Registers (Support function 4)
- 55 4xxxx Read/Write Registers (Support function 3,6,16)