TH2515 Operation Manual command is sent, you will be unable to operate TH2515 from the front panel including the soft key LOCAL. Execute the LOCAL command to undo LOCAL LOCKOUT.
REMOTE
Set the control mode as remote control.
SPOLL
The SPOLL (serial poll) command is set the bus address status byte. 8 bytes are used to shield, read and judge the instrument operating status.
SERVICE REQUEST
When TH2515 requires the controller to execute a task, it will send out a SRQ service request control signal. SRQ, deemed as an interruption, will inform the controller to prepare the transmitted data or that errors exist on the instrument. As soon as TH2515 sends a SRQ service request signal, it will set the status byte to 6. 6 bytes are RQS request service bytes and sometimes connects with serial poll to act as the status byte.
When TH2515 enables the SPOLL command, it will clear the RQS request service bit and the SRQ string. Each bit in a status byte will enables a SRQ service request. User can shield the status byte to judge which bit causes TH2515 to set SRQ. For details, see
“Status Byte”.
TRIGGER (GET)
Trigger bus command. This command can be sent to a selected device or all listener devices. It is necessary to assign TH2515 as a listener device firstly and then set the trigger mode as bus trigger mode. Finally send trigger data.
6.2.4
SCPI (Standard Commands for Programmable
Instruments)
SCPI is a new general command based on the IEEE488.2-1987 standard. (SCPI is the same as TMSL, a system language for measurement testers adopted by HP.)
System for Component X System for Component Y
BUS
Relative information for measurement tester
Common commands and query
Syntax and data structure
Remote control
D C B A A B C D
IEEE488.1 Standard IEEE488.1 Standard IEEE488.1 Standard
SCPI SCPI
Where : Level D shows the instrument functions
46
advertisement
Related manuals
advertisement
Table of contents
- 7 Introduction to Instrument, Unpacking and Installing
- 7 Introduction to Instrument
- 7 Unpacking
- 7 Power Connection
- 8 Environment
- 8 Use of Test Fixture
- 8 Warm-up
- 8 Other Features
- 9 Introduction to Front and Rear Panels
- 9 Introduction to Front Panel
- 10 Introduction to Rear Panel
- 11 Display Zone
- 12 Introduction to Buttons on Front Panel
- 12 [MEAS DISP]
- 12 [SYSTEM SETUP]
- 12 Simple Operation
- 13 Starting Up
- 14 Basic Operation
-
14
- 14 Measurement Functions
- 15 Measurement Range
- 16 Measurement Speed
- 16 File Manage
- 16 Tools
-
17
- 18 File Manage
- 18 Tools
- 18 COMP (ON/OFF)
- 19 Compare Mode and SETTINGS of ABS & Percent Error
-
19
- 20 STATIS DISP
- 21 Edge Mode and Settings of Its Relevant Values
- 21 Status ON/OFF
- 21 Parameters of Statistic Analysis
- 22 TOOLS
-
22
-
25
- 25 Temperature Correction
- 26 Temperature Conversion
- 27 Types of Temperature Sensor
- 28 Parameter Setting
-
28
- 29 Tools
- 31 System Setup and File Manage
- 31 System Setup
- 31 TouchTone
- 31 Language
- 32 Password
- 32 Bus Mode
- 33 Baud Rate
- 33 Bus Addr
- 33 EOC Signal
- 34 Err.OUT signal
- 35 Power Supply Frequency
- 35 Setting Time and Date
-
36
- 36 Introduction to Save/Recall
- 36 Structure of File Folder/File in a U Disk
- 41 IP ADDR
- 41 SUBNET MASK
- 41 GATEWAY
- 41 DNS SERVER1, DNS SERVER
- 42 Performance Index
- 42 Measurement Function
- 42 Measurement Parameters and Notations
- 42 Measurement Groups
- 42 Equivalent Mode
- 42 Range
- 42 Trigger
- 43 Mode of Test Terminal
- 43 Time Expenditure of Measurement
- 43 Average
- 43 Display Digits
- 44 Test Signal
- 44 Current range
- 44 Output Voltage of Open Circuit
- 44 Maximum Display Range
- 44 Measurement Accuracy
- 45 Basic Accuracy for Resistance Measurement
- 46 Accuracy for Temperature Measurement (Pt500)
- 46 Accuracy for Temperature Measurement (Analog Input)
- 47 Temperature correction factor
- 48 Remote Control
- 48 RS232C Connection
- 49 GPIB Bus (option)
- 51 GPIB Interface Function
- 51 GPIB Addressing
- 51 GPIB Bus Commands
- 52 SCPI (Standard Commands for Programmable Instruments)
- 53 LAN Remote Control System
- 55 Access TH2515 through a Browser
- 55 Access TH2515 through the Software of a Upper Computer
- 56 USBTMC Remote Control System
- 56 System Configuration
- 56 Install the Driver
- 57 USBVCOM Virtual Serial Port
- 57 System Configuration
- 57 Installing Driver
- 59 SCIP Command Reference
- 59 TH2515 Subsystem Commands
- 59 DISPlay Subsystem Commands
- 61 FUNCtion Subsystem Commands
- 65 APERture Subsystem Commands
- 66 TRIGger Subsystem Commands
- 67 FETCH? Subsystem Commands
- 69 TEMPerature Subsystem Commands
- 71 COMParator Subsystem Commands
- 74 BIN Subsystem Commands
- 79 STATistics Subsystem Commands
- 83 IO Subsystem Commands
- 83 MEMory Subsystem Commands
- 84 SYSTem Subsystem Commands
- 87 GPIB Common Commands
- 91 Handler Interface
- 95 Package Contents and Warranty
- 95 Package Contents
- 95 Marks
- 95 Package
- 96 Shipping
- 96 Storage
- 96 Warranty