Figure 38: Mains input cable connection to AC distribution cabinet (automatically switch AC distribution cabinet)
2N
1N 1C 1B 1A
2C
2B 2A
Terminal of route one input cable
Terminal of route two input cable
1N 1C 1B 1A
2N 2C 2B 2A
Top view
Rear view
Connecting DC Emergency Lighting Cables (Optional)
Connection of AC distribution cabinet and DC distribution cabinet
The DC emergency lighting contactor is an optional part that locates at the bottom part of the AC distribution cabinet, as shown in Figure 39 . (removing the panel). In the event of AC mains failure, the AC monitoring circuit closes the DC emergency lighting contactor, and then 48V voltage is available at its output terminal.
Choose a 100A load fuse in the DC distribution cabinet to supply DC power for emergency lighting, and then connect this fuse to the DC contactor by means of cable (which should be sized for the emergency lighting power).
Follow the steps below to connect the emergency lighting cables.
1. Determine the cable length according to the actual wiring route.
2. Add cable lugs to both ends of the cables.
3. Connect one end of the positive cable (cable 2) to the positive busbar of the DC distribution cabinet, and one end of the negative cable (cable 1) to the load fuse in the DC distribution cabinet.
4. Connect the other end of the positive cable (cable 2) to the positive emergency lighting busbar, and the other end of the negative cable (cable 1) to the DC contactor, as shown in Figure 39 .
5. Connect one end of the positive emergency lighting cable to the positive emergency lighting busbar, and the other end to the positive terminal of the emergency lighting. Connect one end of the negative emergency lighting cable to the bottom terminal of the emergency lighting MCB, and the other end to the negative terminal of the emergency lighting, as shown in Figure 39 .
Vertiv | NetSure 801 CAA Series Power Supply System Instruction Manual 57
advertisement
Related manuals
advertisement
Table of contents
- 5 Safety Precautions
- 5 Electrical Safety
- 6 Battery
- 7 Others
- 8 OVERVIEW
- 8 Model Information
- 8 Overview
- 9 Components
- 9 Rectifier
- 11 Controller
- 11 AC Distribution Cabinet
- 16 DC Distribution Cabinet
- 24 Rectifier Cabinet
- 29 installation preparation
- 29 Installation Requirements
- 29 Environmental Requirements
- 29 Layout Requirements of The Equipment Room
- 32 Power Supply
- 33 Safety Protection
- 34 Equipment Running Environment Checklist
- 36 Storage Conditions
- 36 Installation Preparation
- 40 Unpacking Inspection
- 42 Installation
- 42 Cabinet Installation
- 42 Cabinet Placement
- 43 Mounting Large Side Door And Small Side Door
- 43 Installation on The Floor
- 45 Installation on Supporting Rack
- 46 Parallel Connection Between Cabinets
- 46 Parallel Connection with Copper Bars
- 49 Connecting Power Cables
- 50 Connecting Earth Cable
- 52 Distribution Cabinet
- 55 Connecting AC Input Cables
- 57 Connecting DC Emergency Lighting Cables (Optional)
- 58 Connecting DC Load Cables
- 59 Connecting Battery Cables
- 60 Installation Checklist
- 61 Installing Rectifier and Controller
- 61 Installing Rectifier
- 62 Installing Controller
- 63 Board
- 66 Cable
- 66 Connecting Rectifier Cabinet Communication Cable
- 68 Cabinet
- 69 Connecting Communication Cable of Distribution Cabinet
- 71 Installing Options
- 71 Installing Temperature Sensor
- 73 Testing
- 73 Note on Testing
- 73 Power-on
- 75 Setting Basic Parameters
- 75 Setting DIP Switch
- 76 Setting Basic Parameters for Controller
- 82 Checking Alarm and Operation Status
- 82 Testing Controller
- 84 Testing AC Distribution
- 85 Testing DC Distribution
- 86 Access Controller Through Web
- 94 Operation
- 94 Power Distribution LCD Operation
- 96 Controller Operation of Rectifier Cabinet
- 96 System Alarm and Status
- 96 Distribution Parameters Setting
- 96 Setting the Position Number of The Rectifier Manually
- 100 Adding Load
- 100 Adding Rectifier
- 101 Maintenance
- 101 Maintenance Requirements
- 101 General
- 101 Maintenance Tools and Equipment
- 102 Reference Technical Specification for Maintenance
- 104 Routine Maintenance Items
- 107 Routine Maintenance
- 108 Basic Inspection
- 108 Handling Controller Fault
- 108 Handling Rectifier Fault
- 110 Replacing Rectifier
- 111 Emergency Treatment
- 113 Appendix 1 Technical Parameters
- 116 Appendix 2 Alarm list
- 122 Appendix 3 ENGINEERING DESIGN DIAGRAM
- 138 APPENDIX 4 WIRING DIAGRAM
- 156 Appendix 5 SPARE PARTS