Installation
3. Use the three screws from the envelope located in the cylinder to attach the power cord wires to the terminal block.
Four-Wire Plug
1
2
1
4
2
3
3
D286I
1
2
3
“L1” Terminal
Neutral Terminal
“L2” Terminal
Figure 29
4. Tighten all screws and reinstall access cover removed in step 1.
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
5. Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.
6. Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of cabinet.
7. Reinstall access cover and screw.
3
4
1
2
Typical Four-Wire Receptacle
Power Cord – Not supplied with dryer
(Four-Wire)
Strain Relief Nut
Strain Relief
D815I
Figure 30
1. Remove access cover from rear of dryer.
D695I
Figure 31
800937 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23
Installation
2. Remove the three screws holding the three wires to the terminal block terminals. Save these
screws. Loosen the strain relief screw and pull the cord or wires out through the rear of the dryer.
5. Attach power cord ground (green) wire to rear bulkhead using ground screw removed in step 3.
6. Use the three screws from the envelope located in the cylinder to attach the remaining power cord wires to the terminal block as follows: a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.
1
2
24
D696I
Figure 32
3. Remove ground screw and save for use in step 5.
Remove wire and use in step 6.
D697I
D697I
1
Ground Screw
Figure 33
4. Use a strain relief and insert end of power cord through power supply hole.
1
1
D698I
Power Cord Ground Wire
Figure 34
1
D698I
7
6
5
3
4
DRY522N
5
6
7
3
4
1
2
“L1” Terminal
White
“L2” Terminal
Black
Green
Red
Neutral Terminal
Figure 35
NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
8. Check the continuity of the ground connection before plugging the cord into the outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of cabinet.
9. Reinstall access cover and screw.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
800937
advertisement
Related manuals
advertisement
Table of contents
- 12 Step 3: Connect Drain Hose to Drain Receptacle
- 14 Step 4: (Gas Dryer Only) Connect Gas Supply Pipe
- 15 Step 5: (Electric Dryer Only) Connect Electrical Plug
- 16 Step 6: Connect Dryer Exhaust System
- 17 Step 7: Position and Level the Unit
- 18 (Washer Only)
- 18 Step 9: Wipe Out Inside of Washer Drum and Dryer Drum
- 19 Step 10: Plug In the Washer and Dryer
- 19 Step 11: Check Installation
- 19 Moving Unit to a New Location
- 20 Heat Source Check
- 20 Electric Dryers
- 20 Gas Dryers
- 21 Electrical Requirements
- 21 Washer
- 22 Electric Dryer
- 24 Electrical Plug Connection
- 24 Three-Wire Plug
- 25 Four-Wire Plug
- 27 Electrical Requirements
- 27 Gas Dryer
- 29 Gas Requirements
- 31 Water Supply Requirements
- 31 Water Temperature
- 31 Water Pressure
- 31 Risers
- 32 Location Requirements
- 33 Dryer Exhaust Requirements
- 33 Exhaust System Materials
- 34 Make-Up Air Requirements
- 34 Make-Up Air Dos and Don’ts
- 34 Exhaust Direction
- 35 Exhaust System
- 36 Exhaust System Maintenance
- 36 Dryer Airflow
- 37 Information for Handy Reference
- 45 Piezas de repuesto
- 47 Instalación
- 47 Dimensiones y especificiones
- 48 Antes de comenzar
- 48 Herramientas
- 48 Ubicación
- 48 Ducto de escape
- 48 Requisitos eléctricos
- 49 Instalación de la unidad
- 49 Paso 1: Coloque la unidad cerca del área de instalación
- 49 Paso 2: Conecte las mangueras de suministro de agua
- 50 de desagüe
- 52 suministro de gas
- 53 suministro de energía eléctrica
- 54 Paso 6: Conecte el sistema de escape de la secadora
- 55 Paso 7: Coloque la unidad en su lugar y nivélela
- 56 (en la lavadora solamente)
- 56 la secadora
- 57 Paso 10: Enchufe la lavadora y la secadora
- 57 Paso 11: Revise la instalación
- 57 Desplazamiento de la unidad a un nuevo sitio
- 58 Revisión de la fuente de calor
- 58 Secadoras eléctricas
- 58 Secadoras a gas
- 59 Requisitos eléctricos
- 59 Lavadora
- 60 Secadoras eléctricas
- 62 Conexión eléctrica
- 62 Enchufe de tres conductores
- 63 Enchufe de cuatro conductores
- 65 Requisitos eléctricos
- 65 Secadoras a gas
- 67 Requisitos de la fuente de suministro de gas
- 69 Requisitos de suministro de agua
- 69 Temperatura del agua
- 69 Presión del agua
- 69 Tubos ascendentes
- 70 Requisitos del lugar
- 71 Requisitos del sistema de escape de la secadora
- 71 Materiales del sistema de escape
- 72 Requisitos de aire de reposición
- 72 Qué hacer y qué no hacer
- 72 Dirección del escape
- 73 Sistema de escape
- 74 Mantenimiento del sistema de escape
- 74 Flujo de aire de la secadora
- 75 Información de referencia