APPENDIX 2 POWER SUPPLY MODULE. Vaisala DMP248

Add to My manuals
141 Pages

advertisement

APPENDIX 2 POWER SUPPLY MODULE. Vaisala DMP248 | Manualzz

A PPENDIX 2 ________________________________________________________________________

APPENDIX 2

POWER SUPPLY MODULE

APPENDIX 2 ..................................................................................................................................................... 101

P OWER SUPPLY MODULE .................................................................................................................................. 102

Installing the power supply module ........................................................................................................... 102

T ECHNICAL SPECIFICATIONS ............................................................................................................................ 103

Setting and activating the outputs using an RS line ................................................................................... 134

V AISALA ________________________________________________________________________ 101

A PPENDIX 2_________________________________________________________________________

Power supply module

Installing the power supply module

The mains power connection may be connected to the power supply module only by an authorized electrician. A readily accessible disconnect device shall be incorporated in the fixed wiring (IEC 950).

Remove the plastic plug in the transmitter housing and replace it with the cable gland. Fasten the power supply module to the bottom of the housing with four screws; select the correct mains voltage with voltage selector switch (230/115).

Attach the grounding wire screw and washer to the grounding terminal on the right-hand side of the module. Attach the wires from the power supply module to the power terminal on the main board of the transmitter.

NOTE The jumper in connector X3 has to be in position ON; otherwise no power is supplied to the transmitter.

When the power supply module is on, the power on LED is lit.

RED

BLK from power supply module update the instrument label with the correct supply voltage label according to the selected operating voltage

4 pcs M3 screws for mounting

(prefix with fibre washers)

+ + -

BLK

X3

RED N

L voltage selector switch

115/230 VAC

M4 screw and washer for protective ground terminal

AC mains terminal replace plastic plug with cable gland for ¢ 7...12 mm cable probe cable gland signal cable gland arrange signal cable wires so that they do not reach bare AC wires when the cover is closed power supply cable: strip wires only 5 mm use crimped terminal for ground wire if stranded wire is used

102____________________________________________________________________M210492 EN A

A PPENDIX 2 ________________________________________________________________________

Peel the correct power supply voltage from the sticker enclosed in the power supply module package and attach it on the instrument label to indicate that the supply voltage has been changed.

WARNING Do not detach the power supply module from the transmitter when the power is on.

WARNING Do not connect the power supply to mains when it is not installed in a

DMP248 transmitter.

Technical specifications

Operating voltage

Connections

Bushing

Indicator

Operating temperature range

Storage temperature range

115 VAC (93...127 V)

230 VAC (187...253 V) screw terminals for 0.5...

2.5 mm 2 wire (AWG 20...14) for 7...12 mm diameter cable

PWR ON LED on power supply module board

-40...+45

°

C

-40...+70

°

C

V AISALA ________________________________________________________________________ 103