BasicController CR0403

Activate the PLC configuration

35713

The PLC configuration is automatically loaded with the target system. The PLC configuration maps the contents of the file CR0403.cfg in CODESYS. Like this, the programmer has easy access to predefined system and error flags, inputs and outputs as well as to the CAN interfaces of the device.

To access the PLC configuration (e.g. CR1080):

► Click on the tab [Resources] in CoDeSys:

► Double-click on [PLC Configuration] in the left column.

>

Display of the current PLC configuration (

following figure):

> Based on the configuration the following is available in the program environment for the user:

System and error flags

Depending on the application and the application program, these flags must be processed and evaluated. Access is made via their symbolic names.

Structure of the inputs and outputs

These can be directly symbolically designated (highly recommended!) in the window [PLC

Configuration] (example → figure below) and are available in the whole project as [Global

Variables].