- Industrial & lab equipment
- Electrical equipment & supplies
- Power generators
- Simplicity
- 040516-00
- User manual
advertisement
20
C
D
A
B
Wireless Monitor
The generator is supplied with a battery-powered, wireless monitor.
The monitor communicates wirelessly with the generator control panel. The monitor may be placed in a suitable location in the home. The system has a line-of-sight range of about 200 feet, but this distance will decrease if the signal has to pass through walls or other objects.
The wireless monitor communicates with the generator, every 10 minutes and will display the status via a green or red LED light on the front of the monitor.
Compare the illustration below with your monitor to familiarize yourself with these important components.
• Generator Ready
• Generator Power
A - Green LED
B - Green LED
• Service Needed
• System Update with generator.
C - Red LED
D - Press for current system update
• Service code descriptions E - Name and number of flashes are listed on the backside of the wireless monitor.
• Battery Access Cover F - Record the dealer name and phone number on the label provided. Once removed, two non-rechargeable AA batteries are installed in the compartment G .
generator ready generator power service needed
# of flashes service needed
1 low battery voltage
2 low fluid level
3 under/over voltage
4 engine does not start
5 low frequency
6 engine overspeed
7 high temperature
8 transfer switch part #: 316196 fcc id: MCQ-XBS2C IC id: 1846A-XBS2C system update
Not for
Reproduction
DEALER NAME
DEALER PHONE
F
E
G
Wireless Monitor Operation
1. Remove battery access cover A on back of monitor and install 2 AA batteries. (Observe correct battery polarity which is embossed in the bottom of the battery compartment). Replace battery access cover.
service needed
# of flashes service needed
1 low battery voltage
2 low fluid level
3 under/over voltage
4 engine does not start
5 low frequency
6 engine overspeed
7 high temperature
8 transfer switch part #: 316196 fcc id: MCQ-XBS2C IC id: 1846A-XBS2C system update
4. “LINKING MODE” will scroll across the generator control panel.
5. Locate and hold the SYSTEM UPDATE button C on the wireless monitor while installing the batteries until all 3 LEDs turn on solid. All 3 LEDs will stay on solid until the monitor links to the generator. Once it links, the monitor will display the current state. The monitor will try to link for 1 minute. (This step can only be completed when the generator is in Linking Mode).
A generator ready
DEALER NAME
DEALER PHONE generator power
NOTICE The wireless monitor was linked to the generator at the factory. Communication will begin upon the installation of the batteries and the generator being placed in AUTO mode. You may need to press System Update one time.
C service needed system update
2. The wireless monitor does not have an on/off switch. When batteries are installed correctly, the GENERATOR READY green LED light will flash once every 7 seconds indicating the status of the generator.
B
B
NOTICE If communication does not begin upon placing the
6. Once the link has been confirmed, press the OK button on the generator control panel to exit or the generator in AUTO, installing batteries, and pressing System
Update, the monitor may need to be re-linked. To link, follow
Steps 3 through 6.
control board will automatically turn off linking after
5 minutes. The generator will now communicate with the wireless monitor.
3. Locate the MENU AND ESCAPE buttons on the control panel B . Press and hold for about 3 seconds to enter the linking mode.
Not for NOTICE It may take up to 1 minute for the monitor to begin displaying the generator status correctly.
DEALER PHONE
Reproduction menu
DEALER NAME ok esc
# of flashes service needed
1 low battery voltage
2 low fluid level
3 under/over voltage
4 engine does not start
5 low frequency
6 engine overspeed
7 high temperature
8 transfer switch part #: 316196 fcc id: MCQ-XBS2C IC id: 1846A-XBS2C auto off manual
21
Standard Operation:
Wireless Monitor Status LED’s
• The wireless monitor receives data from the generator every 10 minutes and displays the generator status through 3 LED’s.
• Pressing the SYSTEM UPDATE button will provide current generator status by flashing the status LED’s.
When pressed, all 3 LEDs will flash until the generator status is received.
Status Codes the LED’s are not lit continuously; instead they are briefly flashed as indicated below.
NOTICE During the weekly exercise cycle, the generator will run for 20 minutes, but it will not supply power to the home.
During the exercise cycle, the monitor will continue blinking the GENERATOR READY green LED.
• GENERATOR READY - When active, the green LED will
GENERATOR READY
Other:
LED Lighting Codes
• No status LEDs illuminated - Generator in OFF mode or check and replace batteries.
Wireless communication lost issues can typically be resolved by moving the wireless monitor closer, within the home, to the standby generator. See
Optional Router Accessory Kit
• Batteries Inserted - the shield LED will light for 5
• seconds.
- Each icon will light
• Linking Error or Not Linked - Each LED will light then turn off in one direction, then the other direction
until a successful link is completed.
• During the weekly exercise cycle , the generator
• During the weekly exercise cycle, the generator will run for 20 minutes, but it will not supply power to the home. During the exercise cycle, the monitor will
the home. During the exercise cycle, the monitor will
Service Code Descriptions flashes are listed on the back side of the wireless flashes are listed on the back side of the wireless monitor.
- name and number of
Service Code Descriptions - name and number of
• GENERATOR POWER - When active, the green LED will red SERVICE NEEDED the generator is supplying power.
• SERVICE NEEDED - When active, the red LED will flash
For example, when Low Frequency scrolls across the
Generator Status second pause between series of blinks until it is reset or the condition is corrected. Contact the nearest authorized service dealer if the problem can not be
Pressing the SYSTEM UPDATE
Not for current Generator Status by flashing the status icons.
NOTICE mode.
fixed.
Service conditions will only be displayed on the status is received.
XXXXX XXXXX
Reproduction
GENERATOR READY - When active, the shield icon will flash green once every 7 seconds. The green shield icon indicates that the generator is in AUTO mode and that it is ready to run in the event of a loss of utility power.
XXXXX
None of the service needed codes are cleared at the wireless monitor. All alerts must be cleared at the generator control panel.
Optional Router Accessory Kit
GENERATOR POWER - When active, the power icon will flash green every 7 seconds. The green power icon indicates that the generator is supplying power.
The monitor has a line of sight range of up to 200 feet, but this distance will decrease if the signal has to pass through walls or other objects.
SERVICE NEEDED When the wrench icon flashes red, refer to the service codes on the back of the monitor or to the troubleshooting guide in the generator manual. Call the nearest authorized service dealer if problem cannot be
fixed.
If upon installation and setup of the wireless monitor system communication is not reliable, Optional Router
Accessory Kit may be needed. See Authorized Dealer for more information.
The router is a small extender that can be used to expand the range of a generator wireless network so that network devices can seamlessly communicate with one another.
• No status icons illuminated - Generator in OFF
mode or check and replace batteries.
Wireless communication lost issues can typically be
resolved by moving the wireless monitor closer,
within the home, to the standby generator. See
Optional Router Accessory Kit
The router can be plugged into any standard 110VAC outlet within the home.
• Batteries Inserted - the shield icon will light for 5
seconds.
advertisement
Related manuals
advertisement
Table of contents
- 4 Safety Rules
- 4 Important Safety Instructions
- 7 Installation
- 7 For the Installing Dealer/Contractor
- 8 Owner Orientation
- 9 Generator Location
- 10 Delivery Inspection
- 11 Controls
- 12 Access Panels
- 14 System Control Panel
- 16 General Set Up Screen
- 18 Operation
- 18 Important Owner’s Considerations
- 19 Automatic Operation Sequence
- 19 Setting Exercise Timer
- 20 Wireless Monitor
- 23 Maintenance
- 23 Servicing the System
- 23 Service Code Detection System
- 25 Maintenance Schedule
- 25 Generator Maintenance
- 27 Engine Maintenance
- 29 Engine Oil
- 31 Fuel System Inspection and Maintenance
- 32 When Calling for Assistance
- 32 Storage
- 34 Troubleshooting
- 35 Wireless Monitor Troubleshooting
- 36 Generator Specifications
- 36 Engine Specifications
- 40 Reglamento de seguridad
- 40 Instrucciones de seguridad importantes
- 43 Instalación
- 43 Para el contratista o distribuidor de la instalación
- 44 Orientación para el propietario
- 45 Ubicación del generador
- 46 Inspección de entrega
- 47 Controles
- 48 Paneles de acceso
- 50 Panel de control del sistema
- 52 Pantalla General Set Up
- 54 Operación
- 54 Consideraciones importantes del propietario
- 55 Secuencia de funcionamiento automático
- 55 Ajuste del temporizador de ejercicio
- 56 Monitor inalámbrico opcional
- 59 Mantenimiento
- 59 Mantenimiento del sistema
- 59 Sistema de detección de códigos de mantenimiento
- 61 Programa de mantenimiento
- 61 Mantenimiento del generador
- 65 Aceite del motor
- 66 Mantenimiento del filtro de aire
- 67 Mantenimiento e inspección del sistema de combustible
- 68 Mantenimiento de las bujías
- 68 Cuando llame para pedir asistencia
- 68 Almacenamiento
- 70 Solución de problemas
- 71 Solución de problemas del monitor inalámbrico
- 72 Especificaciones
- 72 Especificaciones del generador
- 72 Especificaciones del motor
- 76 Règles de sécurité
- 76 Consignes de sécurité importantes
- 79 Installation
- 79 Au détaillant ou à l’entrepreneur procédant à l’installation
- 80 Conseils au propriétaire
- 81 Emplacement de la génératrice
- 82 Vérification de la livraison
- 83 Commandes
- 84 Panneaux d'accès
- 86 Tableau de commande du système
- 88 Écran de configuration générale
- 90 Utilisation
- 90 Considérations importantes pour le propriétaire
- 91 Séquence de fonctionnement automatique
- 91 Réglage de la minuterie du cycle d’exercice
- 92 Moniteur sans fil facultatif
- 95 Entretien
- 95 Entretien du système
- 95 Système de détection des codes de défaillance
- 97 Calendrier d'entretien
- 97 Entretien de la génératrice
- 99 Entretien du moteur
- 101 Huile à moteur
- 103 Inspection et entretien du circuit d'alimentation
- 104 Si vous téléphonez pour obtenir de l’aide
- 104 Entreposage
- 106 Dépannage
- 107 Dépannage du moniteur sans fil
- 108 Spécifications
- 108 Spécifications de la génératrice
- 108 Spécifications du moteur