MEM_ERROR. IFM CR0403

Add to My manuals
231 Pages

advertisement

MEM_ERROR. IFM CR0403 | Manualzz

BasicController CR0403

MEM_ERROR

= Memory Error

Unit type = function block (FB)

Unit is contained in the library ifm_CR0403_Vxxyyzz.LIB

Symbol in CODESYS:

35126

>

Description

>

MEM_ERROR signals errors in some parameters or in the memory.

The memory areas can be deleted via the corresponding FB inputs.

Parameters of the inputs

Parameter

ENABLE

RESET_RETAIN

Data type

BOOL

BOOL

RESET_OHC

>

Parameters of the outputs

BOOL

Description

TRUE: execute this function element

FALSE: unit is not executed

> Function block inputs are not active

> Function block outputs are not specified

TRUE: Delete non-volatile retain memory

FALSE: No changes to memory contents

TRUE: Delete non-volatile OHC memory

FALSE: No changes to memory contents

Parameter

COM_ERR

CALIB_ERR

RETAIN_ERR

OHC_ERR

RESULT

Data type

BOOL

BOOL

BOOL

BOOL

BYTE

Description

Download ID and baud rate are set to default values

(download parameters got lost)

Calibration values are invalid

(analogue inputs, PWM outputs, system voltages)

Retain memory is invalid

(e.g. partially deleted due to strong magnetic field)

OHC values are invalid

(e.g. partially deleted due to strong magnetic field) feedback of the function block

(possible messages → following table)

Possible results for RESULT:

Value dec | hex

Description

0

1

00

01

FB is inactive

FB execution completed without error – data is valid

35341

35006

35100

191