advertisement
A PPENDIX 2 ________________________________________________________________________
APPENDIX 2
POWER SUPPLY MODULE
APPENDIX 2 ..................................................................................................................................................... 101
P OWER SUPPLY MODULE .................................................................................................................................. 102
Installing the power supply module ........................................................................................................... 102
T ECHNICAL SPECIFICATIONS ............................................................................................................................ 103
Setting and activating the outputs using an RS line ................................................................................... 134
V AISALA ________________________________________________________________________ 101
A PPENDIX 2_________________________________________________________________________
Power supply module
Installing the power supply module
The mains power connection may be connected to the power supply module only by an authorized electrician. A readily accessible disconnect device shall be incorporated in the fixed wiring (IEC 950).
Remove the plastic plug in the transmitter housing and replace it with the cable gland. Fasten the power supply module to the bottom of the housing with four screws; select the correct mains voltage with voltage selector switch (230/115).
Attach the grounding wire screw and washer to the grounding terminal on the right-hand side of the module. Attach the wires from the power supply module to the power terminal on the main board of the transmitter.
NOTE The jumper in connector X3 has to be in position ON; otherwise no power is supplied to the transmitter.
When the power supply module is on, the power on LED is lit.
RED
BLK from power supply module update the instrument label with the correct supply voltage label according to the selected operating voltage
4 pcs M3 screws for mounting
(prefix with fibre washers)
+ + -
BLK
X3
RED N
L voltage selector switch
115/230 VAC
M4 screw and washer for protective ground terminal
AC mains terminal replace plastic plug with cable gland for ¢ 7...12 mm cable probe cable gland signal cable gland arrange signal cable wires so that they do not reach bare AC wires when the cover is closed power supply cable: strip wires only 5 mm use crimped terminal for ground wire if stranded wire is used
102____________________________________________________________________M210492 EN A
A PPENDIX 2 ________________________________________________________________________
Peel the correct power supply voltage from the sticker enclosed in the power supply module package and attach it on the instrument label to indicate that the supply voltage has been changed.
WARNING Do not detach the power supply module from the transmitter when the power is on.
WARNING Do not connect the power supply to mains when it is not installed in a
DMP248 transmitter.
Technical specifications
Operating voltage
Connections
Bushing
Indicator
Operating temperature range
Storage temperature range
115 VAC (93...127 V)
230 VAC (187...253 V) screw terminals for 0.5...
2.5 mm 2 wire (AWG 20...14) for 7...12 mm diameter cable
PWR ON LED on power supply module board
-40...+45
°
C
-40...+70
°
C
V AISALA ________________________________________________________________________ 103
advertisement
Related manuals
advertisement
Table of contents
- 5 CHAPTER 1 GENERAL INFORMATION
- 7 CHAPTER 2 PRODUCT DESCRIPTION
- 10 Use in high pressure
- 11 CHAPTER 3 INSTALLATION
- 13 Mounting; overview
- 14 Mounting the probe directly to the process
- 15 Installing the probe through the ball valve assembly
- 21 Mounting the probe with a quick connect
- 22 Sample cell
- 24 Grounding
- 26 Connections
- 27 Connection to an AC supply
- 29 CHAPTER 4 COMMISSIONING
- 37 CHAPTER 5 COMMANDS
- 59 CHAPTER 6 CALIBRATION AND ADJUSTMENT
- 60 Two-point calibration and adjustment adjustment procedure
- 60 Using serial commands
- 61 Using display/keypad commands
- 62 Using LED commands
- 63 Humidity calibration table
- 63 One point offset correction
- 63 Using serial commands
- 64 Using display/keypad commands
- 64 Using LED commands
- 65 Two-point temperature calibration and adjustement
- 65 Using serial commands
- 66 Using display/keypad commands
- 66 Using LED commands
- 67 Using serial commands
- 67 Using display/keypad commands
- 68 Using LED commands
- 71 CHAPTER 7 MAINTENANCE
- 76 CHAPTER 8 TECHNICAL DATA
- 80 CHAPTER 9 OPTIONS
- 81 CHAPTER 10 SPARE PARTS AND ACCESSORIES
- 83 APPENDIX 1 SERIAL COMMANDS
- 105 APPENDIX 2 POWER SUPPLY MODULE
- 109 APPENDIX 3 INSTALLING AND USING THE RS 485/422 SERIAL PORT MODULE
- 119 APPENDIX 4 INSTALLING AND USING THE CURRENT LOOP MODULE
- 129 APPENDIX 5 ERROR MESSAGES
- 133 APPENDIX 6 WIRING DIAGRAM
- 135 APPENDIX 7 ALARM OUTPUT UNIT
- 141 APPENDIX 8 PRESSURE CONVERSION CHART
- 141 Multiplication factors